Sets or queries the clock source threshold for the specified ESPI bus.
SCPI COMMAND REFERENCE
The Tektronix MSO66B is Tektronix's oscilloscope in the 6 Series MSO family. Its SCPI remote-control interface exposes 4661 commands across 109 subsystems - 3198 settable and 1463 queries - and every command is documented here with its parameters, accepted values, return format, and a copy-paste PyVISA example for automating test and measurement.
4,661
Commands
3,198
Settable
1,463
Queries
109
Subsystems
SCPI
Verified
2026-07-16
All commands
Sets or queries the waveform label for the specified bus.
Sets or queries the Manchester header length in bits.
Sets or queries the Manchester idle bit size in bits.
| Name | Type | Values | Description |
|---|---|---|---|
| bits | integer | 0 - 15 | Idle bit size in bits. |
Sets or queries the Manchester source for the specified bus.
Sets or queries the Manchester start index in bits.
Sets or queries the Manchester sync bit size in bits for the specified bus.
Sets or queries the Manchester threshold for the specified bus.
Sets or queries the tolerance bus parameter for the Manchester bus.
Sets or queries the Manchester bus transition setting for zero, selecting falling or rising.
Sets or queries the Manchester trailer length in bits.
Sets or queries the Manchester word count in bits.
Sets or queries the Manchester word size in bits.
Sets or queries the Manchester bus parity.
Sets or queries the MDIO clock source for the specified bus.
Sets or queries the MDIO clock source threshold for the specified bus.
Sets or queries the MDIO data source for the specified bus.
Sets or queries the MDIO data source threshold for the specified bus.
Sets or queries the MIL-STD-1553 lower threshold for the specified bus.
Sets or queries the source polarity for the specified MIL-STD-1553 bus.
Sets or queries the minimum response time to a valid command issued for the specified MIL-STD-1553 bus.
Sets or queries the source for the specified MIL-STD-1553 bus.
Sets or queries the MIL-STD-1553 upper threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | Upper threshold for the specified bus. |
Sets or queries the demodulation application for the specified bus.
Sets or queries the bit rate for the specified NFC bus on the response lane.
Sets or queries the Manchester start index for the NFC command signal type for the specified bus.
Sets or queries the command threshold for the specified NFC bus.
Sets or queries the Manchester type for the NFC command signal type for the specified bus.
Sets or queries the polarity for NFC Type B command signal type for the specified bus.
Sets or queries the polarity for NFC Type B response signal type for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | channel_list | - | Specifies the bus. |
Sets or queries the response threshold for the specified NFC bus.
Sets or queries the source for the specified NFC bus.
Sets or queries the Manchester start index for the specified NFC command signal type for the specified bus.
Sets or queries the standard for the specified NFC bus.
Sets or queries the tolerance for the specified NFC bus.
Sets or queries the Manchester standard convention for the specified NFC bus on the response lane.
Sets or queries the NRZ bit order for the specified bus.
Sets or queries the NRZ bus bit rate for the specified bus.
Sets or queries the NRZ source polarity for the specified bus.
Sets or queries the NRZ source for the specified bus.
Sets or queries the Version for the specified bus.
Sets or queries the NRZ threshold for the specified bus.
Sets or queries the source for the specified ONEWIRe bus.
Sets or queries the ONEWIRe data source threshold for the specified bus.
Sets or queries the mode for the specified ONEWIRe bus.
Sets or queries the threshold for all sources for the parallel bus.
Sets all of the data source thresholds to the value of the allMRefs parameter for the parallel bus.
Sets or queries the specified bit source for the specified parallel bus.
Sets or queries the specified bit source threshold for the specified parallel bus.
Adds the specified bus. It creates the bus but does not display it; bus decoding and display must be enabled separately.
Sets or queries the ARINC429 bit rate for the specified bus. Use the custom-bit-rate command if Custom is selected.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LOW | HI | CUSTom | Selects the ARINC429 bit rate setting for the bus. |
BUS:B1:ARINC429A:BITRATE LOW BUS:B1:ARINC429A:BITRATE?
Sets or queries the ARINC429 bit rate for the specified bus. Use the custom bit rate command if you select Custom.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LOW | HI | CUSTom | Selects the ARINC429 bit rate mode. |
BUS:B1:ARINC429A:BITRATE LOW BUS:B1:ARINC429A:BITRATE? might return :BUS:B1:ARINC429A:BITRATE HI, indicating the bit rate is set to handle high speed signals.
Sets or queries the custom ARINC429 bit rate for the specified bus. Requires option SR-AERO.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| bit rate | real | - | The ARINC429 custom bit rate for the specified bus. |
BUS:B1:ARINC429A:BITRATE:CUSTOM 12500 BUS:B1:ARINC429A:BITRATE:CUSTOM?
Queries the custom ARINC429 bit rate for the specified bus. Requires option SR-AERO.
BUS:B1:ARINC429A:BITRATE:CUSTOM? might return :BUS:B1:ARINC429A:BITRATE:CUSTOM 100000, indicating the bit rate is set to 100,000.
Sets or queries the format of the DATA field for the specified ARINC429 bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| format | enum | DATA | SDIDATA | SDIDATASSM | Selects the DATA field width. |
BUS:B1:ARINC429A:DATAFORMAT SDIDATASSM sets Bus 1 ARINC429 DATA field width to 23 bits. BUS:B1:ARINC429A:DATAFORMAT? might return :BUS:B1:ARINC429A:DATAFORMAT DATA, indicating a DATA field width of 19 bits.
Sets or queries the format of the DATA field for the specified ARINC429 bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| format | enum | DATA | SDIDATA | SDIDATASSM | Selects the DATA field width for the ARINC429 bus. |
BUS:B1:ARINC429A:DATAFORMAT SDIDATASSM BUS:B1:ARINC429A:DATAFORMAT? might return :BUS:B1:ARINC429A:DATAFORMAT DATA, indicating a DATA field width of 19 bits.
Sets or queries the source polarity for the specified ARINC429 bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | NORMal | INVERTed | Specifies normal or inverted polarity. |
BUS:B3:ARINC429A:POLARITY INVERTED BUS:B2:ARINC429A:POLARITY?
Sets or queries the source polarity for the specified ARINC429 bus. The bus is specified by x; requires option SR-AERO.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | NORMal | INVERTed | Specifies normal or inverted polarity. |
BUS:B3:ARINC429A:POLARITY INVERTED BUS:B2:ARINC429A:POLARITY?
Sets or queries the source waveform for the specified ARINC429 bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform for the ARINC429 bus. |
BUS:B1:ARINC429A:SOUrce CH1 sets channel 1 as the source for the ARINC429 bus. BUS:B1:ARINC429A:SOUrce? might return :BUS:B1:ARINC429A:SOUrce MATH2 indicating that the source is set to MATH2.
Sets or queries the source waveform for the specified ARINC429 bus. The bus is specified by x.
BUS:B1:ARINC429A:SOUrce CH1 BUS:B1:ARINC429A:SOUrce? might return :BUS:B1:ARINC429A:SOUrce MATH2
Sets or queries the ARINC429 upper threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | V | The ARINC429 upper threshold for the specified bus. |
BUS:B3:ARINC429A:THRESHOLD -200e-3 BUS:B2:ARINC429A:THRESHOLD?
Sets or queries the ARINC429 upper threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | V | The ARINC429 upper threshold for the specified bus. |
BUS:B3:ARINC429A:THRESHOLD -200e-3 BUS:B2:ARINC429A:THRESHOLD?
Sets or queries the number of delay bits for the specified AUDIO bus. This command only applies to the TDM Audio type.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| delay bits | integer | - | Specifies the number of delay bits. |
BUS:B1:AUDIO:BITDELAY 2 BUS:B1:AUDIO:BITDELAY?
Sets or queries the number of delay bits for the specified AUDIO bus. This command only applies to the TDM Audio type.
BUS:B1:AUDIO:BITDELAY 2 BUS:B1:AUDIO:BITDELAY?
Specifies the bit order for the specified AUDIO bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| order | enum | MSB | LSB | Selects whether the most significant bit or least significant bit is expected first. |
BUS:B1:AUDIO:BITORDER LSB BUS:B1:AUDIO:BITORDER?
Specifies the bit order for the specified AUDIO bus. The bus is specified by x.
BUS:B1:AUDIO:BITORDER LSB BUS:B1:AUDIO:BITORDER?
Sets or queries the clock source polarity for the specified AUDIO bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | FALL | RISE | Sets the clock polarity to falling or rising edge. |
BUS:B1:AUDIO:CLOCK:POLARITY FALL BUS:B1:AUDIO:CLOCK:POLARITY?
Sets or queries the clock source polarity for the specified AUDIO bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | FALL | RISE | Sets falling edge or rising edge as the clock polarity. |
BUS:B1:AUDIO:CLOCK:POLARITY FALL BUS:B1:AUDIO:CLOCK:POLARITY?
Sets or queries the clock source waveform for the specified AUDIO bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Clock source waveform for the audio bus. |
BUS:B1:AUDIO:CLOCK:SOURCE CH1 BUS:B1:AUDIO:CLOCK:SOURCE?
Sets or queries the audio clock source threshold for the specified AUDIO bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | The audio clock source threshold for the specified bus. |
Sets or queries the audio clock source threshold for the specified bus. The bus is specified by x.
Sets or queries the audio data source polarity for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HIGH | LOW | Specifies positive or negative data polarity for the audio bus. |
BUS:B1:AUDIO:DATA:POLARITY LOW BUS:B1:AUDIO:DATA:POLARITY?
Sets or queries the audio data source polarity for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Specifies positive or negative data polarity for the audio bus. |
BUS:B1:AUDIO:DATA:POLARITY LOW BUS:B1:AUDIO:DATA:POLARITY? might return :BUS:B1:AUDIO:POLARITY HIGH
Sets or queries the number of bits per channel for the specified audio bus. This command only applies to the TDM Audio type.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| bits per word | integer | - | Specifies the number of bits per word. |
Sets or queries the number of bits per channel for the specified audio bus. This command only applies to the TDM Audio type.
Sets or queries the audio data source for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Audio waveform source for the bus. |
BUS:B1:AUDIO:DATA:SOURCE CH1 BUS:B1:AUDIO:DATA:SOURCE?
Sets or queries the audio data source for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Specifies the data source waveform for the audio bus. |
BUS:B1:AUDIO:DATA:SOURCE CH1 sets the data source to channel 1. BUS:B1:AUDIO:DATA:SOURCE? might return :BUS:B1:AUDIO:DATA:SOURCE CH3 indicating that the data source is set to CH3.
Sets or queries the audio data source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | The number of the bus. |
| threshold | real | - | The audio data source threshold value. |
Sets or queries the audio data source threshold for the specified bus. The bus is specified by x.
Sets or queries the audio bits per word for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| NR1 | integer | - | The audio bits per word for the specified bus. |
BUS:B1:AUDio:DATa:WORDSize 24 BUS:B1:AUDio:DATa:WORDSize?
Sets or queries the audio bits per word for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Bus number. |
| value | integer | - | Audio bits per word for the specified bus. |
BUS:B1:AUDio:DATa:WORDSize 24 sets the audio bits per word to 24 bits. BUS:B1:AUDio:DATa:WORDSize? might return :BUS:B1:AUDIO:DATA:WORDSIZE 24 indicating the bits per word is 24.
Sets or queries the audio bits of sync width for the specified bus. This command only applies to the TDM Audio type and requires option SR-AUDIO.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| <NR1> | integer | - | The audio bits of sync width for the specified bus. |
Sets or queries the audio bits of sync width for the specified bus. This command only applies to the TDM Audio type and requires option SR-AUDIO.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| bits | integer | - | The audio bits of sync width for the specified bus. |
Sets or queries the number of audio channels in each frame for the specified AUDIO bus. This command applies only to the TDM Audio type and requires option SR-AUDIO.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| <NR1> | integer | - | Specifies the number of channels in each frame. |
BUS:B1:AUDIO:FRAME:SIZE 2 BUS:B1:AUDIO:FRAME:SIZE? might return :BUS:B1:AUDIO:FRAME:SIZE 8 indicating that the number of channels in each frame is set to 8.
Sets or queries the number of audio channels in each frame for the specified audio bus. This command only applies to the TDM Audio type and requires option SR-AUDIO.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | The bus number. |
| count | integer | - | The number of channels in each frame. |
BUS:B1:AUDIO:FRAME:SIZE 2 BUS:B1:AUDIO:FRAME:SIZE?
Sets or queries the audio format (type) for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | I2S | LJ | RJ | TDM | Audio format for the specified bus. |
Sets or queries the audio format (type) for the specified audio bus. The bus is specified by x.
Sets or queries the word select source polarity for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | NORMal | INVERTed | Selects positive or negative polarity. |
BUS:B1:AUDIO:WORDSEL:POLARITY NORMal sets normal as the word select polarity. BUS:B1:AUDIO:WORDSEl:POLARITY? might return :BUS:B1:AUDIO:WORDSEL:POLARITY NORMAL indicating that the word select polarity is set to normal.
Sets or queries the word select source polarity for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | NORMal | INVERTed | Specifies positive or negative word select polarity. |
BUS:B1:AUDIO:WORDSEL:POLARITY NORMal sets normal as the word select polarity. BUS:B1:AUDIO:WORDSEl:POLARITY? might return :BUS:B1:AUDIO:WORDSEL:POLARITY NORMAL indicating that the word select polarity is set to normal.
Sets or queries the audio word select source waveform for the specified audio bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Audio word select source waveform for the specified bus. |
Queries the word select source for the specified audio bus. The source may be a channel, math waveform, reference waveform, or digital reference waveform.
BUS:B1:AUDIO:WORDSEL:SOURCE CH1 sets CH1 as the word select source. BUS:B1:AUDIO:WORDSEL:SOURCE? might return :BUS:B1:AUDIO:WORDSEL:SOURCE CH2 indicating that the word select source is set to CH2.
Sets or queries the audio word select source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| b<x> | - | - | The bus number. |
| threshold | real | - | The audio word select source threshold for the specified bus. |
BUS:B4:AUDIO:WORDSEL:THRESHOLD 300.0E-3 BUS:B1:AUDIO:WORDSEL:THRESHOLD?
Sets or queries the audio word select source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | Audio word select source threshold for the specified bus. |
BUS:B4:AUDIO:WORDSEL:THRESHOLD 300.0E-3 sets the Bus 4 audio word select source threshold to 300 mV. BUS:B1:AUDIO:WORDSEL:THRESHOLD? might return :BUS:B1:AUDIO:WORDSEL:THRESHOLD 1.25 indicates the Bus 1 audio word select source threshold is set to 1.25 V.
Sets or queries the bitrate for Auto Ethernet Bus with speed 10Base-T1S.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
| bitrate | numeric | - | Bit input for the rate argument. |
Sets or queries the bitrate for Auto Ethernet Bus with speed 10Base-T1S. The bus is specified by x.
Sets or queries the AutoEthernet D– source threshold level for the specified bus. This threshold only applies when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | AutoEthernet D– source threshold level for the specified bus. |
BUS:B3:AUTOETHERnet:DATAMINUSTHRESHOLD 250.0E-3 BUS:B2:AUTOETHERnet:DATAMINUSTHRESHOLD? might return BUS:B2:AUTOETHERnet:DATAMINUSTHRESHOLD 1.0
Sets or queries the AutoEthernet D– source threshold level for the specified bus. This threshold only applies when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | AutoEthernet D– source threshold level for the specified bus. |
BUS:B3:AUTOETHERnet:DATAMINUSTHRESHOLD 250.0E-3 BUS:B2:AUTOETHERnet:DATAMINUSTHRESHOLD?
Sets or queries the AutoEthernet D+ source threshold level for the specified bus. This threshold applies only when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | discrete | - | Bus number. |
| threshold | real | V | AutoEthernet D+ source threshold level for the specified bus. |
Sets or queries the AutoEthernet D+ source threshold level for the specified bus. This threshold applies only when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
| NR3 | real | V | AutoEthernet D+ source threshold level for the specified bus. |
Sets the AutoEthernet D+ source threshold for the specified bus. This threshold applies only when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | AutoEthernet D+ source threshold for the specified bus. |
BUS:B3:AUTOEthernet:DATAPLUSTHRESHOLD 250.0E-3 BUS:B2:AUTOEthernet:DATAPLUSTHRESHOLD?
Sets or queries the AutoEthernet D– source low threshold level for the specified bus. This threshold only applies when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The Bus number. |
| threshold | real | V | AutoEthernet D– source low threshold level for the specified bus. |
BUS:B1:AUTOEthernet:LOWDATAMINus 250.0E-3 BUS:B2:AUTOEthernet:LOWDATAMINus?
Sets or queries the AutoEthernet D+ source low threshold level for the specified bus. This threshold only applies when the AutoEthernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | AutoEthernet D+ source low threshold level for the specified bus. |
BUS:B1:AUTOETHERnet:LOWDATAPLUS 250.0E-3 BUS:B2:AUTOETHERnet:LOWDATAPLUS?
Sets or queries the AutoEthernet Data source low threshold level for the specified bus. This threshold applies only when the AutoEthernet signal type is differential.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| <NR3> | real | V | AutoEthernet DATA source low threshold level for the specified bus, in volts. |
BUS:B1:AUTOETHERnet:LOWTHRESHold -200e-3 BUS:B3:AUTOETHERnet:LOWTHRESHold? might return BUS:B3:AUTOETHERnet:LOWTHRESHOLD -500.0000E-3
Sets or queries the packet view for the decode on the specified bus. ON turns packet view on; OFF turns it off.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| state | enum | ON | OFF | Turns packet view on or off. |
BUS:B1:AUTOETHERnet:PACKetviewOFF BUS:B1:AUTOETHERnet:PACKetview?
Sets or queries the AutoEthernet signal type for the specified bus. The signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| signal type | enum | SINGLE | DIFF | Selects single-ended or differential signals. |
BUS:B4:AUTOETHERnet:SIGNALTYpe SINGLE BUS:B3:AUTOETHERnet:SIGNALTYpe?
Sets or queries the AutoEthernet source for the specified bus. The source may be an analog channel, math channel, or reference waveform used for differential input.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | AutoEthernet data source for the bus. |
BUS:B5:AUTOETHERnet:SOURCE CH4 BUS:B1:AUTOETHERnet:SOURCE?
Sets or queries the AutoEthernet D– source for the specified bus. It specifies the source channel used when the signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source used for the AutoEthernet D– signal. |
Sets or queries the AutoEthernet D+ source for the specified bus. It specifies the source channel to use when the signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source channel for the D+ signal. |
BUS:B2:AUTOETHERnet:SOUrce:DPLUs CH5 BUS:B1:AUTOETHERnet:SOUrce:DPLUs?
Sets or queries the AutoEthernet 10 Base-T1S math source threshold for the specified bus. The threshold is specified in volts.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | AutoEthernet D+ source threshold for the specified bus. |
Sets or queries the AutoEthernet Bus with speed 10 Base-T1S differential source threshold for the specified bus. It accepts a numeric threshold in volts.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | AutoEthernet source threshold for the specified bus. |
BUS:B3:AUTOETHERnet:TENBASET1S:THRESHold 250.0E-3 BUS:B2:AUTOETHERnet:TENBASET1S:THRESHold?
Sets or queries the AutoEthernet DATA source high threshold level for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | AutoEthernet source threshold for the specified bus, in volts. |
BUS:B3:AUTOETHERnet:THRESHold 250.0E-3 BUS:B2:AUTOETHERnet:THRESHold?
Sets or queries the AutoEthernet standard speed for the specified bus. The signal type is single ended and this command requires the SR-AUTOENET option.
BUS:B1:AUTOETHERnet:TYPE HUNDREDBASET1 specifies the AutoEthernet speed as 100Base-T1. BUS:B3:AUTOETHERnet:TYPE? might return BUS:B3:AUTOETHERnet:TYPE HUNDREDBASET1, indicating that the AutoEthernet speed is 100Base-T1 for Bus 3.
Sets or queries the CAN bit rate for the specified bus. If Custom is selected, use BUS:B<x>:CAN:BITRate:VALue to set the bit rate.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Bus number. |
| rate | enum | RATE10K | RATE100K | RATE1M | RATE125K | RATE153K | RATE20K | RATE25K | RATE250K | RATE31K | RATE33K | RATE400K | RATE50K | RATE500K | RATE62K | RATE68K | RATE800K | RATE83K | RATE92K | CUSTom | CAN bit rate setting. |
Sets or queries the CAN bit rate value for a bus when Custom is selected by BUS:B<x>:CAN:BITRate. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Bus number. |
| value | real | - | CAN bit rate value. |
BUS:B1:CAN:BITRate RATE1M sets the CAN bit rate to 1 Mb. BUS:B1:CAN:BITRate? might return BUS:B1:CAN:BITRATE RATE500K, indicating the CAN bit rate is set to 500 k.
Sets or queries the increased data phase bit rate used by CAN FD packets on the specified CAN bus. Use BUS:B<x>:CAN:FD:BITRate:CUSTom if you select Custom.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | RATE1M | RATE2M | RATE3M | RATE4M | RATE5M | RATE6M | RATE7M | RATE8M | RATE9M | RATE10M | RATE11M | RATE12M | RATE13M | RATE14M | RATE15M | RATE16M | CUSTom | Selects the CAN FD data phase bit rate. |
BUS:B1:CAN:FD:BITRate RATE1M BUS:B1:CAN:FD:BITRate?
Sets or queries the custom bit rate for the increased data phase of CAN FD packets on the specified CAN bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | real | - | Custom FD bit rate for the specified bus. |
BUS:B1:CAN:FD:BITRATE:CUSTOM 1000000 BUS:B1:CAN:FD:BITRATE:CUSTOM?
Sets or queries the sample point for the specified CAN bus. The bus is specified by x.
Sets or queries the signal type for the specified CAN bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | DIFFerential | CANH | CANL | RX | TX | Signal type to use for the specified CAN bus. |
Sets or queries the CAN source channel for the specified CAN bus. The bus number is specified by x.
Sets or queries which CAN standard specification to analyze the specified CAN bus with. The bus is specified by x.
BUS:B1:CAN:STANDARD FDISO sets the CAN standard to ISO CAN FD. BUS:B1:CAN:STANDARD? might return BUS:B1:CAN:STANDARD CAN2X, indicating that the CAN standard is CAN 2.0.
Sets or queries the source channel threshold for the specified CAN bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | V | The source channel threshold for the specified CAN bus. |
BUS:B1:CAN:THReshold 5 BUS:B1:CAN:THReshold?
Sets or queries the bit rate for the CAN XL bus specified by x. The valid range is 1000000 to 20000000, and the default is 4000000.
| Name | Type | Values | Description |
|---|---|---|---|
| bit rate | integer | 1000000 - 20000000 | Specifies the CAN XL data transfer bit rate. |
BUS:B1:CAN:XL:BITRate 1000000 BUS:B1:CAN:XL:BITRate?
Sets or queries the CAN XL custom bit rate for the specified bus. The valid range is 500000 to 20000000, with a default value of 4000000.
| Name | Type | Values | Description |
|---|---|---|---|
| value | integer | 500000 - 20000000 | CAN XL data transfer custom bit rate. |
BUS:B1:CAN:XL:BITRate:CUSTom 1000000 BUS:B1:CAN:XL:BITRate:CUSTom?
Sets or queries the CPHY differential AB source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the CPHY differential AB source as an analog/digital channel, math channel, or reference waveform. |
BUS:B1:CPHY:AB:SOUrce Ch1 sets the source to channel 1. BUS:B1:CPHY:AB:SOUrce? might return BUS:B1:CPHY:AB:SOUrce CH1, indicating the source is set to channel 1.
Sets or queries the CPHY Single Ended A source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 - +8 | The CPHY Single Ended A threshold in Volts for the specified bus. |
BUS:B4:CPHY:A:DATA:THRESHold 1.0 sets the Bus 4 CPHY threshold to 1.0 V. BUS:B3:CPHY:A:DATA:THRESHold? might return BUS:B3:CPHY:A:DATA:THRESHold 100.00000E-3, indicating the Bus 3 CPHY threshold is set to 100.0 mV.
Sets or queries the CPHY differential AB threshold for the specified bus. The bus is specified by x and the threshold range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Number of the bus. |
| threshold | real | -8 - +8 | CPHY differential AB threshold for the specified bus. |
BUS:B4:CPHY:AB:THReshold 1.0 BUS:B4:CPHY:AB:THReshold?
Sets or queries the CPHY AGND source for the specified bus. The source can be an analog/digital channel, a math channel, or a reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the CPHY AGND signal. |
BUS:B1:CPHY:AGND:SOUrce Ch1 BUS:B1:CPHY:AGND:SOUrce?
Sets or queries the CPHY differential AGND source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 - +8 | CPHY differential AGND threshold for the specified bus. |
BUS:B4:CPHY:AGND:THReshold 1.0 BUS:B4:CPHY:AGND:THReshold?
Sets or queries the CPHY Single Ended A LP threshold for the specified bus. The threshold argument is given in volts and must be within -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The CPHY Single Ended A LP threshold in volts for the specified bus. |
BUS:B4:CPHY:A:LP:THRESHold 1.0 BUS:B3:CPHY:A:LP:THRESHold?
Sets or queries the CPHY Single Ended A source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | Bus number B<x>. |
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the CPHY Single Ended A input. |
BUS:B1:CPHY:A:SOUrce Ch1 BUS:B1:CPHY:A:SOUrce? might return BUS:B1:CPHY:A:SOUrce CH1, indicating the source is set to channel 1.
Sets or queries the CPHY BC source for the specified bus. The source can be an analog/digital channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform to use for the bus. |
BUS:B1:CPHY:BC:SOUrce Ch1 BUS:B1:CPHY:BC:SOUrce? might return BUS:B1:CPHY:BC:SOUrce CH1, indicating the source is set to channel 1.
Sets or queries the CPHY differential BC source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 - +8 | CPHY differential BC threshold for the specified bus. |
BUS:B4:CPHY:BC:THReshold 1.0 BUS:B4:CPHY:BC:THReshold?
Sets or queries the CPHY Single Ended B threshold for the specified bus. The argument range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 - +8 | The CPHY Single Ended B threshold for the specified bus. |
BUS:B4:CPHY:B:DATA:THRESHold 1.0 BUS:B4:CPHY:B:DATA:THRESHold?
Sets the CPHY Single Ended B source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source used for the CPHY Single Ended B bus line. |
Sets or queries the bit rate for the specified CPHY bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 4 Mbps - 10 Gps | Specifies the bit rate. The default bit rate is 1 Gbps and the allowed range is 4 Mbps to 10 Gps. |
BUS:B1:CPHY:BITRate 8000000 BUS:B1:CPHY:BITRate?
Sets or queries the CPHY differential CA source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform to use for the CPHY differential CA source. |
BUS:B1:CPHY:CA:SOUrce Ch1 BUS:B1:CPHY:CA:SOUrce? might return BUS:B1:CPHY:CA:SOUrce CH1, indicating the source is set to channel 1.
Sets the CPHY differential CA source threshold for the specified bus. The bus number is specified by x.
Sets or queries the CPHY Single Ended C source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 - +8 | The CPHY Single Ended C threshold for the specified bus. |
BUS:B4:CPHY:C:DATA:THRESHold 1.0 BUS:B4:CPHY:C:DATA:THRESHold?
Sets or queries the CPHY differential CGND source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the CGND source for the specified bus line. |
Sets or queries the CPHY differential CGND source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
| threshold | real | -8 - +8 | The CPHY Single Ended C GND threshold for the specified bus. |
Sets the CPHY Single Ended C threshold for the specified bus. The argument range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 - +8 | The CPHY Single Ended C threshold for the specified bus. |
BUS:B4:CPHY:C:DATA:THRESHold 1.0 BUS:B4:CPHY:C:DATA:THRESHold? might return BUS:B4:CPHY:C:DATA:THRESHold 100.00000E-3
Sets or queries the CPHY Single Ended C source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| source | enum | CH<x> | MATH<x> | REF<x> | Selects an analog channel, math channel, or analog reference waveform as the source. |
BUS:B1:CPHY:C:SOUrce Ch1 sets the source to channel 1. BUS:B1:CPHY:C:SOUrce? might return BUS:B1:CPHY:C:SOUrce CH1, indicating the source is set to channel 1.
