Keysight

/

Keysight DP5792AH

SCPI COMMAND REFERENCE

Keysight DP5792AH

Keysight DP5792AH

The Keysight DP5792AH is Keysight's power supply in the DP5700 Series System DC Power Supplies family. Its SCPI remote-control interface exposes 219 commands across 29 subsystems - 133 settable and 86 queries - and every command is documented here with its parameters, accepted values, return format, and a copy-paste PyVISA example for automating test and measurement.

219

Commands

133

Settable

86

Queries

29

Subsystems

SCPI

Verified

2026-07-16

All commands

:CONF:RANGEset / query

Selects the analog monitoring and programming range. The available ranges are 5 V or 10 V.

NameTypeValuesDescription
rangeenum5 | 10Selects the analog monitoring and programming range.
:CONF:POWERset / query

Enters a constant power value. The available range is model dependent, from Min to Max.

NameTypeValuesDescription
valuerealMin - MaxConstant power setting to store.
:CONF:RESset / query

Enters a resistance value from 0.001 to 1.000 ohms. This selection only appears when the internal resistance function is on.

NameTypeValuesDescription
valuereal0.001 - 1.000Resistance value to set.
:CONF:SLEWset / query

Selects the current or voltage slew rate. OFF turns the slew function off; CURR selects the current slew control and VOLT selects the voltage slew control.

NameTypeValuesDescription
modeenumOFF | CURR | VOLTSelects the slew control mode.

:SYST:DISPset / query

Configures the front-panel brightness and dimming behavior. The available mode selects brightness, dimming value, or dimming delay.

NameTypeValuesDescription
modeenumBRT | DM.BRT | DM.DLSelects the front panel display configuration to adjust.
:SYST:ENAset / query

Turns the power supply output enable on or off.

NameTypeValuesDescription
stateenumOFF | ONSets the output enable state.
:SYST:ILCset / query

Turns the Interlock function on or off.

NameTypeValuesDescription
stateenumOFF | ONTurns the Interlock function on or off.
:SYST:PRELset / query

Turns the preload state on or off.

NameTypeValuesDescription
stateenumOFF | ONTurns the preload state on or off.
:SYST:RECALset / query

Recalls a saved output state from memory location 0 through 9.

NameTypeValuesDescription
stateinteger0 - 9Location number of the saved output state to recall.
:SYST:SAVEset / query

Saves the present output state to a location numbered 0 through 9.

NameTypeValuesDescription
stateinteger0 - 9Location number where the present output state is saved.
:SYST:SENSEset / query

Selects local or remote voltage sensing.

NameTypeValuesDescription
sense modeenumLOCAL | REMSelects whether voltage sensing is local or remote.

:COMM:IP4set / query

Configures the IP4 address from 1 to 4. The address value is entered as four parts, each part ranging from 0 to 255.

NameTypeValuesDescription
addressinteger1 - 4Selects which IP4 address field to configure.
:COMM:GPIBset / query

Configures the GPIB address.

NameTypeValuesDescription
addressinteger0 - 30GPIB address to set.
:COMM:LANset / query

Resets the LAN. A confirmation step is available with the SURE node, which confirms the reset with NO or YES.

NameTypeValuesDescription
SUREenumNO | YESConfirms the LAN reset.
:COMM:MACset / query

Configures or displays the MAC address entries. The manual shows MAC as an addressable group from 1 to 6, and individual entries MAC1 through MAC6 each display a value from 00 to FF.

NameTypeValuesDescription
addressinteger1 - 6Selects which MAC entry to access.

:PROT:OCLset / query

Turns the analog programming over-current protection function on or off.

NameTypeValuesDescription
stateenumOFF | ONTurns the analog programming over-current protection function on or off.
:PROT:OCPset / query

Turns the over-current protection function on or off.

NameTypeValuesDescription
stateenumOFF | ONSelects whether over-current protection is enabled.
:PROT:OVPset / query

Sets the overvoltage protection value. The value range is model dependent, from Min to Max.

NameTypeValuesDescription
valuerealMin - MaxOvervoltage protection level.
:PROT:PROTset / query

Clears all protection functions. A confirmation prompt is shown with the SURE selection, which accepts NO or YES.

:PROT:SUREset / query

Confirms clearing the protection functions. The confirmation response is YES or NO.

:VOLTage:SENSeset / query

Selects local or remote voltage sensing. Remote sensing is used to regulate the output voltage at the load rather than at the output terminals.

NameTypeValuesDescription
modeenumLOCal | REMoteChooses local or remote voltage sensing.

Enables or disables the internal resistance function, which simulates battery voltage drop as a response to load current.

NameTypeValuesDescription
stateboolean-Turns the internal resistance function on or off.

Sets the internal resistance value used to simulate battery voltage drop under load. The output voltage is adjusted as VOUT = V - I × RS.

NameTypeValuesDescription
leveloptreal0.001 - 1Internal resistance setting value.

Sets the voltage reference down programming slew. Slew-rate control is active only in Voltage/Current programming mode.

NameTypeValuesDescription
NRf+real0.0001 - 999.99Voltage reference down programming slew rate.

Sets the voltage reference up programming slew rate. The slew rate setting range is 0.0001 to 999.99 volts per millisecond in steps of 0.0001.

NameTypeValuesDescription
valuereal0.0001 - 999.99Voltage reference up programming slew rate.
[SOURce]:VOLTage:SLEW:UP <NRf+>

Turns on or off analog programming of voltage and selects the type of analog programming. OFF leaves voltage control to SCPI or the front panel, VOLTage uses an analog voltage signal, and RESistance uses an analog resistance signal.

NameTypeValuesDescription
modeenumOFF | VOLTage | RESistanceSelects the analog programming source for voltage.
[SOURce:]VOLTage:ANALog:SOURce OFF|VOLTage|RESistance
[SOURce:]VOLTage:ANALog:SOURce?

Turns on or off analog programming of voltage and selects the type of analog programming. OFF means voltage is controlled by SCPI or the front panel setting, VOLTage means an analog voltage signal, and RESistance means an analog resistance.

enum - Returns the current analog programming source selection.

Sets the transient mode, which determines what happens to the output voltage when the transient system is initiated and triggered. FIXed keeps the output voltage at its immediate value, and STEP steps the output to the triggered level when a trigger occurs.

