Sets the vertical position of the FFT waveform. The FFT window can be positioned using the vertical Offset/Position control.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Vertical position of the FFT waveform. |
SCPI COMMAND REFERENCE
The Rohde & Schwarz ROHDE-SCHWARZ-RTM3002 is Rohde & Schwarz's oscilloscope in the RTM3000 family. Its SCPI remote-control interface exposes 1634 commands across 43 subsystems - 978 settable and 656 queries - and every command is documented here with its parameters, accepted values, return format, and a copy-paste PyVISA example for automating test and measurement.
1,634
Commands
978
Settable
656
Queries
43
Subsystems
SCPI
Verified
2026-07-16
Sets the vertical position of the FFT waveform. The FFT window can be positioned using the vertical Offset/Position control.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Vertical position of the FFT waveform. |
Sets the FFT spectrum frequency scale in the spectrum window. The FFT frequency range can also be adjusted by center/span or start/stop frequencies.
Defines the frequency in the center of the displayed span. The instrument adjusts the start and stop frequencies.
Defines the width of the displayed frequency range in the FFT spectrum. The span is specified in hertz and the instrument adjusts the start and stop frequencies accordingly.
| Name | Type | Values | Description |
|---|---|---|---|
| span | real | Hz | Width of the displayed frequency range. |
Defines the start frequency of the FFT waveform. The instrument adjusts the span and center frequency, and optimizes the time gate.
Defines the stop frequency of the displayed frequency span. The instrument adjusts the span and the center frequency, and optimizes the time gate and the acquisition time (timebase).
Sets the RBW ratio for FFT analysis. If Automatic RBW is selected, the RBW value is adjusted automatically; when RBW is set manually, the instrument adjusts the time gate.
| Name | Type | Values | Description |
|---|---|---|---|
| ratio | real | 0.01 - 10 | RBW ratio for FFT analysis. |
Sets the FFT RBW value. When Automatic RBW is selected, the value is adjusted automatically; when set manually, the instrument adjusts the time gate.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | RBW value. |
Selects the channel used for FFT analysis. You can choose one of the active input channels, math waveforms, or reference waveforms.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Channel or waveform source for FFT analysis. |
Shows the position of the time gate used for FFT analysis. The position is an offset of the time gate center to the 0 s reference point, and it can be changed when Automatic RBW is disabled.
Sets the width of the time gate for which FFT is calculated. The value can be changed only if Automatic RBW is disabled; when changed, the RBW value is adjusted automatically.
| Name | Type | Values | Description |
|---|---|---|---|
| time gate width | real | - | Width of the time gate for which FFT is calculated. |
Selects the FFT window function used for spectrum analysis. The available window types are Hanning, Hamming, Blackman, Flat Top, and Rectangle.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | Hanning | Hamming | Blackman | Flat Top | Rectangle | FFT window function to use. |
Selects the Spectrum waveform averaging display. The average value for each frequency in the waveform over the specified number of averages is calculated.
Selects the Max Hold waveform type to be displayed in FFT analysis. The maximum value for each frequency over all FFTs is displayed.
| Name | Type | Values | Description |
|---|---|---|---|
| enableopt | enum | ENABle | Enables the Max Hold waveform type. |
Selects the Min Hold FFT waveform for display. The minimum value for each frequency over all FFTs is displayed.
Selects the Spectrum waveform type to be displayed. The Spectrum waveform shows the current value for each frequency, and can be enabled as one of several waveform types displayed in parallel.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the Spectrum waveform type. |
Sets the number of averages used for spectrum frequency averaging.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 | Number of averages to use. |
Defines the scaling unit for the vertical scale in spectrum frequency magnitude display. The displayed values refer to a 50 Ohm terminating resistor.
| Name | Type | Values | Description |
|---|---|---|---|
| scale | enum | dBm | dBV | dBμV | Veff | Vertical scale unit. |
Resets the spectrum frequency settings to their default state.
Enables or disables the spectrogram.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | on | off | Turns the spectrogram on or off. |
Enables or disables automatic RBW selection. If enabled, the instrument sets an appropriate resolution bandwidth; if disabled, a manual value can be set.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns automatic RBW selection on or off. |
Enables the peak search and displays the peak list and markers.
Defines the waveform type that is searched for peaks.
Defines a minimum level difference between two subsequent peaks that must be maintained for a peak to be detected. To avoid identifying noise peaks, enter an excursion value higher than the noise levels.
Defines the minimum absolute level for peak detection. Only peaks that exceed the minimum level are detected, listed in the Peak List, and marked in the spectrum diagram.
Enables a more precise peak detection. For a peak to be detected, the Excursion, Max. Width and Distance have to be within the defined limits.
Defines the maximum width that a peak can have for it to be detected.
Defines the number of the peak to which the reference marker is set when R-Marker is set to "Indicated".
| Name | Type | Values | Description |
|---|---|---|---|
| index | integer | - | Peak number used for the reference marker selection. |
Defines the mode for selecting the reference peak used by the R-Marker. The reference marker can be turned off, set to a peak by index, or set to the highest peak within a specified range.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | Off | Indicated | Range | Selects how the reference peak is chosen. |
Defines the center frequency for the capture range when the reference marker mode is set to "Range".
| Name | Type | Values | Description |
|---|---|---|---|
| distance | real | - | Center frequency for the capture range. |
Sets the highest detected peak to the center of the display.
Sets the reference marker center frequency to the center of the display.
Sets the reference marker setup frequency. The slice only names the remote command and provides no syntax, parameter details, or return value.
Defines the frequency range around the center frequency if "R-Marker" = "Range".
Sets which result values are shown in the peak list. The values can be absolute or relative to the reference marker.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | Absolute | R-Marker Frequency | R-Marker Level | R-Marker Freq. & Level | Defines whether the peak list shows absolute values or values relative to the reference marker. |
Selects a color scale for the frequency-domain diagram. When Magnitude Mode is off, the spectrum and spectrogram can use separate color scales.
| Name | Type | Values | Description |
|---|---|---|---|
| scheme | enum | Rainbow | Temp. Color | Color scale to use. |
Selects a color scale for the spectrogram. The spectrogram and spectrum may share the same color scale when Magnitude Mode is on; the available scales include Rainbow and Temp. Color.
Enables or disables magnitude-dependent coloring of the waveform. When disabled, the color depends on the frequency of occurrence of a value.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | on | off | Turns magnitude-dependent coloring on or off. |
Sets the level used as the maximum for the selected color scale. Values above the maximum are displayed with the maximum color.
| Name | Type | Values | Description |
|---|---|---|---|
| levelopt | real | - | Maximum level for the color scale. |
Sets the minimum level used for the color scale in the spectrum diagram. Values below the minimum are displayed with the minimum color.
| Name | Type | Values | Description |
|---|---|---|---|
| levelopt | real | - | Minimum level for the color scale. |
Returns whether frequency averaging is complete.
Sets the spectrum display to full span. The command is listed among other spectrum frequency setup commands.
Saves the current spectrum history to a file or location. The command belongs to the Spectrum History export group.
Clears all stored spectrum history entries. This is a setter command.
Sets the playback speed for spectrum history. The command belongs to the Spectrum History Player subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| speed | real | MINimum - MAXimum | Playback speed setting. |
Starts spectrum history acquisition.
Stops spectrum history acquisition.
Returns the absolute time stamps for all history acquisitions in the spectrum history buffer.
Returns the absolute timestamp of the selected spectrum history entry.
Returns the date and time stamps of all spectrum history entries. The command is the "ALL?" variant of the spectrum history timestamp date query.
Returns the date and time stamp for the history entry. The command is a query and returns the timestamp in date format.
Returns the timestamp-relative history data for all history entries.
Returns the relative time stamp for the current spectrum history item.
Returns the marker count for the spectrum marker subsystem.
Returns the delta result for marker n in the all-results form. This is the query form of the marker result command.
Returns the results for marker <n> in the spectrum display.
Returns the delta result of marker <n> in the spectrum display.
Returns the frequency delta for marker result <n>.
Returns the frequency result for marker n in the spectrum marker results table.
Returns the level difference of marker <n>.
Returns the level result for marker n in the spectrum marker results. This is a query form of the marker result level command.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Marker result index n. |
Returns the result value of marker <n>.
Returns the frequency of the reference marker in the spectrum display.
Returns the relative marker level for the reference marker in the spectrum view.
Returns the marker frequency and level for the reference marker.
Enables or disables the spectrum marker function.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the spectrum marker on or off. |
Sets the spectrum mode. The command selects the mode used for spectrum measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Spectrum mode. |
Resets the spectrogram settings to their default state.
Sets the spectrogram scale. The command is listed without additional syntax or parameter details in this slice.
Returns the number of points in the averaged spectrum waveform data.
Returns the X increment for the spectrum waveform average data. The value is the spacing between X-axis data points.
Returns the Y-axis increment for the average spectrum waveform data.
Returns the Y-origin of the averaged waveform data. This query is part of the SPECtrum:WAVeform:AVERage:DATA family.
Returns the header information for the maximum spectrum waveform data. The command is a query and provides the header associated with :SPECtrum:WAVeform:MAXimum:DATA.
Returns the number of points in the maximum waveform data. The command is part of the spectrum waveform data query set.
Returns the X increment for the maximum waveform data. This is the spacing between successive X-axis data points.
Returns the Y increment for the maximum spectrum waveform data. This command is listed under the spectrum waveform data queries.
Returns the Y resolution of the maximum spectrum waveform data.
Returns header information for the minimum spectrum waveform data. The command is a query and yields the data header for the MINimum waveform selection.
Returns the number of points in the minimum spectrum waveform data. The command is the query form of the minimum spectrum waveform data points command.
Returns the Y increment of the minimum spectrum waveform data. This command is part of the spectrum waveform data access set.
Returns the header information for the spectrum waveform data. The command belongs to the spectrum waveform data queries.
Returns the X increment for the spectrum waveform data. This is the spacing between adjacent X values in the spectrum data set.
Returns the x-origin of the spectrum waveform data.
Returns the Y-origin value for the spectrum waveform data.
Returns the spectrum waveform data.
Enables or disables the spectrum display or selects a spectrum submode. The optional state node may be omitted in the command syntax.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | ON | OFF | Turns the spectrum state on or off. |
Specifies the afterglow duration used when persistence is set to Manual. Each new data point remains on the screen for the time defined here; the range is 50 ms to 12.8 s, with 50 ms as the default.
| Name | Type | Values | Description |
|---|---|---|---|
| time | real | 50 ms - 12.8 s | Afterglow duration for persistence in Manual mode. |
Defines the waveform persistence (afterglow effect) on the display. Persistence does not affect digital channels.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | Off | Manual | Infinite | Selects the persistence mode. |
Defines the brightness of the grid lines in the diagram. Enter a percentage between 0 and 100% to adjust the grid brightness directly; the default value is 50%.
| Name | Type | Values | Description |
|---|---|---|---|
| intensity | real | 0 - 100 | Grid brightness in percent. |
Defines the brightness of the waveform lines in the diagram. The value is entered as a percentage between 0 and 100% and the default is 50%.
| Name | Type | Values | Description |
|---|---|---|---|
| intensity | real | 0 - 100 | Waveform brightness in percent. |
Inverts the brightness level of the signals. Rare values are displayed brighter than frequent values, which can help detect rare values within the waveform when used with persistence.
If activated, only the individual data points are displayed. If deactivated, the data points are connected by a line.
Enables or disables track grid behavior. If enabled, the grid moves with the waveforms when their horizontal or vertical position is changed; if disabled, the grid remains centered.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the track grid function. |
Enables or disables the display of scale values and units for the x-axis and y-axis at the grid lines. Grid labels are enabled by default.
| Name | Type | Values | Description |
|---|---|---|---|
| enableopt | enum | ON | OFF | Enables or disables annotation display. |
Defines how the grid is displayed.
| Name | Type | Values | Description |
|---|---|---|---|
| style | enum | Lines | Reticle | Off | Selects the grid display style. |
Selects the language in which button labels and other screen information are displayed. The help is available only in English.
| Name | Type | Values | Description |
|---|---|---|---|
| language | enum | - | Language to display. |
Switches the date and time display in the upper right corner of the screen on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | on | off | Turns the date and time display on or off. |
Clears the display. If the optional screen node is present, the screen is cleared.
Closes the active dialog window.
Sets the message shown in the display dialog. The command is used to display a dialog message on the screen.
| Name | Type | Values | Description |
|---|---|---|---|
| message | string | - | Message text to be displayed in the dialog. |
Clears the display persistence data.
Sets the display persistence to infinite. Use this command to enable infinite persistence on the waveform display.
Sets or queries the display persistence state. The command is shown as an optional-node form under DISPlay:PERSistence.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | - | Persistence state. |
Sets the source signal for XY display mode.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Source signal for the XY display mode. |
Selects the source signal assigned to the Y1 axis in XY display mode.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Source assigned to the Y1 axis. |
Sets the current date in the instrument as part of the Date & Time setup dialog.
| Name | Type | Values | Description |
|---|---|---|---|
| date | string | - | Current date to be set. |
Sets the current time in the instrument. The command is part of the Date & Time settings.
| Name | Type | Values | Description |
|---|---|---|---|
| hour | integer | 0 - 23 | Hour of the day. |
| minute | integer | 0 - 59 | Minute of the hour. |
Selects the Internet protocol mode for the Ethernet interface. DHCP/Auto IP enables dynamic host configuration and automatic address assignment.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables DHCP/Auto IP. |
Shows or specifies the instrument's IP gateway used by the instrument. It is listed with the Ethernet IP, subnet mask, and DNS server settings.
Shows or specifies the instrument's IP address.
| Name | Type | Values | Description |
|---|---|---|---|
| address | string | - | The instrument's IP address. |
Shows or specifies the IP subnet mask used by the instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| subnet mask | string | - | The IP subnet mask used by the instrument. |
Specifies the IP port number for the instrument's Ethernet interface. The default is 5025.
| Name | Type | Values | Description |
|---|---|---|---|
| IP port number | integer | - | IP port number to use for the Ethernet interface. |
Shows the instrument's media access control (MAC) address and the VISA address used to address the instrument in remote control.
Enables automatic transfer speed selection and shows the currently selected value. Alternatively, you can select one of the predefined settings that corresponds to the network data rate.
| Name | Type | Values | Description |
|---|---|---|---|
| transfer speed | enum | - | Transfer speed setting. |
Specifies the VXI-11 port number. The default is 1024.
| Name | Type | Values | Description |
|---|---|---|---|
| port | integer | - | VXI-11 port number. |
Deletes the password of the education mode.
Sets the beeper control state.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | Beeper control state. |
Sets the beeper state for error messages.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the error beeper. |
Sets the state of the trigger beeper.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the trigger beeper on or off. |
Sounds the system beeper immediately. This is the immediate form of the system beeper command.