Sets the direction of the CPHY bus in low power for the specified bus. The default direction is forward.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| direction | enum | forward | reverse | Specifies the direction in low power. |
BUS:B1:CPHY:LP:DIRection reverse BUS:B2:CPHY:LP:DIRection?
Sets or queries the signal type for CPHY bus decode. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | The number of the bus. |
| signal type | enum | SINGLE | DIFF | Specifies the signal type to single ended or differential. |
BUS:B1:CPHY:SIGNALTYpe DIFF BUS:B2:CPHY:SIGNALTYpe?
Sets or queries the sub type for CPHY bus decode. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | CSI | DSI | Word | Symbol | Sub type for CPHY bus decode. |
Sets or queries the bit rate for the specified CXPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR1> | real | 1 bps - 20 kbps | Sets the CXPI Source bit rate for the specified bus. |
BUS:B1:CXPI:BITRate 100 sets the Bus 1 CXPI Source bit rate to 100 bps. BUS:B1:CXPI:BITRate? might return BUS:B1:CXPI:BITRate 100, indicating the Bus 1 CXPI Source bit rate is set to 100 bps.
Sets the CXPI source recessive threshold for the specified bus. The default value is 0 V and the valid range is -12 V to +12 V.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -12 - +12 | Recessive threshold voltage for the specified CXPI bus. |
BUS:B1:CXPI:REC:THReshold 1.0 BUS:B1:CXPI:REC:THReshold?
Sets or queries the source channel for the specified CXPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source channel for the specified CXPI bus. |
BUS:B1:CXPI:SOUrce Ch5 BUS:B1:CXPI:SOUrce? might return BUS:B1:CXPI:SOUrce Ch5, indicating the source is set to channel 5.
Sets or queries how the data is represented in the bus form for the specified bus. Different bus types support only a subset of the available formats.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HEX | BINARY | MIXEDASCII | MIXEDHEX | ASCII | DECIMAL | MIXED | Bus display format. |
Sets or queries what to display for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | BUS | BUSANDWAVEFORM | Selects whether to display only the bus form or the bus form together with the constituent source waveform(s). |
BUS:B1:DISplay:LAYout BUS specifies displaying the bus form only. BUS:B1:DISplay:LAYout? might return BUS:B1:DISPLAY:LAYOUT BUS, indicating the bus will be displayed without displaying its constituent source waveform(s).
Sets or queries the DPHY clock source for the specified bus line. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the source used for the DPHY clock. |
Sets or queries the DPHY clock source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8V - +8V | The DPHY clock high threshold for the specified bus. |
BUS:B4:DPHY:CLOCk:THRESHold 1.0 BUS:B3:DPHY:CLOCk:THRESHold?
Sets or queries the DPHY D- source data threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8V - +8V | The DPHY D- source data threshold for the specified bus. |
Sets or queries the DPHY D- source low power threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The DPHY D- source low power threshold for the specified bus. |
BUS:B3:DPHY:DMINus:LPTHRESHold -2.5 sets the Bus 3 DPHY D- source low power threshold to -2.5 V. BUS:B2:DPHY:DMINus:LPTHRESHold? might return BUS:B2:DPHY:DMINus:LPTHRESHold -1.2, indicating the Bus 1 DPHY D- source low power threshold is set to -1.2 V.
Sets or queries the DPHY D- source for the specified bus line. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects an analog channel, math channel, or reference waveform as the source. |
Sets or queries the D+ source data threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8V - +8V | The DPHY D+ source data threshold for the specified bus. |
BUS:B2:DPHY:DPlus:DATATHRESHold 100.00000E-3 BUS:B1:DPHY:DPlus:DATATHRESHold?
Sets or queries the DPHY D+ source low power threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8V - +8V | The DPHY D+ source low power threshold for the specified bus. |
BUS:B3:DPHY:DPlus:LPTHRESHold 1.2 BUS:B2:DPHY:DPlus:LPTHRESHold?
Sets or queries the DPHY D+ source for the specified bus line. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the DPHY D+ source as an analog channel, math channel, or reference waveform. |
BUS:B1:DPHY:DPlus:SOUrce Ch2 BUS:B1:DPHY:DPlus:SOUrce?
Sets or queries the DPHY bus direction in low power for the specified bus line. By default, the low-power direction is forward.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | forward | reverse | Specifies the DPHY bus direction in low power. |
BUS:B1:DPHY:LP:DIRection reverse BUS:B2:DPHY:LP:DIRection?
Sets or queries the protocol type for DPHY bus decode. The default type is CSI, and the bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| type | enum | CSI | DSI | Protocol type to set. |
BUS:B1:DPHY:PROTocol:TYPe DSI BUS:B2:DPHY:PROTocol:TYPe?
Sets or queries the 8b9b encoding for DPHY bus decode. By default, 8b9b encoding is false.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | false | true | Enables or disables 8b9b encoding. |
BUS:B1:DPHY:SIGnal:ENCoding true sets the Bus 1 DPHY 8b9b encoding to true. BUS:B2:DPHY:SIGnal:ENCoding? might return BUS:B2:DPHY:SIGnal:ENCoding true, indicating the Bus 2 DPHY 8b9b encoding is set to true.
Sets or queries the ESPI alert polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| polarity | enum | HIGH | LOW | Sets the ESPI alert polarity to active high or active low. |
BUS:B1:ESPI:ALERt:POLarity LOW BUS:B1:ESPI:ALERt:POLarity?
Sets or queries the alert source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies an analog channel, math channel, or reference waveform as the alert source. |
BUS:B1:ESPI:ALERt:SOUrce Ch5 BUS:B1:ESPI:ALERt:SOUrce? might return BUS:B1:ESPI:ALERt:SOUrce CH5
Sets or queries the ESPI alert view for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the alert source on or off. |
BUS:B1:ESPI:ALERTVIEW ON sets the Bus 1 alert view to on. BUS:B1:ESPI:ALERTVIEW? might return BUS:B1:ESPI:ALERTVIEW ON, indicating the Bus 1 alert view is on.
Sets or queries the alert source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | -8 - +8 | Alert threshold for the specified bus. |
BUS:B1:ESPI:ALERt:THReshold 1.0 BUS:B1:ESPI:ALERt:THReshold?
Sets or queries the ESPI chip select polarity for the specified bus. HIGH sets the chip select polarity active high; LOW sets it active low.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HIGH | LOW | Chip select polarity setting. |
BUS:B1:ESPI:CHIPSELect:POLarity LOW BUS:B1:ESPI:CHIPSELect:POLarity?
Sets or queries the chip select source for the specified ESPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects an analog channel, math channel, or reference waveform as the chip select source. |
BUS:B1:ESPI:CHIPSELect:SOUrce Ch5 sets the chip select source to channel 5. BUS:B1:ESPI:CHIPSELect:SOUrce? might return BUS:B1:ESPI:CHIPSELect:SOUrce Ch5, indicating the chip select source is set to channel 5.
Sets or queries the ESPI chip select threshold for the specified bus. The valid range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 V - +8 V | Chip select threshold for the specified bus. |
BUS:B1:ESPI:CHIPSELect:THReshold 1.0 BUS:B1:ESPI:CHIPSELect:THReshold?
Sets or queries the ESPI clock (SCLK) source polarity for the specified bus. Requires option SR-ESPI.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FALL | RISE | Sets the ESPI clock polarity to fall or rise. |
BUS:B1:ESPI:CLOCk:POLarity FALL BUS:B1:ESPI:CLOCk:POLarity?
Sets the ESPI clock source for the specified bus. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the clock source for the bus. |
BUS:B1:ESPI:CLOCk:SOUrce Ch5 BUS:B1:ESPI:CLOCk:SOUrce?
Sets or queries the Clock source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 - +8 | Clock threshold for the specified bus. |
BUS:B1:ESPI:CLOCk:THReshold 1.0 BUS:B1:ESPI:CLOCk:THReshold?
Sets or queries the ESPI data polarity for the specified bus. HIGH sets the data polarity to active high; LOW sets it to active low.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Sets the ESPI data polarity. |
BUS:B1:ESPI:DATAONE:POLarity LOW BUS:B1:ESPI:DATAONE:POLarity?
Sets or queries the command (single mode) / IO[0] (dual mode) data source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the data source as an analog channel, math channel, or reference waveform. |
BUS:B1:ESPI:DATAONE:SOUrce Ch5 BUS:B1:ESPI:DATAONE:SOUrce? might return BUS:B1:ESPI:DATAONE:SOUrce Ch5, indicating the data source is set to channel 5.
Sets or queries the ESPI Data One threshold for the specified bus. The valid range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | -8V - +8V | Sets the command/data threshold for the specified bus. |
BUS:B1:ESPI:DATAONE:THReshold 1.0 BUS:B1:ESPI:DATAONE:THReshold?
Sets or queries the ESPI response (single mode) / IO[1] (dual mode) polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Sets the ESPI data polarity to active high or active low. |
BUS:B1:ESPI:DATATWO:POLarity LOW BUS:B1:ESPI:DATATWO:POLarity?
Sets or queries the ESPI data source for the specified bus. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the data source as an analog channel, math channel, or reference waveform. |
BUS:B1:ESPI:DATATWO:SOUrce Ch5 BUS:B1:ESPI:DATATWO:SOUrce? might return BUS:B1:ESPI:DATATWO:SOUrce Ch5
Sets or queries the response (single mode) / IO[1] (dual mode) data source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 - +8 | Command/data threshold for the specified bus. |
BUS:B1:ESPI:DATATWO:THReshold 1.0 BUS:B1:ESPI:DATATWO:THReshold?
Sets or queries the I/O mode for the specified ESPI bus. Single mode displays the command and response decode in two lanes; dual mode displays the decode in a single data lane.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SINGle | DUAL | Selects the ESPI I/O display mode. |
BUS:B1:ESPI:IOMODe DUAL sets the Bus 1 mode to dual. BUS:B1:ESPI:IOMODe? might return BUS:B1:ESPI:IOMODe DUAL, indicating the Bus 1 mode is set to dual.
Sets or queries the DATA Minus source threshold for the specified EtherCAT bus. The valid range is -8 V to +8 V, with a default value of 0 V.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 V - +8 V | EtherCAT DataMinus source threshold for the specified bus. |
BUS:B1:ETHERCAT:DATAMINUSTHRESHold 1.0 BUS:B1:ETHERCAT:DATAMINUSTHRESHold?
Sets or queries the EtherCAT DataPlus source threshold for the specified bus. The valid range is -8 V to +8 V, and the default value is 0 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | 1 | The number of the bus. |
| threshold | real | -8 - +8 | EtherCAT DataPlus source threshold for the specified bus. |
BUS:B1:ETHERCAT:DATAPLUSTHRESHold 1.0 BUS:B1:ETHERCAT:DATAPLUSTHRESHold?
Sets or queries the EtherCAT signal type for the specified bus. Requires option SR-ETHERCAT.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SINGLE | DIFF | Specifies the signal type. |
BUS:B1:ETHERCAT:SIGNALTYpe SINGLE BUS:B1:ETHERCAT:SIGNALTYpe? might return BUS:B1:ETHERCAT:SIGNALTYpe SINGLE
Sets or queries the differential source for the specified EtherCAT bus. The source may be an analog channel, math waveform, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Differential source to use for the bus. |
BUS:B1:ETHERCAT:SouRce:DIFF CH4 BUS:B1:ETHERCAT:SOUrce:DIFF? might return BUS:B1:ETHERCAT:SOUrce:DIFF CH4
Sets or queries the DataMinus (SDATAMINUS) source for the specified EtherCAT bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the DataMinus source from an analog channel, math waveform, or reference waveform. |
BUS:B1:ETHERCAT:SOUrce:DMINus CH4 BUS:B1:ETHERCAT:SOUrce:DMINus?
Sets or queries the EtherCAT DataPlus source for the specified bus. The source can be one analog channel, math waveform, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | DataPlus source for the specified bus. |
BUS:B1:ETHERCAT:SOUrce:DPLUs CH4 BUS:B1:ETHERCAT:SOUrce:DPLUs?
Sets or queries the differential source threshold for the specified EtherCAT bus. The valid range is -8 V to +8 V, and the default value is 0 V.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8 - +8 | EtherCAT differential source threshold for the specified bus. |
BUS:B1:ETHERCAT:THRESHold 1.0 BUS:B1:ETHERCAT:THRESHold? might return BUS:B1:ETHERCAT:THRESHold 1.0, indicating the EtherCAT differential source threshold is set to 1.0 V.
Sets or queries the Ethernet D- source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | V | The Ethernet D- source threshold for the specified bus. |
BUS:B3:ETHERNET:DATAMINUSTHRESHOLD 250.0E-3 BUS:B2:ETHERNET:DATAMINUSTHRESHOLD?
Sets or queries the Ethernet D+ source threshold for the specified bus. This threshold only applies when the Ethernet signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | - | The Ethernet D+ source threshold for the specified bus. |
Sets or queries whether IPV4 packets are available for triggering on Ethernet for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
| state | enum | YES | NO | Specifies whether IPV4 packets are available for triggering. |
BUS:B1:ETHERNET:IPVFOUR NO BUS:B3:ETHERNET:IPVFOUR?
Sets or queries the Ethernet source low threshold for the specified bus. This threshold only applies when the Ethernet signal type is differential.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
Sets or queries whether Q-Tagging packets are available for triggering on Ethernet for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | YES | NO | Specifies whether Q-Tagging packets are available. |
BUS:B1:ETHERnet:QTAGGING YES BUS:B1:ETHERnet:QTAGGING?
Sets or queries the Ethernet signal type for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SINGLE | DIFF | Selects the Ethernet signal type. |
Sets or queries the Ethernet data (SDATA) source for the specified bus. The source channel is used when the signal type is differential.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the analog channel, math waveform, or reference waveform used as the Ethernet data source for differential input. |
BUS:B1:ETHERNET:SOURCE CH4 BUS:B1:ETHERNET:SOURCE?
Sets or queries the Ethernet D- source for the specified bus. This source channel is used when the signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for Ethernet D- input. |
Sets or queries the Ethernet D+ source for the specified bus. The source channel is used when the signal type is single ended.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform or channel to use for the Ethernet D+ source. |
BUS:B1:ETHERNET:SOUrce:DPLUs Ch5 sets the D+ source to channel 5. BUS:B1:ETHERNET:SOUrce:DPLUs? might return BUS:B1:ETHERNET:SOURCE:DPLUS CH5, indicating the D+ source is set to channel 5.
Sets or queries the Ethernet DATA source High threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Threshold value. |
Specifies the Ethernet standard speed for the selected bus. The bus number is given by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | TENBASET | HUNDREDBASETX | Selects the Ethernet speed as 10Base-T or 100Base-T. |
BUS:B1:ETHERNET:TYPE HUNDREDBASETX specifies the Ethernet speed as 100Base-T. BUS:B1:ETHERNET:TYPE? might return TENBASET, indicating that 10Base-T is the currently specified Ethernet speed.
Sets the eUSB bit rate for the specified bus. The selected rate applies to bus B<x> eUSB decode.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HIGH | FULL | LOW | Bit rate setting for the bus. |
BUS:B1:EUSB:BITRate HIGH sets the bit rate to 480 Mbps. BUS:B1:EUSB:BITRate? might return BUS:B1:EUSB:BITRate FULL, indicating the bit rate is set to 12 Mbps.
Sets or queries the eUSB D- Input Source Data Threshold for Data line decode for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The eUSB strobe threshold for the specified bus. |
BUS:B1:EUSB:DATAMINUS:DATA:THRESHold 1.0 sets the bus 1 eUSB threshold to 1.0 V. BUS:B1:EUSB:DATAMINUS:DATA:THRESHold? might return BUS:B1:EUSB:DATAMINUS:DATA:THRESHold -8.0, indicating the bus 1 eUSB threshold is set to -8.0 V.
Sets the eUSB DATA Minus source threshold for the specified bus. The allowed argument range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| NR3 | real | -8 V - +8 V | The eUSB DATA Minus source threshold. |
BUS:B1:EUSB:DATAMINUSTHRESHold 0.0 sets the bus 1 eUSB threshold to 0.0 V. BUS:B1:EUSB:DATAMINUSTHRESHold? might return BUS:B1:EUSB:DATAMINUSTHRESHold -8.0, indicating the bus 1 eUSB threshold is set to -8.0 V.
Sets or queries the eUSB D+ Input Source Data Threshold for Data line decode for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The eUSB Strobe threshold for the specified bus. |
BUS:B1:EUSB:DATAPLUS:DATA:THRESHold 1.0 sets the bus 1 eUSB threshold to 1.0 V. BUS:B1:EUSB:DATAPLUS:DATA:THRESHold? might return BUS:B1:EUSB:DATAPLUS:DATA:THRESHold -8.0, indicating the bus 1 eUSB threshold is set to -8.0 V.
Sets the eUSB data-plus threshold for the specified bus. The example shows the bus 1 threshold being set in volts, and the query returns the current threshold value with units.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The eUSB threshold for the specified bus. |
BUS:B1:EUSB:DATAPLUSTHRESHold 0.0 BUS:B1:EUSB:DATAPLUSTHRESHold?
Sets or queries the eUSB source Low threshold for the specified bus when signal type is Differential. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 - +8 | The eUSB Strobe threshold for the specified bus. |
BUS:B1:EUSB:LOWTHRESHold 1.0 BUS:B1:EUSB:LOWTHRESHold?
Sets or queries the eUSB operating mode for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NATive | REPEATERHOSt | REPEATERPERIPHERAL | Selects the eUSB operating mode for the bus. |
BUS:B1:EUSB:OPERating:MODe NATive sets the operating mode as native.
Sets or queries the eUSB signal type for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | SINGLE | DIFF | Selects the eUSB signal type for the bus. |
BUS:B1:EUSB:SIGNALTYpe SINGLE BUS:B1:EUSB:SIGNALTYpe? might return BUS:B1:EUSB:SIGNALTYpe SINGLE NATive, indicating the eUSB signal type is single for bus 1.
Sets or queries the eUSB Diff source for the specified bus when the signal type is Diff.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| source | enum | CH<x> | MATH<x> | REF<x> | Selects an analog channel, math waveform, or reference waveform as the source. |
BUS:B1:EUSB:SOUrce:DIFF Ch1 sets the channel to 1.
Sets or queries the eUSB DataMinus (SDATAMINUS) source for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the analog channel, math waveform, or reference waveform used as the source. |
BUS:B1:EUSB:SOUrce:DMINus Ch1 sets the channel to 1. BUS:B1:EUSB:SOUrce:DMINus? might return BUS:B1:EUSB:SOUrce:DMINus CH1, indicating channel 1 is the source.
Sets or queries the eUSB dataPlus source for the specified bus. Requires option SR-EUSB2.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the bus. |
Sets or queries the eUSB source High threshold for the specified bus when signal type is Diff.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | The eUSB Strobe threshold for the specified bus. |
BUS:B1:EUSB:THRESHold 1.0 BUS:B1:EUSB:THRESHold?
Sets or queries the FlexRay bus bit rate for the specified bus. If Custom is selected, use BUS:B<x>:FLEXray:BITRate:CUSTom to set the bit rate.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | CUSTOM | RATE2M | RATE5M | RATE10M | Selects the FlexRay bus bit rate. |
Sets or queries the FlexRay custom bit rate for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| NR1 | numeric | - | The FlexRay custom bit rate for the specified bus. |
BUS:B1:FLEXray:BITRate:CUSTom 10000000 BUS:B1:FLEXray:BITRate:CUSTom?
Sets or queries the FlexRay channel type for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | The bus number specified by x. |
| channel | enum | A | B | Selects the A or B channel. |
BUS:B1:FLEXRAY:CHANNEL B sets the FlexRay channel to B. BUS:B1:FLEXRAY:CHANNEL? might return BUS:B1:FLEXRAY:CHANNEL A, indicating the channel is set to A.
Sets or queries the FlexRay data source low threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | FlexRay data source low threshold for the specified bus. |
| bus | integer | - | Bus number x. |
BUS:B1:FLEXray:LOWTHRESHold 50.0e-3 BUS:B1:FLEXray:LOWTHRESHold?
Sets or queries the FlexRay signal type for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| signal type | enum | BDIFFBP | BM | TXRX | FlexRay signal type for the specified bus. |
BUS:B1:FLEXRAY:SIGNAL BM BUS:B1:FLEXRAY:SIGNAL?
Sets or queries the Flexray bus data source for the specified bus when the signal type is BDIFFBP or BM. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the specified bus. |
BUS:B1:FLEXRAY:SOUrce MATH4 BUS:B1:FLEXRAY:SOUrce?
Sets or queries the FlexRay TxRx data source for the specified bus when the signal type is TXRX. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the source waveform or channel for the TxRx data source. |
BUS:B1:FLEXRAY:SOUrce:TXRX CH1 BUS:B1:FLEXRAY:SOUrce:TXRX?
Sets or queries the FlexRay data source high threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | - | The FlexRay data source high threshold for the specified bus. |
BUS:B1:FLEXray:THRESHold 50.0-3 sets the high threshold to 50 mV. BUS:B1:FLEXray:THRESHold? might return BUS:B1:FLEXRAY:THRESHOLD 0.0E+0 indicating the high threshold is set to 0.0 V.
Sets or queries the FlexRay data source TxRx threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | - | The TxRx threshold. |
BUS:B1:FLEXray:TXRXTHRESHold 50.0e-3
Sets or queries the I2C clock (SCLK) source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | I2C SCLK source waveform for the specified bus. |
BUS:B1:I2C:CLOCK:SOURCE CH1 BUS:B1:I2C:CLOCK:SOURCE?
Sets or queries the I2C Clock (SCLK) source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | I2C Clock (SCLK) source threshold for the specified bus. |
Sets or queries the I2C data (SDA) source for the specified I2C bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | I2C SDA source for the specified bus. |
BUS:B1:I2C:DATA:SOURCE CH1 sets the I2C SDA source to channel 1. BUS:B1:I2C:DATA:SOURCE? might return BUS:B1:I2C:DATA:SOURCE MATH1 indicating that the I2C SDA source is set to math 1.
Sets or queries the I2C Data (SDA) source threshold for the specified bus. The bus is specified by x.
Sets or queries how seven-bit I2C addresses are represented in the bus display for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Selects the seven-bit address display format. |
Sets or queries the I3C version for the specified bus. VR10 selects Version 1.0, and VR11 selects Version 1.1; Version 1.0 is the default.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | VR10 | VR11 | Selects the I3C version to use for the specified bus. |
BUS:B1:I3C:VERSion VR11 sets the version to Version 1.1. BUS:B1:I3C:VERSion? might return BUS:B1:I3C:VERSion VR11 indicating that version 1.1 is selected for the decode.
Sets or queries the color of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | The bus label color. Send an empty string to return the color to the default color. |
BUS:B1:LABel:COLor "#FF0000" BUS:B1:LABel:COLor? might return BUS:B1:LABEL:COLOR "#FF0000" indicating the color is red.
Sets the bold font state for the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | 1 | 0 | Controls whether the label is displayed in bold font. |
BUS:B1:LABel:FONT:BOLD OFF turns off bold font. BUS:B1:LABel:FONT:BOLD? might return BUS:B1:LABEL:FONT:BOLD 1 indicating a bold font.
Sets or queries the italic state of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | 1 | 0 | Displays or does not display the label in italic font. |
BUS:B1LABel:FONT:ITALic OFF turns off italic font. BUS:B1LABel:FONT:ITALic? might return BUS:B1:LABEL:FONT:ITALIC 1 indicating the font is italic.
Sets the font size of the specified bus label. The bus is identified by x, and the size is given in points.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| size | integer | points | Font size in points. |
BUS:B1:LABel:FONT:SIZE 10 BUS:B1:LABel:FONT:SIZE? might return BUS:B1:LABEL:FONT:SIZE 20 indicating the font size is 20 points.
Sets or queries the font type of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| font type | string | - | Specified font type. |
BUS:B1:LABel:FONT:TYPE Monospace selects a monospace font. BUS:B1:LABel:FONT:TYPE? might return BUS:B1:LABEL:FONT:TYPE "Frutiger LT Std 55 Roman" indicating the font type is Frutiger LT Stdn.
Sets or queries the underline state of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | 1 | 0 | Underline state for the bus label. |
Sets or queries the label for the specified bus. The bus is specified by x, and the label text is a quoted alphanumeric string limited to 30 characters.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| name | string | - | Quoted alphanumeric label text for the bus, limited to 30 characters. |
BUS:B1:LABEL:NAME "TEST" BUS:B1:LABEL:NAME? might return BUS:B1:LABEL:NAME "BUS 1" indicating that the waveform label for the bus B1 is set to "Bus 1".
Sets or queries the x-position of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x-position | real | pixels | The x-position of the specified bus label, relative to the left edge of the screen. |
BUS:B1:LABel:XPOS 90 BUS:B1:LABel:XPOS? might return BUS:B1:LABEL:XPOS 45.0000
Sets or queries the y-position of the specified bus label. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| y-position | real | pixels | The y-position of the specified bus label, in pixels relative to the left edge of the screen. |
BUS:B1:LABel:YPOS 1.0e1 set the y position to 10.0. BUS:B1:LABel:YPOS? might return BUS:B1:LABEL:YPOS 0.0E+0 indicating the y position is 0.0 pixels from the baseline of the waveform.
Sets or queries the LIN bus bit rate for bus x. If Custom is selected, use BUS:B<x>:LIN:BITRate:CUSTom to set the bit rate.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | The number of the bus. |
| mode | enum | RATE10K | RATE1K | RATE19K | RATE2K | RATE4K | RATE9K | CUSTom | Selects the LIN bus bit rate. |
Sets or queries the LIN custom bit rate for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | The bus number. |
| rate | integer | - | The LIN custom bit rate for the specified bus. |
BUS:B1:LIN:BITRate:CUSTom 9000 sets the bit rate to 9,000. BUS:B1:LIN:BITRate:CUSTom? might return BUS:B1:LIN:BITRate:CUSTom 10000 indicating that the bit rate is set to 10,000.
Sets or queries the LIN bus identifier format for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | - | - | B<x> is the number of the bus. |
| format | enum | NOPARity | PARity | Selects whether the ID format includes parity or separates parity. |
Sets or queries the LIN source polarity for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| polarity | enum | INVerted | NORmal | Specifies inverted or normal polarity. |
Specifies the LIN sample point for the selected LIN bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | real | % | A percentage that represents the point at which to sample during each bit period. |
BUS:B1:LIN:SAMPLEPOINT 10 sets the sample point to 10% of the bit period.
Sets or queries the LIN data source for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the waveform source for the LIN bus. |
BUS:B1:LIN:SOUrce MATH4 BUS:B1:LIN:SOUrce? might return BUS:B1:LIN:SOURCE CH1, indicating the source is set to channel 1.
Sets or queries the LIN source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | The LIN source threshold for the specified bus. |
Sets or queries the LIN bus standard for the specified bus number x. The available standards are Mixed, version 1.x, or version 2.x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | Bus number x. |
| standard | enum | MIXed | V1X | V2X | LIN bus standard to select. |
BUS:B1:LIN:STANDard V1X BUS:B1:LIN:STANDard? might return BUS:B1:LIN:STANDARD V2X, indicating the standard is set to version 2.x for bus B1.
Sets or queries the Manchester bus bit order for the specified bus number x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LSB | MSB | Selects the Manchester bus bit order. |
Sets or queries the Manchester bus bit rate for bus x. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | 1 | The number of the bus. |
| bit rate | real | 1 Gbps | Sets the bit rate. |
BUS:B1:MANChester:BITRate 125000 sets the bit rate to 125 kb. BUS:B1:MANChester:BITRate? might return BUS:B1:MANChester:BITRATE 19000, indicating that the bit rate is set to 19 kb.
Sets or queries the Manchester bus Packet View display mode for the specified bus. BITS displays single-bit data, and PACKET displays field-based packet view.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | BITS | PACKET | Selects the Manchester Packet View display mode. |
BUS:B1:MANChester:DISplaymode PACKET BUS:B1:MANChester:DISplaymode? might return BUS:B1:MANChester:DISplaymode BITS, indicating the PacketView is on and the data can be seen in the form of fields.
Sets or queries the maximum response time to a valid command issued for the specified MIL-STD-1553 bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| value | real | s | The maximum response time. |
BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM 15.0E-6 BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM? might return BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM 12.000E-6, indicating a maximum response time of 12 microseconds.