NameTypeValuesDescription
modeenumFIXed | LIST | STEPTransient mode selection.
SOURVOLT:MODE FIXed

Sets the transient mode, which determines what happens to the output voltage when the transient system is initiated and triggered. FIXed keeps the output voltage at its immediate value, and STEP steps the output to the triggered level when a trigger occurs.

enum - Returns the present transient mode.

Sets the triggered voltage amplitude level. Units are in volts, and the maximum value depends on the voltage rating of the unit.

NameTypeValuesDescription
valuereal0 - 105% of ratingTriggered voltage amplitude level.
qualifieroptenumMIN | MAXReturns the minimum or maximum allowed value instead of a numeric level.
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <value>|MIN|MAX
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX]

Sets or queries the triggered voltage amplitude (triggered voltage level). The maximum value depends on the unit's voltage rating, and the query can also request the minimum or maximum value.

NameTypeValuesDescription
valuereal0 - 105% of ratingTriggered voltage amplitude to set.
qualifieroptenumMIN | MAXReturns the minimum or maximum allowed triggered voltage amplitude.
real (V) - Returns the triggered voltage amplitude in volts, or the minimum/maximum value when queried with a qualifier.
Sets the output voltage level to 20 V: VOLT 20

Sets the immediate voltage level. The value is in volts and may also be queried for its present setting or for the minimum or maximum allowed value.

NameTypeValuesDescription
voltreal0 - 105% of ratingImmediate output voltage level to set.
qualifieroptenumMIN | MAXRequests the minimum or maximum allowed voltage level when used with the query form.
real (V) - Returns the present voltage level, or the minimum/maximum allowed level when queried with MIN or MAX.
Sets the output voltage level to 20 V: VOLT 20

Sets the immediate output voltage level. Units are volts, and the maximum value depends on the unit's voltage rating.

NameTypeValuesDescription
voltreal0 - 105% of ratingImmediate output voltage level.
qualifieroptenumMIN | MAXReturns the minimum or maximum allowed voltage level instead of the programmed value.
real (V) - Returns the present immediate voltage level, or the minimum/maximum value when queried with MIN or MAX.
Sets the output voltage level to 20 V: VOLT 20

Sets the under-voltage protection delay time. Units are in seconds.

NameTypeValuesDescription
timereal0.1 - 25.5Delay time before under-voltage protection trips.
qualifieroptenumMIN | MAXSelects the minimum or maximum allowed delay time.

Sets the under-voltage protection delay time. Units are in seconds.

NameTypeValuesDescription
timereal0.1 - 25.5Delay time before under-voltage protection disables the output.
qualifieroptenumMINimum | MAXimumReturns the minimum or maximum delay time instead of a numeric value.
[SOURce:]VOLTage:PROTection:LOW:DELay <time>|MIN|MAX
[SOURce:]VOLTage:PROTection:LOW:DELay? [MIN|MAX]

Enables or disables under-voltage protection.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables under-voltage protection.
integer - Returns 0 or 1 indicating the under-voltage protection state.

Sets the under-voltage protection level. If under-voltage protection is enabled and the output voltage falls below this level for longer than the programmed delay, the output is disabled and the Questionable Condition status register UV bit is set.

NameTypeValuesDescription
voltreal0 - 95% of voltage settingUnder-voltage protection level.
qualifieroptenumMINimum | MAXimumSets the level to the minimum or maximum allowed value.

Sets the under-voltage protection level. If under-voltage protection is enabled and the output voltage goes below this level for longer than the programmed delay time, the output is disabled and the Questionable Condition status register UV bit is set.

NameTypeValuesDescription
levelreal0 - 95% of voltage settingUnder-voltage protection threshold.
qualifieroptenumMIN | MAXSets the protection level to the minimum or maximum allowed value.
real (V) - Returns the under-voltage protection level.

Sets the over-voltage protection level. If the output voltage exceeds the OVP level, the output is disabled and the Questionable Condition status register OV bit is set.

NameTypeValuesDescription
voltreal105% of voltage setting - 110% of voltage ratingOver-voltage protection level.
qualifieroptenumMIN | MAXSelects the minimum or maximum allowed over-voltage protection level.
[SOURce:]VOLTage:PROTection[:LEVel] <volt>|MIN|MAX
[SOURce:]VOLTage:PROTection[:LEVel]? [MIN|MAX]

Queries the present over-voltage protection level. Units are volts; the query may be qualified with MIN or MAX to return the corresponding limit value.

NameTypeValuesDescription
qualifieroptenumMIN | MAXSelects the minimum or maximum over-voltage protection level to query.
real (V) - Returns the over-voltage level in volts, or the minimum/maximum allowed level when qualified with MIN or MAX.
SOURCe:VOLTage:PROTection:LEVel? MIN
SOURCe:VOLTage:PROTection:LEVel? MAX

Enables or disables output resistance. Only applies in constant voltage mode.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONSets whether output resistance is enabled or disabled.
enum - Returns the current output resistance state as 0 or 1.

Sets the output resistance level. Only applies in constant voltage mode. Units are in ohms.

NameTypeValuesDescription
valuereal0.001 - 1.0Output resistance level to set.
qualifieroptenumMIN | MAXUse MIN or MAX to set the minimum or maximum resistance level.
real (ohm) - Returns the present output resistance level.

Selects local or remote voltage sensing. For compatibility, INTernal and EXTernal are also accepted in place of LOCal and REMote, and the setting is stored in non-volatile memory.

NameTypeValuesDescription
modeenumLOCal | INTernal | REMote | EXTernalSelects whether output voltage is sensed at the output terminals or the sense terminals.
enum - Returns the current voltage sensing mode.

Selects local or remote voltage sensing. For compatibility, INTernal and EXTernal are also accepted in place of LOCal and REMote.

NameTypeValuesDescription
sense modeenumLOCal | INTernal | REMote | EXTernalSelects the voltage sensing location.
enum - Returns the current voltage sensing setting.

Sets the negative voltage slew rate. The slew rate is specified in volts per second and can be set from 0.1 to 9.9999e+5, or to the maximum value with MAX.

NameTypeValuesDescription
slewreal0.1 - 9.9999e+5Voltage slew rate to set.
VOLT:SLEW 5

Sets the positive voltage slew rate. The slew rate is specified in volts per second and can be set from 0.1 to 9.9999e+5, with MAX selecting the maximum rate.