Sets the HTTP port used for the Ethernet interface.
| Name | Type | Values | Description |
|---|---|---|---|
| port | integer | 1 - 65535 | HTTP port number. |
Sets the USB class used by the instrument's communication interface.
Selects the interface used for communication. The command is also documented with an optional node form, :SYSTem:COMMunicate:INTerface[:SELect].
Returns all entries from the error queue. Each error message is returned in sequence.
Returns the next error message from the system error queue. If the queue is empty, the response indicates no error.
Resets the instrument to its preset state.
Sets the system date and time. The command is listed in the system command overview.
Returns the command tree of the instrument as a list of command mnemonics.
Selects the measurement type for the switching loss measurement. The measurement results are displayed in W for power and in J for energy.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | power | energy | Measurement type for the switching loss measurement. |
Restarts the SOA measurement.
Sets the minimum current for the selected point.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Point index to be defined. |
Sets the voltage for the selected point.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Point index placeholder in the command mnemonic. |
| voltage | real | - | Voltage for the selected point. |
Sets the minimum current for the selected point.
Sets the voltage for the selected point.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Selects the point to be defined. |
Adds a point to the safe operating area definition list.
Adds a point to the safe operating area definition list.
Sets the current value of a point in the linear safe operating area definition list. The command is part of the SOA point definition for the linear power path.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Point index in the linear SOA definition list. |
| current | real | - | Current value for the specified point. |
Returns the current value for point m in the linear safe operating area definition list.
Removes the selected point from the safe operating area definition list.
Adds a point to the safe operating area definition list.
Adds a point to the safe operating area definition list.
Sets the current value of point m in the logarithmic safe-operating-area definition list.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | 1 | Point index in the safe-operating-area definition list. |
Sets the current maximum value for a logarithmic safe-operating-area point. The command belongs to the power analysis safe operating area definition list.
Removes the selected point from the safe operating area definition list.
Selects the scale for the mask, either linear or logarithmic.
| Name | Type | Values | Description |
|---|---|---|---|
| scale | enum | LINear | LOGarithmic | Scale for the mask. |
Sets the allowed acquisition tolerance.
| Name | Type | Values | Description |
|---|---|---|---|
| tolerance | real | - | Allowed acquisition tolerance. |
Sets the allowed total tolerance.
| Name | Type | Values | Description |
|---|---|---|---|
| tolerance | real | - | Allowed total tolerance. |
Selects a linear or logarithmic scale for the displayed results.
Sets the type of power analysis measurement.
Performs an autoset of the voltage and current source scales.
Performs an autoset of the current source scale.
Performs an autoset of the voltage source scale.
Enables or disables the power analysis measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns power analysis measurements on or off. |
Displays or hides the result table. The command is available for harmonic and spectrum power measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| visible | enum | ON | OFF | Controls whether the result table is shown or hidden. |
Sets the channel for the current source. Connect the current probe in flow direction of the current.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Channel number for the current source. |
Starts the automatic deskew procedure to align the waveforms of all visible channels. It is necessary when a current and a voltage probe are used in the measurement.
Sets the channel for the voltage source. The suffix <n> selects which voltage source is affected.
| Name | Type | Values | Description |
|---|---|---|---|
| <VoltageSource> | enum | CH1 | CH2 | CH3 | CH4 | RE1 | RE2 | RE3 | RE4 | Channel to use as the voltage source. |
Deletes the statistical results for the current measurement or all measurements, respectively, and starts a new statistical evaluation.
Shows or hides the statistical evaluation of the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| Visible | enum | ON | OFF |
Executes a zero offset for all visible channels.
Adds a power report.
Sets a description that can be shown at the title page of a report.
| Name | Type | Values | Description |
|---|---|---|---|
| DescriptionString | string | - | Description text to be shown on the report title page. |
Sets a device under test (DUT) value that can be shown at the title page of a report.
| Name | Type | Values | Description |
|---|---|---|---|
| DeviceString | string | - | Device under test value to show on the report title page. |
Sets the directory for the output folder where the reports are stored.
| Name | Type | Values | Description |
|---|---|---|---|
| OutputFolderPath | string | - | Directory path for the report output folder. |
Sets a site value that can be shown at the title page of a report.
| Name | Type | Values | Description |
|---|---|---|---|
| SiteString | string | - | Site value to be shown at the title page of a report. |
Sets a temperature value that can be shown at the title page of a report.
| Name | Type | Values | Description |
|---|---|---|---|
| temperature | string | - | Temperature value to include on the report title page. |
Starts the consumption measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Starts or stops the consumption measurement. |
Adds the result to the report list.
Restarts the consumption measurement.
Queries the apparent power, the magnitude of the vector sum of real and reactive power.
Sets a user value that can be shown at the title page of a report.
| Name | Type | Values | Description |
|---|---|---|---|
| UserString | string | - | User value to be shown on the title page of a report. |
Queries the duration of the measurement. The result is displayed in seconds.
Queries the energy.
Queries the power factor, a measure of the system efficiency. The value varies between -1 and 1.
Queries the phase angle, the angle between the current and the voltage sine waves.
Queries the reactive power, the power flow that is temporarily stored in a system because of the inductive and capacitive elements.
Queries the real power.
Starts the dynamic on resistance measurement.
Sets the start time for the corresponding gate.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 - 2 | Gate index. |
Sets the stop time for the corresponding gate.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 - 2 | Gate index. |
Adds the result to the report list.
Starts the dynamic on resistance measurement.
Starts the efficiency measurement.
Adds the current efficiency measurement result to the report list.
Returns the average efficiency measurement result. Query only.
Returns the negative peak efficiency result. Query only.
Returns the peak-to-peak efficiency result from the efficiency measurement. Query only.
Returns efficiency result values from the power efficiency measurement. The `:ACTual` form returns the current measured value.
Returns the corresponding statistic result for the efficiency. The statistic can be the current result, average, negative peak, positive peak, standard deviation, or waveform count depending on the suffix used.
Returns the number of waveforms used for the displayed efficiency results. Query only.
Returns the corresponding statistic result for the input real power. The manual lists the available statistic forms for this measurement result, including current, average, peak, standard deviation, and waveform count variants.
Returns the corresponding statistic result for the input real power. The manual lists the available statistic forms for this result family, including NPEak for the negative peak value.
Returns the corresponding statistic result for the input real power. The available statistic suffixes are current, average, negative peak, positive peak, standard deviation, and waveform count.
Returns the corresponding statistic result for the input real power. The statistic selector may be ACTual, AVG, NPEak, PPEak, STDDev, or WFMCount.
| Name | Type | Values | Description |
|---|---|---|---|
| statistic | enum | ACTual | AVG | NPEak | PPEak | STDDev | WFMCount | Statistic to return. |
Returns the corresponding statistic result for the input real power.
| Name | Type | Values | Description |
|---|---|---|---|
| WFMCount | enum | WFMCount | Selects the waveform-count statistic. |
Returns the corresponding statistic result for the input real power. The slice documents the current measurement result form and statistic forms such as average, negative peak, positive peak, standard deviation, and waveform count.
| Name | Type | Values | Description |
|---|---|---|---|
| qualifieropt | enum | ACTual | AVG | NPEak | PPEak | STDDev | WFMCount | Selects which statistic result is returned. |
Returns the corresponding statistic result for the output real power. The available statistic selectors include current result, average, negative peak, positive peak, standard deviation, and waveform count.
| Name | Type | Values | Description |
|---|---|---|---|
| statistic | enum | [:ACTual] | AVG | NPEak | PPEak | STDDev | WFMCount | Selects which statistic result is returned. |
Returns the corresponding statistic result for the output real power. The manual lists this query under the power efficiency results, with the statistic selected by the suffix on the command.
Returns the corresponding statistic result for the output real power. The available statistic selectors include current, average, negative peak, positive peak, standard deviation, and waveform count.
Returns the corresponding statistic result for the output real power. The page lists query variants for current, average, negative peak, positive peak, standard deviation, and waveform count results.
| Name | Type | Values | Description |
|---|---|---|---|
| qualifier | enum | ACTual | AVG | NPEak | PPEak | STDDev | WFMCount | Selects which statistic result to return. |
Returns the corresponding statistic result for the output real power.
Returns the corresponding statistic result for the output real power. The query supports the current measurement result as well as statistic qualifiers such as average, negative peak, positive peak, standard deviation, and waveform count.
| Name | Type | Values | Description |
|---|---|---|---|
| qualifieropt | enum | ACTual | AVG | NPEak | PPEak | STDDev | WFMCount | Selects which statistic result to return. |
Returns the number of measured harmonics.
Returns the number of measured harmonics.
Selects the frequency of the input signal if POWer:HARMonics:STANdard is set to ENA/ENB/ENC/END.
| Name | Type | Values | Description |
|---|---|---|---|
| ENFrequency | enum | AUTO | F50 | F60 | Selects the frequency of the input signal. |
Starts the current harmonics measurement.
Returns the time duration of the measurement.
Returns the average frequency of the measured signal.
Returns the minimum frequency of the measured signal.
Returns the peak frequency measured during the power harmonics measurement.
Returns the standard deviation of the measured frequency in the harmonics measurement. The command is part of the POWER:HARMONICS:MEASurement:FREQuency result set.
Returns the present measured frequency of the harmonics measurement. The manual lists this as an actual-value query under the harmonics measurement subsystem.
Returns the actual measured real power in the harmonics measurement. This query is part of the power harmonics measurement results group.
Returns the average total harmonic distortion measurement for the power harmonics analysis. The command is part of the power harmonics measurement results group.
Returns the non-peak total harmonic distortion measurement value for the power harmonics measurement results. The command belongs to the power harmonics measurement result set.
Returns the present total harmonic distortion measurement value.
Returns the standard deviation of the total harmonic distortion measurement. The result is part of the POWER:HARMONICS:MEASurement:THDistortion measurement results.
Returns the total harmonic distortion measurement, or the actual total harmonic distortion when the optional ACTual node is used.
Adds a harmonics result to the report list.
Returns the frequency of harmonic result n.
Returns the limit level of the selected harmonic result. The result index <n> selects which harmonic result is queried.
Returns the level value of harmonic result n. The optional ':VALue' node is included in the query syntax.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Harmonic result index. |
Returns the maximum value of the specified harmonics result. This is a query on result index n.
Returns the mean value of the selected harmonics result.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Result index. |
Returns the minimum value of harmonic result <n>.
Returns whether the harmonic result is valid for the specified result index.
Returns the waveform count for the selected power harmonics result. The command is part of the result queries under :POWer:HARMonics:RESult<n>.
Executes the inrush current measurement function.
Starts a gate for the inrush current measurement on the specified gate number.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Gate number. |
Executes the power modulation analysis. The command is listed without any parameters or return value in this slice.
Returns the number of negative peaks in the low-peak result of the power modulation measurement.
Returns the peak-to-peak result of the lower peak group for modulation power measurements.
Returns the standard deviation of the low peak result for power modulation.
Returns the peak-to-peak value for the mean modulation result.
Returns the mean actual modulation power result.
Returns the number of peaks for the standard deviation result of the power modulation measurement.
Returns the peak-to-peak value of the standard deviation result for power modulation. This is a query in the POWer:MODulation:RESult:STDDev subtree.
Returns the waveform count for the standard deviation result of the power modulation measurement. This is a query command and yields the number of waveforms used in the result calculation.
Returns the actual standard deviation result of a power modulation measurement. The optional :ACTual node is part of the query syntax.
Returns the peak-to-peak value of the upper peak result in the power modulation measurement.
Returns the present upper-peak result value for power modulation; the optional actual form is documented as `[:ACTual]`.
Sets the lower threshold used for power modulation measurements.
Sets the upper modulation threshold for power modulation measurements. The optional node name is shown as :UPPer.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | Upper threshold value. |
Measures power on/off for the selected channel or signal in the power quality subsystem.
Executes the power quality measurement. No parameters or return value are documented in the provided slice.
Adds the selected power quality measurement report to the report list.
Returns the average crest factor for the current measurement result.
Returns the negative peak value for the current crest factor measurement.
Returns the standard deviation of the current crest factor result in the power quality measurements.
Returns the waveform count for the present current crest factor result in the power quality measurement group.
Returns the present actual crest factor result for the current power quality measurement. The optional node `:ACTual` is shown in the syntax list.
Returns the average frequency measurement result for the current power quality measurement.
Returns the negative peak value of the current frequency result. The command is part of the power quality current-frequency result set.
Returns the positive peak value of the current frequency result. This is a query in the power quality results group.
Returns the standard deviation of the current frequency measurement result.
Returns the current waveform count for the frequency power-quality result. The command is listed as a query under POWER:QUALity:RESult:CURRent:FREQuency.
Returns the present current frequency result, optionally the actual value. This command is part of the power quality results tree.
Returns the average RMS current result from the current power quality measurement.
Returns the negative peak value of the current RMS power-quality result.
Returns the standard deviation of the current RMS power-quality result.
Returns the waveform count for the present current RMS power-quality result. This command is documented in the list of power quality result queries.
Returns the present actual or current RMS power-quality result. The command is a query for the current measurement result in the POWer:QUALity:RESult:CURRent subsystem.
Returns the average apparent power result.
Returns the negative peak value of apparent power in the power quality result group.
Returns the positive peak of the apparent power result. This is a query command in the power quality results group.
Returns the standard deviation of the apparent power quality result. This is a query in the POWer:QUALity:RESult:POWer:APParent result group.
Returns the waveform count for the apparent power result. This is a query under the power quality results tree.
Returns the present apparent power actual result for the power quality measurement. The optional [:ACTual] node is part of the query mnemonic.
Returns the average power factor result from the power quality measurement. No parameters are documented for this query.
Returns the negative peak value of the power factor result in the power quality measurement. This is one of the statistical result queries under :POWer:QUALity:RESult:POWer:PFACtor.
Returns the positive peak value of the power factor result in the power quality measurement group.
Returns the standard deviation of the power factor result. This is a query in the POWer:QUALity:RESult:POWer:PFACtor result group.
Returns the waveform count for the power-factor result of the power quality measurement. This command is a query and is listed as part of the power quality result set.
Returns the actual power factor result from the power quality measurement results. The optional `ACTual` node is shown in brackets in the syntax.
Returns the average phase result for the power quality measurement.
Returns the negative peak value of the power phase result in the power quality measurement. The slice only lists the command in the index and does not provide further details on formatting or units.
Returns the positive peak value for the power phase result. This is a query under the power quality results tree.
Returns the standard deviation of the power phase measurement result. This is a query in the power quality results tree.
Returns the waveform count for the power phase result. This is a query under the power quality results tree.
Returns the present power phase result, or the actual power phase result when the optional node is used. This is part of the power quality results group.