Sets or queries the clock edge for the parallel bus specified by x. The bus can decode on the falling edge, rising edge, or either edge of the clock signal.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus. |
| edge | enum | FALLING | RISING | EITHER | Clock edge used for parallel-bus decoding. |
BUS:B1:PARALLEL:CLOCK:EDGE FALLING BUS:B1:PARALLEL:CLOCK:EDGE?
Determines whether the bus operates in a clocked or asynchronous fashion. The bus is specified by x.
Sets or queries the Parallel clock bit source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | NONE | Clock source for the specified parallel bus. |
BUS:B1:PARALLEL:CLOCKSOUrce CH3 BUS:B1:PARALLEL:CLOCKSOUrce?
Sets or queries the clock source threshold for the parallel bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | Clock source threshold for the parallel bus. |
Sets or queries the PCIe DATA Minus source threshold for the specified bus. Requires option SRPCIE321.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | –8.0 - 8.0 | The specified PCIe DATA Minus source threshold for the specified bus. |
BUS:B1:PCIE:DATAMinus:THRESHold:HIGh 250.0E-3 BUS:B1:PCIE:DATAMinus:THRESHold:HIGh?
Sets the PCIe Dplus threshold level for the specified bus. The example shows the value being set in volts and queried afterward.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | 250.0E-3 | The PCIe Dplus threshold level for the specified bus. |
BUS:B1:PCIE:DATAPlus:THRESHold:HIGh 250.0E-3 BUS:B1:PCIE:DATAPlus:THRESHold:HIGh?
Sets or queries the PCIe math source threshold for the specified bus. Requires option SRPCIE321.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | –8.0 - 8.0 | The specified PCIe math source threshold for the specified bus. |
BUS:B1:PCIE:MTHReshold 250.0E-3 BUS:B1:PCIE:MTHReshold?
Sets or queries the PCIe signal type for the specified bus. Requires option SRPCIE321.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | B<x> is the number of the bus. |
| signal type | enum | SINGLE | DIFF | Specifies the signal type for the PCIe bus as single or differential. |
BUS:B1:PCIE:SIGNALTYpe SINGLE sets the Signal Type for PCIE bus as single.
Sets or queries the PCIe DataMinus (SDATAMINUS) source for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform for the bus PCIe DataMinus signal. |
BUS:B1:PCIE:SOUrce:DMINus CH1 BUS:B1:PCIE:SOUrce:DMINus?
Sets or queries the PCIe dataPlus (SDATAPLUS) source for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source waveform for the PCIe dataPlus signal. |
BUS:B1:PCIE:SOUrce:DPLUs CH1 BUS:B1:PCIE:SOUrce:DPLUs?
Sets or queries the PSI5 bit period bus parameter. Requires option SR-PSI5.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | - | - | Bus number B<x>. |
| bit period | real | s | Specifies the bit period. |
BUS:B1:PSIFIVe:BITPERiod 0.000060 BUS:B1:PSIFIVe:BITPERiod?
Sets or queries the PSI5 bitrate for the selected bus. Requires option SR-PSI5.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | Bus number B<x>. |
| rate | enum | RATE125K | RATE189K | RATE83K | Sets the bit rate to 125 kb, 189 kb, or 83 kb. |
BUS:B1:PSIFIVe:BITRate RATE125k sets the bit rate to 125 kb.
Sets or queries the PSI5 bus communication direction. The default is Sensor to ECU.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
| mode | enum | SENSORECU | ECUSENSor | Specifies the communication direction. |
BUS:B1:PSIFIVe:COMM:DIRection SENSORECU BUS:B1:PSIFIVe:COMM:DIRection?
Sets or queries the PSI5 frame mandatory data region A. The dataA value is specified in bits, with a default of 10 bits and a range of 10 to 24 bits.
| Name | Type | Values | Description |
|---|---|---|---|
| dataA | integer | 10 - 24 | DataA value in bits. |
BUS:B1:PSIFIVe:DATAA 17 BUS:B1:PSIFIVe:DATAA?
Sets or queries the PSI5 frame optional bits of data region B. The value specifies the dataB value in bits.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
| dataB | integer | 0 - 12 | Specifies the dataB value in bits. |
BUS:B1:PSIFIVe:DATAB 7 BUS:B1:PSIFIVe:DATAB?
Sets or queries the data format in the PSI5 Frame2 packet.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NIBBLe | BYTe | Selects the PSI5 Frame2 data format. |
BUS:B1:PSIFIVe:DATAFORMat NIBBLe BUS:B1:PSIFIVe:DATAFORMat?
Sets or queries the PSI5 ECUSource for a bus. The source may be an analog channel, math waveform, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the source waveform. |
BUS:B1:PSIFIVe:ECUSOURce CH5 BUS:B1:PSIFIVe:ECUSOURce? might return :BUS:B1:PSIFIVe:ECUSOURce CH5, indicating the source is set to channel 5.
Sets or queries the PSI5 frame optional control bits. The frame control value is specified in bits and ranges from 0 to 4 bits, with a default of 0 bits.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | 0 | The number of the bus. |
| <NR1> | integer | 0 - 4 | Frame control value in bits. |
BUS:B1:PSIFIVe:FRAMECONTrol 2 sets the frame control as 2 bits. BUS:B1:PSIFIVe:FRAMECONTrol? might return :BUS:B1:PSIFIVe:FRAMECONTrol 3, indicating that the frame control is 3 bits.
Sets or queries the PSI5 messaging bits for the specified bus. OFF selects the default value 0; ON selects the value 2.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | Selects the messaging bits value. |
BUS:B1:PSIFIVe:MESSaging OFF BUS:B1:PSIFIVe:MESSaging?
Sets or queries the serial source for the PSI5 bus. The source can be an analog channel, math waveform, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the PSI5 bus. |
BUS:B1:PSIFIVe:SOUrce CH5 sets the source to channel 5. BUS:B1:PSIFIVe:SOUrce? might return :BUS:B1:PSIFIVe:SOUrce CH5, indicating the source is set to channel 5.
Sets or queries the optional status bits of PSI5.
Sets or queries the PSI5 Sync Mode for the specified bus. The mode can be Pulse Width or Tooth Gap.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | PULSEWIDTh | TOOTHGAP | PSI5 Sync Mode to select. |
BUS:B1:PSIFIVe:SYNCMODe PULSEWIDTh sets the Sync Mode to Pulse Width. BUS:B1:PSIFIVe:SYNCMODe? might return :BUS:B1:PSIFIVe:SYNCMODe TOOTHGAP, indicating that the Sync Mode is Tooth Gap.
Sets or queries the PSI5 threshold for the ECU To Sensor specified bus.
Sets or queries the PSI5 threshold for the Sensor To ECU specified bus. Requires option SR-PSI5.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| threshold | real | -8 V - +8 V | Specifies the PSI5 Strobe threshold for the specified bus. |
BUS:B1:PSIFIVe:THRESHold 1.0 BUS:B1:PSIFIVe:THRESHold?
Sets or queries the RS-232C bit order for bus x. LSB is the default value.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LSB | MSB | Selects the RS-232C bit order. |
BUS:B1:RS232C:BITORDer LSB BUS:B1:RS232C:BITORDer?
Sets or queries the RS-232C bit rate for bus<x>. If Custom is selected, the custom bit rate is set with BUS:B<x>:RS232C:BITRate:CUSTom.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | CUSTOM | RATE300 | RATE1K | RATE2K | RATE9K | RATE19K | RATE38K | RATE115K | RATE921K | Selects the RS-232C bit rate for the bus. |
BUS:B1:RS232C:BITRATE RATE9K BUS:B1:RS232C:BITRATE?
Sets or queries the RS-232C custom bit rate for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
| NR1 | real | - | The custom bit rate. |
BUS:B1:RS232C:BITRATE:CUSTOM 9500 BUS:B1:RS232C:BITRATE:CUSTOM?
Sets or queries the RS-232C data width for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | 7 | 8 | 9 | Number of bits in the RS-232C data frame. |
BUS:B1:RS232C:DATABITS 8 sets the data bits to 8 for the RS-232C bus B1.
Sets or queries the RS-232C string delimiter on bus <x>. This command applies only when Packet view is On and requires the SR-COMP option.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number specified by x. |
| delimiter | enum | NULl | CR | LF | SPace | XFF | Selects the packet delimiting value. |
BUS:B1:RS232C:DELIMITER LF BUS:B1:RS232C:DELIMITER?
Sets or queries the RS-232C display mode for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FRame | PACKET | RS-232C display mode for the specified bus. |
Sets or queries the RS-232C parity for bus <x>. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NONe | EVEN | ODD | Parity setting for the RS-232C bus. |
BUS:B1:RS232C:PARITY ODD BUS:B1:RS232C:PARITY?
Sets or queries the RS-232C source polarity for bus <x>, where the bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
Sets or queries the RS-232C source for bus <x>. The bus number is specified by x.
BUS:B1:RS232C:SOURCE CH1 BUS:B1:RS232C:SOURCE?
Sets or queries the RS-232C source threshold for the specified bus.
Sets or queries the 8B10b bit rate for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus. |
BUS:B1:S8B10B:BITRate 4000 sets the bit rate to 4 kb. BUS:B1:S8B10B:BITRate? might return BUS:B1:S8B10B:BITRATE 19000, which indicates that the bit rate is set to 19 kb.
Sets or queries the 8B10b source for the specified bus. This command specifies the source channel.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | 1 | The number of the bus. |
Sets or queries the 8B10b threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | -8 - +8 | The 8B10b Strobe threshold for the specified bus in volts. |
BUS:B4:S8B10B:THReshold 1.0 BUS:B3:S8B10B:THReshold?
Sets or queries the SDLC bit rate for the specified bus. The default bit rate is 10 kbs and the valid range is 300 to 1000000000.
| Name | Type | Values | Description |
|---|---|---|---|
| bit rate | real | 300 - 1000000000 | Bit rate for the SDLC bus. |
BUS:B1:SDLC:BITRate 80000 BUS:B1:SDLC:BITRate?
Sets or queries the source for the specified SDLC bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the bus. |
BUS:B1:SDLC:DATA:SOUrce Ch5 sets the source to channel 5. BUS:B1:SDLC:DATA:SOUrce? might return :BUS:B1:SDLC:DATA:SOUrce CH5, indicating the source is set to channel 5.
Sets or queries the SDLC data threshold for the specified bus. The valid range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | -8V - +8V | SDLC strobe threshold for the specified bus. |
BUS:B1:SDLC:DATA:THReshold 1.0 BUS:B1:SDLC:DATA:THReshold?
Sets or queries the SDLC bus encoding for the specified bus. Requires option SR-SDLC.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | DISCrete | INVert | Selects the SDLC encoding mechanism. |
BUS:B1:SDLC:ENCoding DISCrete BUS:B1:SDLC:ENCoding? might return :BUS:B1:SDLC:ENCoding DISCrete, indicating that the encoding type is Discrete Transmission.
Sets or queries the SDLC modulo for the specified bus waveform. The modulo determines the C-Field size in the SDLC frame.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus waveform number. |
| modulo | enum | 8 | 128 | C-Field size selection. |
BUS:B1:SDLC:MODulo 128 BUS:B1:SDLC:MODulo?
Sets or queries SENT fast channel bit widths for the specified bus.
BUS:B1:SENT:CHANWIDTH TWELVETWELVE sets the channel width of both Fast Channel 1 and Fast Channel 2 to twelve bits. BUS:B1:SENT:CHANWIDTH? might return BUS:B1:SENT:CHANWIDTH SIXTEENEIGHT, which indicates that the Fast Channel 1 width is 16 and the Fast Channel 2 width is eight.
Sets or queries SENT data nibbles for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
Sets or queries the SENT fast data channel count for the specified bus. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| channel count | enum | ONE | TWO | Specifies a SENT bus with one or two fast channels. |
BUS:B1:SENT:NUMCHANnel TWO sets the number of SENT channels to two. BUS:B1:SENT:NUMCHANNEL? might return BUS:B1:SENT:NUMCHANNEL ONE to indicate that the number of channels is set to one.
Sets or queries the SENT pause pulse for the specified bus. Requires option SRAUTOSEN.
Sets or queries the SENT Idle State signal polarity for the specified bus. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | INVerted | NORmal | Specifies the SENT idle state signal polarity. |
BUS:B1:SENT:POLARITY INVERTED BUS:B1:SENT:POLARITY?
Sets or queries the SENT slow channel configuration for the specified bus. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
Sets or queries the SENT DATA source for the specified bus. Requires the SRAUTOSEN option.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Specifies the waveform used as the SENT DATA source. |
BUS:B1:SENT:SOURCE CH1 sets channel 1 as the source for the SENT bus. BUS:B1:SENT:SOURCE? might return BUS:B1:SENT:SOURCE CH1 indicating that the source is set to channel 1.
Sets or queries the SENT bus data source threshold value for the specified bus waveform. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | V | Sets the data source threshold value in volts. |
BUS:B1:SENT:THRESHOLD 500.0E-3 sets the Bus 1 source threshold to 500.0 mV. BUS:B1:SENT:THRESHOLD? might return BUS:B1:SENT:THRESHOLD 2.5000 to indicate the Bus 1 source threshold is 2.5 V.
Queries the SENT bus source threshold value for the specified bus waveform. The value is reported in volts.
BUS:B1:SENT:THRESHOLD 500.0E-3 BUS:B1:SENT:THRESHOLD?
Sets or queries the SENT bus Clock Tick parameter for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| tick time | real | s | The SENT clock tick time. |
BUS:B1:SENT:TICKTIME 3.0E-6 sets the SENT bus to clock tick to 3 microseconds. BUS:B1:SENT:TICKTIME? might return BUS:B1:SENT:TICKTIME 10.0000E-6 to indicate the clock tick is set to 10 microseconds.
Sets or queries the SENT bus Clock Tick parameter for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| tick time | real | s | The SENT clock tick time. |
BUS:B1:SENT:TICKTIME 3.0E-6 BUS:B1:SENT:TICKTIME? might return BUS:B1:SENT:TICKTIME 10.0000E-6
Sets or queries the SENT bus Tick Tolerance percent parameter for the specified bus. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
Sets or queries the SENT bus Tick Tolerance percent parameter for the specified bus. Requires option SRAUTOSEN.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
Sets or queries the clock source for the specified bus. Requires option SR-SMBUS.
BUS:B1:SMBUS:CLOCk:SOUrce CH5 BUS:B1:SMBUS:CLOCk:SOUrce?
Sets or queries the clock source for the specified SMBUS bus. Requires option SR-SMBUS.
BUS:B1:SMBUS:CLOCk:SOUrce CH5 BUS:B1:SMBUS:CLOCk:SOUrce?
Sets or queries the SMBUS clock threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
| threshold | real | -8V - +8V | SMBUS clock threshold for the specified bus. |
BUS:B1:SMBUS:CLOCk:THReshold 1.0 BUS:B1:SMBUS:CLOCk:THReshold?
Queries the SMBUS clock threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus number. |
BUS:B1:SMBUS:CLOCk:THReshold? might return BUS:B1:SMBUS:CLOCk:THReshold 1.0, indicating the Bus 1 SMBUS clock threshold is 1.0 V.
Sets or queries the data source for the specified SMBUS bus. Requires option SR-SMBUS.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the data source as an analog channel, math channel, or reference waveform. |
BUS:B1:SMBUS:DATA:SOUrce CH5 BUS:B1:SMBUS:DATA:SOUrce?
Sets or queries the data source for the specified SMBUS bus. The source can be an analog channel, math channel, or reference waveform.
BUS:B1:SMBUS:DATA:SOUrce? might return BUS:B1:SMBUS:DATA:SOUrce CH5, indicating the Bus 1 data source is channel 5.
Sets or queries the SMBUS data threshold for the specified bus. The valid range is -8 V to +8 V.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
| threshold | real | -8V - +8V | SMBUS data threshold for the specified bus. |
BUS:B1:SMBUS:DATA:THReshold 1.0 BUS:B1:SMBUS:DATA:THReshold? might return BUS:B1:SMBUS:DATA:THReshold 1.0
Queries the SMBUS data threshold for the specified bus. The valid range is -8 V to +8 V.
BUS:B1:SMBUS:DATA:THReshold? might return BUS:B1:SMBUS:DATA:THReshold 1.0, indicating the Bus 1 SMBUS data threshold is 1.0 V.
Sets or queries the SMBus PEC selection for the specified bus. Requires option SR-SMBUS.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
| state | enum | TRUe | FALSe | SMBus PEC selection. |
BUS:B1:SMBUS:PEC:VALUe TRUe BUS:B1:SMBUS:PEC:VALUe?
Sets or queries the SMBus PEC selection for the specified bus. Requires option SR-SMBUS.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The bus number. |
| state | enum | TRUe | FALSe | Selects SMBus PEC as true or false. |
BUS:B1:SMBUS:PEC:VALUe TRUe BUS:B1:SMBUS:PEC:VALUe? might return BUS:B1:SMBUS:PEC:VALUe TRUe, indicating the PEC checkbox selection is true.
Sets or queries the SpaceWire bit rate for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
Sets or queries the SpaceWire bit rate for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | Bus number. |
| <NR3> | real | - | SpaceWire bit rate for the specified bus. |
Sets or queries the source of the SpaceWire Data signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source of the SpaceWire Data signal. |
BUS:B1:SPACEWIRe:DATa:SOUrce Ch5 BUS:B3:SPACEWIRe:DATa:SOUrce? might return BUS:B3:SPACEWIRe:DATa:SOUrce MATH2
Sets or queries the source of the SpaceWire Data signal for the specified bus. Requires option SR-SPACEWIRE.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the SpaceWire Data signal. |
BUS:B1:SPACEWIRe:DATa:SOUrce Ch5 sets the Bus 1 DATa source to channel 5. BUS:B3:SPACEWIRe:DATa:SOUrce? might return BUS:B3:SPACEWIRe:DATa:SOUrce MATH2, indicating the DATa source for Bus 3 is set to Math waveform 2.
Sets or queries the threshold of the SpaceWire Data signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
Sets or queries the threshold of the SpaceWire Data signal for the specified bus. Requires option SR-SPACEWIRE.
Sets or queries the decode type for SpaceWire bus decode. Requires option SR-SPACEWIRE.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | STRObe | DATARate | Specifies the SpaceWire decode type. |
BUS:B1:SPACEWIRe:DECode:TYPe STRobe BUS:B1:SPACEWIRe:DECode:TYPe?
Sets or queries the decode type for SpaceWire bus decode. Requires option SR-SPACEWIRE.
BUS:B1:SPACEWIRe:DECode:TYPe STRobe BUS:B1:SPACEWIRe:DECode:TYPe?
Sets or queries the source of the SpaceWire Strobe signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
Sets or queries the source of the SpaceWire Strobe signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
Sets or queries the threshold level of the SpaceWire Strobe signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | SpaceWire Strobe signal threshold level for the specified bus. |
BUS:B4:SPACEWIRe:STRobe:THReshold 1.2 BUS:B1:SPACEWIRe:STRobe:THReshold?
Sets or queries the threshold level of the SpaceWire Strobe signal for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus number. |
| threshold | real | V | SpaceWire Strobe signal threshold level for the specified bus. |
BUS:B4:SPACEWIRe:STRobe:THReshold 1.2 BUS:B1:SPACEWIRe:STRobe:THReshold?
Sets or queries sync for SpaceWire decoding.
Sets or queries sync for SpaceWire decoding.
Sets or queries the length of the SpaceWire sync data string in bytes. Requires the SR-SPACEWIRE option.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 2 - 10 | Length of the data string in bytes used for SpaceWire sync bytes. |
BUS:B1:SPACEWIRe:SYNC:COUnt 3 BUS:B1:SPACEWIRe:SYNC:COUnt?
Sets or queries the length of the data string in bytes used for SpaceWire sync bytes.
BUS:B1:SPACEWIRe:SYNC:COUnt 3 BUS:B1:SPACEWIRe:SYNC:COUnt? might return BUS:B1:SPACEWIRe:SYNC:COUnt 3, indicating the count is 3.
Sets or queries the SpaceWire sync pattern used for decoding.
Returns or sets the SpaceWire sync pattern for the specified bus.
BUS:B1:SPACEWIRe:SYNC:PATTern N N BUS:B1:SPACEWIRe:SYNC:PATTern?
Sets or queries the SpaceWire sync value for sync option data. Requires option SR-SPACEWIRE.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Sync value for sync option data. |
BUS:B1:SPACEWIRe:SYNC:VALUe D-00 D-00 BUS:B1:SPACEWIRe:SYNC:VALUe? might return BUS:B1:SPACEWIRe:SYNC:VALUe D-00 D-00, indicating the Bus 1 SpaceWire sync value is D-00 D-00.
Sets or queries the SpaceWire sync value for sync option data. Requires option SR-SPACEWIRE.
| Name | Type | Values | Description |
|---|---|---|---|
| value | string | - | Sync value for sync option data. |
BUS:B1:SPACEWIRe:SYNC:VALUe D-00 D-00 BUS:B1:SPACEWIRe:SYNC:VALUe?
Sets or queries the SPI bit order for the specified bus. The bus is specified by x.
Sets or queries the SPI bit order for the specified bus. The bus is specified by x.
Sets or queries the SPI clock (SCLK) source polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| polarity | enum | FALL | RISE | Sets the clock to the falling or rising edge of the signal. |
BUS:B1:SPI:CLOCK:POLARITY FALL BUS:B1:SPI:CLOCK:POLARITY?
Sets or queries the SPI clock (SCLK) source polarity for the specified bus. The bus is specified by x.
BUS:B1:SPI:CLOCK:POLARITY FALL BUS:B1:SPI:CLOCK:POLARITY?
Sets or queries the SPI clock (SCLK) source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
Sets or queries the SPI clock (SCLK) source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| b<x> | - | - | The number of the bus waveform. |
Sets or queries the SPI Clock (SCLK) source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | SPI Clock (SCLK) source threshold for the specified bus. |
BUS:B1:SPI:CLOCk:THReshold 50.0e-3 sets the threshold to 50.0 mV.
Sets or queries the SPI Clock (SCLK) source threshold for the specified bus. The bus is specified by x.
BUS:B1:SPI:CLOCk:THReshold 50.0e-3 sets the threshold to 50.0 mV.
Sets or queries the SPI data source polarity for the specified bus number. HIGH sets the polarity to active high and LOW sets it to active low.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HIGH | LOW | Sets the SPI data polarity state. |
BUS:B4:SPI:DATA:POLARITY HIGH BUS:B1:SPI:DATA:POLARITY?
Sets or queries the SPI Data source polarity for the specified bus number. HIGH sets active high and LOW sets active low.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | SPI data polarity setting. |
BUS:B4:SPI:DATA:POLARITY HIGH BUS:B1:SPI:DATA:POLARITY?
Sets or queries the number of bits per word for the specified SPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR1> | integer | 2 - 32 | Data size for the specified bus. |
BUS:B1:SPI:DATA:SIZE 7 BUS:B1:SPI:DATA:SIZE?
Sets or queries the number of bits per word for the specified SPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| data size | integer | 2 - 32 | The data size for the specified bus. |
BUS:B1:SPI:DATA:SIZE 7 sets the data size for SPI Bus 1 to seven bits per word. BUS:B1:SPI:DATA:SIZE? might return BUS:B1:SPI:DATA:SIZE 8, indicating that the data size for SPI Bus 1 is set to eight bits per word.
Sets or queries the SPI Data source for the specified bus number. The source may be an analog channel, digital channel, math waveform, reference waveform, or digital reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | SPI data source for the specified bus. |
BUS:B1:SPI:DATA:SOURCE CH2 BUS:B3:SPI:DATA:SOURCE?
Queries the SPI Data source for the specified bus number. The source can be an analog channel, digital channel, math waveform, reference waveform, or digital reference waveform.
BUS:B3:SPI:DATA:SOURCE? might return BUS:B3:SPI:DATA:SOURCE CH3, indicating that the SPI data source for the Bus 3 is set to channel 3.
Sets or queries the SPI Data (SDA) source threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | SPI Data (SDA) source threshold for the specified bus. |
BUS:B1:SPI:DATa:THReshold 50.0e-3
Sets or queries the SPI Data (Data) source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | V | The SPI Data (SDA) source threshold for the specified bus. |
BUS:B1:SPI:DATa:THReshold 50.0e-3
Sets or queries the SPI framing setting for the specified bus waveform. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | integer | - | The number of the bus waveform. |
| framing | enum | IDLE | SS | Selects the SPI framing mode. |
BUS:B1:SPI:FRAMING IDLE BUS:B1:SPI:FRAMING?
Sets or queries the SPI framing setting for the specified bus. The bus number is specified by x.
Sets or queries the SPI idle time for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| idle time | real | - | Specifies the SPI idle time. |
BUS:B1:SPI:IDLETime 0.000004 BUS:B1:SPI:IDLETime? might return BUS:B1:SPI:IDLETIME 5.0000E-6, indicating that the idle time is set to 5 μs.
Sets or queries the SPI idle time for the specified bus. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| idle time | real | - | Specifies the SPI idle time. |
BUS:B1:SPI:IDLETime 0.000004 BUS:B1:SPI:IDLETime?
Sets or queries the SPI MISo Data source polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Sets the polarity to high or low. |
BUS:B1:SPI:MISo:DATa:POLarity HIGH BUS:B1:SPI:MISo:DATa:POLarity? might return BUS:B1:SPI:MISo:DATa:POLarity HIGH, indicating that the SPI MISo data polarity is high.
Sets or queries the SPI MISO data source polarity for the specified bus waveform. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| polarity | enum | HIGH | LOW | Sets the polarity to high or low. |
BUS:B1:SPI:MISo:DATa:POLarity HIGH BUS:B1:SPI:MISo:DATa:POLarity? might return BUS:B1:SPI:MISo:DATa:POLarity HIGH, indicating that the SPI MISo data polarity is high.
Sets or queries the SPI MISo source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the waveform source for SPI MISo. |
BUS:B1:SPI:MISo:INPut Ch5 BUS:B1:SPI:MISo:INPut?
Sets or queries the SPI MISo source for the specified bus. The bus is specified by x.
Sets or queries the SPI MISo Data source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | The SPI MISo Data source threshold for the specified bus. |
BUS:B1:SPI:MISo:THReshold 1.0 BUS:B1:SPI:MISo:THReshold?
Sets or queries the SPI MISo Data source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | V | The SPI MISo Data source threshold for the specified bus. |
BUS:B1:SPI:MISo:THReshold 1.0 BUS:B1:SPI:MISo:THReshold?
Sets or queries the SPI MOSI source polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HIGH | LOW | Selects the SPI MOSI data polarity. |
BUS:B1:SPI:MOSi:DATa:POLarity HIGH BUS:B1:SPI:MOSi:DATa:POLarity?
Sets or queries the SPI MOSI source polarity for the specified bus. The bus is specified by x.
BUS:B1:SPI:MOSi:DATa:POLarity HIGH BUS:B1:SPI:MOSi:DATa:POLarity?
Sets or queries the SPI MOSI source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the analog channel, math waveform, or reference waveform used as the SPI MOSI source. |
BUS:B1:SPI:MOSi:INPut Ch5 sets the source to channel 5. BUS:B1:SPI:MOSi:INPut? might return :BUS:B1:SPI:MOSi:INPut HIGH, indicating the source is set to channel 5.
Queries the SPI MOSI source for the specified bus. The bus is specified by x.
BUS:B1:SPI:MOSi:INPut? might return :BUS:B1:SPI:MOSi:INPut HIGH, indicating the source is set to channel 5.
Sets or queries the SPI MOSI source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | V | SPI MOSI Data source threshold for the specified bus. |
BUS:B1:SPI:MOSi:THReshold 1.0 sets the Bus 1 SPI MOSI threshold to 1.0 V. BUS:B1:SPI:MOSi:THReshold? might return :BUS:B1:SPI:MOSi:THReshold 225.00000E-3, indicates the Bus 1 SPI MOSI threshold is set to 225.0 mV.
Sets or queries the SPI MOSI source threshold for the specified bus. The bus is specified by x.
Sets or queries the number of inputs for the specified SPI bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| inputs | enum | ONE | TWO | Number of data inputs to use. |
BUS:B1:SPI:NUMBer:INputs TWO BUS:B1:SPI:NUMBer:INputs?
Sets or queries the number of SPI data inputs for the specified bus waveform. The bus is specified by x.