NameTypeValuesDescription
slewreal0.1 - 9.9999e+5Positive voltage slew rate to set.
qualifieroptenumMIN | MAXAlternative keyword for the slew rate value.
VOLT:SLEW 5

Acknowledges the parallel system configuration on the primary unit after initial assembly or any later change in system configuration. The front panel displays "WAIT ACK" until the configuration is acknowledged.

INSTrument:GROup:ACKNowledge

Returns the total number of units in the configuration.

integer - The total number of units in the configuration.

Queries the function of an instrument in a primary/secondary configuration.

enum - Returns the instrument function in the primary/secondary group.

:OUTPset / query

Turns the output on or off.

NameTypeValuesDescription
stateenumON | OFFSelects whether the output is enabled or disabled.
OUTP ON|OFF
:OUTP:ONset / query

Turns on the load output.

OUTP:ON

:POWset / query

Sets the output power limit for constant power mode. The limit can be programmed whether the output is ON or OFF, and the instrument enforces its rated maximum power.

NameTypeValuesDescription
powerrealWPower limit value to program.
POW 1000
:POW:STATset / query

Turns the programmed power limit setting on or off. The output power limit is maintained as long as output voltage and current remain within their programmed limits.

NameTypeValuesDescription
stateenumON | OFFTurns the programmed power limit setting on or off.
POW:STAT ON|OFF
POW 1000

:VOLT:PROTset / query

Sets the over-voltage protection (OVP) level. The manual shows an example setting the OVP level to 55 volts.

NameTypeValuesDescription
voltagerealVOVP level to set.
VOLT:PROT 55
:VOLT:PROT:LOWset / query

Sets the under-voltage protection level. The UVP setting prevents adjustment of the output voltage below the specified limit.

NameTypeValuesDescription
voltagereal0Under-voltage protection level.
VOLT:PROT:LOW 5

Sets the under-voltage protection delay time.

NameTypeValuesDescription
delay timereal0.0The UVP delay time to set.
VOLT:PROT:LOW:DEL 0.1

Enables or disables the under-voltage protection (UVP) status for the low-voltage protection function. When enabled, the UVP circuitry can prevent the output voltage from being set below the specified limit.

NameTypeValuesDescription
stateenumON | OFFTurns UVP protection on or off.
VOLT:PROT:LOW:STAT ON
:VOLT:LIMset / query

Sets the output voltage limit. In the transient recovery test example, it is programmed with the MAXimum qualifier.

NameTypeValuesDescription
limitrealVOutput voltage limit value.
qualifieroptenumMAXimumOptional limit qualifier.

:CURR:PROT:DELset / query

Sets the OCP delay time. The delay lets the over-current protection ignore momentary output settings, load, and status changes during the specified period.

NameTypeValuesDescription
delayreal0OCP delay time.
CURR:PROT:DEL 0.01
:CURR:PROT:STATset / query

Enables or disables over-current protection (OCP). When enabled, the power supply turns off the output if the output current reaches the current limit setting and transitions from CV to CC mode.

NameTypeValuesDescription
stateenumON | OFFTurns OCP on or off.
CURR:PROT:STAT ON

Enables analog over-current limit protection for the programmed current. When ON, the maximum current programming value is clamped to the current setting previously programmed from the front panel or the corresponding SCPI command.

NameTypeValuesDescription
stateenumON | OFFTurns analog over-current limit protection on or off.
CURR:ANALOG:LIM:STAT ON
:CURR:MODEset / query

Sets the current mode used by the load's list generator. In the example, LIST selects current priority for the transient test.

NameTypeValuesDescription
modeenumLISTSelects the current mode.
CURR:MODE LIST

Controls initiation of output transients. A transient must be initiated before it can be triggered.

Continuously initiates the transient trigger system, allowing multiple triggers to generate multiple output transients. With continuous triggering disabled, the trigger system must be initiated for each trigger.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables continuous triggering.
INIT:CONT ON

Continuously initiates the transient trigger system, allowing multiple triggers to generate multiple output transients.

integer - Returns the current continuous-trigger state as 0 or 1.
INIT:CONT ON

Initiates the trigger system, moving it from the idle state to the wait-for-trigger state so it can receive triggers. The instrument may need a few milliseconds before it is ready to accept a trigger after this command.

INIT:TRAN

Selects the trigger source for transient operation. Three methods are available: BUS, EXT, and IMM.

NameTypeValuesDescription
sourceenumBUS | EXT | IMMTrigger source selection.

Enables or disables the Constant Power Limit function. This command turns the power limit function on or off from the front panel menu or over remote communication.

NameTypeValuesDescription
stateenumBoolBoolean enable/disable state for the Constant Power Limit function.

Sets the constant power limit for the power supply. The setting range is limited by the multiplication of rated voltage by rated current, in steps of 1 watt.

NameTypeValuesDescription
valuerealrated voltage by rated currentConstant power limit value.

Enables or disables constant power operation.

integer - Returns the present constant power operation state.

Sets the power level when constant power operation is enabled. Units are in watts, and the maximum value depends on the power rating of the unit.

NameTypeValuesDescription
valuereal1 W - 100% of ratingPower level to set.
qualifieroptenumMIN | MAXOptional query qualifier to return the minimum or maximum power level.
real (W) - Returns the present power level.
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude] <value>|MIN|MAX
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX]

Sets the power level when constant power operation is enabled. Units are in watts, and the maximum value depends on the power rating of the unit.

NameTypeValuesDescription
valuereal1 W - 100% of ratingPower level to set.
qualifieroptenumMIN | MAXSelects the minimum or maximum allowed power level.
real (W) - Returns the present power level.

Enables or disables slew-rate control and selects whether it applies to voltage or current reference slew control. The function can be set to VOLT, CURR, or OFF.

NameTypeValuesDescription
stateenumVOLT | CURR | OFFSelects the slew-rate control mode or disables the function.

Locks or unlocks the front panel controls. See also SYSTem:KLOCk.

NameTypeValuesDescription
stateenumON | OFFSets the front panel lock-out state.
:SYSTem:KLOCkset / query

Locks or unlocks the front panel controls. The manual refers to this command together with SYSTem:COMMunicate:RLSTate for front-panel lock-out control.

Returns the initial socket control connection port number used to send and receive commands and queries. The port number varies and must be obtained with this query; it returns 0 if sockets are not supported.

integer - Initial socket control connection port number for the control socket connection, or 0 if sockets are not supported.
SYST:COMM:LAN:CONT?
SYST:COMM:TCP:CONT?