Returns the average reactive power measurement result.
Returns the negative peak value for the active power result. This command is part of the power quality results group.
Returns the positive peak value of the reactive power result in the power quality measurement group.
Returns the standard deviation of the reactive power result in the power quality measurement group.
Returns the waveform count for the reactive power measurement result. This command is part of the power quality results tree.
Returns the present reactive power result for the selected power quality measurement. The optional ACTual node is part of the query syntax.
Returns the negative peak value of the real power result. This command is listed under the power quality results for real power.
Returns the positive peak value of the real power result. The command belongs to the POWER:QUALITY:RESULT:POWER:REALpower measurement result set.
Returns the actual real power result in the power quality measurement group. The page slice shows this command as part of the POWER:QUALITY:RESULT:POWER:REALpower result family.
Returns the average crest factor for voltage in the power quality result set.
Returns the number of peaks found for the voltage crest factor result. This is a power quality result query.
Returns the positive peak-to-peak value of the voltage crest factor result. This is a query command in the power quality results subtree.
Returns the standard deviation of the voltage crest factor power quality result.
Returns the waveform count for the voltage crest factor result. This is a query command with no parameters.
Returns the actual crest factor voltage result. The optional [:ACTual] node is part of the query mnemonic as listed in the command index.
Returns the average frequency result for voltage power-quality measurements.
Returns the negative peak value of the voltage frequency result in the power quality measurement. The slice provides only the command listing and does not document the returned data format.
Returns the peak-to-peak value of the voltage frequency result. The command is a query in the Power Quality results branch.
Returns the standard deviation of the voltage frequency result. This is a measurement result query in the Power Quality results subsystem.
Returns the number of waveforms used for the voltage frequency result. This is a result query in the Power Quality measurement group.
Returns the actual power-quality result value for voltage frequency. The optional [:ACTual] node is documented as part of the query mnemonic.
Returns the average RMS voltage result for the power quality measurement.
Returns the number of peaks used for the voltage RMS result calculation. This is a query command in the Power Quality results subsystem.
Returns the peak-to-peak value of the voltage RMS result. This command is part of the power quality results tree.
Returns the standard deviation of the voltage RMS result. This is a query command.
Returns the number of waveforms used to calculate the RMS voltage result. This is a read-only result query in the power quality results subsystem.
Returns the RMS voltage result for power quality measurements. The optional [:ACTual] form is listed in the command index.
Starts execution of the power ripple measurement. The command is listed under the power ripple subsystem in the command index.
Adds a report entry for the power ripple measurement.
Returns the average ripple frequency result for the selected power ripple measurement. This is a query command.
Returns the peak ripple frequency result for the power ripple measurement. The command is listed as a query only; no additional return-format details are given in this slice.
Returns the present peak ripple frequency result. The result is one of the ripple measurement result values listed for the Power Ripple subsystem.
Returns the waveform count for the ripple frequency result. The command belongs to the power ripple results section.
Returns the ripple result frequency for the current measurement. The optional :ACTual suffix is part of the query mnemonic as listed in the command index.
Returns the average of the low-peak result for the power ripple measurement.
Returns the N peak value of the ripple result low peak measurement.
Returns the peak-to-peak value of the low-peak result for the power ripple measurement. The list of commands shows it as a query under POWer:RIPPle:RESult:LPEak.
Returns the standard deviation of the low-peak ripple result. This is a query command.
Returns the waveform count for the LPeak result of the power ripple measurement.
Returns the present lower-peak result for the power ripple measurement. The optional `:ACTual` node selects the actual value form.
Returns the mean result of the power ripple measurement. The list of commands shows this as a query under POWer:RIPPle:RESult:MEAN.
Returns the mean peak-to-peak value for the ripple result measurement. This command is a query and yields the current measured result.
Returns the standard deviation of the mean result for the power ripple measurement.
Returns the number of waveforms used to calculate the mean power ripple result. This command is a query only.
Returns the mean result value for the power ripple measurement, or the actual mean value when the optional ACTual node is used. This command is a query only.
Returns the number of positive peaks for the ripple result. The command is part of the POWER:RIPPLE result measurements.
Returns the standard deviation of the NDCycle result for the ripple measurement. The command is listed under POWer:RIPPle results.
Returns the average duty cycle result for the power ripple measurement.
Returns the number of peak values used for the ripple power result calculation. This is a query command and yields the NPEak result for the selected ripple result path.
Returns the peak-to-peak value of the ripple result. This command is a query and yields the measured PPEak result for the ripple analysis.
Returns the waveform count for the ripple peak result. This is a query command.
Returns the N-peak result of the power ripple period measurement. The command is listed in the command index under POWer:RIPPle:RESult:PERiod:NPEak?.
Returns the positive peak result of the power ripple period measurement.
Returns the standard deviation of the power ripple period result.
Returns the number of waveforms used for the period result calculation.
Returns the power ripple result period value. The optional :ACTual node is documented as part of the query syntax.
Returns the standard deviation of the number of peaks result in the power ripple measurement.
Returns the standard deviation result for power ripple analysis. This is a query under the POWer:RIPPle:RESult:STDDev branch.
Returns the standard deviation result for the power ripple measurement. The optional ":ACTual" node is part of the command syntax.
Returns the average value of the power ripple result peak output. This is a query command with no parameters documented in the provided slice.
Returns the present positive peak result for the power ripple measurement.
Returns the standard deviation of the upper peak power-ripple result.
Returns the number of waveforms used for the current power-ripple result calculation.
Returns the actual upper peak power-ripple result. The optional :ACTual node may be included in the query syntax.
No documentation for this exact command appears in the provided page slice; the slice only shows nearby POWer:RIPPle:RESult commands in the list of commands.
Returns the present result peak-to-peak value for the slew-rate measurement. The command is a query under the POWer:SLEWrate:RESult:LPEak subtree.
Returns the waveform count for the slew-rate result peak measurement. The slice provides only the command listing and does not document the returned value in detail.
Returns the actual peak result for the power slew rate measurement. The optional ":ACTual" node is included in the query form shown in the index.
No command details are documented on this index page beyond the command listing. The entry appears only as a cross-reference in the list of commands.
Returns the number of points in the linear SOA list.
Returns the number of logarithmic SOA points. This is a query command.
Adds a report entry for the SOA function.
Returns whether the acquisition result for failures is present. This is a query in the SOA result acquisition group.
Returns the acquisition rate of the SOA result acquisition.
Returns whether the acquisition passed. The command is part of the result acquisition subsystem.
Returns the number of points in the acquisition result. The command is a query and reports the acquisition points count for the SOA result set.
Returns the acquisition state of the SOA result. The command is a query and yields the present state value.
Returns the number of acquired SOA result values. This is a query command.
Returns the current value for the specified SOA acquisition violation. The violation is selected by the <n> index in the command path.
Returns information about a specific acquisition violation in the SOA result set. The index <n> selects which violation record is queried.
Returns the total count of results in the SOA result set.
Returns the total number of failed results in the power SOA result summary.
Returns the total fraction rate of the SOA result summary.
Returns whether all total SOA results passed. This is a query command for the total result summary.
Returns the total sample count for the SOA result. The command is a query and yields the count value for the total sample set.
Returns the number of failed samples in the total SOA results. The command is part of the total results summary under :POWer:SOA:RESult:TOTal:SAMPle.
Returns whether the total sample pass count is available for the SOA result. This is a query command.
Returns the total SOA result state. The command is part of the POWer:SOA:RESult:TOTal subsystem.
Returns the total number of violations found in the SOA result. This is a query command under the POWer:SOA:RESult:TOTal subtree.
Returns the header of the current-data array for the specified total violation record. The command is a query and provides metadata for the data block format.
Returns the X increment of the current data for the specified total violation record. This is a query on the SOA result data for violation <n>.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Violation record number. |
Returns the X-origin of the current data for a total SOA violation record. The command addresses violation record <n> under the total results tree.
Returns the Y increment value for the current data of the specified total violation trace. This is a query for the current violation data block metadata.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Violation trace number. |
Returns the Y origin of the current data for the specified total violation. The index <n> selects which violation trace is queried.
Returns the Y-axis resolution of the current data for a total SOA violation record. The <n> index selects the violation record to query.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Violation record number. |
Returns the current data for total SOA violations of entry <n>. The data is returned in array form.
Returns the current value violation for the specified total SOA violation entry. The entry is addressed by `<n>`.
Returns the header information for the voltage data of the specified total violation record.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Violation record number. |
Returns the X increment of the voltage data for the specified total violation record. This is a query command in the SOA results hierarchy.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Violation record index. |
Returns the x-origin of the voltage data for the specified total violation record. The data format is part of the voltage data block for a power SOA result.
Returns the Y origin of the voltage data for the specified total violation record. The command belongs to the SOA result total violation voltage data query family.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Violation record number. |
Returns the Y-resolution of the voltage data for the specified total violation trace. The trace is addressed by <n>.
Returns the voltage data for the selected total SOA violation entry. The data is provided as an array of values for the specified violation number.
Returns the voltage of the specified total violation entry.
Returns the total number of violations for the selected SOA result entry <n>.
Sets the scale used for power SOA display or processing. The slice only lists the command name in the index and does not provide syntax or parameter details.
Executes the power spectrum analysis. The command starts the measurement using the currently configured spectrum settings.
Adds the current spectrum report to the report list.
Returns the frequency result of the selected power spectrum measurement result <n>.
Returns the level of the selected power spectrum result. The optional ":VALue" node is equivalent to the base command.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 - n | Result index. |
Returns the maximum value of the selected power spectrum result number.
Returns the mean value of the selected power spectrum result. The result index <n> identifies which spectrum result set is queried.
Returns the minimum value of the selected power spectrum result item.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Result index. |
Resets the stored result entry for the specified power spectrum result number.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Result index to reset. |
Returns the number of waveform counts for the specified power spectrum result entry.
| Name | Type | Values | Description |
|---|---|---|---|
| nopt | integer | - | Result index. |
Executes the switching power analysis.
Starts the negative conduction gate position for power switching measurements.
Sets the stop point for the negative conduction gate in power switching analysis.
Starts the TOFF gate interval for power switching analysis.
Adds the switching report to the currently active report list.
Returns the conduction energy result of a switching power measurement.
Returns the conduction power result of a switching analysis.
Returns the non-conduction energy result from the most recent switching analysis.
Returns the power result for the nonconduction interval of a switching measurement.
Returns the turn-off energy result of the switching analysis.
Returns the calculated output power in the TOFF interval.
Returns the measured energy for the TON interval in the power switching analysis.
Returns the power result for the ton interval in the switching analysis.
Returns the total switching energy result.
Returns the total switching power result.
Executes the transient power analysis. The command is listed as part of the POWER:TRANsient subsystem.
Adds the transient power measurement report to the report section. It is part of the POWer:TRANsient measurement command set.
Returns the transient delay result.
Returns the overshoot result of a power transient measurement.
Returns the time of the peak in the transient response result.
Returns the peak value measured during the transient response analysis.
Returns the rise time of the transient response.
Returns the settling time of the power transient result.
Sets the low signal level used for the power transient measurement. This command is part of the power transient measurement setup.
Starts the power transient analysis. The corresponding result items are available under POWer:TRANsient:RESult.
Stops the power transient measurement. The command is part of the power transient measurement command group.
Returns the maximum current state of the selected digital channel. This is part of the logic channel activity display commands.
Returns the minimum current state of the specified digital channel.
Returns whether the selected digital probe is enabled.
Aligns the skew between the probe boxes of the digital channels and the probe connectors of the analog channels. This sets all deskew values to zero.
Defines the size of the hysteresis to avoid changes of signal states due to noise.
Selects the digital threshold technology. Three predefined threshold levels and a user-defined threshold are available.
| Name | Type | Values | Description |
|---|---|---|---|
| technology | enum | TTL | CMOS | ECL | Threshold | Threshold technology or user-defined threshold selection. |
Sets all threshold and hysteresis values to the values of the first nibble (D0...D3).
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | on | Turns couple levels on. |
Sets the digital channel threshold level value between -2 V and +8 V in steps of 10 mV, or shows the value of the selected technology.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -2 - +8 | Threshold level value. |
Selects or edits a label for the specified logic channel. The maximum name length is 8 characters, and only ASCII characters provided on the on-screen keypad can be used.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Logic channel number. |
DIGital<m>:LABel DIGital<m>:LABel:STATe
Sets the state of a predefined label for a digital channel.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | State of the predefined label. |
Displays or hides the history player on the screen.
| Name | Type | Values | Description |
|---|---|---|---|
| PlayerControl | enum | ON | OFF | Shows or hides the history player. |
Returns the state of the header display for the specified digital channel. The command is a query and does not take any parameters.
Sets the number of points used for digital waveform data. The command is listed as a setter in the command index.
Returns the X increment for the specified digital channel. The command is a query and yields the horizontal increment used for digital data.
| Name | Type | Values | Description |
|---|---|---|---|
| mopt | integer | 1 - 16 | Digital channel number. |
Returns the X-axis origin for the selected digital channel waveform data.
Returns the Y increment for the specified digital channel. This is a query form of the digital data scaling command.
Returns the Y-origin of the digital waveform data for the specified channel m.
Returns the vertical resolution of the digital channel data.
Returns the binary waveform data for digital channel m. The data format is described together with the associated header and increment/origin commands.
Controls whether the specified digital channel is displayed. This command is listed as a setter with no documented parameters on the index page.
Returns the current digital channel history state. This command is the current-value form of the digital history subsystem.
Sets the filename used for the digital history export. The command belongs to the digital history export subsystem.
Saves the history export data for the selected digital channel. The command is listed under the Digital History Export subsystem.
Sets the player speed for digital history playback.
Selects the state of the history player for the specified digital channel. The manual slice lists the command in the command index but does not provide syntax or behavior details on this page.
Starts history acquisition for the specified digital channel. The command is available for a digital channel index <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Digital channel index. |
Stops the digital-history acquisition for the specified digital channel. The command belongs to the DIGital<m>:HISTory subsystem.
Returns the absolute timestamp history for the selected digital channel. The command also has an :ALL? form documented on the same page list.
Returns the date of the acquisition timestamp information for all digital channels in the history buffer.
Returns the date timestamp for the specified digital channel history entry. The command is a query for digital history date information.
Returns the relative timestamp information for all history entries on digital channel <m>.
Returns the relative time stamp information for a digital channel history entry.
Enables or disables the digital history table for the selected digital channel. The optional `ENABle` node indicates the enable setting can be addressed explicitly.
Sets the size of the selected digital channel group. The command is used with the channel index placeholder <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Digital channel group index. |
Returns the maximum current state of the specified logic channel. The command is listed among remote commands for logic channel activity display.
Returns the minimum current state of the specified logic channel.
Enables or queries the probe state of logic channel <p>.