Sets or queries the SPI Slave Select (SS) polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | LOW | HIGH | Sets the SPI Slave Select polarity. |
BUS:B1:SPI:SELECT:POLARITY HIGH sets the SPI Slave Select polarity for the bus B1 to active high.
Sets or queries the SPI Slave Select (SS) polarity for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | LOW | HIGH | Selects active low or active high polarity. |
BUS:B1:SPI:SELECT:POLARITY HIGH sets the SPI Slave Select polarity for the bus B1 to active high.
Sets or queries the SPI Slave Select (SS) source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the waveform used as the SPI Slave Select source for the bus. |
BUS:B1:SPI:SELECT:SOURCE MATH3 BUS:B1:SPI:SELECT:SOURCE?
Sets or queries the SPI Slave Select (SS) source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Specifies the SPI Slave Select source for the bus. |
BUS:B1:SPI:SELECT:SOURCE MATH3 BUS:B1:SPI:SELECT:SOURCE? might return :BUS:B1:SPI:SELECT:SOURCE CH3, indicating that the SPI Slave Select source for the bus B1 is set to channel 3.
Sets or queries the SPI Select (SS) source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | SPI Select (SS) source threshold for the specified bus. |
Sets or queries the SPI Select (SS) source threshold for the specified bus. The bus is specified by x.
Sets or queries the SPMI Clock (SCLK) source for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Specifies the clock source waveform for the specified SPMI bus. |
BUS:B1:SPMI:SCLk:SOUrce CH1 BUS:B1:SPMI:SCLk:SOUrce? might return BUS:B3:SPMI:SCLk:SOUrce CH3, indicating that the data source for bus B3 is set to channel 3.
Sets or queries the SPMI Clock (SCLK) source for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the waveform used as the SPMI clock source for the specified bus. |
BUS:B1:SPMI:SCLk:SOUrce CH1 BUS:B1:SPMI:SCLk:SOUrce?
Sets or queries the SPMI clock source threshold for the specified bus waveform. B<x> identifies the bus waveform number, and <NR3> is the clock source threshold value.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The bus waveform number. |
| threshold value | real | - | The clock (SCLK) source threshold value for the specified SPMI bus. |
BUS:B3:SPMI:SCLK:THRESHOLD 500.0E-3 BUS:B1:SPMI:SCLK:THRESHOLD?
Returns or sets the clock (SCLK) source threshold value for the specified SPMI bus. B<x> identifies the bus waveform.
BUS:B3:SPMI:SCLK:THRESHOLD 500.0E-3 BUS:B1:SPMI:SCLK:THRESHOLD?
Sets or queries the SPMI Data (SDATA) source for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the waveform source used as the SPMI data source for the specified bus. |
BUS:B4:SPMI:SDATa:SOUrce CH1 sets channel 1 as the data source for the SPMI bus 4. BUS:B1:SPMI:SDATa:SOUrce? might return :BUS:B1:SPMI:SDATa:SOUrce CH5 indicating that the data source is set to channel 5 for bus 1.
Sets or queries the SPMI Data (SDATA) source for the specified bus.
BUS:B1:SPMI:SDATa:SOUrce? might return :BUS:B1:SPMI:SDATa:SOUrce CH5 indicating that the data source is set to channel 5 for bus 1.
Sets or queries the SDATA source threshold value for the specified SPMI bus. Requires option SRPM.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | The data (SDATA) source threshold value for the specified SPMI bus. |
BUS:B2:SPMI:SDATa:THReshold 400.0E-3 BUS:B1:SPMI:SDATa:THReshold?
Returns the SDATA source threshold value for the specified SPMI bus. Requires option SRPM.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
BUS:B2:SPMI:SDATa:THReshold 400.0E-3 BUS:B1:SPMI:SDATa:THReshold?
Sets or queries the alert source channel for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Data source for the bus alert source. |
BUS:B1:SVID:ALERT:SOUrce CH5 BUS:B1:SVID:ALERT:SOUrce?
Sets or queries the alert source channel for the specified SVID bus. The bus is specified by x.
BUS:B1:SVID:ALERT:SOUrce? might return :BUS:B1:SVID:ALERT:SOUrce CH5, indicating the source is set to channel 5.
Sets or queries the alert threshold for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | -8 - +8 | The SVID Strobe threshold for the specified bus. |
BUS:B1:SVID:ALERT:THReshold 0.6 BUS:B1:SVID:ALERT:THReshold?
Sets or queries the alert threshold for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | -8 - +8 | The SVID Strobe threshold for the specified bus. |
BUS:B1:SVID:ALERT:THReshold 0.6 BUS:B1:SVID:ALERT:THReshold?
Sets or queries the clock source channel for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the analog channel, math channel, or reference waveform used as the clock source. |
BUS:B1:SVID:CLOCk:SOUrce CH3 BUS:B1:SVID:CLOCk:SOUrce?
Returns or sets the clock source channel for the specified SVID bus. The bus is specified by x.
BUS:B1:SVID:CLOCk:SOUrce CH3 BUS:B1:SVID:CLOCk:SOUrce?
Sets or queries the clock threshold for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | -8 - +8 | The SVID Strobe threshold for the specified bus. |
BUS:B1:SVID:CLOCk:THReshold 1.0 BUS:B1:SVID:CLOCk:THReshold?
Sets or queries the clock threshold for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | -8 V - +8 V | The SVID Strobe threshold for the specified bus. |
BUS:B1:SVID:CLOCk:THReshold 1.0 BUS:B1:SVID:CLOCk:THReshold?
Sets or queries the data source channel for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects an analog channel, math channel, or reference waveform as the SVID data source. |
BUS:B1:SVID:DATA:SOUrce CH4 BUS:B1:SVID:DATA:SOUrce? might return :BUS:B1:SVID:DATA:SOUrce CH4
Sets or queries the data source channel for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the data source channel for the SVID bus. |
BUS:B1:SVID:DATA:SOUrce CH4 BUS:B1:SVID:DATA:SOUrce? might return :BUS:B1:SVID:DATA:SOUrce CH4
Sets or queries the data threshold for the specified SVID bus waveform. The bus is identified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | -8 V - +8 V | The SVID Strobe threshold for the specified bus. |
BUS:B1:SVID:DATA:THReshold 0.25 BUS:B1:SVID:DATA:THReshold?
Sets or queries the data threshold for the specified SVID bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
BUS:B1:SVID:DATA:THReshold 0.25 BUS:B1:SVID:DATA:THReshold?
Sets or queries the bus type or standard for the specified bus waveform. Bus type arguments are available only when the required serial bus option is installed.
| Name | Type | Values | Description |
|---|---|---|---|
| bus type | enum | ARINC429 | AUDio | CAN | ETHernet | EUSB | FLEXRAY | I2C | I3C | LIN | MDIO | MIL1553B | PARallel | RS232C | SENT | SPI | SPMI | SVID | USB | Specifies the bus type or standard for bus x. |
Sets or queries the USB data rate for bus <x>, where the bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bus number | integer | 1 | The bus waveform number <x>. |
| rate | enum | FULL | HIGH | LOW | USB3O | USB31G1 | USB32G1 | USB31G2 | USB32G2 | USB4G2 | USB4G3 | USB bit rate to set for the selected bus. |
BUS:B1:USB:BITRATE FULL sets the bit rate to 12 Mbps.
Sets or queries the USB data rate for bus <x>. Requires option SR-USB.
| Name | Type | Values | Description |
|---|---|---|---|
| bus | - | - | Bus waveform number <x>. |
BUS:B1:USB:BITRATE FULL sets the bit rate to 12 Mbps.
Sets or queries the USB D- source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | The Minus threshold. |
BUS:B1:USB:DATAMINUSTHRESHold 50.0e-3 BUS:B1:USB:DATAMINUSTHRESHold?
Sets or queries the USB D- source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | Minus threshold. |
BUS:B1:USB:DATAMINUSTHRESHold 50.0e-3 BUS:B1:USB:DATAMINUSTHRESHold?
Sets or queries the USB D+ source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| threshold | real | - | The Plus threshold. |
BUS:B1:USB:DATAPLUSTHRESHold 50.0e-3 sets the threshold to 50.0 mV. BUS:B1:USB:DATAPLUSTHRESHold? might return :BUS:B1:USB:DATAPLUSTHRESHOLD 0.0E+0 indicating the threshold is set to 0.0 V.
Sets or queries the USB D+ source threshold for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | The Plus threshold. |
BUS:B1:USB:DATAPLUSTHRESHold 50.0e-3 BUS:B1:USB:DATAPLUSTHRESHold?
Sets or queries the USB bus packet view for the specified bus waveform. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| state | enum | ON | OFF | Turns the packet view for the decode on or off. |
BUS:B1:USB:DISplaymode OFF BUS:B1:USB:DISplaymode?
Sets or queries the USB bus packet view for the specified bus. The bus is identified by B<x>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the packet view on or off. |
BUS:B1:USB:DISplaymode OFF BUS:B1:USB:DISplaymode? might return BUS:B1:USB:DISplaymode OFF indicating that packet view is set to off.
Sets or queries the USB data (SDATA) of the Lane 1 source for the specified bus. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the data source for USB Lane 1. |
BUS:B1:USB:LANEONE:SOUrce CH1 sets the USB Lane 1 source to channel 1. BUS:B1:USB:LANEONE:SOUrce? might return BUS:B1:USB:LANEONE:SOUrce CH1, indicating that the USB Lane 1 source is channel 1.
Sets or queries the USB data (SDATA) Lane 1 source for the specified bus. The bus is specified by B<x>.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the data source for USB Lane 1. |
BUS:B1:USB:LANEONE:SOUrce CH1 sets the USB Lane 1 source to channel 1. BUS:B1:USB:LANEONE:SOUrce? might return BUS:B1:USB:LANEONE:SOUrce CH1, indicating that the USB Lane 1 source is channel 1.
Sets or queries the USB data (SDATA) lane 1 threshold for the specified bus. The valid range is -8.0 to 8.0.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8.0 - 8.0 | USB Lane 1 threshold level for the specified bus. |
BUS:B1:USB:LANEONE:THRESHold 250.0E-3 BUS:B1:USB:LANEONE:THRESHold?
Sets or queries the USB data (SDATA) Lane 1 threshold for the specified bus. The valid range is -8.0 to 8.0.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | -8.0 - 8.0 | USB Lane 1 threshold level for the specified bus. |
BUS:B1:USB:LANEONE:THRESHold 250.0E-3 BUS:B1:USB:LANEONE:THRESHold?
Sets or queries the number of lanes for the specified USB bus.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SINGLe | DUAL | Number of lanes to use for the specified bus. |
BUS:B1:USB:LANES DUAL BUS:B1:USB:LANES? might return BUS:B1:USB:LANES DUAL
Sets or queries the number of lanes for the specified USB bus.
BUS:B1:USB:LANES DUAL BUS:B1:USB:LANES?
Sets or queries the USB Lane 0 source for the specified bus. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the data source for the USB bus lane 0. |
BUS:B1:USB:LANEZERO:SOUrce CH1 BUS:B1:USB:LANEZERO:SOUrce?
Sets or queries the USB Lane 0 source for the specified bus. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Data source for the specified USB bus. |
BUS:B1:USB:LANEZERO:SOUrce CH1 BUS:B1:USB:LANEZERO:SOUrce?
Sets or queries the USB data (SDATA) Lane 0 threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | -8.0 - 8.0 | USB Lane 0 threshold level for the specified bus. |
BUS:B1:USB:LANEZERO:THRESHold 250.0E-3 BUS:B1:USB:LANEZERO:THRESHold?
Sets or queries the USB data (SDATA) Lane 0 threshold for the specified bus. Requires option SR-USB3, SR-USB2, or SR-USB1.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| <NR3> | real | -8.0 - 8.0 | Specifies the USB Lane 0 threshold level for the specified bus. |
BUS:B1:USB:LANEZERO:THRESHold 250.0E-3 BUS:B1:USB:LANEZERO:THRESHold?
Sets or queries the low threshold for the specified USB bus waveform. Requires option SR-USB2.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | - | The low threshold value. |
BUS:B1:USB:LOWTHRESHold 50.0e-3 BUS:B1:USB:LOWTHRESHold? might return BUS:B1:USB:LOWTHRESHOLD 0.0E+0
Returns the low threshold for the specified USB bus waveform. Requires option SR-USB2.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
BUS:B1:USB:LOWTHRESHold? might return BUS:B1:USB:LOWTHRESHOLD 0.0E+0 indicating that the threshold is set to 0.0 V.
Sets or queries the single ended source threshold for the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | - | - | The number of the bus waveform. |
| threshold | real | -8.0 - 8.0 | Specifies the single ended source threshold for the specified bus. |
BUS:B1:USB:SEMATHTHRESHold 250.0E-3 BUS:B1:USB:SEMATHTHRESHold?
Sets or queries the USB signal type for bus waveform B<x>. Use SINGLE for single-ended signals or DIFF for differential signals.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | Bus waveform number. |
| signal type | enum | SINGLE | DIFF | Selects single-ended or differential USB signals. |
BUS:B1:USB:SIGNALTyPE SINGLE BUS:B1:USB:SIGNALTYPE? might return :BUS:B1:USB:SIGNALTYPE DIFF, indicating the signal type is differential.
Queries the USB signal type for bus B<x>. The signal type can be single-ended or differential.
BUS:B1:USB:SIGNALTYpe SINGLE BUS:B1:USB:SIGNALTYpe? might return :BUS:B1:USB:SIGNALTYPE DIFF
Sets or queries the USB data source for bus <x> when the signal type is differential. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the USB data source for the bus. |
BUS:B1:USB:SOURCE D2 sets the USB data source for bus B1 to D2. BUS:B1:USB:SOURCE? might return :BUS:B1:USB:SOURCE D3, indicating that the USB data source for bus B1 is D3.
Sets or queries the USB data source when the signal type is differential for bus <x>. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | USB data source for the specified bus. |
BUS:B1:USB:SOURCE? might return :BUS:B1:USB:SOURCE D3, indicating that the USB data source for bus B1 is D3.
Sets or queries the USB D- (SDATAMINUS) source for bus <x> when the signal type is single ended. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the D- source for the specified USB bus. |
BUS:B1:USB:SOURCE:DMINUS CH2 sets the USB Data Source for D- input to channel 2. BUS:B1:USB:SOURCE:DMINUS? might return :BUS:B1:USB:SOURCE:DMINUS CH4, indicating that channel 4 is set to be the D- input for USB data.
Sets or queries the USB D- (SDATAMINUS) source for bus <x> when the signal type is single ended. The bus number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Source waveform for the specified USB bus D- input. |
BUS:B1:USB:SOURCE:DMINUS CH2 sets the USB Data Source for D- input to channel 2. BUS:B1:USB:SOURCE:DMINUS? might return :BUS:B1:USB:SOURCE:DMINUS CH4, indicating that channel 4 is set to be the D- input for USB data.
Sets or queries the USB dataPlus (SDATAPLUS) source for the specified bus when the signal type is single ended. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Selects the source waveform for USB D+ on bus <x>. |
Sets or queries the USB dataPlus (SDATAPLUS) source for the specified bus when the signal type is single ended. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | CH<x>_D<x> | MATH<x> | REF<x> | REF<x>_D<x> | Source used for the USB D+ signal for bus <x>. |
BUS:B1:USB:SOURCE:DPLUs CH2 BUS:B1:USB:SOURCE:DPLUs?
Sets or queries the USB DATA source high threshold for the specified bus when the signal source is differential. The bus is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| threshold | real | - | USB DATA source high threshold for the specified bus. |
BUS:B1:USB:THRESHold 50.0e-3 BUS:B1:USB:THRESHold?
Sets or queries the USB DATA source high threshold for the specified bus when the signal source is differential. The bus is specified by B<x>.
| Name | Type | Values | Description |
|---|---|---|---|
| B<x> | integer | - | The number of the bus waveform. |
| threshold | real | V | USB DATA source high threshold for the specified bus. |
BUS:B1:USB:THRESHold 50.0e-3 BUS:B1:USB:THRESHold?
Sets or queries the bus type or standard for the specified bus.
Sets or queries the USB bus type or standard for the specified bus.
Deletes the specified bus.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Specifies the bus to delete and is of the form "B<NR1>", where <NR1> is ≥1. |
BUS:DELETE B1 deletes bus B1.
Returns a comma-separated list of all currently defined buses.
BUS:LIST? might return BUS:LIST B1,B4 indicating the bus 1 and bus 4 are defined.
Sets the default bit delay for BUS B1 audio decoding. The factory default value is 1.
| Name | Type | Values | Description |
|---|---|---|---|
| bitdelay | integer | - | Bit delay setting for BUS B1 audio decoding. |
Sets the bit order for Bus B1 audio decoding. The factory default is MSB.
| Name | Type | Values | Description |
|---|---|---|---|
| bitorder | enum | MSB | Bit order used for audio decoding. |
Sets the audio channel size for bus B1 audio decoding. The factory default is 24.
| Name | Type | Values | Description |
|---|---|---|---|
| size | integer | - | Audio channel size. |
Factory default for the audio clock polarity setting. The default value is RISE.
Sets the source channel for the bus B1 audio clock signal. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Source channel for the bus B1 audio clock signal. |
Sets the default polarity for bus 1 audio data.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | NORMAL | Data polarity setting. |
Sets the audio data size for bus B1. The factory default is 24.
Sets the display format for bus B1 audio decoding. The factory default is SIGNEDDECIMAL.
Sets the audio frame size for bus B1. The factory default is 8.
| Name | Type | Values | Description |
|---|---|---|---|
| size | integer | 0 - 4294967295 | Audio frame size. |
Sets the polarity of the frame sync signal for audio bus decoding. Factory default is RISE.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | RISE | Polarity of the frame sync signal. |
Sets the source for the audio frame sync signal for bus B1. The factory default is CH2.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH2 | Frame sync source. |
Sets the audio bus type for bus B1. The factory default is I2S.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | I2S | Audio bus type. |
Sets the audio word select polarity for bus B1. The factory default is NORMAL.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | NORMAL | Audio word select polarity. |
Sets the source channel for the WORDSEL signal in Bus B1 audio decode settings.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH2 | Selects the source channel for WORDSEL. |
Sets the CAN bus bitrate for bus B1. This factory-default value is 500000.
Sets the CAN FD bit rate for bus B1. The factory default is 4000000.
| Name | Type | Values | Description |
|---|---|---|---|
| bitrate | integer | 4000000 | CAN FD bit rate in bits per second. |
Sets the CAN FD standard for bus B1. The factory default is ISO.
Sets the CAN probe selection for bus B1. The factory default is CANH.
Sets the CAN sample point for bus B1. The factory default is 50.
| Name | Type | Values | Description |
|---|---|---|---|
| samplepoint | integer | 0 - 100 | Sample point percentage for CAN decoding. |
Sets the source channel for bus B1 CAN decoding. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Source channel for CAN decoding. |
Sets the CAN standard for bus 1. The factory default is CAN2X.
| Name | Type | Values | Description |
|---|---|---|---|
| standard | enum | CAN2X | CAN standard selection. |
Sets the display format for bus B1. The factory default is HEXADECIMAL.
| Name | Type | Values | Description |
|---|---|---|---|
| format | enum | HEXADECIMAL | Display format setting. |
Sets the bus display type for bus B1. The factory default is BUS.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | BUS | Bus display type. |
Sets the FlexRay bus bitrate. The factory default is 10000000.
| Name | Type | Values | Description |
|---|---|---|---|
| bitrate | integer | Hz | FlexRay bus bitrate. |
Sets the FLEXRAY channel selection for bus B1. The factory default is A.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | enum | A | Selects the FLEXRAY channel. |
Sets the default FlexRay signal selection for bus B1. The factory default is BDIFFBP.
Sets the source channel for FlexRay bus B1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Source channel for the FlexRay bus. |
Sets whether the I2C address is included in read/write operations for bus B1. The factory default is 0.
Sets the source for the I2C clock signal on bus B1. The factory default is CH1.
Sets the source for the I2C data signal on bus B1. The factory default is CH2.
Sets the label for bus B1. The factory default is "Parallel".
Sets the LIN bus bit rate. The factory default is 19200.
Sets the LIN bus ID format for bus B1. The factory default is NOPARITY.
Sets the LIN bus polarity for bus B1. The factory default is NORMAL.
Sets the LIN sample point for bus B1. The factory default is 50.
Sets the source channel for LIN bus B1 decoding.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Source channel for the LIN bus. |
Sets the LIN standard for bus B1. The factory default is V2X.
| Name | Type | Values | Description |
|---|---|---|---|
| standard | enum | V2X | LIN standard selection. |
Sets the polarity for the MIL-STD-1553B bus decode in bus B1. The factory default is NORMAL.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | NORMAL | Polarity setting for the MIL-STD-1553B bus decode. |
Sets the MIL-STD-1553B response time maximum for bus B1. The factory default value shown is 12.0000E-6.
Sets the MIL-STD-1553B response time minimum for bus B1. The factory default is 4.0000E-6.
Sets the source channel for MIL-STD-1553B bus decoding on bus B1. The factory default is CH1.
Sets the source assigned to parallel bus bit 10. The factory default is D10.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | D10 | Source assigned to bit 10. |
Sets or shows the edge selection for the parallel bus clock in bus B1. The factory default is RISING.
Sets or returns whether the parallel bus clock is locked. Factory default is NO.
Sets the source for the parallel bus clock. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Clock source. |
Sets the parallel bus width for bus B1. The factory default is 16.
Sets the position of bus B1. The factory default is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Bus position value. |
Sets the RS232C bitrate for bus B1. The factory default is 9600.
| Name | Type | Values | Description |
|---|---|---|---|
| bitrate | integer | 1 | RS232C bitrate for bus B1. |
Sets the number of data bits for BUS:B1 RS232C bus decoding. The factory default is 8.
| Name | Type | Values | Description |
|---|---|---|---|
| databits | integer | 5 - 8 | Number of data bits. |
Sets the RS232C delimiter for bus B1. The factory default is LF.
Sets the RS232C display mode for bus B1. The factory default is FRAME.
Sets the RS232C parity setting for bus B1. The factory default is NONE.
| Name | Type | Values | Description |
|---|---|---|---|
| parity | enum | NONE | Parity mode for the RS232C bus. |
Sets the polarity used for the RS-232C bus decode on bus B1. The factory default is NORMAL.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | NORMAL | Polarity setting for RS-232C bus decode. |
Sets the RS232C receive source for bus B1. The factory default is OFF.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | OFF | RS232C receive source selection. |
Sets the source for the B1 RS232C transmit signal. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Transmit source. |
Sets the bit order used for SPI bus decoding on bus 1. Factory default is MSB.
| Name | Type | Values | Description |
|---|---|---|---|
| order | enum | MSB | Bit order for SPI decoding. |
Sets the SPI clock polarity for bus B1. The factory default is RISE.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | RISE | SPI clock polarity setting. |
Sets the source of the SPI clock for bus B1. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | Clock source. |
Sets the polarity for SPI input data on bus B1. Factory default is HIGH.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | HIGH | LOW | Polarity of the SPI data input signal. |
Sets the source for SPI input data on bus B1. The factory default is OFF.
Sets the SPI data output polarity for bus B1. The factory default is HIGH.
Sets the source channel for SPI bus B1 MOSI/MISO output data. The factory default is CH3.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH3 | Source channel for the SPI data output. |
Sets the SPI data size for bus B1. The factory default is 8.
| Name | Type | Values | Description |
|---|---|---|---|
| size | integer | 0 - 255 | SPI data size. |
Sets the SPI idle time for bus B1. The factory default is 5.0000E-6.
| Name | Type | Values | Description |
|---|---|---|---|
| idletime | real | s | SPI idle time. |
Sets the polarity of the SPI select signal for bus B1. The factory default is LOW.
Sets the source for SPI select. The factory default is CH2.
Sets or returns the state of bus 1. The factory default is 0.
Sets the bus type for bus B1. The factory default is PARALLEL.
Sets the USB bus bitrate mode for bus B1. The factory default is FULL.
Sets the USB probe mode for bus 1. The factory default is DIFFERENTIAL.
| Name | Type | Values | Description |
|---|---|---|---|
| probe | enum | DIFFERENTIAL | USB probe mode. |
Sets the USB differential source for bus B1. Factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | USB differential source. |
Sets the USB differential minus source for bus B1. The factory default is CH2.
Selects the source used for the USB D+ signal on bus B1. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | USB D+ source channel. |
Sets the lower threshold for the specified channel used by bus decoding. The factory default for CH1 is 0.0E+0.
Sets the lower threshold for the selected bus source. The factory default for BUS:LOWERTHRESHOLD:MATH is 0.0E+0.
Sets the lower threshold for the selected bus source reference. The factory default for :BUS:LOWERTHRESHOLD:REF1 is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| reference | real | - | Lower threshold value for REF1. |
Sets the upper threshold for the specified bus source channel. The factory default for CH1 is 800.0000E-3.
| Name | Type | Values | Description |
|---|---|---|---|
| CH1 | real | V | Upper threshold value for CH1. |
Sets the upper threshold for the specified source. The factory default for the MATH source is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH1 | CH2 | CH3 | CH4 | MATH | REF1 | REF2 | REF3 | Selects the source whose upper threshold is set. |
Sets the upper threshold for the selected bus source reference. The factory default for REF1 is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| ref | enum | REF1 | Reference bus source to which the upper threshold applies. |
Queries the cursor source for plot cursor A.
Queries the cursor source for plot cursor B.
Queries the delta V over delta T cursor readout value of the specified cursor in the specified view.
Sets or queries the cursor type of the specified cursor in the specified view.
Sets or queries the vertical cursor A position of the specified cursor in the specified view.
Queries cursor A vertical units of the specified cursor in the specified view.
Sets or queries the vertical cursor B position of the specified cursor in the specified view.
Queries the cursor B vertical units of the specified cursor in the specified view.
Queries the delta V cursor readout value of the specified cursor in the specified view.
Sets or queries the cursor tracking mode of the specified cursor in the specified view.
Queries the one over delta T cursor readout value of the specified cursor in the specified view.
Sets or queries the location to display the specified Reference FFT plot cursor readouts, either in the plot graticule or in a badge in the Results Bar.
| Name | Type | Values | Description |
|---|---|---|---|
| location | enum | - | Location to display the cursor readouts. |
Sets or queries the horizontal cursor A position of the specified cursor in the specified view.
Sets or queries the vertical cursor A position of the specified cursor in the specified view.
Sets or queries the horizontal cursor B position of the specified cursor in the specified view.
Sets or queries the vertical cursor B position in the specified Reference FFT view.
Sets or queries whether both cursors have same or different source.
Sets or queries the visible state of the cursor of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | Visible state of the cursor. |
Sets or queries the horizontal cursor A position of the specified cursor in the specified view.
Sets or returns the waveform cursor B position in the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Cursor B position in the specified plot view. |
Queries the delta T cursor readout value of the specified cursor in the specified view.
Queries cursor A vertical units of the specified cursor in the specified view.
Queries the value of the cursor A horizontal position.
Sets or returns the waveform cursor A position in the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Waveform cursor A position. |
Queries the value of the cursor A vertical position.
Queries the value of the cursor B horizontal position.
Sets or returns the waveform cursor B position in the specified plot view.
Queries the value of the cursor B vertical position.
Returns the noise density of the selected RF trace at the Cursor A position.
Sets or queries the Cursor A source in the Spectrum View.
Returns the noise density of the selected RF trace at the Cursor B position when in Absolute mode, or the phase noise when in Delta mode.
Sets or queries the Cursor B source in the Spectrum View.
Queries the horizontal bar Cursor A vertical position in the Spectrum View, where it crosses the spectrum signal.
Queries the horizontal bar Cursor A amplitude units in the Spectrum View.
Queries the horizontal bar Cursor B vertical position where it crosses the spectrum signal in the Spectrum View.
Queries the horizontal bar Cursor B amplitude units in the Spectrum View.
Sets or queries the Cursor B readout type in the Spectrum View.
Sets or queries whether both Spectrum View cursors have the same or different sources.
Sets or queries the visibility state of the cursors in the Spectrum View.
Sets or queries the Cursor A vertical position in the Spectrum View.
Sets or queries the Cursor B horizontal position in the Spectrum View.
Queries the cursor horizontal units in the Spectrum View.
Sets or queries the Cursor A vertical position in the Spectrum View.
Sets or queries the Cursor B vertical position in the Spectrum View.
Queries the cursor parameters for the specified cursor in the specified Waveform View.