Enables or disables DHCP for the LAN interface. When enabled, the device obtains LAN parameters automatically from a DHCP server if one exists on the network.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables DHCP.
enum - Returns the current DHCP setting as 0 or 1.

Enables or disables DHCP for the LAN interface. When enabled, LAN parameters are obtained automatically from a DHCP server if one is available on the network.

enum - Returns the current DHCP state.

Returns the initial socket control connection port number used to send and receive commands and queries. The control socket port varies and must be obtained with this query; it returns 0 if sockets are not supported.

integer - The initial control connection port number.

Assigns a Domain Name System (DNS) server to be used when DHCP is disabled. Quotes around the address are required.

NameTypeValuesDescription
addressstring-DNS server address to assign.

Returns or queries the DNS server address used when DHCP is disabled. The optional qualifier selects either the current in-use value or the statically assigned value; if omitted, the default is CURRent.

NameTypeValuesDescription
qualifieroptenumCURRent | STATicSelects whether the query returns the value presently in use or the value assigned via the command.
string - The DNS server address as a quoted dotted-quad string. CURRent returns the data presently in use, while STATic returns the data assigned via the command; omitted qualifier defaults to CURRent.

Assigns a domain name to be used when DHCP is disabled. The quoted name is required, and a power cycle may be required for the setting to take effect.

NameTypeValuesDescription
namestring-Domain name to assign.

Assigns a domain name to be used when DHCP is disabled. The quoted name is required, and the setting is stored in non-volatile memory; a power cycle may be required for it to take effect.

string - Returns the domain name presently in use or the statically assigned domain name, depending on the optional qualifier.

Assigns a default gateway to be used when DHCP is disabled. The quotes around the address are required. The setting may require a power cycle to take effect and is stored in non-volatile memory.

NameTypeValuesDescription
addressstring-Default gateway address to assign.

Queries the instrument's default gateway address. The optional qualifier selects the currently used value or the value assigned by the command; if omitted, the default is CURRent.

NameTypeValuesDescription
qualifieroptenumCURRent | STATicSelects whether the query returns the address presently in use or the address assigned by the command.
string - Returns the gateway address as a quoted IPv4 address. CURRent returns the data presently in use, while STATic returns the data assigned via the command.

Assigns a hostname to the instrument. A hostname is the host portion of the full domain name, which is translated into an IP address. The quotes around the name are required, and the name may be up to 15 characters.

NameTypeValuesDescription
namestring-Hostname to assign to the instrument.

Assigns a hostname to the instrument. The hostname is the host portion of the full domain name and is quoted; the name may be up to 15 characters.

string - Returns the hostname presently in use or the hostname assigned via the command, depending on the optional qualifier.

Returns the instrument's Media Access Control (MAC) address. The address is unique to the instrument, set at the factory, and cannot be changed.

string - The instrument's MAC address.

Sets a static IP address to be used when DHCP is disabled. The quoted address is required, and a power cycle may be required for the setting to take effect.

NameTypeValuesDescription
addressstring-Static IP address to store for use when DHCP is disabled.
string - Returns the current or static IP address, depending on the optional qualifier; the default is CURRent if omitted.

Queries the current or static LAN IP address. If the optional qualifier is omitted, the default is CURRent.

NameTypeValuesDescription
qualifieroptenumCURRent | STATicSelects whether the current or static IP address is returned.
string - Returns the IP address in quoted dotted-decimal form, such as "192.168.0.100".

Sets a static subnet mask to be used when DHCP is disabled. The mask must be enclosed in quotes, and the setting is stored in non-volatile memory; a power cycle may be required for it to take effect.

NameTypeValuesDescription
maskstring-Static subnet mask to use when DHCP is disabled.

Sets a static subnet mask to be used when DHCP is disabled. The mask must be quoted, and if the optional query parameter is omitted the default is CURRent.

NameTypeValuesDescription
qualifieroptenumCURRent | STATicSelects whether the query returns the current or static subnet mask.
string - Returns the subnet mask as a quoted dotted-decimal address.

Queries the instrument's remote/local state. The returned value indicates whether the instrument is in local, remote, or remote-with-lock state.

enum - Returns the current remote/local state as LOC, REM, or RWL.
SYST :COMMunicate:RLSTate?
:SYSTem:DATEset / query

Sets the date of the real-time clock. Specify the year, month, and day.

NameTypeValuesDescription
yearinteger2000 - 2099Year of the date to set.
monthinteger1 - 12Month of the date to set.
dayinteger1 - 31Day of the date to set.
SYSTem:DATE <year>, <month>, <day>
SYSTem:DATE?

Sets or queries the real-time clock date. The setter specifies year, month, and day; the query returns the current date.

string - Returns the date of the real-time clock as year, month, and day.

Reads and clears one error from the error queue. Errors are returned first-in-first-out; if no error is present, the instrument responds with +0,"No error".

string - Returns an error code and error string in the format <error code>,<error string>. If no error is present, returns +0,"No error".
SYST:ERR?

Disables or enables the front-panel keyboard lock. When set to 1 or ON, the instrument can only be controlled remotely; the setting is nonvolatile.

enum - Returns the current keyboard lock state as 0 or 1.

Returns a description of an option. The option does not need to be installed for this command to work.

NameTypeValuesDescription
option namestring-Option name enclosed in quotes
string - A description of the specified option.

Installs a licensed option using a license string supplied by Keysight.

NameTypeValuesDescription
license_stringstring-License string, enclosed in quotes.

Indicates whether a named option is installed.

NameTypeValuesDescription
option namestring-Option name, enclosed in quotes.
enum - Returns 0 if the option is not installed and 1 if it is installed.
SYSTem:LICense:INSTall? "<option name>"

Clears all user memory to prepare the instrument for removal from a secure area. It sanitizes user data stored in EEPROM and/or flash memory, but does not erase identification data such as firmware, model number, serial number, MAC address, or calibration data.

:SYSTem:TIMEset / query

Sets the time of the real-time clock. Specify the hour, minute, and second.

NameTypeValuesDescription
hourinteger0 - 23Hour of the time to set.
minuteinteger0 - 59Minute of the time to set.
secondinteger0 - 59Second of the time to set.

Returns the current real-time clock time. The manual shows the typical return as hour, minute, and second values in signed numeric format.

string - Returns the current time as <hour>,<minute>,<second>.

Returns the SCPI version that the instrument complies with. Cannot be determined from the front panel.

string - The SCPI version.
SYST:VERS?