Switches the selected logic pod on or off. You can also set the state of each logic channel separately in the short menu.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | on | off | Turns the selected logic pod on or off. |
Displays or hides the history player on the screen.
| Name | Type | Values | Description |
|---|---|---|---|
| PlayerControl | enum | ON | OFF |
Returns the header information for the selected logic data trace. This is a query command and does not take parameters.
Sets the number of points in the logic trace data. The command belongs to the LOGic<p>:DATA subsystem.
Returns the X increment for logic data. This is a query for the logic waveform data scaling.
Returns the Y increment for the logic waveform data of the selected probe channel. It is part of the LOGic<p>:DATA query family used to scale logic data values.
Returns the Y-origin of the logic data. This is a query command for logic channel <p> data scaling information.
Returns the vertical resolution of logic data. The command is a query for channel p.
Returns the logic analyzer data of the selected logic probe. The format and interpretation of the returned data are documented on the referenced data page.
Sets the current logic history record selection for channel <p>.
Sets the export file name used by the logic history export function.
Saves the current logic history export using the configured export name. The command belongs to the logic history export subsystem.
Controls all items in the logic history display. This is a setter command.
Sets the history player speed for the logic channel. The command belongs to the LOGic<p>:HISTory:PLAYer subsystem.
Sets or queries the logic history player state for channel <p>. The command is listed in the logic history player command group.
Starts history mode for the selected logic channel.
Stops the logic history playback or capture sequence.
Returns all absolute timestamps stored in the history table.
Returns the absolute timestamp values for the logic history. This query is part of the LOGic<p>:HISTory timestamp readout commands.
Returns the date timestamp information for all history entries of logic channel <p>.
Returns the date timestamp of the selected history entry.
Returns relative time stamps for all history entries in the logic channel.
Returns the relative time stamp values for logic history entries.
Enables or disables the history table for the specified logic channel. The command is part of the logic history subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| p | integer | - | Logic channel index. |
| stateopt | enum | ON | OFF | Enables or disables the history table. |
Sets the logic analyzer input type for the selected logic channel or port.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | - | Logic input type. |
Sets the number of logic-channel lines (bits) D0 to D15 analyzed in the clocked parallel bus. The maximum bus width is the number of logic input lines.
| Name | Type | Values | Description |
|---|---|---|---|
| width | integer | 1 - the number of logic input lines | Number of lines (bits) of the logic channels D0 to D15 to analyze. |
Sets the number of logic channels D0 to D15 to be analyzed in the parallel bus. The maximum number is the number of logic input lines.
For the parallel clocked bus, selects whether data is sampled on the rising edge, falling edge, or both edges of the clock. The clock slope marks the beginning of a new bit.
| Name | Type | Values | Description |
|---|---|---|---|
| slope | enum | RISing | FALLing | BOTH | Selects the clock edge used to sample data. |
Selects the input line for the clock signal of a clocked parallel bus. For a clocked parallel bus, this command is one of the last two lines that can be assigned to Clock and CS.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Input line used as the clock source. |
Enables the chip select line for the parallel clocked bus.
Selects whether the chip select signal for the parallel clocked bus is high active or low active.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | high | low | Chooses chip select active polarity, either high active (high = 1) or low active (low = 1). |
Selects the input line for the CS signal of a clocked parallel bus. For a clocked parallel bus, this command is used to choose the source for the "CS" line.
Selects the input line for each bit of the clocked parallel bus. For a clocked parallel bus, the last two lines can be used to select the source for the Clock and CS signals.
Selects the input line for each bit of the parallel bus. For a clocked parallel bus, the last two lines can be assigned to Clock and CS.
Displays or hides the history player on the screen.
| Name | Type | Values | Description |
|---|---|---|---|
| PlayerControl | enum | ON | OFF | Controls whether the history player is displayed. |
Sets the bus mode for the selected ARINC bus. The command is part of the BUS<b>:ARINc subsystem.
Sets the bus value for ARINC bus decoding.
| Name | Type | Values | Description |
|---|---|---|---|
| b | integer | - | Bus index placeholder. |
| c | integer | - | ARINC channel placeholder. |
| value | - | - | BRValue setting. |
Sets the data format for ARINC bus data. The command belongs to the BUS<b>:ARINc subtree.
Sets the high threshold for bus-b archive decoding. The command is part of the BUS<b>:ARINc threshold settings.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | High threshold value. |
Sets the low threshold for ARINC bus decoding on bus b.
Returns the number of words in the ARINC bus definition.
Returns the data value for the selected ARINC word, including the optional value suffix if present.
Returns the format of the selected ARINC word.
Returns the label value for a specified ARINC 429 word. The optional value suffix indicates the command can address the label's value form.
Returns the parity setting of the specified ARINC word.
Returns the pattern of the selected ARINC word.
Returns the SDI setting for the specified ARINC 429 word.
Returns the SSM setting for the specified ARINC 429 word. The command is a query for BUS<b>:ARINc:WORD<n> and does not document any additional parameters on this page.
Returns the start position of the selected ARINC word. This is a query on bus b, ARINC word n.
Returns the status of the selected ARINC word. The word is addressed by bus, ARINC instance, and word number.
Sets the CAN bus bit rate.
Returns the number of CAN frames. This is the query form of the BUS<b>:CAN subsystem counter command.
Returns the acknowledge value of the selected CAN frame. The command is a query for frame <n> within bus <b>.
Returns the beginning position of the bus CAN frame.
Returns the state of the selected CAN frame byte. The byte index is given by the `<o>` suffix in the mnemonic.
Returns the value of a specified byte in a CAN frame.
Returns the CAN frame checksum state for the selected bus frame. The command is a query and provides the current CS state.
Returns the CAN frame signal value. The command is a query for the CS value of CAN frame n.
Returns the CAN frame data field.
Returns the state of the CAN frame DLC setting for frame <n>.
Returns the CAN frame DLC value.
Returns the ID state of CAN frame <n>.
Returns the CAN frame identifier type for frame <n>.
Returns the value of the CAN frame identifier. The identifier format depends on the selected ID type.
Returns the start state of CAN frame acquisition for the specified bus and frame number.
Returns the status of the selected CAN frame.
Returns the stop state of the specified CAN frame. The command is part of the BUS CAN frame status queries.
Returns the CAN frame type for the selected frame. The command is a query on BUS<b>:CAN:FRAMe<n>.
Sets the CAN sample point for bus b.
| Name | Type | Values | Description |
|---|---|---|---|
| samplepoint | real | 0 - 100 | CAN sample point. |
Sets the CAN bus type.
Returns the field count for the selected parallel bus. This is a query command for bus <b>.
Returns the data of the selected parallel bus frame.
Starts the selected parallel bus frame. The manual lists this command in the command index only; no syntax, parameters, or return description are shown on the provided page slice.
Stops the parallel bus frame specified by the frame index. This is a query form of the command name shown in the list of commands.
Selects bus display signals for the bus decode display. This command is listed in the bus command index; the slice does not provide further syntax or parameter details.
Sets the bus data size for the selected bus. This command is listed in the bus command group; the page slice does not provide syntax details or a parameter description.
Selects the format used for bus decoding display. The command is listed as part of the BUS<b> subsystem.
Selects the current bus history entry. The command is listed in the bus history command set.
Sets the file name used for bus history export. The slice only lists the command in the command index and does not provide syntax details or parameter constraints.
Saves the history export data. The history export name is defined by :BUS<b>:HISTory:EXPort:NAME.
:BUS<b>:HISTory:EXPort:SAVE
Pall or pause all bus history playback/operations for the selected bus. The command belongs to the BUS<b>:HISTory subsystem.
Sets the speed of the history player.
| Name | Type | Values | Description |
|---|---|---|---|
| speed | real | - | History player speed. |
Sets the history player state.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the history player on or off. |
Replays history data.
Starts bus history capture for the selected bus.
Stops bus history recording or playback.
Returns all absolute timestamps from the bus history table for bus b.
Returns the absolute timestamp of the current bus history entry.
Returns all timestamp date entries in the bus history table. The command is part of the BUS history timestamp date functions.
Returns the date timestamp for the current history entry.
Returns all relative timestamps of the bus history entries. This is the query form of the history timestamp relative command.
Returns the relative time stamp of the current bus history entry.
Enables or disables the history time table for bus b. The optional `ENABle` node is part of the command mnemonic as listed in the command index.
Sets the I2C clock source used for bus decoding. The slice only lists the command in the command index and does not provide syntax, parameter details, or a return value.
Returns the total number of I2C frames currently detected for the selected bus.
Returns the access state of the selected I2C frame. The command applies to frame number <n> on bus <b>.
Returns the start address byte of the specified I2C frame.
Returns the AMODe setting for I2C frame <n>.
Queries the start state of the specified I2C frame. The frame number is given by <n> and bus index by <b>.
Returns the value of the specified byte within an I2C frame. The command is part of the I2C frame/byte inspection queries.
Returns the start status of the specified I2C frame. The frame is identified by the <n> index.
Returns the status of the selected I2C frame.
Sets the I2S variant used for bus decoding.
Sets the I2S bit order.
Sets the number of bits used for the selected I2S channel. This command is part of the I2S bus decode setup.
| Name | Type | Values | Description |
|---|---|---|---|
| length | integer | 1 - 32 | Number of bits used for the selected I2S channel. |
Sets the I2S channel order used for bus decoding. The command belongs to the BUS<b>:I2S:CHANnel group.
Sets the polarity used for I2S clock decoding. This command is part of the BUS<b>:I2S subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Clock polarity setting. |
Sets the source used for the I2S clock signal.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Clock source selection. |
Selects the I2S data source.
Sets whether the I2S bus is displayed.
Returns the count of I2S frames found in the selected bus decode.
Returns the start condition of the specified I2S frame.
Returns the state of the selected TDM slot in the specified I2S frame.
Returns the value assigned to the specified I2S TDM frame item.
Sets the I2S word length used for bus decoding.
Sets the polarity used for the I2S word select signal. This command belongs to the BUS<b>:I2S configuration group.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity setting for the word select signal. |
Sets the source of the I2S word select signal.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Source of the I2S word select signal. |
Sets the threshold used for the I2S word-select signal. The command belongs to the BUS<b>:I2S:WSELect subtree.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | Threshold level for the word-select signal. |
Sets or queries the label of the selected bus. The command belongs to the BUS subsystem.
Sets the bus label state for bus b.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | Label state for the selected bus. |
Returns the number of LIN frames found. This is a read-only query under the BUS<b>:LIN subsystem.
Returns the checksum state for the selected LIN frame. The frame number is specified by the <n> index in the command path.
Returns the ID parity value for the specified LIN frame.
Returns the stop frame number for the specified LIN frame. This is a query command for a LIN bus frame within bus b.
No command details are provided on this index page beyond its presence in the command list.
Sets the LIN bus polarity for bus <b>.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | LIN bus polarity setting. |
Selects the LIN standard used for bus decoding. The command is listed in the LIN bus command group, but this slice does not document its value set or syntax details.
Sets the maximum MIL-STD image time for bus b.
Sets the minimum MIL-STD image time for bus <b>.
Sets the MIL-STD bus source. It is part of the BUS<b>:MILStd subsystem.
Returns the word count for the selected MIL-STD bus decode branch.
Returns whether the broadcast command was received for the selected MIL-STD-1553 word. The result is reported as a status query for BUS<b>:MILStd:WORD<n>.
Returns the SREQ status for MIL-STD word <n>.
Returns the terminal status of the selected MIL-STD-1553 word. The command is part of the BUS<b>:MILStd:WORD<n>:STATus subsystem.
Returns the data of the selected parallel bus frame. The frame number is specified by <n>.
Returns the state of the selected parallel bus frame. The frame is addressed by bus number <b> and frame number <n>.
Sets the bus position. The command belongs to the BUS group.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Bus position. |
Sets the bus result display/source selection for bus b. The command is listed in the bus commands index for the RTM3000 manual.
Sets the SPI bus border selection.
Selects the source used for the SPI clock signal.
Sets the source used for SPI DATA in bus decoding. The command is part of the BUS SPI bus setup commands.
Returns the count of frames detected in the selected SPI bus signal. This is a query command.
Returns the MISO data of a selected SPI frame. The command is a query for the frame-specific SPI data value associated with MISO.
Returns the stop point of the selected SPI frame. This is a query for the bus/frame-specific stop position.
Returns the MOSI data of the specified word in the specified SPI frame. The command is part of the SPI bus decode word data queries.
Sets the source for the SPI MISO signal of bus b.
Sets the polarity of the MOSI signal used for SPI bus decoding.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity setting for the MOSI signal. |
Sets the bit time for the SSPI bus decode.
Sets the clock polarity for the selected SSPI bus. The command is part of the SSPI bus configuration commands.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Clock polarity setting. |
Sets the polarity of the SSPI data signal. The command belongs to the SSPI bus decode settings.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Data polarity setting. |
Sets the polarity of the MISO line for the selected SSPI bus. The command is part of the bus configuration commands.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | MISO polarity setting. |
Sets the polarity of the MOSI data line for the selected SSPI bus. This command belongs to the BUS<b>:SSPI subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity of the MOSI data line. |
Sets the UART bit time for bus <b>.
| Name | Type | Values | Description |
|---|---|---|---|
| bit time | real | s | UART bit time for bus <b>. |
Sets the source used for UART data. The slice lists this command in the UART command overview but does not provide the syntax details or allowed values.
Returns the field count for the selected UART bus decode.
Returns the start position of the specified UART frame. The frame is identified by the bus index and frame number.
Returns the state of the selected UART frame. The command queries frame <n> state within bus <b>.
Returns the stop position of UART frame <n>.
Returns the word count for the specified frame in the UART bus decode. The frame is selected by the frame number <n>.
| Name | Type | Values | Description |
|---|---|---|---|
| frame | integer | 1 | Frame number <n>. |
Returns the received value of a word within a UART frame. The frame and word are identified by the frame index <n> and word index <o>.
Returns the source setting for the specified UART frame word. The command is listed as a query only in the command index.
Returns the state of a selected UART frame word. The word is addressed by bus <b>, frame <n>, and word <o>.
Returns the stop position of a UART frame word. The frame and word indices are specified by <n> and <o>.
Returns the TX value of a specified UART word. This is a query command for the selected bus, frame, and word.
Returns the value of a UART frame word. The command is part of the BUS UART frame/word access subtree.
Sets the UART parity setting for bus b.
| Name | Type | Values | Description |
|---|---|---|---|
| parity | enum | - |
Sets the UART polarity for bus b.
Returns the number of received UART data items. This is a query for the received-data count on bus b.
Returns the start position of the specified UART receive frame. The frame is addressed by the frame index <n> under BUS<b>:UART:RX:FRAMe<n>.
Returns the state of the specified UART receive frame. The command is listed under BUS<b>:UART:RX:FRAMe<n>.