Queries the cursor parameters for the specified Waveform View.
Sets or queries where Waveform View cursor readouts are displayed. The readouts can appear in the Waveform View graticule or in a badge in the Results Bar.
Sets or queries the cursor A source of the specified cursor in the specified Waveform View.
Sets or queries the cursor B source of the specified cursor in the specified Waveform View.
Returns the delta V over delta T cursor readout value of the specified cursor in the specified Waveform View.
Sets or queries the cursor mode of the specified cursor in the specified Waveform View. The mode can be SCREEN or DATA.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SCREEN | DATA | Cursor mode to set or query. |
Sets or queries the vertical cursor A position of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Vertical cursor A position. |
Queries the cursor A vertical units of the specified cursor in the specified Waveform View.
Sets or queries the vertical cursor B position of the specified cursor in the specified Waveform View.
Queries the cursor B vertical units of the specified cursor in the specified Waveform View.
Sets or queries the delta V cursor readout value over the history period.
Sets or queries the cursor tracking mode of the specified cursor in the specified Waveform View.
Returns the one over delta T cursor readout value of the specified cursor in the specified Waveform View.
Sets or queries the horizontal cursor A position of the specified cursor in the specified Waveform View.
Sets or queries the vertical cursor A position of the specified cursor in the specified Waveform View.
Sets or queries the horizontal cursor B position of the specified cursor in the specified Waveform View.
Sets or queries the vertical cursor B position of the specified cursor in the specified Waveform View.
Sets or queries the cursor source mode in the specified view.
Queries all values (Time, Voltage, Delta) associated with all the active sources in the Waveform View.
Queries the vertical waveform value at the cursor A position in the specified Waveform View.
Queries the vertical waveform value at the cursor B position in the specified Waveform View.
Sets or queries the visible state of the cursor of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | - | Visible state of the cursor. |
Sets or queries the horizontal cursor A position of the specified cursor in the specified Waveform View.
Sets or queries the horizontal cursor B position of the specified cursor in the specified Waveform View.
Queries the delta T cursor readout value of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 6 | Waveform View and cursor index. |
Queries cursor A vertical units of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Waveform View and cursor index placeholder. |
Sets or queries the horizontal cursor A position of the specified cursor in the specified Waveform View.
Sets or queries the horizontal cursor B position of the specified cursor in the specified Waveform View.
Sets or queries the vertical scale setting for applicable plots (Linear or Log) in the specified plot view.
Sets or queries the enabled state of auto-scale for plots.
Sets or returns the grid lines setting of the plot.
Sets or queries the state of the specified reference waveform in the specified Waveform View.
Sets or queries the x-axis scale setting for REFFFT.
Sets or queries the overall selected bus.
Sets or queries the overall selected reference waveform.
Sets or queries the overall selected source.
Sets or queries the spectrum trace source selected in the specified Spectrum View window.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | - | Source channel to select in the Spectrum View window. |
Sets or queries the selected view.
Sets or queries the selected source in the given waveview.
Sets or queries the vertical position of the specified channel in the specified Spectrum View.
Sets or queries the vertical scale of the specified channel in the specified Spectrum View.
Sets or queries the type of graticule that is displayed.
Sets or queries the horizontal display scaling of the Spectrum View window.
Sets or queries the graticule saturation level in the specified Spectrum View.
Sets or queries the waveform saturation level in the specified Spectrum View.
Sets or queries the waveform layout style used by the display.
Sets or queries the persistence decay time.
Globally enables or disables the waveform display.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the waveform display. |
Sets or queries the state of the specified channel in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the waveform view channel number. |
| state | enum | - | Controls whether the specified channel is displayed. |
Sets or queries the vertical position of the specified channel in the specified Waveform View in divisions.
Sets or queries the vertical scale of the specified channel in volts per division within the specified Waveform View.
Sets or queries the display state of the specified digital channel in the specified Waveform View.
Sets or queries the display state of the specified digital channels in the specified Waveform View.
Sets or queries the vertical position of the specified digital channel in the specified Waveform View in divisions.
Sets or queries the type of interpolation filter for the display.
Selects or queries the type of graticule that is displayed.
Sets or queries the graticule saturation level in the specified Waveform View.
Sets or queries the waveform saturation level in the specified Waveform View.
Sets or queries whether the specified math waveform gets auto-scaled when the math equation changes within the specified Waveform View.
Sets or queries whether the specified trend waveform gets auto-scaled when the waveform changes within the specified Waveform View.
Sets or queries the state of the specified trend waveform in the specified Waveform View.
Sets or queries the vertical position of the specified time trend in the specified Waveform View in divisions.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 8 | Specifies the Waveform View or plot index. |
Sets or queries the vertical scale of the specified time trend in the specified Waveform View in volts per division.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 4 | Specifies the PLOT<x> item within the selected Waveform View. |
Sets or queries the Waveform View graticule mode. The mode can be Fixed or Moveable.
Sets or queries the state of the specified bus in the specified Waveform View.
Sets or queries the vertical position of the specified bus in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 4 | Waveform View number. |
| b | integer | 1 - 8 | Bus number. |
Sets or queries the state of the specified reference waveform in the specified Waveform View.
Sets or queries the vertical position in divisions of the specified reference waveform.
Sets or queries the vertical scale of the specified reference waveform.
Sets or returns the selected frame of the specified digital ref.
Sets or queries the vertical position of the specified Frequency vs. Time trace in the Waveform View, in divisions.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 4 | Specifies the Waveform View trace number. |
Sets or queries the vertical scale of the specified Frequency vs. Time trace in the Waveform View. The scale is expressed in divisions.
Sets or queries the vertical position of the specified Magnitude vs. Time trace in the Waveform View, in divisions.
Sets or queries the vertical scale of the specified Magnitude vs. Time trace in the specified Waveform View. The scale is expressed in Volts, Watts, or dB per division.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 16 | Waveform View index. |
| x | integer | 1 - 16 | RF magnitude trace index. |
Sets or queries the vertical position of the specified Phase vs. Time trace in the Waveform View, in divisions.
Sets or queries the vertical scale of the specified Phase vs. Time trace in the specified Waveform View, in degrees per division.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Waveform View index. |
Sets or queries how waveforms are displayed for analysis mode.
Sets or queries the waveform layout style used by the display.
Sets or returns the selected frame of the specified analog ref.
Sets or queries the overall selected math.
Sets or queries the state of the specified math waveform in the specified waveform view.
Sets or queries the vertical position in divisions of the specified math waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | divisions | Vertical position of the specified math waveform. |
Sets or queries the vertical scale of the specified math waveform.
Sets or queries the start of the zoom x-axis in the specified plot view.
Sets or queries the end of the zoom x-axis in the specified plot view.
Sets or queries the start of the zoom y-axis in the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| xopt | integer | 1 - 16 | Specifies the plot view number. |
Sets or queries the end of the zoom y axis in the specified plot view.
Sets or returns the left edge of the zoom x-axis in the specified plot view.
Sets or queries the right edge of the zoom x-axis in the specified plot view.
Sets or queries the left edge of the zoom x-axis in the specified plot view.
Sets or queries the end of the zoom y-axis in the specified plot view.
Sets or queries the horizontal zoom position of the specified zoom in the specified Waveform View. The zoom waveform displays around this position.
Sets or queries the zoom horizontal scale factor, of the specified zoom in the specified Waveform View, in which the zoom waveform is displayed.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the Waveform View number. |
| x | integer | - | Specifies the zoom number in the Waveform View. |
Sets or queries the zoom window horizontal scale in the specified Waveform View.
Sets or queries the specified zoom in the specified Waveform View on or off.
Sets or queries the vertical position of the specified zoom in the specified Waveform View, in which the zoom waveform is displayed.
Sets or queries the zoom vertical scale factor of the specified waveform for the specified zoom in the specified Waveform View.
Queries the zoom parameters of the specified zoom in the specified Waveform View.
Queries the zoom parameters of the specified Waveform View.
Sets or queries the Inverted mode color of the specified channel, math waveform, or reference waveform. One of 48 unique colors can be assigned and remains in effect until reset.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | discrete | - | Specifies the input channel for which the waveform color is changed. |
| math | discrete | - | Specifies the math waveform for which the waveform color is changed. |
| reference | discrete | - | Specifies the reference waveform for which the waveform color is changed. |
| color | integer | 0 - 47 | Color index to assign to the specified waveform. |
DISplay:CH1:INVERTColor COLOR23 DISplay:REF3:INVERTColor?
Returns the current Display settings.
Sets or queries the color mode for the graticule and waveform display.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NORMal | INVERTed | Color mode for the graticule and waveform display. |
DISPLAY:COLORS NORMAL DISPLAY:COLORS? might return DISPLAY:COLORS INVERTED indicating the display colors are inverted.
Sets or queries the global state of the specified bus in the waveform view. True/On turns the source on; false/Off turns it off. The command only works if the specified bus is already added.
| Name | Type | Values | Description |
|---|---|---|---|
| state | boolean | - | Global display state of the specified bus. |
Sets or queries the normal mode color of the specified channel, math waveform, or reference waveform. One of 48 unique colors can be assigned and remains in effect until the colors are reset.
| Name | Type | Values | Description |
|---|---|---|---|
| source | discrete | - | Specifies the input channel, math waveform, or reference waveform to change. |
| COLOR<x> | integer | 0 - 47 | Specifies the color to assign to the selected waveform. |
DISplay:CH1:NORMALColor COLOR13 sets the channel 1 inverted waveform color to the value 23. DISplay:REF3:NORMALColor? might return COLOR2, indicating that the inverted waveform color setting for reference waveform 3 is 2.
Sets or queries the global display state of the specified channel. Setting it true turns on the source in the waveform view; setting it false turns it off. This command works only if the specified channel is already added.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | NR1 | OFF | ON | Global display state for the specified channel. |
DISplay:GLObal:CH1:STATE OFF turns off the display of channel 1. DISplay:GLObal:CH1:STATE? might return DISPLAY:GLOBAL:CH1:STATE 0 indicating that channel 1 is not displayed.
Sets or queries the global display state of the specified math waveform. True (On or nonzero) turns the source on in the waveform view; false (Off or 0) turns it off. This command only works if the specified math waveform is already added.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | NR1 | OFF | ON | Display state to set for the specified math waveform. |
Sets or queries the global display mode of the specified time trend plot. Turning it on displays the plot in the waveform view; turning it off hides it.
| Name | Type | Values | Description |
|---|---|---|---|
| plot<x> | integer | - | Plot number. |
| stateopt | enum | NR1 | OFF | ON | Display state; <NR1> = 0 disables display, any other value enables display. ON enables display and OFF disables display. |
DISplay:GLObal:PLOT1:STATE ON DISplay:GLObal:PLOT1:STATE? might return :DISPLAY:GLOBAL:PLOT1:STATE1 indicating plot 1 is displayed.
Sets or queries the global display state of the specified reference waveform. This command only works if the specified reference waveform is already added.
| Name | Type | Values | Description |
|---|---|---|---|
| ref<x> | integer | - | The reference waveform number. |
| state | enum | NR1 | OFF | ON | Turns display on or off, or accepts a numeric value where 0 disables display and any other value enables it. |
Sets or queries the display backlight intensity setting.
| Name | Type | Values | Description |
|---|---|---|---|
| level | enum | LOW | MEDium | HIGH | Selects the backlight brightness level. |
DISPLAY:INTENSITY:BACKLIGHT LOW DISPLAY:INTENSITY:BACKLIGHT?
Sets or queries the state of the display auto-dim feature. By default it is enabled. Once the backlight has dimmed, any button push, knob turn or mouse movement returns the backlight value to the value set by :DISplay:INTENSITy:BACKLight.
This query-only command returns the waveform saturation level and screen saver settings.
Sets or queries the amount of time, in minutes, to wait for no user interface activity before automatically dimming the display. The time can range from 10 to 1440 minutes, with a default of 10 minutes.
| Name | Type | Values | Description |
|---|---|---|---|
| time | integer | 10 - 1440 | Amount of time to wait before automatically dimming the display. |
DISPLAY:INTENSITY:BACKLIGHT:AUTODIM:TIME 30 DISPLAY:INTENSITY:BACKLIGHT:AUTODIM:TIME?
Sets or returns the enabled state of autoscale for Math/FFT waveforms.
Queries the Math-FFT waveform view source for cursor A.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
DISplay:MATHFFTView1:CURSor:ASOUrce? might return DISPLAY:MATHFFTVIEW1:CURSOR:ASOURCE MATH1, indicating the source is MATH 1.
Queries the Math-FFT waveform view source for cursor B.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 6 | Math-FFT waveform number. |
DISplay:MATHFFTView5:CURSor:BSOUrce? might return :DISPLAY:MATHFFTVIEW5:CURSOR:BSOURCE MATH5, indicating that the source is Math waveform MATH 5.
Returns the ΔY/ΔX cursor readout value for the specified Math-FFT view. The command may time out if the current cursor is set to horizontal mode.
DISplay:MATHFFTView<x>:CURSor:DDT? might return :DISPLAY:MATHFFTVIEW1:CURSOR:DDT 14.0056E-9,
Sets or queries the cursor type for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| function | enum | WAVEform | VBArs | HBArs | SCREEN | Cursor type to display for the specified Math-FFT view. |
DISplay:MATHFFTView5:CURSor:FUNCtion HBARS DISplay:MATHFFTView1:CURSor:FUNCtion?
Sets or queries the cursor type for the specified Math-FFT view.
DISplay:MATHFFTView5:CURSor:FUNCtion HBARS DISplay:MATHFFTView1:CURSor:FUNCtion?
Sets or returns the position of horizontal cursor A for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Position value for horizontal cursor A. |
Queries the position of horizontal cursor A for the specified Math-FFT view.
DISplay:MATHFFTView4:CURSor:HBArs:APOSition? might return :DISPLAY:MATHFFTVIEW4:CURSOR:HBARS:APOSITION -274.2247E-3, indicating the A cursor position is –274.2247E-3.
Queries the vertical units of horizontal cursor A for the specified Math-FFT view.
Sets or returns the position of horizontal cursor B for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | - | Vertical cursor B position for the specified Math-FFT view. |
DISplay:MATHFFTView1:CURSor:HBArs:BPOSition 50e-3 sets the position to 0.05 vertical units. DISplay:MATHFFTView1:CURSor:HBArs:BPOSition? might return DISPLAY:MATHFFTVIEW1:CURSOR:HBARS:BPOSITION -40.4061, indicating the position is –40.4061 vertical units.
Queries the vertical units of horizontal cursor B for the specified Math-FFT view.
Queries the horizontal cursor delta value for the specified Math-FFT view.
Sets or queries the cursor mode for the specified Math-FFT view. The example shows the mode can be set to INDEPENDENT and queried back.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Math-FFT view number. |
DISplay:MATHFFTView1:CURSor:MODe INDEPENDENT allows independent adjustment of the two cursors. DISplay:MATHFFTView1:CURSor:MODe? might return :DISPLAY:MATHFFTVIEW1:CURSOR:MODE INDEPENDENT, indicating the mode is set to independent.
Queries the cursor mode of the specified Math-FFT view. The return indicates the current mode setting, such as INDEPENDENT.
DISplay:MATHFFTView1:CURSor:MODe INDEPENDENT allows independent adjustment of the two cursors. DISplay:MATHFFTView1:CURSor:MODe? might return :DISPLAY:MATHFFTVIEW1:CURSOR:MODE INDEPENDENT, indicating the mode is set to independent.
Queries the one over delta cursor readout value of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
DISplay:MATHFFTView1:CURSor:ONEOVERDELTATVALUE? might return :DISPLAY:MATHFFTVIEW1:CURSOR:ONEOVERDELTATVALUE 2.6005E-9, indicating the one over delta time value is 2.6005 nanoseconds.
Sets or queries the location used to display the specified Math FFT plot cursor readouts. Readouts can be shown in the plot graticule or as a badge in the Results Bar.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT plot number. |
| location | enum | GRATICULE | BADGE | Location where Math FFT plot cursor readouts are displayed. |
DISplay:MATHFFTView4:CURSor:ROLOCATION GRATICULE DISplay:MATHFFTView2:CURSor:ROLOCATION?
Sets or queries the location used to display Math-FFT plot cursor readouts, either in the plot graticule or as a badge in the Results Bar.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Math-FFT plot number. |
| location | enum | GRATICULE | BADGE | Selects where the Math FFT plot cursor readouts are displayed. |
Sets or returns the vertical cursor A x-axis waveform measurement position of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | MHz | Cursor position. |
DISPLAY:MATHFFTVIEW1:CURSOR:SCREEN:AXPOSITION 700.000E+6 DISPLAY:MATHFFTVIEW3:CURSOR:SCREEN:AXPOSITION?
Sets or returns the vertical cursor A x-axis waveform measurement position of the specified Math-FFT view.
DISPLAY:MATHFFTVIEW1:CURSOR:SCREEN:AXPOSITION 700.000E+6 DISPLAY:MATHFFTVIEW3:CURSOR:SCREEN:AXPOSITION?
Sets or returns the vertical cursor A y-axis amplitude measurement value of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The cursor A position of the specified cursor in the specified view. |
DISplay:MATHFFTView2:CURSor:SCREEN:AYPOSition 1.0e0 DISplay:MATHFFTView5:CURSor:SCREEN:AYPOSition?
Sets or returns the vertical cursor A y-axis amplitude measurement value of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
DISplay:MATHFFTView2:CURSor:SCREEN:AYPOSition 1.0e0 DISplay:MATHFFTView5:CURSor:SCREEN:AYPOSition?
Sets the vertical cursor B x-axis waveform measurement position of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | Math-FFT waveform number. |
| <NR3> | real | MHz | Cursor position. |
Queries the horizontal cursor B position for the specified Math-FFT view. The response returns the cursor position as an NR3 numeric value.
DISplay:MATHFFTView1:CURSor:SCREEN:BXPOSition? might return :DISPLAY:MATHFFTVIEW1:CURSOR:SCREEN:BXPOSITION 2.50E+9, indicating the cursor position is 2.5 GHz.
Sets or returns the vertical cursor B y-axis amplitude measurement value of the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | - | Vertical cursor B position of the specified cursor in the specified view. |
DISplay:MATHFFTView1:CURSor:SCREEN:BYPOSition -50.0e0 DISplay:MATHFFTView4:CURSor:SCREEN:BYPOSition?
Queries the vertical cursor B y-axis amplitude measurement value for the specified Math-FFT view.
DISplay:MATHFFTView1:CURSor:SCREEN:BYPOSition? might return :DISPLAY:MATHFFTVIEW4:CURSOR:SCREEN:BYPOSITION -59.0460929065173, indicating the cursor position is at -59.0 dBm.
Sets or queries the visible state of cursors for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | 0 | 1 | Enables or disables the cursors for the specified Math-FFT view. |
Queries the state of the cursors for the specified Math-FFT view.
DISplay:MATHFFTView1:CURSor:STATE? might return :DISPLAY:MATHFFTVIEW1:CURSOR:STATE 1, indicating the cursors are enabled.
Sets or queries the horizontal cursor A position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | - | Vertical cursor A position in the specified view. |
DISplay:MATHFFTView1:CURSor:VBArs:APOSition 500.0e6 sets the cursor A position to 500 MHz. DISplay:MATHFFTView1:CURSor:VBArs:APOSition? might return :DISPLAY:MATHFFTVIEW1:CURSOR:VBARS:APOSITION 585.533869115958E+6, indicating cursor position is 585.5 MHz.
Sets or queries the horizontal cursor A position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| value | real | - | Sets the cursor A position in the specified view. |
DISplay:MATHFFTView1:CURSor:VBArs:APOSition 500.0e6 sets the cursor A position to 500 MHz. DISplay:MATHFFTView1:CURSor:VBArs:APOSition? might return :DISPLAY:MATHFFTVIEW1:CURSOR:VBARS:APOSITION 585.533869115958E+6, indicating cursor position is 585.5 MHz.
Queries the vertical cursor A measurement units for the specified Math-FFT view.
DISplay:MATHFFTView1:CURSor:VBArs:AUNIts? might return :DISPLAY:MATHFFTVIEW1:CURSOR:VBARS:UNITS"dBm", indicating the cursor units are dBm.
Sets or queries the vertical cursor B position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | - | Vertical cursor B position in the specified view. |
Sets or queries the vertical cursor B position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| position | real | - | Vertical cursor B position in the specified view. |
DISplay:MATHFFTView1:CURSor:VBArs:BPOSition 2.0e9 DISplay:MATHFFTView1:CURSor:VBArs:BPOSition?
Queries the vertical cursor B measurement units for the specified Math-FFT view.
Queries the vertical cursor’s delta T readout value for the specified Math-FFT view.
DISplay:MATHFFTView1:CURSor:VBArs:DELTa? might return :DISPLAY:MATHFFTVIEW1:CURSOR:VBARS:DELTA 1.9144661308840E+9, indicating the deltaT cursor value is 1.9 GHz.
Sets or queries the waveform cursor A position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | The Math-FFT waveform number. |
| <NR3> | real | - | The waveform cursor A position in the specified plot view. |
DISplay:MATHFFTView1:CURSor:WAVEform:APOSition 600.0e6 sets the position to 600 MHz. DISplay:MATHFFTView1:CURSor:WAVEform:APOSition? might return :DISPLAY:MATHFFTVIEW1:CURSOR:WAVEFORM:APOSITION 25.000E+6, indicating the cursor position is 25 MHz.
Sets or queries the waveform cursor A position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
DISplay:MATHFFTView1:CURSor:WAVEform:APOSition 600.0e6 DISplay:MATHFFTView1:CURSor:WAVEform:APOSition?
Sets or queries the waveform cursor B position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | The Math-FFT waveform number. |
| position | real | - | The waveform cursor B position in the specified plot view. |
DISplay:MATHFFTView1:CURSor:WAVEform:BPOSition 2.0E+9 sets the cursor position to 2.0 GHz. DISplay:MATHFFTView1:CURSor:WAVEform:BPOSition? might return :DISPLAY:MATHFFTVIEW1:CURSOR:WAVEFORM:BPOSITION 250.0E+6, indicating the waveform cursor B position is 250 MHz.
Sets or queries the waveform cursor B position for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | The Math-FFT waveform number. |
| position | real | - | The waveform cursor B position in the specified plot view. |
DISplay:MATHFFTView1:CURSor:WAVEform:BPOSition 2.0E+9 DISplay:MATHFFTView1:CURSor:WAVEform:BPOSition?
Sets or queries the grid lines setting for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | HORizontal | VERTical | BOTH | Selects which grid lines are shown in the Math-FFT view. |
Returns the grid line orientation for the specified Math-FFT view. The response can indicate horizontal, vertical, or both grid lines.
DISplay:MATHFFTView1:GRIDlines VERTICAL specifies vertical grid lines. DISplay:MATHFFTView1:GRIDlines? might return :DISPLAY:MATHFFTVIEW1:GRIDLINES BOTH, indicating both horizontal and vertical grid lines are displayed.
Sets or queries the display state of the specified math waveform for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| state | enum | OFF | ON | <NR1> | OFF disables displaying the specified Math-FFT view; ON enables it; <NR1> = 0 disables the specified Math-FFT view and any other value enables it. |
DISplay:MATHFFTView1:MATH:MATH1:STATE ON enables the specified Math-FFT view. DISplay:MATHFFTView4:MATH:MATH4:STATE? might return :DISPLAY:MATHFFTVIEW1:MATH:MATH1:STATE 1, indicating the waveform Math-FFT 1 is displayed.
Sets or queries the x-axis scale for the specified Math-FFT view. The scale can be linear or logarithmic.
Queries the horizontal scale setting for the specified Math-FFT view. The scale can be linear or logarithmic.
DISplay:MATHFFTView1:XAXIS:SCALE LOG specifies a logarithmic scale. DISplay:MATHFFTView1:XAXIS:SCALE? might return :DISPLAY:MATHFFTVIEW1:XAXIS:SCALE LINEAR, indicating that the scale setting is linear.
Sets or queries the vertical scale setting for the specified Math-FFT view. The scale can be linear or dBm.
DISplay:MATHFFTView1:YAXIS:SCALE LINEAR specifies a linear scale. DISplay:MATHFFTView1:YAXIS:SCALE? might return :DISPLAY:MATHFFTVIEW1:YAXIS:SCALE DBM, indicating that the scale is dBm.
Sets or queries the vertical scale setting for the specified Math-FFT view. The scale can be linear or dBm.
DISplay:MATHFFTView1:YAXIS:SCALE LINEAR specifies a linear scale. DISplay:MATHFFTView1:YAXIS:SCALE? might return :DISPLAY:MATHFFTVIEW1:YAXIS:SCALE DBM, indicating that the scale is dBm.
Sets or queries the value of the left edge of the zoom area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Math-FFT waveform number. |
| from | real | - | Value of the left edge of the zoom x axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:XAXIS:FROM 800.e6 sets the x axis value of the left edge of the plot view to 800 MHz. DISplay:MATHFFTView1:ZOOM:XAXIS:FROM? might return DISPLAY:MATHFFTVIEW1:ZOOM:XAXIS:FROM781.0E+6, indicating the x axis value of the left edge of the plot view is at 781 MHz.
Sets or queries the value of the left edge of the zoom area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| value | real | - | Value of the left edge of the zoom x axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:XAXIS:FROM 800.e6 DISplay:MATHFFTView1:ZOOM:XAXIS:FROM?
Sets or queries the value of the right edge of the zoom area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| value | real | - | Right edge of the zoom x axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:XAXIS:TO 2.3E+9 DISplay:MATHFFTView1:ZOOM:XAXIS:TO? might return :DISPLAY:MATHFFTVIEW1:ZOOM:XAXIS:TO 2.343750E+9, indicating the value of the right edge of the zoom x axis is 2.34 GHz.
Sets or queries the value of the right edge of the zoom x axis for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| value | real | - | Right edge value of the zoom x axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:XAXIS:TO 2.3E+9 DISplay:MATHFFTView1:ZOOM:XAXIS:TO?
Sets or queries the bottom edge value of the zoom y-axis area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
| value | real | - | Bottom value of the zoom y axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:YAXIS:FROM -75.0e0 DISplay:MATHFFTView1:ZOOM:YAXIS:FROM?
Sets or queries the bottom edge value of the zoom y-axis area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | Math-FFT waveform number. |
| value | real | - | Bottom value of the zoom y axis in the specified plot view. |
DISplay:MATHFFTView1:ZOOM:YAXIS:FROM -75.0e0 DISplay:MATHFFTView1:ZOOM:YAXIS:FROM? might return :DISPLAY:MATHFFTVIEW1:ZOOM:YAXIS:FROM -78.8258285893367, indicating the bottom value of the y axis is -78.8 dBm.
Sets or queries the top edge value of the zoom y-axis area for the specified Math-FFT view.
| Name | Type | Values | Description |
|---|---|---|---|
| MATHFFTView<x> | integer | - | Math-FFT waveform number. |
| <NR3> | real | - | Top value of the zoom y axis in the specified plot view. |
Returns or sets the top value of the zoom y axis in the specified Math-FFT plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math-FFT waveform number. |
DISplay:MATHFFTView1:ZOOM:YAXIS:TO 21.0E0 DISplay:MATHFFTView1:ZOOM:YAXIS:TO?
Sets or returns the badge navigation type for WBG measurements. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | ALLOCCURRENCES | FAILURES | Badge navigation type for WBG measurements. |
DISplay:MEAS1:NAVIgate:TYPE ALLOCCURRENCES DISplay:MEAS1:NAVIgate:TYPE?
Sets or returns the badge navigation type for WBG measurements. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | ALLOCCURRENCES | FAILURES | Badge navigation type for WBG measurements. |
DISplay:MEAS1:NAVIgate:TYPE? might return :DISplay:MEAS1:NAVIgate:TYPE ALLOCCURRENCES, indicating that the badge navigation type is all occurrences.
Sets or queries the display persistence for analog waveforms. Persistence is valid for wave views only.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | OFF | AUTO | INFPersist | INFInite | VARpersist | CLEAR | Display persistence mode. |
Sets or queries the display persistence for analog waveforms. Persistence is valid for wave views only.
Clears the persistence data that has built up over time. Persistence is valid for wave views only.
DISPLAY:PERSISTENCE:RESET clears the display of persistence data.
Sets or queries the enabled state of autoscale for the specified plot.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| state | enum | OFF | ON | Disables or enables the autoscale feature. |
| value | numeric | - | Any nonzero value enables autoscale; 0 disables it. |
DISplay:PLOTView1:AUTOScale OFF turns off plot autoscale.