Sets the current reference down programming slew. The slew-rate setting range is 0.0001 to 999.99 A/ms in steps of 0.0001 A/ms.

NameTypeValuesDescription
NRf+real0.0001 - 999.99Current reference down programming slew rate.

Sets the current reference up programming slew rate. The slew rate setting range is 0.0001 to 999.99 A/ms in steps of 0.0001 A/ms.

NameTypeValuesDescription
slew ratereal0.0001 - 999.99Current reference up programming slew rate.
[SOURce]:CURRent:SLEW:UP <NRf+>

Enables or disables the digital current limit while in analog control mode. If enabled, the current programmed via the rear panel analog control signal is limited to no more than the digital current programming value.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables the digital current limit in analog control mode.

Enables or disables the digital current limit while in analog control mode. If enabled, the current programmed via the rear panel analog control signal is limited to no more than the digital current programming value.

enum - Returns whether the digital current limit is enabled or disabled.

Turns on or off analog programming of current, and selects the type of analog programming. Current is controlled by SCPI/front panel when OFF, by an analog voltage signal when VOLTage, or by an analog resistance when RESistance.

NameTypeValuesDescription
modeenumOFF | VOLTage | RESistanceSelects the type of analog programming or disables analog current programming.

Turns on or off analog programming of current and selects the type of analog programming. Current can be controlled by SCPI/front-panel setting, an analog voltage signal, or an analog resistance.

enum - Returns the current analog current source setting.

Sets the transient mode for current output. This determines what happens to the output current when the transient system is initiated and triggered.

NameTypeValuesDescription
modeenumFIXed | STEP | LISTTransient mode selection.

Sets the transient current mode used when the transient system is initiated and triggered. The mode determines whether the output current stays fixed, steps to a triggered level, or follows a list.

enum - Returns the present transient mode.

Sets the over-current protection delay. The over-current protection function will not be triggered during the delay time, which prevents momentary changes in output status from triggering protection.

NameTypeValuesDescription
delayreal0.1 - 25.5Protection delay time.
qualifieroptenumMIN | MAXSelects the minimum or maximum allowed delay value.
CURR:PROT:DEL 0.2

Sets the over-current protection delay. The over-current protection function will not be triggered during the delay time, and becomes active after the delay expires.

NameTypeValuesDescription
delayreal0.1 - 25.5Protection delay time.
real (s) - Returns the protection delay value.
CURR:PROT:DEL 0.2

Enables or disables the over-current protection. If enabled and the output goes into constant current operation, the output is disabled and the Questionable Condition status register OCP bit is set.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables the over-current protection.
enum - Returns the current protection state as 0 or 1.
CURR:PROT:STAT ON

Enables or disables the over-current protection. If enabled and the output goes into constant current operation, the output is disabled and the Questionable Condition status register OCP bit is set.

enum - Returns the current protection state as 0 or 1.
CURR:PROT:STAT ON

Sets the triggered current level. The triggered level is a stored value transferred to the output when an output step is triggered. Units are in amperes; the maximum value depends on the current rating of the unit.

NameTypeValuesDescription
valuereal0 - 105% of ratingTriggered current level to set.
qualifieroptenumMINimum | MAXimumSets the minimum or maximum current level.
CURR:LEV:TRIG 3

Returns the triggered current level. Units are in amperes, and the value depends on the unit's current rating.

NameTypeValuesDescription
qualifieroptenumMIN | MAXSelects the minimum or maximum triggered current level.
real (A) - Triggered current level in amperes.

Sets the immediate or triggered current level. Units are in amperes, and the maximum value depends on the current rating of the unit.

NameTypeValuesDescription
currreal0 - 105% of ratingCurrent level to set for the immediate or triggered output current level.
qualifieroptenumMIN | MAXUse MIN or MAX to set the current level to the minimum or maximum allowed value.
CURR 3

Returns or sets the immediate current level. Units are in amperes, and the maximum value depends on the current rating of the unit.

NameTypeValuesDescription
qualifieroptenumMIN | MAXSelects the minimum or maximum allowable current level.
real (A) - Returns the current level.
CURR 3

Sets the negative current slew rate. The slew rate is specified in amps per second and can be set from 0.1 to 9.9999E+5, or to the maximum value with MAX.

NameTypeValuesDescription
slewreal0.1 - 9.9999E+5Current slew rate to set.
qualifieroptenumMIN | MAXOptional keyword qualifier for minimum or maximum slew rate.
[SOURce:]CURRent:SLEW:NEGative[:IMMediate] <slew>

Sets the current slew rate in amps per second. The value can be set from 0.1 to 9.9999E+5, with MAX setting the maximum slew rate.

NameTypeValuesDescription
slewreal0.1 - 9.9999E+5Current slew rate to set.
qualifieroptenumMIN | MAXOptional keyword qualifier for the slew rate value.
CURR:SLEW 0.5

:LIST:VOLTset / query

Programs the voltage levels for an output list. The values are entered in step order; if only one value is supplied, it is applied to all steps in the list.

NameTypeValuesDescription
voltagerealVVoltage level for each list step.
LIST:VOLT 15,0
LIST:VOLT 9,0,6,0,3,0
:LIST:DWELset / query

Programs the dwell times for the list steps. The dwell values determine how long the output remains at each step before advancing to the next step.

NameTypeValuesDescription
dwellrealsDwell time for each list step, specified as a comma-separated list of values.
LIST:DWEL 1,2
LIST:DWEL 2,3,5,3,7,3
:LIST:STEPset / query

Selects whether the list advances in dwell-paced or trigger-paced mode. The default is dwell-paced.

NameTypeValuesDescription
modeenumAUTO | ONCEList pacing mode: AUTO for dwell-paced, ONCE for trigger-paced.
LIST:STEP AUTO
LIST:STEP ONCE
:LIST:COUNset / query

Specifies how many times the list (or pulse) repeats. At reset, the list count is 1 repetition; sending INFinity makes the list repeat indefinitely.

NameTypeValuesDescription
countinteger1Number of times the list or pulse repeats.
LIST:COUN 2

Sets the number of times the list is executed before it is completed. The repeat count range is 1 through 9999, or INFinity.

NameTypeValuesDescription
repeatcountintegerINFinityNumber of times the list is executed before completion.
LIST:COUN 10

Sets or queries how many times the current list is executed before completion. A returned value of 9.9E37 indicates continuous repetition.