Returns the stop position of a received UART frame. The frame is selected by <n> and the bus by <b>.
Returns the word count for the specified UART frame. The frame is selected by the frame index <n> and the command is used on the BUS<b>:UART:RX path.
Returns the start position of a UART receive frame word. The command is listed as a query only; no additional return-format details are given in this slice.
Returns the state of the selected UART frame word in the receive path.
Returns the stop state of the selected UART receive frame word. The command applies to frame <n> and word <o>.
Returns the value of the specified UART frame word. The command is a query for a word within a received UART frame.
Selects the source of the UART receive signal for bus interpretations. The command is listed in the UART bus command index and is documented on the referenced command page.
Sets the UART stop-bit setting for the selected bus. The command is part of the BUS<UART> configuration group.
| Name | Type | Values | Description |
|---|---|---|---|
| b | integer | - | Bus index. |
Sets the UART stop-bit size used for bus decoding. The command applies to BUS b UART decoding.
| Name | Type | Values | Description |
|---|---|---|---|
| ssize | enum | - |
Returns the number of FIFO entries for the selected UART bus. This is a query command.
Returns the start condition of UART frame n. The command is a query for the starting point of the selected frame.
Returns the state of the specified UART frame. The frame is identified by the frame index n on bus b.
Returns the stop position of the specified UART frame. The frame is addressed by <n> under bus <b>.
Returns the word count for a specified UART frame. The command applies to BUS<b>:UART:FRAMe<n>.
Returns the start state of the specified TX frame word in a UART bus decode.
Returns the state of a UART transmit frame word. The command is a query for the word state within frame <n>, word <o> under BUS <b>.
Returns the stop state of the specified UART TX frame word. The frame number and word index are selected by the `<n>` and `<o>` nodes.
Returns the contents of the specified file from the current mass memory directory. The example shows reading back "GRAY.PNG" with a file name argument.
| Name | Type | Values | Description |
|---|---|---|---|
| filename | string | - | Name of the file to be read. |
MMEM:DATA? "GRAY.PNG"
Sets the data format used for waveform transfer. The example shows it being set to REAL before reading channel data.
| Name | Type | Values | Description |
|---|---|---|---|
| format | enum | REAL | UINT | Selects the waveform data format. |
FORM REAL
Sets the data format used for channel data transfer. The example shows UINT,8 and UINT,16 formats affecting the number of bytes per sample.
| Name | Type | Values | Description |
|---|---|---|---|
| format | enum | UINT | Data format to use for transfer. |
| width | integer | 8 - 16 | Bit width of the unsigned integer data format. |
FORM UINT,8;FORM? FORM UINT,16;FORM?
Starts the firmware update using a firmware update file previously stored in internal memory. The instrument loads, checks, executes the update, and restarts.
| Name | Type | Values | Description |
|---|---|---|---|
| file | string | - | Firmware update file path in internal storage. |
:DIAG:UPD:LOAD "/INT/RTM3004.FWU"\n
Closes the firmware update transfer. Use it after sending the update file data and before starting the firmware update.
:DIAG:UPD:TRAN:CLOSE\n
Outputs the function generator waveform output. In the example, it turns on the generated sine waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 1 | 0 | Enables or disables the waveform output. |
WGEN:OUTP 1 // Outputs the sine waveform
Displays or hides the history player on the screen.
| Name | Type | Values | Description |
|---|---|---|---|
| PlayerControlEnable | enum | ON | OFF | Controls whether the history player is displayed on the screen. |
Returns the header associated with the selected math waveform data.
Returns the number of points in the math waveform data. The command is a query for a specific math channel <m>.
Returns the X increment of the math waveform data. This is the spacing between adjacent X values.
Returns the X origin of the math data. This is a query for a math channel <m>.
Returns the Y increment for math trace data.
Returns the Y origin value for the selected math channel data. The command is a query and yields the origin of the Y axis data set.
Returns the Y-resolution of the selected math trace data.
Returns the math waveform data for the selected math channel. The command is a query for the current data record.
Sets the current history state for the selected math channel.
Clears the history display for the selected math channel.
Controls the state of the History Player for the selected math channel.
Replays the history data of math channel <m>.
Stops history recording for the selected math channel.
Returns the absolute timestamps for all history records of the selected math channel. The command is a query variant of the history timestamp absolute function.
Returns the absolute timestamp of the current history frame for the selected math channel.
Returns the relative timestamp values for all history records of the selected math channel. This is a query for the History TSRelative data set.
Turns the label for math trace m on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the label. |
Sets the horizontal position of math trace m.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Horizontal position of the math trace. |
Sets the scale of the selected math channel. The command is available for math channels MATH<m>.
Turns the selected math channel on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the selected math channel. |
Enables or disables the pulse tracking function for the selected math channel. This command belongs to the math track DPULSE settings.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | ENABled | DISabled | Turns pulse tracking on or off. |
Controls edge tracking for the selected math channel.
Sets the lower threshold used by track threshold measurements for math traces.
Defines which signals are generated at the [Aux Out] connector.
| Name | Type | Values | Description |
|---|---|---|---|
| OutputMode | enum | OFF | TRIGger | REFerence | MASK | Selects the signal or event source for the Aux Out connector. |
Defines the comparison operator used for the decoded ARINC 429 data condition against the specified data.
| Name | Type | Values | Description |
|---|---|---|---|
| Compare | enum | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin | OUTSide | Comparison operator for the decoded data condition. |
Specifies the maximum value of the data when TRIGger:A:ARINc:DATA:CONDition is set to INRange or OORange.
| Name | Type | Values | Description |
|---|---|---|---|
| DataMaximum | string | - | Maximum data value used for INRange or OORange conditions. |
Sets the minimum condition for the data. This value is used with the data condition and, for equal/not equal/greater than/less than conditions, one data word must be set with this command.
| Name | Type | Values | Description |
|---|---|---|---|
| DataMinimum | string | - | Minimum data condition value. |
Sets a data offset.
| Name | Type | Values | Description |
|---|---|---|---|
| DataOffset | - | - |
Sets the data size for serial bus analysis trigger arming. The slice provides no additional range or format information for this parameter.
| Name | Type | Values | Description |
|---|---|---|---|
| DataSize | - | - | Data size. |
Enables triggering when a coding error occurs.
| Name | Type | Values | Description |
|---|---|---|---|
| ErrorEnable | enum | ON | OFF | Enables or disables triggering when a coding error occurs. |
Enables triggering when a gap error occurs.
| Name | Type | Values | Description |
|---|---|---|---|
| ErrorEnable | enum | ON | OFF | Enables or disables triggering on gap error. |
Enables triggering when a parity error occurs.
| Name | Type | Values | Description |
|---|---|---|---|
| ErrorEnable | enum | ON | OFF | Enables or disables triggering on parity errors. |
Sets the transmission format to be triggered on.
| Name | Type | Values | Description |
|---|---|---|---|
| DataFormat | enum | DATA | DSSM | DSDI | DSSSm | Transmission format to trigger on. |
Defines the comparison operator used for the decoded label condition in serial bus trigger arming. The allowed operators include equality, inequality, greater/less than, within, outside, and in-range/out-of-range comparisons.
| Name | Type | Values | Description |
|---|---|---|---|
| compare | enum | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin | OUTSide | Operator used to compare the decoded label condition with the specified label. |
Specifies the maximum value of the label if TRIGger:A:ARINc:LABel:CONDition is set to INRange or OORange.
| Name | Type | Values | Description |
|---|---|---|---|
| labelmaximum | string | - | Maximum label value. |
Sets the minimum value of the label to be triggered on.
| Name | Type | Values | Description |
|---|---|---|---|
| LabelMinimum | string | - | Minimum label value to trigger on. |
Sets the source/destination identifier (SDI) bits to be triggered on.
| Name | Type | Values | Description |
|---|---|---|---|
| SDIvalue | enum | ANY | S00 | S01 | S10 | S11 |
Sets the sign/status matrix (SSM) bits to be triggered on.
| Name | Type | Values | Description |
|---|---|---|---|
| SSMvalue | enum | ANY | S00 | S01 | S10 | S11 | Sign/status matrix bits to be triggered on. |
Defines the comparison operator for the decoded transmission time condition against the specified data.
| Name | Type | Values | Description |
|---|---|---|---|
| Compare | enum | GTHan | LTHan | WITHin | OUTSide | Comparison operator used for the decoded transmission time condition. |
Sets the maximum value of the transmission time.
| Name | Type | Values | Description |
|---|---|---|---|
| TransmissionTimeMax | - | - |
Sets the minimum value of the transmission time.
| Name | Type | Values | Description |
|---|---|---|---|
| TransmissionTimeMin | - | - | Minimum value of the transmission time. |
Selects the type of trigger for ARINC 429 analysis.
| Name | Type | Values | Description |
|---|---|---|---|
| TriggerType | enum | WORD | ERRor | LABel | LDATa | TTIMe | Trigger type to use. |
Sets the word type to be triggered on.
| Name | Type | Values | Description |
|---|---|---|---|
| WordType | enum | STARt | STOP | Word type to be triggered on. |
Sets the CAN CRC error trigger condition for trigger A.
Sets the CAN trigger form error condition. This command is part of the TRIGger:A:CAN trigger setup.
Sets the left-channel I2S trigger condition.
Sets the maximum data value for the left I2S channel trigger condition. This command belongs to the I2S trigger setup for the LEFT channel.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Maximum data value for the left I2S channel trigger condition. |
Sets the minimum data word condition for the left I2S channel trigger. This command is part of the I2S channel trigger configuration.
Sets the condition for the selected I2S TDM channel trigger. The command belongs to the I2S channel trigger group for TDM<n>.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | TDM channel number. |
Sets the I2S trigger function.
Sets the WS slope used for I2S trigger selection. The list of commands shows this as a subcommand under TRIGger:A:I2S.
Sets the lower rise-time trigger level for trigger A. The level number <n> selects which trigger level is configured.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Trigger level number to configure. |
Sets the LIN checksum error trigger condition.
Sets the LIN trigger data condition for trigger A.
Sets the LIN identifier used for the trigger condition.
| Name | Type | Values | Description |
|---|---|---|---|
| identifier | integer | - | LIN identifier value. |
Sets the LIN parity error trigger condition.
Sets the LIN system error trigger condition.
Sets the maximum data value used for the MIL-STD trigger data comparison. The command is listed under the MILStd trigger data settings alongside the corresponding minimum and offset commands.
Sets the minimum data value used for MIL-STD trigger conditions.
Sets the number of words used for MIL-STD data triggering.
| Name | Type | Values | Description |
|---|---|---|---|
| words | integer | 0 - 65535 | Number of words. |
Sets the MIL-STD trigger error synchronization condition.
Sets the minimum allowed value for the MIL-STD RT address trigger parameter. This command belongs to the MIL-STD trigger settings for trigger A.
Sets the condition for the serial address trigger in MIL-STD mode.
| Name | Type | Values | Description |
|---|---|---|---|
| condition | enum | - | Trigger condition for the serial address. |
Sets the maximum search address for MIL-STD trigger address conditions. This command belongs to the TRIGger:A:MILStd:SADDress group.
Sets the minimum start address for the MIL-STD trigger on trigger A.
| Name | Type | Values | Description |
|---|---|---|---|
| address | integer | - | Minimum start address used for MIL-STD trigger A. |
Sets the MIL-STD status trigger to the BCReceived condition. The command is part of the MIL-STD trigger status selection group.
Sets the MIL-STD trigger status condition to BUSY.
Selects the MIL-STD status condition for DBC acceptance.
Sets the status trigger source to Instrument. This command is part of the MIL-STD trigger status configuration.
No command documentation is shown on this page slice; only the table of contents lists the command.
Sets the status trigger source request condition for MIL-STD trigger A. This command is listed under the MIL-STD trigger status group.
Sets the MIL-STD status subsystem trigger condition. The command is listed as a subcommand under the MIL-STD trigger status group.
Sets the terminal for the MIL-STD status trigger condition.
| Name | Type | Values | Description |
|---|---|---|---|
| terminal | enum | - | Terminal selection for the status trigger condition. |
Sets the MIL-STD-1553 trigger mode for trigger A.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Trigger mode. |
Sets the maximum word count for MIL-STD trigger decoding. This command belongs to the MIL-STD trigger subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| minimum | - | - |
Sets the MIL-STD word trigger condition. The command belongs to the MIL-STD trigger settings group.
Sets the trigger mode for trigger A.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Trigger mode. |
Sets the pattern trigger condition. The command belongs to the A trigger source pattern trigger subsystem.
Sets the pattern trigger function for trigger A. The command is listed in the pattern trigger section of the manual.
Sets the trigger pattern mode for source A. The mode determines how the pattern trigger evaluates the selected input pattern.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Trigger pattern mode. |
Sets the source used for A-pattern triggering.
Sets the delta for the A pattern width trigger. The command is part of the A pattern width trigger settings.
| Name | Type | Values | Description |
|---|---|---|---|
| delta | real | MINimum - MAXimum | Delta value for the pattern width trigger. |
Sets the width condition for pattern trigger A. The command can also be used with the optional width sub-node variant shown in the syntax.
Sets the rise-time delta trigger setting for trigger A. The slice only shows the command in the command list and does not provide syntax details or parameter definitions.
Sets the trigger A rise-time range used for the rise-time trigger condition.
Sets the slope used for rise-time trigger evaluation. The command belongs to the Trigger A rise-time trigger subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| slope | enum | - |
Sets the trigger rise time value for trigger A. The command is part of the rise time trigger settings.
Sets the range used for RUNT trigger qualification on channel A. The command belongs to the trigger setup for runt pulse detection.
Sets the width trigger for trigger A in runt mode. The command is part of the trigger A runt trigger settings.
Sets the SPI trigger pattern condition for trigger A.
Sets the SPI pattern offset used by the trigger. The command belongs to the A trigger source SPI configuration.
Sets or queries the TV trigger field selection.
Sets the TV line trigger line number.
| Name | Type | Values | Description |
|---|---|---|---|
| line | integer | 1 - 625 | Line number used for TV line trigger. |
Sets the polarity for TV trigger A.
Sets the UART trigger pattern length. The command is listed in the trigger command tree under TRIGger:A:UART.
Sets the pulse offset for UART triggering. The command belongs to the UART trigger configuration group.
Sets the polarity for the width trigger. The command belongs to trigger A width settings.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity setting for width triggering. |
Sets the trigger B delay. The command is listed in the trigger command index with page reference 466.
Sets the edge slope used for trigger B. The manual index lists this command on the trigger B configuration page.
Controls whether trigger B is enabled. This command is listed in the command index for the trigger subsystem.
Sets the count for trigger B events. The command is listed in the command index, but this page slice does not provide the syntax or parameter details.