Sets or queries the enabled state of autoscale for the specified plot.
DISplay:PLOTView1:AUTOScale OFF turns off plot autoscale.
Queries the cursor source for plot cursor A.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
DISplay:PLOTView1:CURSor:ASOUrce? might return DISPLAY:PLOTVIEW1:CURSOR:ASOURCEPLOT 1 indicating the source of the cursor is plot 1.
Queries the cursor source for plot cursor B.
| Name | Type | Values | Description |
|---|---|---|---|
| PLOTView<x> | - | - | The Plot waveform number. |
DISplay:PLOTView1:CURSor:BSOUrce? might return :DISPLAY:PLOTVIEW1:CURSOR:BSOURCEPLOT 1, indicating the B cursor source is plot 1.
Returns the delta V over delta T cursor readout value for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
Sets or queries the cursor mode for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | WAVEFORM | VBArs | HBArs | SCREEN | Cursor mode for the specified Plot view. |
DISplay:PLOTView1:CURSor:FUNCtionVBARS DISplay:PLOTView1:CURSor:FUNCtion?
Sets or queries the cursor mode for the specified Plot view. The mode can be WAVEFORM, VBArs, HBArs, or SCREEN.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | WAVEFORM | VBArs | HBArs | SCREEN | Cursor mode for the specified Plot view. |
DISplay:PLOTView1:CURSor:FUNCtionVBARS DISplay:PLOTView1:CURSor:FUNCtion?
Sets or queries the horizontal cursor A position for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Cursor position. |
DISplay:PLOTView<x>:CURSor:HBArs:APOSition 2.0 DISplay:PLOTView<x>:CURSor:HBArs:APOSition?
Sets or queries the horizontal cursor B position for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Horizontal cursor B position. |
DISplay:PLOTView<x>:CURSor:HBArs:BPOSition 2.0 sets the cursor to 2 Volts.
Queries the horizontal cursor A vertical units for the specified Plot view.
DISplay:PLOTView1:CURSor:HBArs:AUNIts? might return :DISPLAY:PLOTVIEW1:CURSOR:HBARS:AUNITS"V",
Sets or queries the horizontal cursor B position for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | HBArs vertical position. |
DISplay:PLOTView<x>:CURSor:HBArs:BPOSition 2.0 sets the cursor to 2 Volts.
Queries the horizontal cursor B vertical units for the specified Plot view.
DISplay:PLOTView1:CURSor:HBArs:BUNIts? might return :DISPLAY:PLOTVIEW1:CURSOR:HBARS:BUNITS "V"
Returns the HBars cursor position readout value for the specified Plot view. The example shows the returned value as a voltage.
Queries the delta V cursor readout value for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
DISplay:PLOTView1:CURSor:HBArs:DELTa? might return :DISPLAY:PLOTVIEW1:CURSOR:HBARS:DELTA 1.2543, indicating the delta value is 1.2543 V.
Sets or queries the cursor tracking mode for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | INDEPENDENT | TRACK | Selects whether the two cursors adjust independently or track together. |
DISplay:PLOTView1:CURSor:MODeTRACK DISplay:PLOTView1:CURSor:MODe? might return :DISPLAY:PLOTVIEW1:CURSOR:MODE INDEPENDENT, indicating independent adjustment of the cursors is allowed.
Sets or queries the cursor tracking mode for the specified Plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| mode | enum | INDEPENDENT | TRACK | Cursor tracking mode; INDEPENDENT allows independent adjustment of the two cursors, and TRACK ties them together. |
DISplay:PLOTView1:CURSor:MODeTRACK DISplay:PLOTView1:CURSor:MODe?
Returns the one over delta T cursor readout value for the specified plot waveform. The returned value is an <NR3> and may not be delta T depending on the plot units.
DISplay:PLOTView<x>:CURSor:ONEOVERDELTATVALUE? might return :DISPLAY:PLOTVIEW1:CURSOR:ONEOVERDELTATVALUE 88.2295E+6 indicating the 1 over delta time value is 88.2295 MHz.
Sets or queries the location where the specified plot cursor readouts are displayed, either in the plot graticule or as a badge in the Results Bar.
| Name | Type | Values | Description |
|---|---|---|---|
| location | enum | GRATICULE | BADGE | Display location for the plot cursor readouts. |
DISplay:PLOTView1:CURSor:ROLOCATION GRATICULE DISplay:PLOTView2:CURSor:ROLOCATION? might return DISplay:PLOTView2:CURSor:ROLOCATION BADGE, indicating that cursor readout information for plot 2 is set to display as a badge in the Results Bar.
Sets or queries the location where plot cursor readouts are displayed, either in the plot graticule or as a badge in the Results Bar.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | GRATICULE | BADGE | Selects where the plot cursor readouts are shown. |
DISplay:PLOTView1:CURSor:ROLOCATION GRATICULE DISplay:PLOTView2:CURSor:ROLOCATION? might return DISplay:PLOTView2:CURSor:ROLOCATION BADGE, indicating that cursor readout information for plot 2 is set to display as a badge in the Results Bar.
Sets or queries the horizontal cursor A position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Horizontal cursor A position. |
Returns the horizontal cursor A position in the specified Plot view. The response includes the command header and the cursor position value.
DISplay:PLOTView1:CURSor:SCREEN:AXPOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:SCREEN:AXPOSITION -5.5460E-9, indicating the cursor A X position is -5.546 ns.
Sets or queries the vertical cursor A position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Vertical cursor A position. |
DISplay:PLOTView1:CURSor:SCREEN:AYPOSition 2.0 set the A cursor Y position to 2.0 Volts. DISplay:PLOTView1:CURSor:SCREEN:AYPOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:SCREEN:AYPOSITION 1.9035 indicating the A cursor Y position is 1.9035 V.
Sets or queries the vertical cursor A position of the specified cursor in the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Vertical cursor A position. |
DISplay:PLOTView1:CURSor:SCREEN:AYPOSition 2.0 set the A cursor Y position to 2.0 Volts. DISplay:PLOTView1:CURSor:SCREEN:AYPOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:SCREEN:AYPOSITION 1.9035 indicating the A cursor Y position is 1.9035 V.
Sets the horizontal cursor B position of the specified cursor in the specified plot view. The view is selected by the PLOTView<x> node.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Horizontal cursor B position. |
DISplay:PLOTView1:CURSor:SCREEN:BXPOSition 59.0E-9 sets the B cursor X position to 59.0 ns.
Sets or queries the vertical cursor B X position in the specified plot view. The query returns the current B cursor X position.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
Sets or queries the vertical cursor B position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Vertical cursor B position. |
DISplay:PLOTView1:CURSor:SCREEN:BYPOSition 0.589 sets the B cursor Y position to 589 mV. DISplay:PLOTView1:CURSor:SCREEN:BYPOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:SCREEN:BYPOSITION 589.0696E-3 indicating the B cursor Y position is 589.0696 mV.
Sets or queries the vertical cursor B position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | The vertical cursor B position. |
DISplay:PLOTView1:CURSor:SCREEN:BYPOSition 0.589 DISplay:PLOTView1:CURSor:SCREEN:BYPOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:SCREEN:BYPOSITION 589.0696E-3 indicating the B cursor Y position is 589.0696 mV.
Sets or queries the cursor source mode in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SAME | SPLIT | Specifies whether both cursors are on the same waveform or can be on different waveforms. |
Sets or queries the cursor source mode in the specified view.
Sets or queries the cursor state for the specified plot waveform view. OFF disables the specified cursor, ON enables it, and <NR1> uses 0 to disable and any other value to enable.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | Enables or disables the specified cursor. |
| state | integer | 0 | Numeric cursor state: 0 disables the specified cursor; any other value enables it. |
DISplay:PLOTView1:CURSor:STATE OFF disables the specified cursor. DISplay:PLOTView5:CURSor:STATE? might return :DISPLAY:PLOTVIEW5:CURSOR:STATE 1, indicating cursors are on.
Enables or disables the specified cursor in the specified plot view. The query returns the cursor state as 0 or 1.
DISplay:PLOTView5:CURSor:STATE? might return :DISPLAY:PLOTVIEW5:CURSOR:STATE 1, indicating cursors are on.
Sets or queries the vertical cursor A position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | - | Vertical cursor A position. |
DISplay:PLOTView1:CURSor:VBArs:APOSition 50.0E-9 DISplay:PLOTView1:CURSor:VBArs:APOSition?
Sets or queries the vertical cursor A position of the specified cursor in the specified plot view.
DISplay:PLOTView1:CURSor:VBArs:APOSition 50.0E-9 DISplay:PLOTView1:CURSor:VBArs:APOSition?
Sets or queries the vertical cursor B position of the specified cursor in the specified view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Vertical cursor B position. |
Sets or queries the B position of the VBars cursor in the specified Plot waveform view. The argument <NR3> is the vertical cursor B position.
| Name | Type | Values | Description |
|---|---|---|---|
| PLOTView<x> | integer | - | Plot waveform number. |
:DISPLAY:PLOTVIEW1:CURSOR:VBARS:BPOSITION 50.0E-9 :DISPLAY:PLOTVIEW1:CURSOR:VBARS:BPOSITION? might return :DISPLAY:PLOTVIEW1:CURSOR:VBARS:BPOSITION -60.0796E-9 indicating the VBARS BPOSITION is set to 60.08 ns.
Queries the delta T cursor readout value for the specified cursor in the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Plot waveform number. |
DISplay:PLOTView1:CURSor:VBArs:DELTa? might return :DISPLAY:PLOTVIEW1:CURSOR:VBARS:DELTA 119.7593E-9, indicating the VBARSDELTA is set to 119.76 ns.
Queries the VBArs cursor readout units for the specified plot view.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
DISplay:PLOTView<x>:CURSor:VBArs:UNIts? DISplay:PLOTVIEW5:CURSOR:VBARS:UNITS "V"
Sets or queries the waveform cursor A position in the specified plot view. For XY plots, setting has no effect; for bathtub plots it controls or returns the cursor A vertical position, otherwise it controls or returns the horizontal position.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| position | real | - | Horizontal cursor A position. |
DISplay:PLOTView1:CURSor:WAVEform:APOSition -50.0E-9 sets the waveform APOSITION to -50.0 ns. DISplay:PLOTView1:CURSor:WAVEform:APOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:WAVEFORM:APOSITION -60.0796E-9 indicating the waveform APOSITION is set to -60.08 ns.
Sets or queries the waveform cursor A position in the specified plot view. For XY plots, setting has no effect; for bathtub plots it sets or returns the cursor A vertical position, and for all other plots it sets or returns the cursor A horizontal position.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Plot waveform number. |
DISplay:PLOTView1:CURSor:WAVEform:APOSition -50.0E-9 sets the waveform APOSITION to -50.0 ns. DISplay:PLOTView1:CURSor:WAVEform:APOSition? might return :DISPLAY:PLOTVIEW1:CURSOR:WAVEFORM:APOSITION -60.0796E-9 indicating the waveform APOSITION is set to -60.08 ns.
Sets or queries the waveform cursor B horizontal position of the specified cursor in the specified view. In XY plot it has no effect when setting; in bathtub plot it has no effect and the query returns invalid values.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 6 | Plot waveform number. |
| position | real | - | Horizontal cursor B position. |
DISplay:PLOTView1:CURSor:WAVEform:BPOSition 3.0 sets the position to 3.0 V. DISplay:PLOTView5:CURSor:WAVEform:BPOSition? might return :DISPLAY:PLOTVIEW5:CURSOR:WAVEFORM:BPOSITION 2.600517840, indicating the position is 2.5 V.
Sets or queries the waveform cursor B horizontal position of the specified cursor in the specified view. In XY plot it has no effect when setting; in bathtub plot it has no effect and queries return invalid values.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
DISplay:PLOTView1:CURSor:WAVEform:BPOSition 3.0 sets the position to 3.0 V. DISplay:PLOTView5:CURSor:WAVEform:BPOSition? might return :DISPLAY:PLOTVIEW5:CURSOR:WAVEFORM:BPOSITION 2.600517840, indicating the position is 2.5 V.
Sets or queries the grid (graticule) lines setting of the specified plot. It works only for plots that have vertical and horizontal units associated with the graticule, not XY or XYZ plots.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| mode | enum | HORizontal | VERTical | BOTH | Grid lines to display. |
DISplay:PLOTView1:GRIDlines Vertical DISplay:PLOTView1:GRIDlines?
Sets or queries the grid (graticule) lines setting of the specified plot. It works only for plots with vertical and horizontal units associated with the graticule, not for XY or XYZ plots.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
DISplay:PLOTView1:GRIDlines Vertical DISplay:PLOTView1:GRIDlines?
Sets or queries the horizontal scale setting for the specified plot view. The scale may be linear or logarithmic.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Plot waveform number. |
| scale | enum | LINEAR | LOG | Horizontal scale type. |
DISPLAY:PLOTVIEW1:XAXIS:SCALE LOG creates a plot with a logarithmic horizontal scale. DISPLAY:PLOTVIEW1:XAXIS:SCALE? might return :DISPLAY:PLOTVIEW1:XAXIS:SCALE LINEAR indicating plots will have linear scales.
Queries the Cursor A horizontal bar’s vertical position where it crosses the spectrum signal in the Spectrum View.
Queries the vertical position of Cursor B in the Spectrum View. <x> is always 1 and specifies the Spectrum View number.
DISplay:SPECView1:CURSor:CURSOR:HBArs:BPOSition? might return DISplay:SPECView1:CURSor:CURSOR:HBArs:BPOSition -67.8 indicating the Cursor A vertical position is -67.8 units (such as dBm).
Sets or queries whether the Spectrum View cursors display the same or different sources. The command applies to Spectrum View <x>, where <x> is always 1.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SAME | SPLIT | Selects whether both Spectrum View cursors have the same source or independent sources. |
DISplay:SPECView1:CURSor:CURSOR:SPLITMODE SPLIT DISplay:SPECView1:CURSor:CURSOR:SPLITMODE?
Sets or queries whether both Spectrum View cursors have the same or different sources.
DISplay:SPECView1:CURSor:CURSOR:SPLITMODE SPLIT DISplay:SPECView1:CURSor:CURSOR:SPLITMODE?
Sets or queries the visibility state of the cursors in the Spectrum View.
Sets or queries the Cursor A vertical bar’s horizontal position in the Spectrum View.
DISplay:SPECView1:CURSor:CURSOR:VBArs:APOSition 50E+6 DISplay:SPECView1:CURSor:CURSOR:VBArs:APOSition? might return
Sets or queries the Cursor A horizontal position in the Spectrum View. The position is specified in Hz and is limited to the frequencies at the left and right edges of the Spectrum View for the cursor source.
DISplay:SPECView1:CURSor:CURSOR:WAVEform:APOSition? might return DISplay:SPECView1:CURSor:CURSOR:WAVEform:APOSition 48.5E+6, indicating the Spectrum View Cursor A position is 48.5 MHz.
Sets or queries the Cursor B horizontal position in the Spectrum View.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | Hz | Horizontal position of Spectrum View Cursor B. |
| x | integer | 1 - 1 | Spectrum View number; x is always 1. |
DISplay:SPECView1:CURSor:CURSOR:WAVEform:BPOSition 22E+6 DISplay:SPECView1:CURSor:CURSOR:WAVEform:BPOSition? might return DISplay:SPECView1:CURSor:CURSOR:WAVEform:BPOSition 48.5E+6, indicating the Spectrum View Cursor B position is 48.5 MHz.
Sets or queries the type of graticule shown in the Spectrum View window. The same grid is used for all spectrum traces.
DISplay:SPECView1:GRAticule TIME DISplay:SPECView1:GRAticule? might return GRID, indicating that the Spectrum View is showing a Grid graticule.
Queries the Spectrum View horizontal scaling setting. The Spectrum View number <x> is always 1.
DISplay:SPECView1:HORZ? might return DISplay:SPECView1:HORZ LOG, indicating that the horizontal display scaling in the Spectrum View window is set to log.
Sets or queries the graticule saturation (brightness) level in the Spectrum View window. It also changes the intensity of the vertical scale values on the graticule.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 1 | Spectrum View number; <x> is always 1. |
| level | real | 0% - 100% | Spectrum View graticule intensity level as a percent. |
DISplay:SPECView1:INTENSITy:GRATicule 75 DISplay:SPECView1:INTENSITy:GRATicule?
Queries the spectrum trace intensity level for Spectrum View 1. The returned value is the spectrum trace saturation level as a percent between 1% and 100%.
DISplay:SPECView1:INTENSITy:WAVEform? might return 80.0, indicating the spectrum trace saturation level is at 80%.
Sets or queries the spectrum trace layout style used by the Spectrum View window.
DISplay:SPECView1:VIEWStyle OVErlay DISplay:SPECView1:VIEWStyle? might return STACKED, indicating the Spectrum View window is showing spectrum traces in stacked mode.
Sets or queries display persistence decay time, the approximate decay time for a freshly struck persistence sample.
Sets or queries the location used to display the Waveform View cursor readouts, either in the graticule or as a badge in the Results Bar.
DISplay:WAVEView:CURSor:CURSOR1:ROLOCATION GRATICULE DISplay:WAVEView:CURSor:CURSOR1:ROLOCATION? might return DISplay:WAVEView:CURSor:CURSOR1:ROLOCATION BADGE
Globally enables or disables the waveform display. When disabled, the waveform is still acquired and held in memory, but it is not drawn to the screen.
DISplay:WAVEform? might return DISplay:WAVEform 1, indicating that the waveform display is enabled.
Returns the Waveform View graticule type.
DISplay:WAVEView:GRIDTYPE? might return FIXED, indicating that the graticule will not change positions if the waveform moves horizontally.
Sets or queries the state of the specified bus in the specified Waveform View. WAVEView<x> must be WAVEView1.
DISplay:WAVEView1:BUS:B1:STATE? might return DISPLAY:WAVEVIEW1:BUS:B1:STATE 1 indicating the specified bus is on.
Returns the vertical position of the specified bus in the specified Waveform View. WAVEView<x> must be WAVEView1.
DISplay:WAVEView1:BUS:B1:VERTical:POSition? might return DISPLAY:WAVEVIEW1:BUS:B1:VERTICAL:POSITION 0.0E+0 indicating the position is 0.0 divisions.
Sets or queries the display state of the specified digital channel in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | <NR1> | OFF | ON | Controls whether the specified digital channels are displayed. 0 disables the display; any other value turns it on. |
DISplay:WAVEView1:CH1_DALL:STATE ON DISplay:WAVEView1:CH1_DALL:STATE? might return DISPLAY:WAVEVIEW1:CH1_DALL:STATE 0 indicating specified digital channels in the specified Waveform View are off.
Sets or queries the display state of the specified digital channel in the specified Waveform View.
DISplay:WAVEView1:CH1_D1:STATE OFF DISplay:WAVEView1:CH1_D1:STATE? might return DISPLAY:WAVEVIEW1:CH1_D1:STATE 1 indicating the specified digital channel is on.
Sets or queries the vertical position of the specified digital channel in the specified Waveform View. The value is in divisions.
DISplay:WAVEView1:CH1_DALL:VERTical:POSition 1.0e0 sets the vertical position to 1.0 divisions. DISplay:WAVEView1:CH1_DALL:VERTical:POSition? might return DISPLAY:WAVEVIEW1:CH1_DALL:VERTICAL:POSITION 0.0E+0 indicating the vertical position is 0.0 divisions.
Turns on, off, or queries the state of the specified channel in the specified Waveform View. The Waveform View index must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Sets the channel state. |
DISplay:WAVEView1:CH1:STATE ON DISplay:WAVEView1:CH1:STATE? might return DISPLAY:WAVEVIEW1:CH1:STATE 0 indicating channel 1 is off.
Queries the vertical position of the specified channel in the specified Waveform View, in divisions. 0.0 divisions is center, 5.0 is the top of the window, and -5.0 is the bottom.
DISplay:WAVEView1:CH1:VERTical:POSition? might return DISPLAY:WAVEVIEW1:CH1:VERTICAL:POSITION -3.4400 indicating the channel 1 vertical position is -3.44 divisions.
Sets or queries the vertical scale of the specified channel in volts per division within the specified Waveform View.
DISplay:WAVEView1:CH1:VERTical:SCAle 2.0e2 sets the vertical scale to 200 mV per division. DISplay:WAVEView1:CH1:VERTical:SCAle? might return DISPLAY:WAVEVIEW1:CH1:VERTICAL:SCALE 200.0000E-3 indicating the scale is 200 mV per division.
Returns the selected cursor A source for the specified cursor in the specified Waveform View. The source may be an analog channel, bus, math channel, reference waveform, plot, or AUTO-selected source.
DISplay:WAVEView1:CURSor:CURSOR1:ASOUrce? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:ASOURCE REF1 indicating the cursor A source is reference 1.
Sets or queries the cursor B source of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
Sets or queries the cursor type of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SCREEN | WAVEFORM | VBArs | HBArs | Cursor type to set. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:FUNCTION VBArs DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:FUNCTION?
Sets or queries the HBARs vertical A position of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
| Name | Type | Values | Description |
|---|---|---|---|
| position | real | -5.0 - 5.0 | Vertical cursor A position in the specified Waveform View; 0.0 divisions is center, 5.0 is top, and -5.0 is bottom. |
DISplay:WAVEView1:CURSor:CURSOR1:HBArs:APOSition 3.0e0 DISplay:WAVEView1:CURSor:CURSOR1:HBArs:APOSition?
Queries the vertical cursor B position of the specified cursor in the specified Waveform View.
DISplay:WAVEView1:CURSor:CURSOR1:HBArs:BPOSition? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:HBARS:BPOSITION 387.9148706896567E-3 indicating the B cursor position is 387.9 mV.
Sets or queries the cursor tracking mode of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | INDEPENDENT | TRACK | Selects the cursor tracking mode. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:MODE TRACK DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:MODE? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:MODE TRACK, indicating that the two cursors move in unison.
Sets or queries the horizontal cursor A position of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Horizontal cursor A position of the specified cursor in the specified Waveform View. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:AXPOSITION 15.0E-3 DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:AXPOSITION?
Sets or queries the vertical cursor A position of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The vertical cursor A position of the specified cursor in the specified Waveform View. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:AYPOSITION 25.0E-3 DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:AYPOSITION? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:AYPOSITION -53.0000E-03
Sets or queries the horizontal cursor B position of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The horizontal cursor B position of the specified cursor in the specified Waveform View. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:BXPOSITION 15.0E-3 DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:BXPOSITION? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:BXPOSITION -64.0000E-03
Sets or queries the vertical cursor B position of the specified cursor in the specified Waveform View. WAVEView<x> must be WAVEView1 and Cursor<x> must be CURSOR1.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The vertical cursor B position of the specified cursor in the specified Waveform View. |
DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:BYPOSITION 25.0E-3 DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SCREEN:BYPOSITION?
Queries the split mode of the specified cursor in the specified Waveform View. SAME indicates both cursors have the same source; SPLIT indicates the cursors have different sources.
DISplay:WAVEView1:CURSor:CURSOR1:SPLITMODE? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:SPLITMODE SAME indicating the cursors have the same source.
Sets or queries the visible state of the specified cursor in the specified Waveform View.
Returns the horizontal cursor A position of the specified cursor in the specified Waveform View.
DISplay:WAVEView1:CURSor:CURSOR1:VBArs:APOSition? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:VBARS:APOSITION -5.0E-6 indicating the cursor A position is -5.0 μs.
Sets or queries the cursor B horizontal position of the specified cursor in the specified Waveform View.
Sets or queries the horizontal cursor A position of the specified cursor in the specified Waveform View.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Horizontal cursor A position of the specified cursor in the specified Waveform View. |
DISplay:WAVEView1:CURSor:CURSOR1:WAVEform:APOSition 1.5e-6 DISplay:WAVEView1:CURSor:CURSOR1:WAVEform:APOSition? might return DISPLAY:WAVEVIEW1:CURSOR:CURSOR1:WAVEFORM:APOSITION -1.2667480236557E-6
Sets or queries the type of interpolation filter for the display. WAVEView<x> must be WAVEView1.
Selects or queries the type of graticule displayed for the specified Waveform View. WAVEView<x> must be WAVEView1.
DISplay:WAVEView1:GRAticule TIME DISplay:WAVEView1:GRAticule?
Sets or queries the graticule saturation level for the specified Waveform View. The value is given as an NR2 percentage.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | % | Graticule saturation level. |
DISplay:WAVEView1:INTENSITy:GRATicule 75 DISplay:WAVEView1:INTENSITy:GRATicule?
Sets or queries the waveform saturation level for the specified Waveform View. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | % | Waveform saturation level. |
DISplay:WAVEView1:INTENSITy:WAVEform 75 DISplay:WAVEView1:INTENSITy:WAVEform?
Sets or queries whether the specified math is auto-scaled when the math equation changes within the specified Waveform View.
Sets or queries the state of the specified math waveform in the specified Waveform View. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | NR1 | OFF | ON | Turns the specified math waveform off or on; <NR1> = 0 disables it and any other value enables it. |
DISplay:WAVEView1:MATH:MATH1:STATE OFF DISplay:WAVEView1:MATH:MATH2:STATE? might return DISPLAY:WAVEVIEW1:MATH:MATH2:STATE 1 indicating the math is displayed.
Sets or queries the vertical position in divisions of the specified math waveform in the specified Waveform View.
DISplay:WAVEView1:MATH:MATH1:VERTical:POSition 0 DISplay:WAVEView1:MATH:MATH1:VERTical:POSition?
Sets or queries the vertical scale of the specified math waveform in volts per division within the specified Waveform View. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | V/div | Vertical scale of the specified math waveform. |
DISplay:WAVEView1:MATH:MATH1:VERTical:SCAle 400e-3 sets the scale to 400 mV per division. DISplay:WAVEView1:MATH:MATH1:VERTical:SCAle? might return DISPLAY:WAVEVIEW1:MATH:MATH1:VERTICAL:SCALE 395.0000E-3 indicating the scale is 395 mV.
Sets or queries whether the specified trend gets auto-scaled when new data is available within the specified Waveform View.
DISplay:WAVEView1:PLOT:PLOT1:AUTOScale 1 enables auto-scaling the specified plot in the specified Waveform View. DISplay:WAVEView1:PLOT:PLOT1:AUTOScale? might return DISPLAY:WAVEVIEW1:PLOT:PLOT1:AUTOSCALE 0 indicating that auto-scaling for plot 1 is off.
Returns the on/off state of the specified plot in the specified Waveform View. A response of 1 indicates the plot is on; 0 indicates it is off.
DISplay:WAVEView1:PLOT:PLOT1:STATE? might return DISPLAY:WAVEVIEW1:PLOT:PLOT1:STATE 1 indicating the specified plot in the specified Waveform View is on.
Sets or queries the vertical position of the specified time trend in the specified Waveform View in absolute units.
Sets or queries the vertical scale of the specified plot in a Waveform View. The query returns the current scale value.
DISplay:WAVEView1:PLOT:PLOT1:VERTical:SCAle 725.0e-3 DISplay:WAVEView1:PLOT:PLOT1:VERTical:SCAle?
Sets or queries the state of the specified reference waveform in the specified Waveform View. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | OFF | ON | Disables the specified reference when 0 or OFF is used; any other value turns it on. |
DISplay:WAVEView1:REF:REF1:STATE OFF DISplay:WAVEView1:REF:REF1:STATE? might return DISPLAY:WAVEVIEW1:REF:REF1:STATE 1 indicating the specified reference in the specified Waveform View is on.
Sets or returns the selected frame of the specified digital ref. Each reference has a unique selected frame.
| Name | Type | Values | Description |
|---|---|---|---|
| frame | integer | - | Selected frame of the specified digital ref. |
DISplay:WAVEView1:REF1_DALL:FRAMe? might return DISPLAY:WAVEVIEW1:REF1_DALL:FRAME 1, indicating the selected frame is 1.
Sets or queries the vertical position of the specified reference in the Waveform View, in divisions.
DISplay:WAVEView1:REF:REF1:VERTical:POSition -2.5e0 DISplay:WAVEView1:REF:REF1:VERTical:POSition?
Sets or queries the vertical scale of the specified reference in volts per division within the specified Waveform View. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | V/div | The vertical scale of the specified reference waveform. |
DISplay:WAVEView1:REF:REF1:VERTical:SCAle 400e-3 DISplay:WAVEView1:REF:REF1:VERTical:SCAle?