NameTypeValuesDescription
qualifieroptenumMIN | MAXOptional query qualifier.
integer - The list repeat count; 9.9E37 means repeat continuously.
Sets the list count to 10: LIST:COUN 10

Specifies the current setting for each corresponding list step in amperes. A comma-delimited list of up to 100 steps may be programmed.

NameTypeValuesDescription
currreal0 - 105% of current ratingCurrent level for each list step.
string - The programmed current level in the form +n.nnnnnnE+nn; multiple responses are separated by commas.
LIST:CURR 3, 2, 1

Returns the programmed current level list for each corresponding list step. Multiple responses are separated by commas and the values are returned in exponential format.

real (A) - The programmed current level list, with one value per list step. Multiple responses are separated by commas.

Specifies the voltage setting for each corresponding list step. A comma-delimited list of up to 100 steps may be programmed.

NameTypeValuesDescription
voltreal0 - 105% of current or voltage ratingVoltage level for each list step.
LIST:VOLT 30, 35, 40. 45, 50

Specifies the voltage setting for each corresponding list step in volts. A comma-delimited list of up to 100 steps may be programmed, and the query returns the programmed voltage levels.

real (V) - Returns the programmed voltage level(s) in the form +n.nnnnnnE+nn; multiple responses are separated by commas.
LIST:VOLT 30, 35, 40. 45, 50

Returns the number of points in the specified list. Points are the same as steps, and the query does not return the point values.

integer - The number of points in the current list.

Specifies the dwell time for each list step. A comma-delimited list of up to 100 steps may be programmed; dwell times can be set from 0.001 to 129600 seconds.

NameTypeValuesDescription
timereal0.001 - 129600Dwell time for each list step.
LIST:DWEL 0.4,0.8,1.6

Returns the number of points in the specified dwell list. Points are the same as steps, and the query does not return the point values.

integer - The number of points in the current dwell list.

Returns the programmed dwell times for the list. Multiple responses are separated by commas.

string - The programmed dwell times, returned as +n.nnnnnnE+nn values separated by commas.
[SOURce:]LIST:DWELl?

Specifies how the list responds to triggers. ONCE keeps the output at the present step until a trigger advances it, while AUTO automatically advances through the steps after an initial starting trigger.

NameTypeValuesDescription
modeenumONCE | AUTOList step response to triggers.
LIST:STEP ONCE

Specifies how the list responds to triggers. ONCE keeps the output at the present step until a trigger advances it; AUTO advances automatically after an initial starting trigger, paced by the dwell list.

enum - Returns the current list step setting.
LIST:STEP ONCE

Returns the number of points in the specified list. Points are the same as steps, and the query does not return the point values.

integer - Number of points in the current list.
:LIST:CURRset / query

Sets the low and high current values used by the list generator for the transient response test.

NameTypeValuesDescription
low_valuereal-Low current value for the list waveform.
high_valuereal-High current value for the list waveform.
LIST:CURR <low_value>,<high_value>

Programs the list-generated trigger signal function for routing trigger signals to other destinations, such as external equipment connected to the digital port.

Sets the polarity of the rear panel ENA signal. The setting is stored in non-volatile memory.

NameTypeValuesDescription
polarityenumPOSitive | NEGativeSelects whether the ENA signal inhibits the output when Low or when High.

Returns or sets the polarity of the rear panel ENA signal. NEGative inhibits the output when ENA is low, and POSitive inhibits the output when ENA is high.

enum - Returns the current ENA signal polarity.

Controls the digital output pins on rear panel connector J1. Bit 0 of <data> controls J1 pin 21 and bit 1 controls J1 pin 20; each output is open-drain.

NameTypeValuesDescription
datainteger0 - 3Two-bit digital data that sets the rear-panel digital output pins.

Controls the digital output pins on rear panel connector J1. Bit 0 of <data> controls J1 pin 21 and bit 1 controls J1 pin 20.

integer - Returns the current 2-bit digital output data value.

Sets the operation of the Trigger Out signal (J1 pin 23). In FIXed mode, TRIG generates a trigger pulse when the output state changes and FSTR generates one whenever an output parameter is programmed; in LIST mode, TRIG generates a pulse when the list has completed and FSTR generates one each time a list step has completed.

NameTypeValuesDescription
modeenumOFF | FSTR | TRIGTrigger Out function mode.
[SOURce:]:DIGital:PTRG:FUNCtion OFF|FSTR|TRIG

Sets the operation of the Trigger Out signal (J1 pin 23). In TRIG mode, a trigger pulse is generated when the output state changes or when the list has completed; in FSTR mode, a trigger pulse is generated whenever an output parameter is programmed or each time a list step has completed.

enum - Returns the current Trigger Out operation mode.

*TRGset / query

Sends a trigger to the instrument.

*TRG
*CLSset / query

Clears the event registers in all register groups, the Status Byte, and the Error Queue. If it immediately follows a program message terminator, it also clears the Output Queue and MAV bit.

*CLS
*ESEset / query

Enables bits in the Standard Event Status group enable register. The query reads back the current enable register as a decimal value representing the binary-weighted sum of all bits set.

NameTypeValuesDescription
valueinteger0 - 255Bits to enable in the Standard Event Status Enable register.
integer - Decimal value corresponding to the binary-weighted sum of all bits set in the enable register.
*ESE <value>
*ESE?
*ESE?query

Enables bits in the Standard Event Status group enable register. The query reads back the enable register as a decimal value corresponding to the binary-weighted sum of all set bits.

NameTypeValuesDescription
valueinteger0 - 255Bit mask for the Standard Event Status enable register.
integer - Decimal value corresponding to the binary-weighted sum of all bits set in the enable register.
*ESR?query

Queries the Standard Event Status register. The event register is read-only and latches standard events until cleared by this query or *CLS.

integer - Binary-weighted sum of all bits set in the event register.
*ESR?
*OPCset / query

Sets the OPC (operation complete) bit in the Standard Event register when the current operation completes. It is used to synchronize an application with the instrument.

*OPC
*OPC?query

Returns a 1 to the output buffer when all pending operations complete. The response is delayed until all pending operations complete, and other commands cannot be executed until this command completes.

integer - Returns 1 when the current operation completes and all pending operations are complete.
*OPC?
*SREset / query

Sets the Service Request Enable register and determines which Status Byte Register bits contribute to the MSS and RQS summary bits. The query reads back the current register value as a decimal number.