Sets the trigger B mode.
Sets the source for trigger B. The command is listed in the trigger B command group.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Trigger B source. |
Saves the event trigger settings for later recall. The command is listed in the command index with no parameter or return details on this page slice.
Saves the trigger event screen image. The destination for the saved screen can be set with the associated destination command.
Sets the destination for screen-save operations triggered by :TRIGger:EVENt:SCRSave. The command is referenced in the command list alongside :TRIGger:EVENt:SCRSave and related save commands.
Triggers an event-related sound. The command is listed as part of the trigger event commands, but this page slice does not provide its syntax or parameter details.
Triggers a trigger-out event action. The command is part of the trigger event subsystem.
Saves a waveform when the specified trigger event occurs.
Sets the destination for saving waveform files triggered by an event. The command is part of the TRIGger:EVENt:WFMSave function set.
| Name | Type | Values | Description |
|---|---|---|---|
| destination | - | - | Destination for waveform file saving. |
Enables or disables the trigger event function. This command is documented as the parameterized form of TRIGger:EVENt.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ENABle | DISAble | Turns the trigger event function on or off. |
Sets the trigger output pulse length. The command is part of the trigger output settings.
Sets the polarity of the trigger output signal.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity of the trigger output signal. |
Searches for a message error bit of a status word.
| Name | Type | Values | Description |
|---|---|---|---|
| StatusBit | enum | 0 | 1 | X |
Searches for a service request bit of a status word.
| Name | Type | Values | Description |
|---|---|---|---|
| StatusBit | enum | 0 | 1 | X | Status bit to search for. |
Searches for a subsystem bit of a status word.
| Name | Type | Values | Description |
|---|---|---|---|
| StatusBit | enum | 0 | 1 | X | Subsystem bit to search for. |
Searches for a terminal bit of a status word.
| Name | Type | Values | Description |
|---|---|---|---|
| StatusBit | enum | 0 | 1 | X |
Selects the transmission mode to be searched for.
| Name | Type | Values | Description |
|---|---|---|---|
| DataDirection | enum | TRANsmit | RECeive | EITHer | Transmission mode to be searched for. |
Selects the transmission type to be searched for.
| Name | Type | Values | Description |
|---|---|---|---|
| TransmissionType | enum | BCRT | RTBC | RTRT | MCData | Transmission type to search for. |
Searches for a comparison condition of the word count.
| Name | Type | Values | Description |
|---|---|---|---|
| Compare | enum | OFF | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin | OUTSide | Comparison condition used for the word count search. |
Searches for the maximum word count.
| Name | Type | Values | Description |
|---|---|---|---|
| WordCountMaximum | integer | - |
Searches for the minimum word count.
| Name | Type | Values | Description |
|---|---|---|---|
| WordCountMinimum | integer | - |
Selects a word start to be searched for.
| Name | Type | Values | Description |
|---|---|---|---|
| WordStart | enum | COMMand | STATus | DATA | Word start to be searched for. |
Sets the event or combination of events to be searched for. Depending on the selected event, further settings are required.
| Name | Type | Values | Description |
|---|---|---|---|
| SearchCondition | enum | WORD | ERRor | LABel | LDATa | Search condition to be searched for. |
Sets the comparison condition for data. It is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataCondition | enum | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin | OUTSide | Comparison condition for data. |
Searches for a maximum value of the data if the data condition is set to INRange or OORange. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataMaximum | string | - | Maximum data value pattern in 01X-string format. |
Searches for a minimum value of the data. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataMinimum | string | - | 01X-string to search for as the minimum data value. |
Searches for specified data offset. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataOffset | - | - |
Searches for specified data size. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataSize | - | - |
Searches for an error condition. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to ERRor.
| Name | Type | Values | Description |
|---|---|---|---|
| ErrorCondition | enum | ANY | PARity | GAP | CODing | Error condition to search for. |
Searches for a data format. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| DataFormat | enum | DATA | DSSM | DSDI | DSSSm | Data format to search for. |
Sets the comparison condition for a label. If the pattern contains at least one X (don't care), you can trigger on values equal or not equal to the specified value; if it contains only 0 and 1, you can also trigger on a range greater than or lower than the specified value.
| Name | Type | Values | Description |
|---|---|---|---|
| labelcondition | enum | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin | OUTSide | Comparison condition for label matching. |
Searches for a maximum value of the label if the label comparison condition is set to INRange or OORange. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LABel or LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| labelmaximum | string | - | 01X-string defining the maximum label pattern to search for. |
Searches for a minimum value of the label. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to LABel or LDATa.
| Name | Type | Values | Description |
|---|---|---|---|
| LabelMinimum | string | - | Minimum label value to search for. |
Searches for the specified source/destination identifier (SDI) bits. The command is relevant if `SEARch:PROTocol:ARINc:CONDition` is set to `LDATa`.
| Name | Type | Values | Description |
|---|---|---|---|
| SDIvalue | enum | ANY | S00 | S01 | S10 | S11 | Specifies the SDI bit pattern to search for. |
Searches for specified sign/status matrix (SSM) bits. The command is relevant if `SEARch:PROTocol:ARINc:CONDition` is set to `LDATa`.
| Name | Type | Values | Description |
|---|---|---|---|
| SSMvalue | enum | ANY | S00 | S01 | S10 | S11 | Sign/status matrix bits to search for. |
Selects the word type to be searched for. The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to WORD.
| Name | Type | Values | Description |
|---|---|---|---|
| WordType | enum | STARt | STOP | Word type to be searched for. |
Selects the peak magnitude search measurement. The slice only lists the command in the command index and does not provide syntax or behavioral details.
Selects polarity peak searching in the search measurement subsystem. The slice only shows the command listing and does not provide syntax or functional details.
Searches for CAN protocol ACK errors. This entry is listed in the command index; the slice does not provide syntax, parameters, or return details.
Searches for a CAN protocol identifier event. The command is listed in the CAN search command set.
Searches for a LIN frame by identifier within the protocol search function. The list of commands indicates this is the LIN identifier-related search command.
Returns the LIN protocol search error state.
Sets the MIL-STD data condition used for search protocol matching.
| Name | Type | Values | Description |
|---|---|---|---|
| condition | enum | - | Condition keyword for MIL-STD data search. |
Returns the maximum data value found by the search protocol MIL-Std data search.
Sets the minimum value of the MIL-STD data search range.
Checks the MIL-STD error condition search result. The command is listed under the MILStd search protocol commands.
Sets the MIL-STD word code used for search protocol functions.
Sets the condition for the MIL-STD RT address search.
Sets or queries the maximum RT address used for MIL-STD search protocol settings. The command is listed as part of the MILStd RTADdress group.
Sets the condition for the MIL-STD search S address. The command is part of the protocol search settings.
Sets the maximum allowed source address for MIL-STD search criteria. This is a limit command within the SEARch:PROTocol:MILStd:SADDress subtree.
Sets the main-channel address (MCAddress) used in the MIL-STD search protocol configuration. This command is part of the MILStd:SADDress node.
Sets the minimum search protocol MIL-STD address. This command is part of the MIL-STD protocol search settings.
Reports the status of received MIL-STD bus controller data found by the search function.
Returns whether the MIL-STD search status is busy.
Sets whether data bytes with a DBC accept status are accepted during MIL-STD search. The command is listed under the MILStd status commands; no parameter syntax or return value is documented on this page slice.
Returns the MIL-STD instrument status condition. The status is part of the protocol search status group.
Returns the count of search results currently available.
Turns the search result diagram display on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Selects whether the search result diagram is shown. |
Returns all search results. The command is listed as a query in the command index.
Returns the number of results found by the search function.
Returns the result of the specified search target. The <n> suffix selects which search result to read out.
Selects the source for search. The detailed parameter syntax is not shown on this page slice.
Sets the search state. The command is listed in the command index without further syntax or parameter details on this page.
Sets the trigger data-to-clock edge search condition. The command belongs to the search trigger configuration group.
Sets the search trigger data-to-clock low level. The command is listed in the Search Trigger Data-to-clock command group.
Defines the trigger data-to-clock source for search functionality.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Data-to-clock trigger source. |
Sets the trigger level used for the search trigger data-to-clock condition. The manual lists this command as part of the SEARch:TRIGger:DATatoclock group.
Sets the search trigger data-to-clock setup time. The command is part of the search trigger data-to-clock settings group.
| Name | Type | Values | Description |
|---|---|---|---|
| stime | real | s | Setup time for the data-to-clock search trigger. |
Sets the trigger level used for edge search. The command is part of the search trigger configuration.
Sets the lower threshold level for rise-time trigger level settings. The command is listed under the search trigger level commands.
Sets the upper trigger level for rise time search triggering.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | - | Upper trigger level used for rise time search triggering. |
Sets the lower runts trigger level. This command is part of the search trigger level settings for runt triggering.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | MINimum - MAXimum | Lower threshold level for runt triggering. |
Sets the upper runt trigger level. The command is part of the search trigger level settings for runt triggering.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | - | Upper runt trigger level. |
Sets the lower trigger level for search trigger window mode. The paired upper-level command is SEARch:TRIGger:LEVel:WINDow:UPPer.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | - | Lower trigger level. |
Sets the upper limit of the search trigger level window. This command is part of the search trigger window level settings.
Sets the function used for the pattern trigger search. The command is part of the SEARch:TRIGger:PATTern subsystem.
Sets the search trigger level for a specific input channel or source number n.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | 1 | Channel or source number for which the pattern trigger level is set. |
Sets the delta value for pattern search trigger level <n>.
| Name | Type | Values | Description |
|---|---|---|---|
| n | integer | - | Pattern trigger level index. |
| delta | real | - | Delta applied to the selected pattern trigger level. |
Sets the delta for pattern width search trigger settings.
| Name | Type | Values | Description |
|---|---|---|---|
| delta | real | - | Delta value for the pattern width trigger search. |
Sets or queries the width range used for pattern trigger searches.
Sets the pattern search trigger width. The optional second width node is part of the mnemonic syntax as printed.
Sets the rise time delta used for search trigger evaluation. The command is listed in the search trigger command index.
Sets the rise time trigger search range.
Sets the trigger slope used for rise-time search triggering.
Sets the search trigger risetime time parameter. The command is listed in the command index; no further syntax or functional details are provided on this page slice.
Sets the delta for the runt trigger search. The command belongs to the search trigger runt configuration.
Sets the polarity used for RUNT search triggering.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity selection for RUNT search triggering. |
Sets the search trigger runts range. The command belongs to the search trigger runt configuration group.
Sets the RUNT pulse width search trigger parameter. The command is part of the search trigger setup for runt conditions.
| Name | Type | Values | Description |
|---|---|---|---|
| width | real | 0 - MAXimum | Specifies the runt width. |
Sets the trigger level for search triggering by width. The slice only lists the command name in the index and does not provide syntax or parameter details.
Sets the delta for the width-level search trigger threshold. This command belongs to the search trigger width-level subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| delta | real | MINimum - MAXimum | Delta value for the width-level trigger threshold. |
Sets the width range used for the search trigger. The command is part of the search-trigger width settings.
Sets or queries the search trigger width. It is part of the search-trigger width setup and may be used with an optional inner width node in the command tree.
| Name | Type | Values | Description |
|---|---|---|---|
| width | real | - | Width value for the search trigger. |
Sets the trigger window delta value used for search trigger configuration.
| Name | Type | Values | Description |
|---|---|---|---|
| delta | real | - | Delta value for the trigger window. |
Sets the polarity used for window search triggering.
Sets the trigger window range used for search triggering. The command is listed under the SEARch:TRIGger:WINDow group; no parameter details are shown in this page slice.
Sets the timerange for window search triggering.
Sets the search trigger window width. This command is listed as an available command in the search trigger section, but the slice does not provide its syntax or parameter details.
Stops command processing until 1 is returned. The 1 is returned when all pending operations are completed.
SINGle; *OPC? INIT; *OPC?
Sets or reads the service request enable register (SRE). The register is linked to the status byte and can generate a service request when enabled bits in the STB change from 0 to 1.
Reads the event status enable register value. The ESE register corresponds to the ENABle part of a SCPI register.
Queries the higher-level instrument status register. The returned value is a decimal number representing the bit pattern of the queried register.
This command is listed in the command index, but the provided slice does not document its function, parameters, or return value.
Clears all event registers and the error queue.
Sets the service request enable register. The register masks events that can generate a service request.
| Name | Type | Values | Description |
|---|---|---|---|
| value | integer | 0 - 255 | Bit mask written to the service request enable register. |
Returns the Event Status Register. The register contains bits that reflect the occurrence of events in the instrument.
Returns the instrument identification string.
Sets the Operation Complete bit in the standard event status register when all preceding commands have been processed.
Returns the instrument options installed.
Sets or queries the power-on status clear flag. The command determines whether the status registers are cleared at power-on.
Resets the instrument to its default state.
Sets the service request enable register mask.
| Name | Type | Values | Description |
|---|---|---|---|
| mask | integer | 0 - 255 | Service request enable register bit mask. |
Returns the status byte value of the instrument.
Triggers the oscilloscope to start acquisition immediately.
Waits to continue execution until all pending operations are complete.
Contains information about channel overload in the questionable status register. The bit is set if the assigned channel is overloaded.
This register contains information about the instrument's temperature. It reports temperature warning and temperature error status bits for channels 1 through 4.
This register contains all information about overflow of the ADC. A bit is set if the assigned channel signal is clipped on the upper or lower edge of the screen, indicating ADC overflow.
This register contains information about the observance of the limits of measurements. The bit is set if the limits of the assigned measurement are violated.
This register contains information about the violation of masks. The bit is set if the assigned mask is violated.
Returns the current condition register of the Operation status group.
Sets the enable register for the Operation status group.
| Name | Type | Values | Description |
|---|---|---|---|
| enable register | integer | 0 - 65535 | Bit mask for enabling selected Operation status events. |
Sets the negative transition filter for the Operation status register. This command belongs to the STATus:OPERation status group and is used together with the corresponding condition, enable, and positive-transition commands.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Negative transition setting. |
Sets the positive transition filter for the Operation status register. It is part of the STATus:OPERation status event handling group.
| Name | Type | Values | Description |
|---|---|---|---|
| condition | integer | 0 - 65535 | Positive transition mask for the Operation status register. |
Returns the contents of the Operation Status Event register. The short form [:EVENt]? indicates the optional event subnode may be omitted.
Resets the status reporting registers to their preset state.
Returns the current condition of the ADC state questionable status register.
Sets the enable register for the questionable ADC state status tree. This command is part of the status subsystem under STATus:QUEStionable:ADCState.
| Name | Type | Values | Description |
|---|---|---|---|
| enable | integer | - | Enable register value. |
Sets the negative transition filter for the questionable ADC state event register. This command belongs to the STATus:QUEStionable:ADCState group.