Sets or queries the vertical position of the specified Frequency vs. Time trace in the Waveform View, in divisions. For this command, WAVEView<x> is always WAVEView1 and RF_FREQuency<x> specifies the waveform number.
DISplay:WAVEView1:RF_FREQuency1:VERTical:POSition? might return DISplay:WAVEView1:RF_FREQuency1:VERTical:POSition -4.79, indicating the Channel 1 Frequency vs. Time vertical position is -4.79 divisions.
Sets or queries the vertical scale of the specified Frequency vs. Time trace in the Waveform View, in Hertz per division.
DISplay:WAVEView1:RF_FREQuency2:VERTical:SCAle? might return DISplay:WAVEView1:RF_FREQuency2:VERTical:SCAle 2.0E3, indicating the vertical scale of the Channel 2 Frequency vs. Time trace is 2KHz per division.
Queries the vertical position of the specified Magnitude vs. Time trace in the specified Waveform View. The value is returned in divisions, with 0.0 at center.
Sets or queries the vertical scale of the specified Magnitude vs. Time trace in the specified Waveform View. The scale is in volts, watts, or dB per division depending on the Magnitude Format setting.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Sets the vertical scale. |
DISplay:WAVEView1:RF_MAGnitude3:VERTical:SCAle 5.0 DISplay:WAVEView1:RF_MAGnitude2:VERTical:SCAle?
Sets or queries the vertical position of the specified Phase vs. Time trace in Waveform View, in divisions.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | WAVEView<x> is always WAVEView1. |
| x | integer | - | RF_PHASe<x> specifies the number of the Phase vs. Time Frequency waveform. |
| position | real | divisions | Sets the vertical position in divisions. 0.0 divisions is center, 5.0 is the top of the Waveform View, and -5.0 is the top of the Waveform View. |
DISplayWAVEView1:RF_PHASe1:VERTical:POSition? might return DISplayWAVEView1:RF_PHASe1:VERTical:POSition -1.7, indicating the Channel 1 Phase vs. Time vertical position is -1.7 divisions.
Sets or queries the vertical scale of the specified Phase vs. Time trace in the specified Waveform View, in degrees per division.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | deg/div | Sets the vertical scale, in degrees per division. |
Sets or queries how the waveforms are displayed for analysis mode. WAVEView<x> must be WAVEView1.
DISplay:WAVEView1:STYle VECTORS DISplay:WAVEView1:STYle?
Sets or queries the waveform layout style used by the display. WAVEView<x> must be WAVEView1.
| Name | Type | Values | Description |
|---|---|---|---|
| style | enum | OVErlay | STAcked | Specifies whether the display view style is overlay or stacked. |
DISplay:WAVEView1:VIEWStyle OVERLAY sets the view style to overlay. DISplay:WAVEView1:VIEWStyle? might return DISPLAY:WAVEVIEW1:VIEWSTYLE STACKED indicating the view style is stacked.
Returns the horizontal position of the specified zoom box in the specified Waveform View. The value is the percent of the waveform that is to the left of screen center, when the zoom factor is 2× or greater.
DISPLAY:WAVEVIEW1:ZOOM:ZOOM1:HORIZONTAL:POSITION? might return
Sets or queries the horizontal zoom factor of the specified zoom in the specified Waveform View. WAVEView<x> must be WAVEView1 and ZOOM<x> must be ZOOM1.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 1 - 2-4 | Amount of expansion in the horizontal direction in 1-2-4 increments. |
DISPLAY:WAVEVIEW1:ZOOM:ZOOM1:HORIZONTAL:SCALe 5 DISPLAY:WAVEVIEW1:ZOOM:ZOOM1:HORIZONTAL:SCALe? might return DISPLAY:WAVEVIEW1:ZOOM:ZOOM1:HORIZONTAL:SCALe 10
Sets or queries the horizontal scale of the specified zoom window.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The horizontal scale of the zoom window. |
DISplay:WAVEView1:ZOOM:ZOOM1HORizontal:WINSCALe? might return
Sets or queries the zoom display state of the specified zoom in the specified Waveform View. This command is equivalent to pushing the zoom button on the front panel.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the specified zoom on or off. |
| value | integer | 0 | Enables the specified zoom for any nonzero value and disables it for 0. |
DISplay:WAVEView1:ZOOM:ZOOM1:STATe ON DISplay:WAVEView1:ZOOM:ZOOM1:STATe? might return DISplay:WAVEView1:ZOOM:ZOOM1:STATe 1, indicating that specified zoom is on.
Returns the vertical position of the specified zoom in the specified Waveform View. The position is freely movable within the confines of the acquired waveform.
DISplay:WAVEView1:ZOOM:ZOOM1:VERTical:POSition? might return DISplay:WAVEView1:ZOOM:ZOOM1:VERTical:POSition 23.90000, indicating that the vertical position of the specified zoom in the specified Waveform View is set to 23.9, where the vertical zoom factor is 10x, top of screen is -50 and bottom if +50, and 0 is the vertical center.
Sets or queries the vertical zoom factor of the specified zoom in the specified Waveform View. The entered value uses the nearest scale factor; setting the vertical scale to 1 indicates unity (no zoom).
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Amount of vertical expansion or compression. |
DISplay:WAVEView1:ZOOM:ZOOM2:VERTical:SCALe? might return DISplay:WAVEView1:ZOOM:ZOOM2:VERTical:SCALe 2.0000, indicating that the vertical scale of zoom1 of waveview1 is 2×.
Returns the selected frame of the specified analog ref.
DISplay:WAVEView1:REF:REF2:FRAMe? might return DISPLAY:WAVEVIEW1:REF:REF2:FRAME 1, indicating the selected frame is 1.
Sets the display clock state. The factory default is 1.
Sets the digital display activity state. The factory default is 0.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Enables or disables digital activity display. |
Sets the digital display height. The factory default is MEDIUM.
| Name | Type | Values | Description |
|---|---|---|---|
| height | enum | MEDIUM | Digital display height setting. |
Sets the graticule display mode. The factory default is FULL.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FULL | Graticule display mode. |
Sets the display backlight intensity. The factory default is HIGH.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | Backlight intensity setting. |
Sets the auto-dim enable state for the display backlight. The factory default is 1.
Sets the backlight auto-dim time. The factory default is 60.
| Name | Type | Values | Description |
|---|---|---|---|
| time | integer | - | Auto-dim delay time. |
Sets the graticule intensity. The factory default is 75.
| Name | Type | Values | Description |
|---|---|---|---|
| intensity | integer | - | Graticule intensity setting. |
Sets the waveform display intensity. The factory default is 35.
| Name | Type | Values | Description |
|---|---|---|---|
| intensity | integer | 0 - 100 | Waveform display intensity. |
Sets the display persistence value. The factory default is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| persistence | real | - | Persistence setting value. |
Sets whether only dots are used to display waveforms.
Sets the display trigger frequency option to the factory default value. The factory default for this setting is 0.
Sets or queries whether XY display mode is enabled. The factory default is OFF.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables XY display mode. |
Enables or disables whether the XY display includes a YT trace. The factory default is OFF.
Turns the CH2 waveform on.
| Name | Type | Values | Description |
|---|---|---|---|
| state | integer | 0 - 1 | Sets the display state of the CH2 waveform. |
Turns the CH2 waveform on.
| Name | Type | Values | Description |
|---|---|---|---|
| state | integer | - | Enables or disables the CH2 waveform display. |
Sets or queries the wait time.
Sets or returns the low pass filter specification for a measurement.
Sets or queries the global mechanical Index Z source.
Sets or queries the global mechanical measurement results units.
Sets or queries the global pulses per rotation of the measurement.
Sets or queries the SJ Frequency value.
Sets or queries whether histogram center is percentage relative to unit interval or an absolute value for eye width measurement.
Sets or queries the histogram width in terms of percentage.
| Name | Type | Values | Description |
|---|---|---|---|
| width | real | % | Histogram width in percentage. |
Sets or queries the window length for the measurement.
Returns the horizontal scale units of the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specified measurement number. |
Returns the vertical scale units of the specified measurement.
Sets or queries the global range maximum value.
Sets or queries the global range minimum value.
Sets or queries the global range state.
Sets or queries the measurement gear ratio.
Sets or queries the measurement number of pole pairs.
Sets or queries the global mechanical source of the specified source number.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Source number to select. |
Sets or queries the measurement sensor type.
Sets or queries the minimum number of unit intervals required for BUJ analysis.
Sets or queries the global population limit state.
Sets or queries the global population limit value.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Global population limit value. |
Sets or queries the value used as the high reference level of the falling edge.
Sets or queries the value used as the low reference level of the falling edge.
Sets or queries the value used as the mid reference level of the falling edge.
Sets or queries the value of the hysteresis of the reference level.
Sets or queries the value used as the high reference level of the rising edge.
Sets or queries the value used as the low reference level of the rising edge.
Sets or queries the value used as the mid reference level of the rising edge.
Sets or queries the reference level type.
Sets or queries the method used to calculate the TOP and BASE, used to calculate reference levels.
Sets or queries the burst count for WBG measurement.
Sets or queries the burst delay for WBG measurement.
Returns the AFG test connection status.
Sets or queries the delay for WBG measurement.
Enables or disables generator source one for WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ENABled | DISabled | Turns generator source one on or off for the WBG measurement. |
Enables or disables generator source two for WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | Enables or disables generator source two for WBG measurement. |
Sets or queries the generator address for WBG measurement.
Connects the generator setup for WBG measurement.
Sets or queries the high voltage of the generator for WBG measurement.
Sets or queries the load type of the generator for WBG measurement.
Sets or queries the low voltage of the generator for WBG measurement.
Sets or queries the pulse gap of the generator for WBG measurement.
Sets or queries the pulse width of generator for WBG measurement.
Sets or returns the generator type for WBG measurements.
Sets or returns the number of pulse of AFG for WBG measurements.
Sets or returns the trigger interval of AFG for WBG measurements.
Adds a measurement by name from a fixed list of measurement types.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement_type | enum | ACCOMMONMODE | ACPR | ACRMS | AMPLITUDE | AREA | BASE | BITAMPLITUDE | BITHIGH | BITLOW | BURSTWIDTH | CCJITTER | COMMONMODE | CPOWER | DATARATE | DCD | DDJ | DDRAOS | DDRAOSPERTCK | DDRAOSPERUI | DDRAUS | DDRAUSPERTCK | DDRAUSPERUI | DDRHOLDDIFF | DDRSETUPDIFF | DDRTCHABS | DDRTCHAVERAGE | DDRTCKAVERAGE | DDRTCLABS | DDRTCLAVERAGE | DDRTERRMN | DDRTERRN | DDRTJITCC | DDRTJITDUTY | DDRTJITPER | DDRTPST | DDRTRPRE | DDRTWPRE | DDRVIXAC | DDRTDQSCK | DELAY | DJ | DJDIRAC | DPMPSIJ | EYEHIGH | EYELOW | FALLSLEWRATE | FALLTIME | FREQUENCY | F2 | F4 | F8 | HEIGHT | HEIGHTBER | HIGH | HIGHTIME | HOLD | IMDAANGLE | IMDADIRECTION | IMDADQ0 | IMDAEFFICIENCY | IMDAHARMONICS | IMDAMECHPWR | IMDAPOWERQUALITY | IMDASPEED | IMDASYSEFF | IMDATORQUE | ISI | JITTERSUMMARY | J2 | J9 | LOW | LOWTIME | MAXIMUM | MEAN | MINIMUM | NDUty | NOVERSHOOT | NPERIOD | NPJ | NWIDTH | OBW | PATTERNLENGTH | PDUTY | PERIOD | PHASE | PHASENOISE | PJ | PK2Pk | POVERSHOOT | PWIDTH | QFACTOR | RISESLEWRATE | RISETIME | RJ | RJDIRAC | RMS | SETUP | SJFREQ | SKEW | SRJ | SSCFREQDEV | SSCMODRATE | SSCSLEWRATE | TIE | TIMEOUTSIDELEVEL | TIMETOMAX | TIMETOMIN | TJBER | TNTRATIO | TOP | UNITINTERVAL | VDIFFXOVR | WBGDDT | WBGDIODEDDT | WBGEOFF | WBGEON | WBGERR | WBGIPEAK | WBGIRRM | WBGQOSS | WBGQRR | WBGTDOFF | WBGTDON | WBGTF | WBGTON | WBGTOFF | WBGTR | WBGTRR | WBGTDT | WBGVPEAK | WIDTH | WIDTHBER | Measurement type to add. |
Query-only command that returns all measurement parameters.
MEASUREMENT?
Adds the specified measurement to the measurement group.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | The measurement to add, in the form "MEAS<NR1>" where NR1 6 1. |
MEASUrement:ADDNew "MEAS11" adds measurement 11.
Sets or queries the annotation state for measurements. OFF turns off measurement annotations; AUTO turns on visible measurement annotations.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | AUTO | Controls whether measurement annotations are shown. |
MEASUREMENT:ANNOTATE OFF MEASUREMENT:ANNOTATE?
Sets or queries the annotation state for measurements. OFF turns off measurement annotations, and AUTO turns on visible measurement annotations.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | AUTO | Annotation state for measurements. |
MEASUREMENT:ANNOTATE OFF turns off measurement annotations. MEASUREMENT:ANNOTATE? might return MEASUREMENT:ANNOTATION:STATE OFF, indicating that no measurement annotations are active.
Performs a specified autoset. The available autoset actions include DPM, analysis jitter, IMDA 3 phase, and WBG-related operations.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | DPMAutoset | DPMPReset | EXECute | THREEPHASEAUTOset | WBGDeskewexec | WBGPREset | WBGGSTIM | Specifies which autoset operation to perform. |
MEASUREMENT:AUTOSET EXECute performs an analysis jitter autoset. MEASUREMENT:AUTOSET THREEPHASEAUTOset performs an IMDA 3 phase autoset.
Sets or queries the value used as the high reference level of the falling edge when the source reference level method is set to absolute. The channel number is specified by x.
Sets or queries the value used as the high reference level of the falling edge when the source reference level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| high reference level | real | V | High reference level of the falling edge. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLHIGH 1.5 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLHIGH?
Sets or queries the value used as the low reference level of the falling edge when the source reference level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| level | real | V | Low reference level value for the falling edge. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLLOW 1.5 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLLOW?
Sets or queries the value used as the low reference level of the falling edge when the source reference level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| level | real | V | Low reference level value for the falling edge. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLLOW 1.5 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLLOW? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLLOW 1.5000
Sets or queries the value used as the mid reference level of the falling edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | V | The mid reference level value. |
Sets or queries the mid reference level used to calculate the falling-edge mid reference level when the measurement ref level method is set to Absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | V | Mid reference level used to calculate the falling-edge mid reference level. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLMID 0 sets the mid reference level of the falling edge to 0.0 V. MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLMID? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:FALLMID 0.0E+0 indicating that the mid reference level of the falling edge is 0.0 V.
Sets or queries the hysteresis value of the reference level when the source reference level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| hysteresis | real | - | Hysteresis value used for autoset. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:HYSTERESIS 30.0000E-3 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:HYSTERESIS?
Sets or queries the hysteresis value of the reference level when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Hysteresis value used for autoset. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:HYSTERESIS 30.0000E-3 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:HYSTERESIS?
Sets or queries the high reference level used for the rising edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | integer | - | Channel number specified by x. |
| high reference level | real | V | High reference level of the rising edge when the source ref level method is set to absolute. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEHIGH 1.5 sets the high reference level of the rising edge to 1.5 V. MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEHIGH? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000 indicating that the high reference level of the rising edge is 1.0 V.
Sets or queries the value used as the high reference level of the rising edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | integer | - | Channel number specified by x. |
| high reference level | real | - | High reference level of the rising edge when the source ref level method is set to absolute. |
Sets or queries the value used as the low reference level of the rising edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | - | The low reference level of the rising edge when the source ref level method is set to absolute. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW 1.5 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW 1.0000
Sets or queries the value used as the low reference level of the rising edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number specified in the command mnemonic. |
| low reference level | real | - | Low reference level of the rising edge when the source ref level method is set to absolute. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW 1.5 MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW? MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISELOW 1.0000
Sets or queries the value used as the mid reference level of the rising edge when the source ref level method is set to absolute. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | V | The mid reference level of the rising edge when the source ref level method is set to absolute. |
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEMID 0 sets the mid reference level of the rising edge to 0.0 V. MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEMID? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:RISEMID 0.0E+0 indicating that the mid reference level of the rising edge is 0.0 V.
Sets or queries the method used to calculate reference levels for the measurement. The channel number is specified by x.
Sets or queries the method used to calculate the reference levels for the measurement channel. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | PERCent | ABSolute | Reference level calculation method. |
Queries the absolute reference-level type for the specified measurement channel.
MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:TYPE? might return MEASUREMENT:CH2:REFLEVELS:ABSOLUTE:TYPE SAME indicating that the reference levels for absolute measurements are the same.
Sets or queries the method used to calculate the TOP and BASE reference levels for the specified measurement channel.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | MINMax | MEANhistogram | MODEhistogram | EYEhistogram | Method used to calculate TOP and BASE reference levels. |
MEASUREMENT:CH2:REFLEVELS:BASETOP MINMAX specifies that reference levels are relative to the measurement MIN MEASUREMENT:CH2:REFLEVELS:BASETOP? might return MEASUREMENT:CH2:REFLEVELS:BASETOP AUTO indicating the reference levels are chosen automatically.
Sets or queries the method used to calculate the TOP and BASE used to calculate measurement reference levels. The channel number is specified by x.
MEASUREMENT:CH2:REFLEVELS:BASETOP MINMAX MEASUREMENT:CH2:REFLEVELS:BASETOP?
Sets or queries the method used to calculate reference levels for the measurement channel specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| method | enum | PERCent | ABSolute | The reference level method to use. |
Sets or queries the method used to calculate reference levels for the measurement on the specified channel.
Sets or queries the percentage used to calculate the high reference level of the falling edge when the reference level method is set to percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | 0 - 100 | Percentage used to calculate the high reference level for the falling edge when Ref level method is set to Percent. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLHIGH 90.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLHIGH?
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement Ref level method is set to Percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | integer | - | Channel number specified by x. |
| percent | real | % | Percentage used to calculate the high reference level for the falling edge. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLHIGH 90.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLHIGH?
Sets or queries the percentage used to calculate the low reference level of the falling edge when the measurement ref level method is set to Percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | % | The percentage used to calculate the low reference level when the measurement Ref level method is set to Percent. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLLOW 10.0000 sets the reference levels for the falling edge to 10%. MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLLOW? might return MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLLOW 10.0000 indicating the reference levels for the falling edge is set to 10%.
Sets or queries the percentage used to calculate the low reference level of the falling edge when the source Ref level method is set to Percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| percentage | real | 1 - 100 | Percentage used to calculate the low reference level for the falling edge when the Ref level method is set to Percent. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLLOW 10.0000 sets the reference levels for the falling edge to 10%.
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the reference level method is set to Percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLMiD 50.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:FALLMID?
Sets or queries the percentage used to calculate the hysteresis of the reference level when the measurement ref level method is set to percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| hysteresis | real | % | Percentage used to calculate the hysteresis of the reference level. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:HYSTERESIS 5.0000 sets the reference level hysteresis to 5.0 mV. MEASUREMENT:CH2:REFLEVELS:PERCENT:HYSTERESIS? might return MEASUREMENT:CH2:REFLEVELS:PERCENT:HYSTERESIS 5.0000 indicating the reference level hysteresis is set to 5.0 mV.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement ref level method is set to percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| percentage | real | % | Percentage used to calculate the high reference level for the rising edge when the ref level method is set to Percent. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:RISEHIGH 90.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:RISEHIGH?
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement ref level method is set to percent. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Channel number. |
| percent | real | % | Percentage used to calculate the low reference level of the rising edge. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:RISELOW 10.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:RISELOW? might return MEASUREMENT:CH2:REFLEVELS:PERCENT:RISELOW 10.0000
Sets or queries the percentage mid reference level used for a measurement's rising edge when the Ref level method is Percent. The value is given as a percentage, where 50% is equal to MID.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | % | Percentage used to calculate the mid reference level for the rising edge. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:RISEMiD 50.0000 MEASUREMENT:CH2:REFLEVELS:PERCENT:RISEMID? might return MEASUREMENT:CH2:REFLEVELS:PERCENT:RISEMID 50.0000
Specifies or queries the reference level percent type for the measurement. The channel number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | TENNinety | TWENtyeighty | CUSTom | Reference level percent type. |
MEASUREMENT:CH2:REFLEVELS:PERCENT:TYPE TENNINETY MEASUREMENT:CH2:REFLEVELS:PERCENT:TYPE? might return MEASUREMENT:CH2:REFLEVELS:PERCENT:TYPE TWENTYEIGHTY indicating the reference levels are set to the 20 and 80% levels.
Sets or queries the global advanced clock recovery method. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| method | enum | NONE | NOMinal | PATTern | Global advanced clock recovery method. |
Sets or queries the global clock frequency used when fixed constant clock recovery is used for the measurement. It affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | Hz | Global clock frequency used with Constant Clock - Fixed clock recovery method. |
MEASUREMENT:CLOCKRECOVERY:CLOCKFREQUENCY 2.0E+9 MEASUREMENT:CLOCKRECOVERY:CLOCKFREQUENCY?
Sets or queries the global clock multiplier used when explicit clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| clock multiplier | real | - | Global clock multiplier. |
MEASUREMENT:CLOCKRECOVERY:CLOCKMULTIPLIER 1.000 sets the clock multiplier to 1.000.
Sets or queries the global constant clock mode used when constant clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | MEAN | MEDian | FIXed | Selects the constant clock mode. |
MEASUREMENT:CLOCKRECOVERY:CONSTCLOCKMODE MEAN MEASUREMENT:CLOCKRECOVERY:CONSTCLOCKMODE? might return MEASUREMENT:CLOCKRECOVERY:CONSTCLOCKMODE MEAN indicating the constant clock mode is set to MEAN.
Sets or queries the global damping value used when PLL clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| damping | real | - | Global clock recovery damping value. |
MEASUREMENT:CLOCKRECOVERY:DAMPING MEASUREMENT:CLOCKRECOVERY:DAMPING? might return MEASUREMENT:CLOCKRECOVERY:DAMPING 700.0000E-3
Sets or queries the path and filename of the file containing the data pattern. The file path is supplied in quotes.
| Name | Type | Values | Description |
|---|---|---|---|
| path | string | - | Path and filename of the file containing the data pattern. |
MEASUREMENT:CLOCKRECOVERY:DATAPATH "C:/E:" sets the data path to C:/E:. MEASUREMENT:CLOCKRECOVERY:DATAPATH? might return MEASUREMENT:CLOCKRECOVERY:DATAPATH "C:/E".
Sets or queries the global nominal data bit rate used when nominal data rate clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| rate | real | - | Global value for the nominal data rate. |
MEASUREMENT:CLOCKRECOVERY:DATARATE 2.0e+9 sets the data rate for clock recovery to 2.0 GHz. MEASUREMENT:CLOCKRECOVERY:DATARATE? might return MEASUREMENT:CLOCKRECOVERY:DATARATE 2.5000E+9 indicating the data rate is 2.5 GHz.
Sets or queries the global explicit clock mode used when explicit clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | EDGE | PLL | Selects the explicit clock recovery mode. |
Sets or queries the global JTF bandwidth used when PLL clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Global clock recovery JTF bandwidth. |
MEASUREMENT:CLOCKRECOVERY:JTFBANDWIDTH 2.0e6 MEASUREMENT:CLOCKRECOVERY:JTFBANDWIDTH?
Sets or queries the global loop bandwidth used when PLL clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | The global loop bandwidth. |
MEASUREMENT:CLOCKRECOVERY:LOOPBANDWIDTH 2.0e6 sets the loop bandwidth to 2.0 MHz. MEASUREMENT:CLOCKRECOVERY:LOOPBANDWIDTH? might return MEASUREMENT:CLOCKRECOVERY:LOOPBANDWIDTH 1.0000E+6 indicating the loop bandwidth is 1.0 MHz.
Sets or queries how often the clock is calculated when constant clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FIRST | EVERY | Selects whether the clock is calculated on the first acquisition or on every acquisition. |
MEASUREMENT:CLOCKRECOVERY:MEANAUTOCALCULATE EVERY calculates the clock on every acquisition. MEASUREMENT:CLOCKRECOVERY:MEANAUTOCALCULATE? might return MEASUREMENT:CLOCKRECOVERY:MEANAUTOCALCULATE FIRST indicating the clock is calculated on the first acquisition.
Sets or queries the global clock recovery method for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | PLL | CONSTANTCLOCK | EXPLICITCLOCK | Selects the clock recovery method. |
MEASUREMENT:CLOCKRECOVERY:METHOD EXPLICITCLOCK specifies using an explicit clock. MEASUREMENT:CLOCKRECOVERY:METHOD? might return MEASUREMENT:CLOCKRECOVERY:METHOD PLL indicating the method is set to PLL.
Sets the PLL clock recovery model type. The valid model values are 1 or 2.
| Name | Type | Values | Description |
|---|---|---|---|
| TYPE<x> | integer | 1 - 2 | PLL model type to use for clock recovery. |
MEASUREMENT:CLOCKRECOVERY:MODEL TYPE2 MEASUREMENT:CLOCKRECOVERY:MODEL?
Sets or queries the global offset value used when explicit clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| offset | real | - | Global clock offset. |
MEASUREMENT:CLOCKRECOVERY:NOMINALOFFSET 1.0 MEASUREMENT:CLOCKRECOVERY:NOMINALOFFSET?
Sets or queries the global offset type used when explicit clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | AUTO | MANUAL | Selects the global offset type. |
MEASUREMENT:CLOCKRECOVERY:NOMINALOFFSET:SELECTIONTYPE AUTO MEASUREMENT:CLOCKRECOVERY:NOMINALOFFSET:SELECTIONTYPE?
Sets or queries the global communications standard used when PLL clock recovery is used for the measurement. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| standard | enum | CUSTom | ENET100 | FW1394BS400B | FW1394BS800B | FW1394BS1600B | FBD1 | FBD2 | FBD3 | FC133 | FC266 | FC531 | FC1063 | FC2125 | FC4250 | FC8500 | ENET1000 | IBA2500 | IBA_GEN2 | OC1 | OC3 | OC12 | OC48 | PCIE_GEN1 | PCIE_GEN2 | PCIE_GEN3 | RIO125 | RIO250 | RIO3125 | SAS15_NOSSC | SAS3_NOSSC | SAS6_NOSSC | SAS12_NOSSC | SAS15_SSC | SAS3_SSC | SAS6_SSC | SAS12_SSC | SATA_GEN1 | SATA_GEN2 | SATA_GEN3 | USB3 | XAUI | XAUI_GEN2 | Selects the global communications standard for PLL clock recovery. |
Sets the PLL clock recovery loop feedback time-constants so the actual transfer function matches a mathematical filter polynomial. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 1.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 1 | 0 | Turns automatic transition density compensation on or off. |
Sets or queries the model used to separate DDJ from TIE.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SPECtraldomain | TIMDomain | Selects the DDJ separation model. |
MEASUrement:DDJMethod SPECtraldomain MEASUREMENT:DDJMethod?
Deletes all the active instances of measurements defined in the scope application.
Deletes the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement | string | - | The measurement to delete; must be in the form "MEAS<NR1>" where <NR1> is greater than or equal to 1. |
MEASUREMENT:DELETE "MEAS4" deletes measurement 4.
Sets or queries the dirac model used to separate random from deterministic jitter for jitter measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| model | enum | PCIExpress | FIBREchannel | Selects the dirac model. |
MEASUREMENT:DIRACMODEL FIBRECHANNEL sets the dirac model to FIBRECHANNEL. MEASUREMENT:DIRACMODEL? might return MEASUREMENT:DIRACMODEL PCIEXPRESS indicating the dirac model is set to PCIECPRESS.
Sets or queries the display units used for jitter summary measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SEConds | UNITINtervals | Selects the display units for jitter summary measurements. |
MEASUREMENT:DISPLAYUNITS UNITINTERVALS sets the display units to unit intervals. MEASUREMENT:DISPLAYUNITS? might return MEASUREMENT:DISPLAYUNITS SECONDS indicating the display units are seconds.