NameTypeValuesDescription
valueinteger-Decimal value corresponding to the binary-weighted sum of the bits in the register.
integer - Current state of the Service Request Enable register, returned as a decimal value corresponding to the binary-weighted sum of all bits set in the register.
*SRE 24
*SRE?query

Sets the value of the Service Request Enable register. The query reads the current state of the register and returns a decimal value corresponding to the binary-weighted sum of all bits set in the register.

NameTypeValuesDescription
valueinteger0 - 255Decimal value that corresponds to the binary-weighted sum of the bits in the Service Request Enable register.
integer - Decimal value corresponding to the binary-weighted sum of all bits set in the Service Request Enable register.
*SRE 24
*STB?query

Reads the Status Byte Register, which contains the status summary bits and the Output Queue MAV bit. The register is read-only; reading it does not clear the input bits.

integer - Returns the Status Byte register value as a bit value; during a serial poll, bit 6 returns RQS instead of MSS.
*STB?
*WAIset / query

Pauses additional command processing until all pending operations are complete. It can only be aborted by sending the instrument a command.

*WAI
*IDN?query

Returns the instrument identification string.

string - Returns the instrument identification string.
*LRN?query

Returns the instrument state generated by the last *RST, *CLS, or power-on state save operation. The returned string can later be used to restore the state with *RCL or *SAV-related functions.

string - Returns the last learned state string.
*OPT?query

Returns the instrument option identification string.

string - The instrument option identification string.
*RCLset / query

Recalls the state stored in the specified memory location. This is a common command used for system functions.

NameTypeValuesDescription
locationinteger0 - 9Memory location to recall.
*RSTset / query

Resets the instrument to its power-on state.

*SAVset / query

Stores the current instrument state in the specified non-volatile memory location.

NameTypeValuesDescription
locationinteger0 - 9Memory location to store the current state.
*TST?query

Returns the instrument's self-test result. This is a common command and does not accept parameters.

integer - Returns the self-test result code.
*PONset / query

The output may be enabled at turn-on depending on this setting. Check it before attaching anything to the output terminals.

:TRIG:SOURset / query

Selects the trigger source for the trigger system. The example shows BUS as the trigger source.

NameTypeValuesDescription
sourceenumBUSTrigger source.
TRIG:SOUR BUS
:TRIG:TRANset / query

Triggers the transient system during the transient recovery time test procedure.

Cancels any pending triggered actions. Abort commands control the remote triggering of the instrument's output.

ABORt
ABOR

Sets the full-scale analog programming and monitor range. Programming uses 5/10 Volts or 5/10 kΩ; monitoring uses 5/10 Volts.

NameTypeValuesDescription
rangeinteger5 - 10Selects the full-scale analog range.

Turns the front panel display and the front panel buttons on or off. It does not affect the power switch.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONTurns the display and front panel buttons off or on.
DISP OFF

Turns the front panel display and the front panel buttons on or off. It does not affect the power switch.

integer - Returns the display state as 0 or 1.
DISP OFF

Starts or stops flashing of the LAN annunciator on the front panel display to help identify the device associated with a LAN address.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONEnables or disables the LAN annunciator flash.
LXI:IDENtify:STATe 0|OFF|1|ON
LXI:IDENtify:STATe?

Starts or stops flashing of the LAN annunciator on the front panel display to help identify the device associated with a LAN address.

integer - Returns 0 or 1.

Returns the instrument's Multicast Domain Name System (mDNS) host name.

string - The instrument's mDNS host name.

Returns the instrument's Multicast Domain Name System (mDNS) service name.

string - The instrument's Multicast Domain Name System (mDNS) service name.

Enables or disables the Multicast Domain Name System (mDNS).

NameTypeValuesDescription
stateoptenum0 | OFF | 1 | ONEnables or disables mDNS.

Enables or disables the Multicast Domain Name System (mDNS).

enum - Returns the mDNS state.
:LXI:RESetset / query

Resets LAN settings to a known operating state, including enabling DHCP. Restarts the LAN interface.

Initiates and triggers a current measurement, then returns the averaged output measurement. Measurement overflows return 9.91E+37.

real (A) - The averaged current measurement.

Initiates and triggers a power measurement, then returns the averaged output measurement. Measurement overflows return a reading of 9.91E+37.

real (W) - The averaged output power measurement.

Initiates and triggers a voltage measurement, then returns the averaged output measurement. Measurement overflows return 9.91E+37.

real (V) - The averaged output voltage measurement.

Enables or disables the ENA function on the rear panel (J1 pin 10). When disabled, the instrument ignores the ENA signal; the setting is stored in non-volatile memory.

NameTypeValuesDescription
modeenumLATChing | OFFSelects whether the rear-panel ENA function is latched or disabled.

Enables or disables the rear-panel ENA (enable) function on J1 pin 10. When disabled, the instrument ignores the ENA signal; the setting is stored in non-volatile memory.

enum - Returns the current inhibit mode.
:OUTPut[:STATe]set / query

Enables or disables the output. A disabled output is a condition of zero output voltage and zero current.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONTurns the output off or on.
enum - Returns the output state as 0 or 1.
OUTP OFF

Enables or disables the output. A disabled output is a condition of zero output voltage and zero current.

enum - Returns the present output state.
OUTP OFF

Enables or disables the ILC (interlock) function on the rear panel. When disabled, the instrument ignores the ILC signal; the setting is stored in non-volatile memory.

enum - Returns the current ILC interlock state.

Enables or disables the ILC (interlock) function on the rear panel of the instrument. When disabled, the instrument ignores the ILC signal; the setting is stored in non-volatile memory.

NameTypeValuesDescription
stateoptenum0 | OFF | 1 | ONEnables or disables the interlock function.

Sets the output power-on state. This determines whether the power-on state is set to the *RST state or the state stored in memory location 0.

NameTypeValuesDescription
stateenumRST | RCL0Selects whether the instrument powers on in the *RST state or recalls the state stored in memory location 0.

Sets the output power-on state. This determines whether the power-on state is set to the *RST state or the state stored in memory location 0.

enum - Returns the output power-on state.

Sets or queries the output preload state. Preload controls how the supply behaves when the output is turned off: off for 7 seconds then zero current, or on continuously while output is off.

NameTypeValuesDescription
stateoptenum0 | OFF | 1 | ONEnables or disables preload.
enum - Returns the preload state as 0 or 1.