Sets the positive transition filter for the Questionable ADC State status register. This command is part of the status subsystem for ADC state events.
Returns the event register bit pattern for the Questionable ADC state status group.
Returns the current condition register of the questionable status register set.
Returns the questionable overload condition register value.
Enables or disables the questionable overload status reporting. The command belongs to the STATus:QUEStionable:COVerload subtree.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns overload status reporting on or off. |
Sets the negative transition condition for the questionable overload status group. It is listed alongside the related condition, enable, positive transition, and event commands.
Sets the positive transition status enable for questionable overload events.
Returns the current questionable overload event status.
Enables or disables the Questionable status register summary bit. The setting affects whether questionable status events are reported in the status system.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the questionable status enable on or off. |
Returns the condition register for the questionable limit status group.
Enables or disables the questionable limit status reporting. This command is part of the STATus:QUEStionable subtree.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the questionable limit status reporting. |
Sets the negative transition value for the questionable limit status subsystem.
Sets the positive transition condition for the questionable limit status register.
Returns the current questionable status limit event register. The optional [:EVENt] node is part of the query mnemonic as listed in the command index.
Returns the questionable status mask condition register. This command reports the current condition of the MASK status subsystem.
Enables or disables the questionable status mask register.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | Turns the questionable status mask register off or on. |
Sets the transition mask for the questionable status subsystem. It is one of the status event handling commands alongside ENABle and PTRansition.
Sets the positive transition mask for the questionable status register. This command belongs to the STATus:QUEStionable:MASK subtree; the page slice does not provide further parameter details.
Returns the event register for the questionable status mask condition. The command is the query form of STATus:QUEStionable:MASK[:EVENt].
Sets the negative-transition event enable for the questionable status register tree. This command is part of the STATus:QUEStionable status subsystem.
Sets the positive-transition status reporting for the questionable status register. This command is listed alongside the other questionable-status transition and event commands.
Returns the questionable event status register contents. The optional [:EVENt] node is part of the query mnemonic as listed in the command index.
Indicates whether acquisition is available.
Indicates whether an averaging acquisition is complete.
Sets the number of acquisitions to be averaged. The command is part of the acquisition averaging subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 2 - 65536 | Number of acquisitions to average. |
Returns the current averaged acquisition value.
Resets the averaging acquisition settings.
Sets the number of acquisitions used for the current acquisition mode.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 - 65535 | Number of acquisitions to average or otherwise accumulate, depending on the selected acquisition mode. |
Sets the acquisition mode to high-resolution. This command is listed as a command entry in the acquisition subsystem.
Sets the acquisition interpolation mode.
Selects the acquisition memory mode. The command is listed as an optional node under ACQuire:MEMory.
Sets the number of acquisitions for single acquisition mode.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 - 65536 | Number of acquisitions to be performed in single acquisition mode. |
Sets the acquisition mode to peak detect. Peak detect is listed as one of the acquisition types in the command list.
Returns the acquisition point rate. This is a query command.
Sets the automatic acquisition points mode.
Sets the number of acquisition points. The value can also be set to the special keyword form documented for this command.
| Name | Type | Values | Description |
|---|---|---|---|
| value | integer | 1 - 10000000 | Number of acquisition points. |
| qualifieropt | enum | MINimum | MAXimum | DEFault | Special keyword form for setting the points value. |
Sets or queries whether segmented acquisition is enabled. The command appears in the acquisition command list; no further syntax or behavior is documented on this page slice.
Returns the acquisition sample rate.
Sets the acquisition state.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Acquisition state. |
Sets the acquisition type. The command is listed in the acquisition command overview.
Automatically adjusts the oscilloscope vertical and horizontal settings for a usable display.
Selects the mode for BPlot amplitude display. The command is listed under the BPLot:AMPLitude subsystem.
Sets the position of the amplitude display for the B plot.
Sets or queries the number of points in the amplitude profile. The command belongs to the BPLot:AMPLitude:PROFile subtree.
Sets the amplitude value of a profile point in a BPlot amplitude profile. The point is identified by the <n> index in the command mnemonic.
| Name | Type | Values | Description |
|---|---|---|---|
| amplitude | real | - | Amplitude value for the specified profile point. |
Sets the scale for the BPLot amplitude display.
| Name | Type | Values | Description |
|---|---|---|---|
| scale | real | - | Scale for the BPLot amplitude display. |
Sets the export file name for the B plot export function.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | Name of the export file. |
Sets the start frequency for the BPLot frequency display.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | - | Start frequency for the BPLot frequency display. |
Sets the stop frequency for the BPlot frequency display range.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | Hz | Stop frequency of the BPlot frequency range. |
Returns the data for the gain diagram trace. The command is listed in the BPLot command group alongside related gain display settings.
Enables or disables the BPLot gain display. The command is listed with the BPLot gain commands on the command index page.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ENABle | State to enable the gain display. |
Sets the position of the BPLot gain display. The command is listed in the command index without further syntax or range details on this page slice.
Sets the scale for the BPLot gain display. The command is listed in the BPLot gain command group, with no further syntax details shown on this page.
Selects the input source for the BPLot display.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Input source for the BPLot display. |
Returns the frequency difference for the selected marker in the BPLot view.
Returns the gain difference of the selected marker on a B plot.
Returns the phase difference marker value for the selected BPlot marker. The marker index is specified by <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Marker index. |
Sets the frequency marker for marker <m> in the BPLot display.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | - | Frequency of the marker. |
Returns the gain of marker <m> in the BPLot display.
Returns the phase of marker <m> in the B plot.
Screens the selected marker in the Bode plot. The marker index is given by <m>.
Sets the measurement delay for the BPlot function.
Sets whether the measurement point is displayed. The command is available as an optional ":DISPLAY" node.
| Name | Type | Values | Description |
|---|---|---|---|
| displayopt | enum | - | Controls display of the measurement point. |
Selects the source used for the BPLot output. The command is listed as an optional source node.
Returns the phase data for the B plot.
Returns whether the B plot phase display is enabled. This is a query command.
Returns the current phase position of the BPlot display.
Returns the phase scale for the B plot.
Sets the number of logarithmic points used for the B plot. The command is listed under the BPLot subsystem and corresponds to the logarithmic point setting.
Sets the repeat behavior for the BPLot function.
Resets the BPlot settings to their default state.
Turns the B plot display on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the B plot display. |
Calibrates the instrument. The query form returns the calibration state.
Returns the calibration state. This is the query form of CALibration:STATe.
Turns the selected channel off.
Returns the header information for envelope data of the specified channel.
Returns the X increment for the selected channel’s envelope data. The value is used for waveform scaling in the envelope data transfer format.
Returns the X-origin for the channel envelope data.
Returns the Y origin for envelope data of the specified channel.
Returns the Y resolution for envelope data of the selected channel.
Returns envelope data for the selected channel.
Returns the header setting for channel waveform data.
Sets the number of data points returned by the channel data query. This command is part of the channel data transfer settings.
| Name | Type | Values | Description |
|---|---|---|---|
| points | integer | 1 | Number of points to return. |
Returns the X increment for the specified channel data. The command is a query.
Returns the Y increment for the selected channel data. This is a query command.
Returns the Y-origin of the selected channel data. This query is part of the channel data scaling/readout commands.
Controls whether history control is enabled for the selected channel. This command is listed as an optional-node form under the channel history control subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| enableopt | enum | ENABle | Enables history control. |
Saves the history data of the selected channel to a file. The command is part of the channel history export functions.
PALL is a channel history command listed in the RTM3000 command index. The provided slice does not include its syntax or functional description.
Sets the history player speed for the selected channel history display.
Turns the history player on or off for the selected channel's history mode.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the history player. |
Starts replay of the channel history data.
Starts history recording for the selected channel.
Stops history recording on the specified channel.
Sets the history time mode for channel <m>.
Returns all absolute time stamps of the selected history record. The channel number is specified by <m>.
Returns the absolute time stamp of the current history entry for channel m.
Returns the date/time information for all history entries. This is the query form for the channel history timestamp date command.
Returns the date timestamp for the selected history acquisition. The command belongs to the channel history timestamp group.
Returns the relative time stamps of all history entries for the selected channel.
Returns the relative timestamp for the selected history record. The command is a query for channel history time relative information.
Enables or disables the history table for the selected channel history. The command is listed as an optional [:ENABle] node under CHANnel<m>:HISTory:TTABle.
| Name | Type | Values | Description |
|---|---|---|---|
| enableopt | enum | ENABle | Enables the history table. |
Sets the label for the specified channel.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | 1 - 4 | Channel number. |
| label | string | - | Label text to assign to the channel. |
Sets or queries the label state for channel m.
Sets the vertical offset of the selected channel.
| Name | Type | Values | Description |
|---|---|---|---|
| offset | real | - | Vertical offset value for the selected channel. |
Sets or queries the overload state of the specified channel.
Sets the polarity of channel <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | INVerted | NORMal | Selects the channel polarity. |
Sets the vertical position of the selected channel trace on the display.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | 1 | Channel index. |
| position | real | - | Vertical position of the channel. |
Sets the vertical range of channel <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| range | real | 0.0 - 1E12 | Vertical range of channel <m>. |
Sets the vertical scale of the specified channel.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Channel number. |
Sets the skew between the specified channel and the trigger signal.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Channel index. |
Sets the state of the selected channel. The command is available for channel index <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the selected channel. |
Sets the threshold for channel m.
Finds the threshold level on the selected channel. The command is documented as part of the channel threshold functions.
Sets the hysteresis of the channel threshold. The command belongs to the channel threshold subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| hysteresis | real | 0 - 100 | Hysteresis value as a percentage of the threshold. |
Selects the type of the specified channel. The available channel types are documented on the command’s detail page.
Sets the waveform color for the specified channel.
Sets the vertical zero offset value for the selected channel.
| Name | Type | Values | Description |
|---|---|---|---|
| m | integer | - | Channel number to which the offset applies. |
| valueopt | real | - | Zero offset value. |
Turns off all cursors for the selected cursor set.
Selects the cursor function mode.
| Name | Type | Values | Description |
|---|---|---|---|
| function | enum | - |
Sets or queries the cursor snap peak function for cursor m and n. The command belongs to the cursor subsystem.
Selects the source signal for the cursor measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - |
Sets the spectrum peak cursor for cursor <m> and peak number <n>.
Selects the source used for cursor measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - |
Turns the selected cursor on or off. The cursor mode is selected per cursor index <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the cursor. |
Switches the cursor display to waveform mode. The command is part of the cursor subsystem for cursor m.
Controls whether tracking scale is enabled for the selected cursor. The optional state setting is documented with the tracking scale command family.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | ON | OFF | Enables or disables tracking scale. |
Turns cursor tracking on or off for the specified cursor. The optional state node is shown in brackets in the syntax list.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | ON | OFF | Enables or disables cursor tracking. |
Selects the user source for cursor measurements.
Sets the X1 position of cursor m.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | X1 position of the cursor. |
Returns whether cursor X-delta inversion is enabled for cursor m.
Returns the current X delta value of the selected cursor. The optional :VALue node is part of the query mnemonic.
Sets the Y coupling mode for cursor <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| coupling | enum | - |
Returns the delta between the cursor's Y values on slope cursor m.
Returns the Y delta value of cursor <m>.
Installs the diagnostic update package. This command is listed as a non-query command and the slice provides no further syntax or behavior details.
Closes the diagnostic update transfer. This command is part of the diagnostic update transfer sequence together with OPEN and DATA.
Transfers update data for the diagnostic update function.
Opens a diagnostic update transfer session. It is listed together with the related DIAGnostic:UPDate:TRANsfer:CLOSe and :DATA commands.
Enables or disables the specified DVM meter. The meter is selected by the <m> suffix.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the DVM meter on or off. |
Returns the status of the actual DVM result for measurement <m>.
Returns the current DVM actual result for measurement <m>.
Sets or queries the source used by the selected digital voltmeter measurement. The command is parameterized by the DVM measurement index m.
Sets the DVM measurement type for the selected DVM channel <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | - | Measurement type to use. |
Sets the file name used for exporting an A table.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | File name for the export A table. |
Saves the table export using the currently set table name. This command is listed as part of the EXPort:ATABle command group.
Sets the name used for exporting all measurement statistics. This command belongs to the measurement statistics export subsystem.
Saves the statistics of all measurements to a file. This command belongs to the export subsystem for measurement statistics.
Sets the file name used for exporting measurement statistics for the selected measurement. The measurement is identified by <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | File name for the exported measurement statistics. |
Saves the statistics export for a specific measurement. The measurement is selected by the `<m>` index.
Sets or queries the file name used for power export. The command is documented in the export command list but the slice does not provide syntax or parameter details for this page reference.
Saves the power export to a file. This command is listed in the export power command group; no syntax or parameter details are shown on this page slice.
Sets the destination for screen captures saved by the export function.
| Name | Type | Values | Description |
|---|---|---|---|
| destination | enum | - | Destination for screen capture files. |
Sets the file name used for export search operations.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | File name for the export search operation. |
Saves the current search export settings or search data, depending on the instrument context. The manual slice only lists the command in the command index and does not provide syntax or parameter details.
Sets or queries the filename used for waveform export. The command is part of the waveform export subsystem.
Saves the selected waveform export data. The command is listed under the waveform export subsystem and is associated with waveform source and name commands.
Selects the source waveform for export. The command is listed with related export waveform commands, but this page slice does not provide syntax or parameter details.
Sets the destination for waveform file export.
| Name | Type | Values | Description |
|---|---|---|---|
| destination | enum | INTernal | EXTernal | Selects the export destination. |
Sets the byte order used for data transfer. The command configures the format border setting.
| Name | Type | Values | Description |
|---|---|---|---|
| border | enum | NORMal | SWAPped | Byte order used for transferred data. |
Selects the data format used for waveform and measurement data transfers. The command is listed as an optional-node form under the FORMAT subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| format | enum | - | Data format to use. |
Returns the hardcopy data.
Sets the output file format used for hardcopy data. This command is part of the HCOPy hardcopy subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| format | enum | - | Output file format for hardcopy data. |
Sets the language used for hardcopy output. The command is listed in the hardcopy command group; no syntax or parameter details are shown on this index page.
Returns the horizontal hardcopy size.
Queries the current Y dimension used for hardcopy size. The command is listed in the hardcopy (HCOPy) command set.
Selects the hardcopy immediate action. The optional node indicates the immediate form of the HCOPy command.
Sets the event mode for pulse action on mask violations.
Sets the destination used for screen save actions triggered by a mask event.
| Name | Type | Values | Description |
|---|---|---|---|
| destination | enum | - | Destination used for the screen save action. |
Sets the event mode for the screen save action of the mask test function.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Event mode for screen saving. |
Sets the number of stop events after which mask action stops. The command belongs to the mask action stop-event configuration.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 0 - 2147483647 | Number of stop events. |
Sets the mask capture mode. The mode is selected from a fixed list of keywords.
| Name | Type | Values | Description |
|---|---|---|---|
| modeopt | enum | - | Capture mode to use. |
Copies the currently selected mask to another channel. The command is part of the MASK subsystem.
Returns the current mask count.
Returns the header of the mask data block. The command is a query and yields the data header information for the current mask data set.
Returns the x increment of the mask data. This is the horizontal spacing between adjacent data points.
Returns the X-origin value for the mask data. It is listed as a query under the MASK:DATA command group.
Returns the Y increment for mask data.
Returns the Y resolution of the mask data. The value is reported for the selected mask data set.
Returns the mask data. The command is listed under the MASK subsystem's data commands.
Loads a mask from a file or other storage location.
Resets the mask test counter.
Saves the current mask definition to internal memory.
Sets the source used for mask testing. The command is listed in the command index on the same page as related MASK commands.
Sets the state of the mask test function.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns mask testing on or off. |
Performs a mask test operation.
Returns the current mask test count. The command is listed in the mask command index.
Sets the X width of the mask test area.
| Name | Type | Values | Description |
|---|---|---|---|
| width | real | - | X width of the mask test area. |
Sets the vertical position of the mask. The command is part of the MASK subsystem for mask test configuration.
Sets the Y-scale of the mask. This command is listed in the mask command index alongside related X/Y position and width settings.
| Name | Type | Values | Description |
|---|---|---|---|
| YScale | real | - | Y-scale of the mask. |
Sets the Y width of the mask. The command is listed in the mask command index; the detailed definition appears on page 538.
Enables or disables the selected measurement. The command is part of the measurement subsystem for measurement m.
| Name | Type | Values | Description |
|---|---|---|---|
| stateopt | enum | ON | OFF | Turns the measurement on or off. |
Turns off automatic measurement selection for measurement m. This command is the counterpart to MEASurement<m>:AON.
Enables automatic acquisition for measurement m. It is the counterpart to :MEASurement<m>:AOFF and is listed under the measurement subsystem.
Returns the measurement result for measurement <m>.
Sets the direction used for delay measurements of the selected measurement. The command belongs to the MEASurement<m> subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | - | Delay measurement direction. |
Sets the marker used for delay measurements. The command is part of the MEASurement<m>:DELay subsystem.
Sets the slope used for delay measurements. The command belongs to the measurement subsystem for channel or math measurement <m>.
Sets the gate for the selected measurement. The gate can be set for absolute or relative start and stop positions, with gate mode selected separately.
Sets the absolute start of the gate for measurement <m>.
Sets the absolute stop position of the gate for measurement m. This command is part of the MEASurement<m>:GATE subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| stop | real | - | Absolute gate stop position. |
Sets the gate mode for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Gate mode for the measurement. |
Sets the relative start position of the measurement gate. The command is part of the measurement gate configuration subtree.
Sets the relative gate stop position for measurement <m>.
Sets the main measurement selection for measurement m.
Returns the average value of the measurement result. It is a query for measurement <m>.
Returns the number of peaks in the current measurement result. This is a query of the measurement result subsystem for measurement <m>.
Returns the present peak-peak measurement result for measurement <m>.
Returns the standard deviation of the measurement result for measurement m.
Returns the waveform count result of the selected measurement. This is a measurement result query under MEASurement<m>:RESult.
Returns the actual measurement result for measurement m. The optional :ACTual node is shown in the syntax and the command is documented as a query.
Sets the source for measurement <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Measurement source. |
Resets the measurement statistics for measurement m.
Returns all statistics values for the selected measurement item.
Returns one statistic value from the measurement statistics array for the specified measurement. The command is indexed by measurement <m> and statistic number <n>.
Returns the weighting used for statistics of measurement <m>.
Enables or disables measurement statistics for the selected measurement. This command is the optional form of the measurement statistics enable setting.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns measurement statistics on or off. |
Sets the automatic timeout for measurements. This command belongs to the measurement subsystem for measurement m.
Sets the measurement timeout for measurement <m>. The timeout can also be turned off automatically with the related :MEASurement<m>:TIMeout:AUTO command.
| Name | Type | Values | Description |
|---|---|---|---|
| TIMEopt | real | s | Measurement timeout value. |
Enables or disables measurement <m>. The optional node variant is listed as MEASurement<m>[:ENABle].
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the measurement on or off. |
Returns the number of files in the current directory catalog.
Returns a catalog of files in the mass memory. The response lists the contents of the current directory.
Sets the current directory for mass memory operations.
| Name | Type | Values | Description |
|---|---|---|---|
| directory | string | - | Directory to set as the current mass memory directory. |
Copies a file from one location to another in mass memory.
| Name | Type | Values | Description |
|---|---|---|---|
| source | string | - | Source file or path. |
| destination | string | - | Destination file or path. |
Returns the number of entries in the directory catalog. Use this query to determine how many files or items are contained in the selected directory.
Returns the names of the directories and files on the selected storage device. The command is documented on the memory catalog page and has a related length query.
Deletes a file or directory from the mass memory. The command is part of the mass memory (MMEMory) command set.
Returns the available drives.
Loads a previously stored state from mass memory. The state file is selected by the command parameters documented on the command page.
Sets the current working directory in the mass memory. The command is listed in the command index for mass memory directory handling.
Moves a file or directory to a new name or location. The command is listed in the MMEMory command group.
Moves a file or directory in the internal memory. The command is listed in the memory command index on the referenced manual page.
Stores the current state in a file. The command creates a file with the specified name in the current directory or in the directory specified by the MMEMory:MDIRectory command.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | Name of the file to create. |
Sets the function of the pulse generator.
Sets or queries the manual state for the selected signal generator source <s>.
| Name | Type | Values | Description |
|---|---|---|---|
| s | enum | - | Signal generator source identifier. |
Appends a band value to the arbitrary pattern data. The command belongs to the PGenerator arbitrary pattern data append set.
Appends an index to the arbitrary pattern data. The command is listed under the PGENerator pattern arbitrary data append commands.
Sets the length of the arbitrary pattern data. The command belongs to the pattern generator arbitrary data subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| length | integer | 0 | Length of the arbitrary pattern data. |
Sets or appends arbitrary pattern data for the pulse generator pattern arbitrary data memory. The command is documented as an optional-node form of the base DATA command.
Sets the number of cycles used for pattern burst generation.
| Name | Type | Values | Description |
|---|---|---|---|
| ncycles | integer | 1 - 65535 | Number of burst cycles. |
Sets the counter direction for the pattern generator.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | - | Counter direction. |
Sets the frequency for the pattern counter signal of the pattern generator. The value determines the output frequency used by the counter mode.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | 1 - 1000000 | Frequency of the pattern counter signal. |
Sets the integration time for the pattern generator. The command belongs to the pattern generator settings block.
Sets the green LED state for the pattern generator.
Sets the red LED component of the pattern generator. The slice only lists the command name in the command index and provides no syntax or parameter details.
Sets the period of the pattern generator output. The period is used for pattern generation timing.
| Name | Type | Values | Description |
|---|---|---|---|
| period | real | s | Pattern period. |
Sets the PWM direction for the pattern generator. The command belongs to the PGENerator:PATTern:PWM subsystem.
Enables the PWM function for the pattern generator. The command is part of the pattern generator PWM subsystem.
Sets the duty cycle of the squarewave pattern.
| Name | Type | Values | Description |
|---|---|---|---|
| duty cycle | real | 0 - 100 | Duty cycle of the squarewave pattern. |
Sets the polarity of the squarewave pattern generator output. The command belongs to the pattern generator squarewave settings.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity setting for the squarewave pattern. |
Sets the trigger time for pattern generation. The command is listed in the pattern generator command index.
Sets the trigger mode for the pattern generator.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Trigger mode setting. |
Triggers a single pattern-generator action. The slice only shows the command in the command list and does not provide syntax or parameter details.
Returns the build information of the selected probe.
Returns the part number of the selected probe. The command is part of the probe identification queries.
Returns the probe production date.
Returns the probe serial number.
Returns the software version of the selected probe.
Returns the common measurement results for the selected probe meter. The command is a query and yields the common result values for PROBe<m>:PMETer:RESults.
Returns the differential measurement results of the selected probe meter channel.
Returns the negative pMeter result for probe <m>.
Returns the positive p-meter results for probe <m>.
Returns the single probe meter result for the selected probe channel. The command is a query for the probe meter measurement results.
Controls the visibility of the probe meter for the selected probe channel.
Sets the probe coupling configuration.
Sets the audio overload setup of probe m. The command is listed under probe advanced setup commands, but this page slice does not provide syntax, parameter details, or a return value.
Sets the advanced probe filter setting for probe m.
Sets the probe meter offset for the selected probe channel.
Sets the advanced probe range. The command is part of the probe setup tree for probe <m>.
Starts the probe setup advanced stop-probe function for channel m. The command is part of the probe setup subsystem and is documented on the probe advanced setup page.
Adjusts the probe setup in an advanced calibration procedure.
Sets the manual probe attenuation for channel m.
| Name | Type | Values | Description |
|---|---|---|---|
| attenuation | real | 0.1 - 1000 | Manual attenuation value. |
Sets the unit used for probe attenuation settings. The command is part of the probe setup subtree.
Returns the probe attenuation auto setting for the specified probe channel. If the optional AUTO node is omitted, the command applies to the attenuation setup state as documented for this query.
Returns the probe bandwidth setting.
Returns the probe setup capacitance. The command is listed as a query in the command index, but this page slice does not provide any further details.
Returns the probe DC offset setting for channel m.
Degausses the selected probe. The command is shown under probe setup commands and takes no parameters.
Sets the manual probe gain setup for probe <m>.
Sets the unit used for probe gain configuration.
Returns the automatic gain setting for the probe setup. The command is a query for the probe's gain configuration.
Returns the probe input impedance setting for probe m.
Sets the probe setup mode. The command belongs to the probe setup subsystem.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - |
Queries the name of the selected probe setup. The command belongs to the probe setup subsystem for channel/probe <m>.
Sets the probe offset switch state. The command is listed under probe setup commands for channel/probe <m>.
Sets the probe setup mode for probe <m>.
Returns the probe setup type for probe <m>.
Sets the Z-axis voltage scaling for probe setup.
Returns the header information of the selected reference curve.
Returns the horizontal increment between data points in the reference curve.
Returns the X origin value for the reference curve data.
Returns the vertical increment of the reference curve data. This is a query command for reference curve m.
Returns the Y origin of the referenced curve data.
Returns the y-resolution of the reference curve data.
Returns the complete contents of a reference curve data record. The command is documented together with related header and axis-scaling queries for reference curves.
Sets the horizontal scale of the selected reference curve. The command belongs to the REFCurve<m> subsystem and adjusts the time/division setting for the curve display.
| Name | Type | Values | Description |
|---|---|---|---|
| scale | real | - | Horizontal scale for the reference curve. |
Loads a reference curve into the selected reference memory. The command is available for reference curve memory m.
Sets the state of a reference curve loaded from memory. This command belongs to the REFCurve<m> command group.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - |
Saves the current reference curve. The command is listed without parameters on the command index page.
Selects the source of the reference curve.
Returns the source catalog for the referenced curve.
Sets the state of the reference curve. The command applies to reference curve <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | State of the reference curve. |
Sets the vertical position of the selected reference curve. The command applies to reference curves identified by <m>.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Vertical position of the reference curve. |
Sets the color used for the referenced curve. This command belongs to the REFCurve<m> command group.
Sets the upper threshold used for the REFLevel relative mode. The slice only shows the command listing, so no syntax details are provided.
Starts continuous acquisition. This is the RUN command in the command list.
Starts continuous acquisition/run mode.
Starts a single acquisition. The command is listed in the command index without further syntax or parameter details on this page slice.
Initiates a single acquisition sequence. The instrument performs one trigger event and then stops.
SINGle
Stops the acquisition.
Returns the actual counter frequency result.
Returns the measured period from the actual counter result.
Sets the timebase position. The command is listed in the command index with no further syntax or parameter details on this page slice.
Sets the zoom state of the timebase. The command is listed in the timebase zoom command group.
Sets the start value of the arbitrary waveform range.
| Name | Type | Values | Description |
|---|---|---|---|
| start | real | - | Start value of the arbitrary waveform range. |
Sets the stop value of the arbitrary waveform range. It is listed under the arbitrary waveform generator range commands.
Selects the source used for the arbitrary waveform generator. The command is listed in the waveform generator arbitrary settings group.
Controls whether the arbitrary waveform is visible in the waveform list or browser. The command is listed in the arbitrary waveform generator command set.
Sets or queries the name of the arbitrary waveform file. The optional [:FILE] node is part of the command name as listed in the manual.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | Name of the arbitrary waveform file. |
Opens an arbitrary waveform file. The command is documented under the arbitrary waveform file subsection.
Sets the burst interval time of the waveform generator.
| Name | Type | Values | Description |
|---|---|---|---|
| time | real | 0 - 1E9 | Burst interval time. |
Sets the number of cycles in a burst. This command is part of the waveform generator burst settings.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 | Number of cycles in a burst. |
Starts a single burst trigger for the waveform generator.
Sets the trigger mode for the burst function of the waveform generator.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | - | Trigger mode for burst operation. |
Enables or disables burst mode for the waveform generator. The optional node is the burst state setting.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns burst mode on or off. |
Sets the waveform generator frequency.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | 0 - 100 MHz | Frequency setting for the waveform generator. |
Sets the pulse duty cycle used by the waveform generator function. The duty cycle is specified as a percentage.
| Name | Type | Values | Description |
|---|---|---|---|
| duty cycle | real | 0 - 100 | Pulse duty cycle in percent. |
Sets the pulse fall time for the arbitrary waveform generator function.
| Name | Type | Values | Description |
|---|---|---|---|
| etime | real | 0 - 20 | Pulse fall time. |
Sets the polarity of the waveform generator ramp function.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | - | Polarity of the ramp function. |
Sets the high frequency for FSK modulation of the waveform generator.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | 10 Hz - 50.00 kHz | High FSK frequency. |
Sets the FSK modulation rate of the waveform generator.
| Name | Type | Values | Description |
|---|---|---|---|
| rate | real | 0.1 - 1000000 | FSK modulation rate. |
Enables or disables waveform generator modulation. The command is listed as the modulation enable command in the function generator command tree.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns modulation on or off. |
Sets the output load of the waveform generator.
| Name | Type | Values | Description |
|---|---|---|---|
| load | real | MINimum - MAXimum | Output load value. |
Sets the waveform generator output voltage. The command is listed in the WGENerator command tree; no further syntax or parameter details are shown on this page slice.