Preload determines the power supply’s behavior when the output is in the off state. With preload off, the unit draws down-programming current for 7 seconds after the output is turned off; with preload on, it draws down-programming current continuously while the output is off.

NameTypeValuesDescription
stateenum0 | OFF | 1 | ONSets whether preload is off or on.
enum - Returns the current preload state as 0 or 1.

Clears the latched output protection status that disables the output when a protection condition occurs. The output is restored to the state it was in before the protection condition occurred.

OUTP:PROT:CLE

Selects which quantity is slewed: none, voltage, or current. Only one parameter at a time can be slewed; the setting applies to the corresponding source slew command.

NameTypeValuesDescription
modeenumNONE | VOLTage | CURRentSelects the slew function.

Selects which source quantity is slewed. Only one parameter at a time, either voltage or current, can be slewed.

enum - Returns the current slew function selection.

Queries the Condition register for the Operation status group. This is a read-only register that holds the live, unlatched operational status of the instrument and is not cleared by reading.

integer - Returns the binary-weighted sum of all bits set in the Operation Status Condition register.
STAT:OPER:COND?

Sets the enable register bits for the Operation status group. The enable register masks which bits from the Operation Event register can set the OPER summary.

NameTypeValuesDescription
valueinteger-Bit mask for the Operation status group enable register.

Sets or queries bits in the Enable register for the Operation status group. The enable register is a mask for enabling specific bits from the Operation Event register to set the OPER (operation summary) bit.

NameTypeValuesDescription
valueinteger-Bit mask for enabling specific bits from the Operation Event register.
integer - Returns the current contents of the Operation status Enable register as a bit value.

Queries the Event register for the Operation status group. This read-only register latches events passed by the Operation NTR and PTR filter, and reading it clears the register.

integer - Returns the binary-weighted sum of all bits set in the Operation status Event register.
STAT:OPER?

Sets or queries the value of the NTR (Negative-Transition) register. The register acts as a polarity filter between the Operation Condition and Operation Event registers.

NameTypeValuesDescription
valueinteger0Decimal value corresponding to the binary-weighted sum of the bits in the register.
STAT:OPER:NTR 24

Sets or queries the value of the NTR (Negative-Transition) register. The register acts as a polarity filter between the Operation Condition and Operation Event registers.

NameTypeValuesDescription
valueinteger-Decimal value corresponding to the binary-weighted sum of the bits in the register.
integer - Returns the binary-weighted sum of all bits set in the NTR register.
STAT:OPER:NTR 24
STAT:OPER:NTR?

Sets and queries the value of the PTR (Positive-Transition) register. This register serves as a polarity filter between the Operation Condition and Operation Event registers.

NameTypeValuesDescription
valueinteger-A decimal value that corresponds to the binary-weighted sum of the bits in the register.
integer - The binary-weighted sum of all bits set in the register.
STAT:OPER:PTR 24

Sets or queries the value of the PTR (Positive-Transition) register. This register acts as a polarity filter between the Operation Condition and Operation Event registers; bits set to 1 enable 0-to-1 transitions to set the corresponding event bit.

NameTypeValuesDescription
valueinteger-Decimal value corresponding to the binary-weighted sum of the bits in the register.
integer - Decimal value corresponding to the binary-weighted sum of all bits set in the PTR register.
STAT:OPER:PTR 24
STATus:OPERation:PTRansition?
:STATus:PRESetset / query

Presets the Status subsystem registers. It presets the Operation and Questionable Enable, PTR, and NTR registers; all defined bits are disabled for the enable registers and enabled for the PTR registers.

Queries the Questionable status group Event register. Reading the register clears it; the value returned is the binary-weighted sum of all bits set.

integer - Binary-weighted sum of all bits set in the Questionable status Event register.
STAT:QUES?

Queries the Condition register for the Questionable status group. It returns the live, unlatched operational status; reading it does not clear the register.

integer - Binary-weighted sum of all bits set in the Questionable status condition register.
STAT:QUES:COND?

Sets and queries bits in the Enable register for the Questionable status group. The enable register is a mask for enabling specific bits from the Operation Event register to set the QUES summary bit of the Status Byte register.

NameTypeValuesDescription
valueinteger-Decimal value corresponding to the binary-weighted sum of the bits in the register.
STAT:QUES:ENAB 24

Sets and queries bits in the Enable register for the Questionable status group. The enable register is a mask for enabling specific bits from the Operation Event register to set the QUES summary bit of the Status Byte register.

NameTypeValuesDescription
valueinteger-A decimal value that corresponds to the binary-weighted sum of the bits in the register.
integer - Returns the enable register value as a bit value.
Enable bit 2 and 4 in the questionable enable register: STAT:QUES:ENAB 24

Sets and queries the value of the NTR (Negative-Transition) register for the Questionable status group. This register serves as a polarity filter between the Questionable Condition and Questionable Event registers.

NameTypeValuesDescription
valueinteger0Decimal value corresponding to the binary-weighted sum of the bits in the register.
STAT:QUES:NTR 24
STAT:QUES:NTR?

Sets and queries the value of the NTR (Negative-Transition) register for the Questionable status group. The register serves as a polarity filter between the Questionable Condition and Questionable Event registers.

NameTypeValuesDescription
valueinteger-Decimal value corresponding to the binary-weighted sum of the bits in the register.
integer - Returns the value of the NTR register as a binary-weighted bit value.
STAT:QUES:NTR 24
STAT:QUES:NTR?

Sets the bits in the Questionable PTR register. A bit set to 1 enables a 0-to-1 transition of the corresponding Questionable Condition bit to set the matching Questionable Event bit.

NameTypeValuesDescription
bit valueinteger0 - 4294967295A decimal value corresponding to the binary-weighted sum of the bits to set in the register.

Sets or queries the positive transition bits in the Questionable PTR register. The returned value is the binary-weighted sum of all bits set in the register.

integer - A decimal value corresponding to the binary-weighted sum of the bits set in the register.
STAT:QUES:PTR 24

Sets the bandwidth level used for the diagnostic output current step in the transient response test. In the example, level 3 generates a 40 us risetime step in the load list.

NameTypeValuesDescription
levelinteger0 - 3Bandwidth level for the diagnostic output current step.
DIAG:OF:CURR:BWID:LEV 3

:FUNC:CURRset / query

Specifies current priority for the load list generator.

FUNC:CURR