Sets or queries the type of edge used for the measurement.
Sets or queries the state of period jitter analysis mode.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 1 | 0 | Selects whether period jitter analysis mode is active or off. |
MEASUREMENT:ENABLEPjitter ON activates period jitter analysis mode.
Sets or queries the global filter blanking time.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Current filter blanking time. |
Sets or queries the global high pass filter frequency for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| freq | real | Hz | Current high pass filter frequency. |
MEASUREMENT:FILTERS:HIGHPASS:FREQ 20.0e6 MEASUREMENT:FILTERS:HIGHPASS:FREQ?
Sets or queries the global high pass filter order for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| spec | enum | NONE | FIRST | SECOND | THIRD | Selects the high pass filter order or disables the high pass filter. |
MEASUREMENT:FILTERS:HIGHPASS:SPEC NONE MEASUREMENT:FILTERS:HIGHPASS:SPEC?
Sets or queries the global low pass filter frequency for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | - | The current low pass filter frequency. |
MEASUREMENT:FILTERS:LOWPASS:FREQ 20.0e6 sets the low pass frequency to 20 MHz. MEASUREMENT:FILTERS:LOWPASS:FREQ? might return MEASUREMENT:FILTERS:LOWPASS:FREQ 10.0000E+6 indicating the low pass frequency is 10.0 MHz.
Sets or queries the global low pass filter order for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NONE | FIRST | SECOND | THIRD | Global low pass filter order. |
MEASUREMENT:FILTERS:LOWPASS:SPEC SECOND MEASUREMENT:FILTERS:LOWPASS:SPEC? might return MEASUREMENT:FILTERS:LOWPASS:SPEC NONE indicating no low pass filter.
Sets or queries the global filter ramp time for the measurement.
Sets or queries the global gating type for measurements. Gating can be turned off or set to screen, cursor, logic, search, or time-based gating.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NONE | SCREEN | CURSor | LOGic | SEARch | TIMe | Global measurement gating type. |
MEASUREMENT:GATING SCREEN turns on measurement gating, using the left and right edges of the screen. MEASUREMENT:GATING? might return MEASUREMENT:GATING CURSOR, indicating that measurements are limited to the portion of the waveform between the vertical bar cursors.
Sets or queries the global gating active level used for logic gating.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Selects whether the logic gate is active high or active low. |
Sets or queries the end gate time for all measurements that use Global gating.
| Name | Type | Values | Description |
|---|---|---|---|
| endtime | real | -10000 - 10000 | Time gating end gate time in seconds. |
MEASUrement:GATing:ENDtime 5.31e-2 MEASUrement:GATing:ENDtime?
Sets or queries the global gating hysteresis value used for logic gating.
| Name | Type | Values | Description |
|---|---|---|---|
| hysteresis | real | s | The gating hysteresis. |
MEASUREMENT:GATING:HYSTERESIS 40.0e-3 MEASUREMENT:GATING:HYSTERESIS?
Sets or queries the global logic source used for measurement gating. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Logic source selection. |
MEASUREMENT:GATING:LOGICSOURCE MATH1 MEASUREMENT:GATING:LOGICSOURCE?
Sets or queries the global gating mid reference value used for logic gating.
| Name | Type | Values | Description |
|---|---|---|---|
| mid ref value | real | V | Mid reference value for gating. |
MEASUREMENT:GATING:MIDREF 2.0 MEASUREMENT:GATING:MIDREF?
Sets or queries the global gating search source when the gating type is search.
| Name | Type | Values | Description |
|---|---|---|---|
| SEARCH<x> | enum | - | Specifies the search source. |
Sets or queries the start gate time for all measurements that use Global gating.
| Name | Type | Values | Description |
|---|---|---|---|
| start gate time | real | -10000 - 10000 | Time gating start gate time in seconds. |
MEASUrement:GATing:STARTtime -1.5e-3 MEASUrement:GATing:STARTtime?
Sets or queries the global input and output configuration.
| Name | Type | Values | Description |
|---|---|---|---|
| configuration | enum | INPUT | OUTPUT | Selects the source settings configuration as input or output. |
MEASUREMENT:HIGHLEVEL:CONFIGURATION INPUT sets the source settings configuration as input. MEASUREMENT:HIGHLEVEL:CONFIGURATION? might return MEASUrement:HIGHLEVel:CONFIGuration INPUT, indicating the source settings configuration is input.
Sets or queries the global input edge qualifier source. The source can be selected from an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the source used for the global input edge qualifier. |
MEASUREMENT:HIGHLEVEL:EDGEQUALIFIER CH1 MEASUREMENT:HIGHLEVEL:EDGEQUALIFIER?
Sets or queries the global input low pass filter frequency.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | 20 Hz - 10e6 Hz | Global input low pass filter frequency. |
MEASUREMENT:HIGHLEVEL:INLOWPASS:FREQ 1e3 MEASUREMENT:HIGHLEVEL:INLOWPASS:FREQ?
Sets or queries the global input low pass filter order.
| Name | Type | Values | Description |
|---|---|---|---|
| order | enum | NONE | FIRST | SECOND | THIRD | Selects the global input low pass filter order. |
Enables or disables the Line-to-Line to Line-to-Neutral conversion.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Turns the conversion off or on. |
MEASUREMENT:HIGHLEVEL:L2LTOL2N 1 enables Line-to-Line to Line-to-Neutral Conversion. MEASUREMENT:HIGHLEVEL:L2LTOL2N? might return MEASUrement:HIGHLEVel:L2LTOL2N 0, indicating Line-to- Line to Line-to-Neutral Conversion is disabled.
Sets or queries the global input select lines.
| Name | Type | Values | Description |
|---|---|---|---|
| lines | enum | ABCB | ACBC | BACA | AN | BN | CN | Global input select lines to use. |
MEASUREMENT:HIGHLEVEL:LINESELECTED ABCB sets the global input select lines as ABCB. MEASUREMENT:HIGHLEVEL:LINESELECTED? might return MEASUrement:HIGHLEVel:LINESelected ABCB, indicating the global input select lines is ABCB.
Sets or queries the global output edge qualifier source.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the output edge qualifier source as an analog channel, math channel, or reference waveform. |
MEASUREMENT:HIGHLEVEL:OUTEDGEQUALIFIER CH1 MEASUREMENT:HIGHLEVEL:OUTEDGEQUALIFIER?
Sets or queries global output Line-to-Line to Line-to-Neutral Conversion.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Enables or disables the global output Line-to-Line to Line-to-Neutral Conversion. |
MEASUREMENT:HIGHLEVEL:OUTL2LTOL2N 1 MEASUREMENT:HIGHLEVEL:OUTL2LTOL2N?
Sets or queries the global output select lines.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | XYZY | XZYZ | YXZX | XN | YN | ZN | Selects which output lines are used. |
Sets or queries the global output low pass filter frequency.
| Name | Type | Values | Description |
|---|---|---|---|
| frequency | real | 20 Hz - 10e6 Hz | Specifies the global output low pass filter frequency. |
MEASUREMENT:HIGHLEVEL:OUTLOWPASS:FREQ 1e3 MEASUREMENT:HIGHLEVEL:OUTLOWPASS:FREQ?
Sets or queries the global output low pass filter order.
| Name | Type | Values | Description |
|---|---|---|---|
| order | enum | NONE | FIRST | SECOND | THIRD | Global output low pass filter order. |
Sets or queries the global output source for measurement high-level results. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Global output source selection. |
MEASUREMENT:HIGHLEVEL:OUTSOURCE CH1 sets the global output source as channel 1. MEASUREMENT:HIGHLEVEL:OUTSOURCE? might return MEASUrement:HIGHLEVel:OUTSOURCE CH1, indicating the global output source is channel 1.
Sets or queries the global output wiring configuration.
| Name | Type | Values | Description |
|---|---|---|---|
| wiring | enum | P1W2V1I1 | P3W3V2I2 | P3W3V3I3 | P3W3 | DCP1W2 | Global output wiring configuration. |
MEASUREMENT:HIGHLEVEL:OUTWIRING P3W3 sets the global output wiring configuration to P3W3. MEASUREMENT:HIGHLEVEL:OUTWIRING? might return MEASUrement:HIGHLEVel:OUTWIRing P3W3V3I3, indicating the global output wiring configuration is P3W3V3I3.
Sets or queries the global input source used for the high-level measurement. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the measurement input source. |
MEASUREMENT:HIGHLEVEL:SOURCE CH1 MEASUREMENT:HIGHLEVEL:SOURCE? might return MEASUrement:HIGHLEVel:SOURCE CH1, indicating the global input source is channel 1.
Sets or queries the global input source used for the measurement. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Global input source for the measurement. |
MEASUREMENT:HIGHLEVEL:SOURCE CH1 sets the global input source as channel 1. MEASUREMENT:HIGHLEVEL:SOURCE? might return MEASUrement:HIGHLEVel:SOURCE CH1, indicating the global input source is channel 1.
Sets or queries the wiring configuration for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| wiring | enum | P1W2V1I1 | P1W3V2I2 | P3W3V2I2 | P3W3V3I3 | P3W3 | DCP1W2 | Selects the measurement wiring configuration. |
MEASUREMENT:HIGHLEVEL:WIRING P3W4 sets the wiring configuration to P3W3. MEASUREMENT:HIGHLEVEL:WIRING? might return MEASUrement:HIGHLEVel:WIRing P3W3V3I3, indicating the wiring configuration is P3W3V3I3.
Sets or queries the wiring configuration for the measurement.
MEASUREMENT:HIGHLEVEL:WIRING P3W4 sets the wiring configuration to P3W3. MEASUREMENT:HIGHLEVEL:WIRING? might return MEASUrement:HIGHLEVel:WIRing P3W3V3I3, indicating the wiring configuration is P3W3V3I3.
Sets or queries the interpolation mode used to locate edge crossings.
Queries the interpolation mode used for measurements.
MEASUREMENT:INTERP? might return MEASUREMENT:INTERP AUTO indicating the interpolation mode is auto.
Sets or queries the model used to separate random from deterministic jitter for jitter measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| model | enum | SPECTRAL | SPECTRALBUJ | Selects the jitter separation model. |
Sets or queries the model used to separate random from deterministic jitter for jitter measurements.
MEASUREMENT:JITTERMODEL SPECTRAL MEASUREMENT:JITTERMODEL?
Returns a comma-separated list of all currently defined measurements. When no measurements are defined, the command returns NONE.
Sets or queries the state of RJ locking.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 1 | 0 | Turns RJ locking off or on. |
MEASUREMENT:LOCKRJ ON activates RJ locking.
Sets or queries the state of RJ locking.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 1 | 0 | Turns RJ locking off or on. |
MEASUREMENT:LOCKRJ ON activates RJ locking.
Sets or queries the RJ lock value. The allowed range is 1e-15 to 1, with a default value of 1e-12.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 1e-15 - 1 | RJ lock value. |
MEASUREMENT:LOCKRJVALUE 1 sets the lock value to the maximum value of 1. MEASUREMENT:LOCKRJVALUE? might return MEASUREMENT:LOCKRJVALUE 1.0000E-12, indicating the lock value is set to the default value of 1e-12.
Sets or queries the RJ lock value.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 1e-15 - 1 | RJ lock value to use. |
MEASUREMENT:LOCKRJVALUE 1 sets the lock value to the maximum value of 1. MEASUREMENT:LOCKRJVALUE? might return MEASUREMENT:LOCKRJVALUE 1.0000E-12, indicating the lock value is set to the default value of 1e-12.
Sets or queries the value used as the high reference level of the falling edge when the measurement ref level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number specifying which math measurement is addressed. |
Sets or queries the high reference level of the falling edge for a math waveform when the measurement reference level method is set to Absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
| <NR3> | real | V | High reference level; zero percent level when MEASUrement:IMMed:REFLevel:METHod is set to Absolute. |
MEASUrement:MATH1:REFLevels:ABSolute:FALLHigh 1.5 sets the reference level to 1.5 V. MEASUrement:MATH2:REFLevels:ABSolute:FALLHigh? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:FALLHIGH 1.0000 indicating the reference level is 1.0 V.
Sets or queries the value used as the low reference level of the falling edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
| value | real | - | The low reference level value. |
MEASUrement:MATH2:REFLevels:ABSolute:FALLLow -1.5 sets the reference level to -1.5 V. MEASUrement:MATH2:REFLevels:ABSolute:FALLLow? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:FALLLOW -1.0000 indicating the reference level is -1.0 V.
Sets or queries the value used as the low reference level of the falling edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | integer | - | Specifies the math number. |
| <NR3> | real | V | The low reference level value. |
MEASUrement:MATH2:REFLevels:ABSolute:FALLLow -1.5 MEASUrement:MATH2:REFLevels:ABSolute:FALLLow?
Sets the mid reference level used to calculate the measurement's absolute reference levels for the specified math number. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | integer | - | Specifies the math number. |
| <NR3> | real | - | The mid reference level (where 50% is equal to MID) used to calculate the mid reference level when the measurement's Ref level method is set to Absolute. |
MEASUrement:MATH2:REFLevels:ABSolute:FALLMid 0.0 sets the reference level to 0.0 V. MEASUrement:MATH2:REFLevels:ABSolute:FALLMid? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:FALLMID 0.0E+0 indicating the reference level is 0.0 V.
Sets or queries the value used as the mid reference level for a falling edge when the measurement ref level method is set to Absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the math number. |
| level | real | - | Mid reference level value used to calculate the falling-edge mid reference level. |
MEASUrement:MATH2:REFLevels:ABSolute:FALLMid 0.0 sets the reference level to 0.0 V. MEASUrement:MATH2:REFLevels:ABSolute:FALLMid? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:FALLMID 0.0E+0 indicating the reference level is 0.0 V.
Sets or queries the hysteresis value of the reference level when the measurement ref level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | - | - | Specifies the math number. |
| hysteresis | real | - | The hysteresis value used for the autoset. |
MEASUrement:MATH2:REFLevels:ABSolute:HYSTeresis 20.0E-3 sets the hysteresis to 20.0 mV. MEASUrement:MATH2:REFLevels:ABSolute:HYSTeresis? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:HYSTERESIS 30.0000E-3 indicating the hysteresis value is 30.0 mV.
Sets or queries the hysteresis value of the reference level when the measurement reference level method is set to Absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number. |
| hysteresis | real | - | Hysteresis value used for the autoset. |
MEASUrement:MATH2:REFLevels:ABSolute:HYSTeresis 20.0E-3 sets the hysteresis to 20.0 mV. MEASUrement:MATH2:REFLevels:ABSolute:HYSTeresis? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:HYSTERESIS 30.0000E-3 indicating the hysteresis value is 30.0 mV.
Sets or queries the high reference level used for the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | integer | - | Specifies the math number. |
| <NR3> | real | - | The high reference level, and is the zero percent level when MEASUrement:IMMed:REFLevel:METHod is set to Absolute. |
MEASUrement:MATH2:REFLevels:ABSolute:RISEHigh 1.5 sets the reference level to 1.5 V. MEASUrement:MATH2:REFLevels:ABSolute:RISEHigh? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000 indicating the reference level is 1.0 V.
Sets or queries the value used as the high reference level of the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
Sets or queries the low reference level used for the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number specified in the MATH<x> node. |
| level | real | V | Low reference level for the rising edge. |
MEASUrement:MATH2:REFLevels:ABSolute:RISELow -1.5 MEASUrement:MATH2:REFLevels:ABSolute:RISELow? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:RISELOW -1.0000
Sets or queries the value used as the low reference level of the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | integer | - | Specifies the math number. |
| value | real | V | The low reference level used for the rising edge when the measurement reference level method is Absolute. |
MEASUrement:MATH2:REFLevels:ABSolute:RISELow -1.5 MEASUrement:MATH2:REFLevels:ABSolute:RISELow?
Sets or queries the value used as the mid reference level of the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the math number. |
| value | real | V | The mid reference level (where 50% is equal to MID) used to calculate the mid reference level when the measurement Ref level method is set to Absolute. |
MEASUrement:MATH2:REFLevels:ABSolute:RISEMid 30.0E-3 MEASUrement:MATH2:REFLevels:ABSolute:RISEMid?
Sets or queries the value used as the mid reference level of the rising edge when the measurement reference level method is set to absolute. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number. |
MEASUrement:MATH2:REFLevels:ABSolute:RISEMid 30.0E-3 MEASUrement:MATH2:REFLevels:ABSolute:RISEMid?
Sets or queries the method used to calculate the TOP and BASE used to calculate reference levels for the measurement. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SAME | UNIQue | Specifies whether the absolute levels are set the same or can be set independently. |
MEASUrement:MATH2:REFLevels:ABSolute:TYPE UNIQUE MEASUrement:MATH2:REFLevels:ABSolute:TYPE?
Queries the absolute reference-level type for the specified math measurement. The math number is specified by x.
MEASUrement:MATH2:REFLevels:ABSolute:TYPE UNIQUE MEASUrement:MATH2:REFLevels:ABSolute:TYPE? might return MEASUREMENT:MATH2:REFLEVELS:ABSOLUTE:TYPE SAME indicating that the absolute levels are set the same.
Sets or queries the method used to calculate the TOP and BASE used to calculate reference levels for the measurement. The math number is specified by x.
MEASUrement:MATH1:REFLevels:BASETop MINMax MEASUrement:MATH1:REFLevels:BASETop?
Sets or queries the method used to calculate the TOP and BASE used to calculate reference levels for the measurement. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | - | - | Specifies the math number. |
| method | enum | AUTO | MINMax | MEANhistogram | MODEhistogram | EYEhistogram | Selects the reference level calculation method. |
MEASUrement:MATH1:REFLevels:BASETop MINMax MEASUrement:MATH1:REFLevels:BASETop?
Sets or queries the reference level method for math measurements. PERCENT calculates reference levels as a percent relative to HIGH and LOW, while ABSOLUTE sets them explicitly using the corresponding ABSolute commands.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | - | - | Specifies the math number. |
| mode | enum | PERCent | ABSolute | Selects whether reference levels are calculated as percent values or set explicitly. |
MEASUrement:MATH2:REFLevels:METHod ABSOLUTE MEASUrement:MATH2:REFLevels:METHod?
Sets or queries the reference level method for the specified math measurement. The method determines whether reference levels are calculated as a percent relative to HIGH and LOW or set explicitly.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the math number. |
MEASUrement:MATH2:REFLevels:METHod ABSOLUTE MEASUrement:MATH2:REFLevels:METHod?
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | integer | - | Specifies the math number. |
| percentage | real | % | Percentage used to calculate the high reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:FALLHigh 95 MEASUrement:MATH2:REFLevels:PERCent:FALLHigh?
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | integer | - | Specifies the math number. |
| percentage | real | % | Percentage used to calculate the high reference level for the falling edge. |
MEASUrement:MATH2:REFLevels:PERCent:FALLHigh 95 MEASUrement:MATH2:REFLevels:PERCent:FALLHigh?
Sets the percentage used to calculate the falling-edge low reference level when the measurement reference level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | integer | - | Specifies the math number. |
| NR3 | real | % | Percentage used to calculate the falling-edge low reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:FALLLow 5 MEASUrement:MATH2:REFLevels:PERCent:FALLLow? might return
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
| NR3 | real | % | Percentage where 1% is equal to BASE and 99% is equal to TOP, used to calculate the mid reference level. |
MEASUrement:MATH2:REFLevels:PERCent:FALLLow 5 MEASUrement:MATH2:REFLevels:PERCent:FALLLow?
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| math<x> | integer | - | Specifies the math number. |
| nr3 | real | % | The percentage used to calculate the mid reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:FALLMid 50 MEASUrement:MATH2:REFLevels:PERCent:FALLMid? MEASUREMENT:MATH2:REFLEVELS:PERCENT:FALLMID 50.0000
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
| NR3 | real | % | The percentage (where 50% is equal to MID) used to calculate the mid reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:FALLMid 50 MEASUrement:MATH2:REFLevels:PERCent:FALLMid?
Sets or queries the hysteresis percentage used to calculate the reference level when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
| <NR3> | real | % | The hysteresis value used for the autoset. |
MEASUrement:MATH2:REFLevels:PERCent:HYSTeresis 5 MEASUrement:MATH2:REFLevels:PERCent:HYSTeresis?
Sets or queries the percentage hysteresis used for measurement reference levels when the ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number to use. |
MEASUrement:MATH2:REFLevels:PERCent:HYSTeresis 2.5 sets the hysteresis to 2.5% of MAX. MEASUrement:MATH2:REFLevels:PERCent:HYSTeresis? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:HYSTERESIS 5.0000 indicating the hysteresis is set to 5% of MAX.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number. |
| percent | real | <NR3> | Percentage used to calculate the high reference level when the measurement ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:RISEHigh 95 sets the reference level to 95% of TOP. MEASUrement:MATH2:REFLevels:PERCent:RISEHigh? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:RISEHIGH 90.0000 indicating the reference level is set to 90% of TOP.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number. |
| percentage | real | % | Percentage used to calculate the high reference level when the measurement ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:RISEHigh 95 sets the reference level to 95% of TOP. MEASUrement:MATH2:REFLevels:PERCent:RISEHigh? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:RISEHIGH 90.0000 indicating the reference level is set to 90% of TOP.
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement ref level method is set to Percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the math number. |
| percentage | real | % | Percentage used to calculate the mid reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MATH2REFLevels:PERCent:RISELow 5 sets the reference level to 5% of TOP. MEASUrement:MATH2REFLevels:PERCent:RISELow? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:RISELOW 10.0000 indicating the reference level is set to 10% of TOP.
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number. |
| percentage | real | 1 - 99 | Percentage used to calculate the low reference level. |
MEASUrement:MATH2REFLevels:PERCent:RISELow 5 sets the reference level to 5% of TOP. MEASUrement:MATH2REFLevels:PERCent:RISELow? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:RISELOW 10.0000 indicating the reference level is set to 10% of TOP.
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math number specified by x. |
| percentage | real | % | Percentage used to calculate the mid reference level when the measurement ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:RISEMid 50 sets the reference level to 50% of TOP. MEASUrement:MATH2:REFLevels:PERCent:RISEMid? might return
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement ref level method is set to percent. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | integer | - | Specifies the math number. |
| percentage | real | % | Percentage used to calculate the mid reference level when the measurement ref level method is set to Percent. |
MEASUrement:MATH2:REFLevels:PERCent:RISEMid 50 sets the reference level to 50% of TOP. MEASUrement:MATH2:REFLevels:PERCent:RISEMid? might return MEASUREMENT:MATH2:REFLEVELS:PERCENT:RISEMID 50.0000 indicating the reference level is set to 50% of TOP.
Specifies or queries the reference level percent type for the measurement math channel. The math number is specified by x.
MEASUrement:MATH2:REFLevels:PERCent:TYPE TWENTYEIGHTY MEASUrement:MATH2:REFLevels:PERCent:TYPE?
Specifies or queries the reference level percent type for the measurement. The math number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MATH<x> | - | - | Specifies the math number. |
MEASUrement:MATH2:REFLevels:PERCent:TYPE TWENTYEIGHTY MEASUrement:MATH2:REFLevels:PERCent:TYPE?
Sets or queries the analysis bandwidth for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 | Specifies the measurement number. |
| bandwidth | real | 1.0e3 - 8.0e9 | Sets the analysis bandwidth. |
MEASUrement:MEAS2:ABANdwidth 1E+6 MEASUrement:MEAS2:ABANdwidth?
Sets or queries the analysis bandwidth for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 16 | Measurement number. |
| bandwidth | real | 1.0e3 - 8.0e9 | Analysis bandwidth. |
MEASUrement:MEAS2:ABANdwidth 1E+6 MEASUrement:MEAS2:ABANdwidth?
Sets or queries the number of adjacent channels for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 - 5 | Specifies the measurement number. |
| count | integer | 1 - 5 | Sets the number of adjacent channels. |
MEASUrement:MEAS2:ACHANnels 1 turns on 1 adjacent channel. MEASUrement:MEAS2:ACHANnels? might return MEASUREMENT:MEAS2:ACHANnels 1 indicating 1 adjacent channel is on.
Sets or queries the number of adjacent channels for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| count | integer | 1 - 5 | Sets the number of adjacent channels. |
MEASUrement:MEAS2:ACHANnels 1 turns on 1 adjacent channel. MEASUrement:MEAS2:ACHANnels? might return MEASUREMENT:MEAS2:ACHANnels 1 indicating 1 adjacent channel is on.
Sets or queries the analysis method used to compute eye width or eye height. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| method | enum | PARAmetric | HISTogram | Analysis method used to compute eye width or eye height. |
Returns the analysis method setting for the specified measurement. The result indicates whether the measurement is using parametric or histogram analysis.
MEASUrement:MEAS1:AMEThod HISTogram selects histogram analysis method for measurement 1. MEASUrement:MEAS2:AMEThod? might return MEASUREMENT:MEAS2:AMEThod HISTogram, indicating that histogram analysis method is selected for measurement 2.
Sets or queries the bin count for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| count | integer | - | Bin count. |
MEASUrement:MEAS1:BIN 2 sets the bin count to 2. MEASUrement:MEAS1:BIN? might return MEASUREMENT:MEAS1:BIN 1 indicating the bin count is 1.
Sets or queries the bin count for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | NR3 | The bin count. |
MEASUrement:MEAS1:BIN 2 MEASUrement:MEAS1:BIN?
Sets or queries the bit center as an absolute value for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| bit center | real | - | Absolute bit center value. |
MEASUrement:MEAS1:BITAbsolute 50E-12 sets the bit absolute to 50E-12 for measurement 1. MEASUrement:MEAS1:BITAbsolute? might return MEASUrement:MEAS1:BITAbsolute 50E-12, indicating the bit absolute is 50E-12 for measurement 1.
Sets or queries the bit center as an absolute value for the specified measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
MEASUrement:MEAS1:BITAbsolute 50E-12 MEASUrement:MEAS1:BITAbsolute?
Sets or queries whether the measurement returns the mean or mode statistic result when the measurement type is bit amplitude/high/low. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | MEAN | MODE | Specifies whether the measurement returns results for each bit or the mode of its results. |
MEASUrement:MEAS1:BITCfgmode MODE MEASUrement:MEAS1:BITCfgmode?
Sets or queries whether the measurement returns the mean or mode statistic result when the measurement type is bit amplitude/high/low. Measurements are specified by x.
MEASUrement:MEAS1:BITCfgmode MODE specifies that the measurement returns the mode of its results. MEASUrement:MEAS1:BITCfgmode? might return MEASUREMENT:MEAS1:BITCFGMODE MEAN indicating the configuration mode is set to MEAN.
Sets or queries the bit end as a percentage of the unit interval. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| bit end | real | % | The bit end value as a percentage of the unit interval. |
MEASUrement:MEAS2:BITEnd 60 sets the bit end to 60% of the unit interval. MEASUrement:MEAS2:BITEnd? might return MEASUREMENT:MEAS2:BITEND 50.0000 indicating the bit end is 50%.
Sets or queries the bit end as a percentage of the unit interval. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| bit end | real | - | The bit end value as a percentage of the unit interval. |
MEASUrement:MEAS2:BITEnd 60 sets the bit end to 60% of the unit interval. MEASUrement:MEAS2:BITEnd? might return MEASUREMENT:MEAS2:BITEND 50.0000 indicating the bit end is 50%.
Sets or queries the bit center percentage for the selected measurement. The value is specified as a percentage of the unit interval.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| bit center percentage | real | % | Bit center percentage value to be measured for the bit type selected. |
MEASUrement:MEAS2:BITPcnt 55 sets the bit center to 55% of the unit interval. MEASUrement:MEAS2:BITPcnt? might return MEASUREMENT:MEAS2:BITPCNT 50.0000 indicating bit center is 50% of the unit interval.
Sets or queries the bit center percentage value for the selected measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | % | Bit center percentage value to be measured for the bit type selected. |
MEASUrement:MEAS2:BITPcnt 55 MEASUrement:MEAS2:BITPcnt? might return MEASUREMENT:MEAS2:BITPCNT 50.0000
Sets or queries the bit start as a percentage of the unit interval for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| NR3 | real | % | Bit start as a percentage of the unit interval. |
MEASUrement:MEAS2:BITSTart 45 MEASUrement:MEAS2:BITSTart?
Sets or queries the bit start as a percentage of the unit interval for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| NR3 | real | % | The bit start percentage. |
MEASUrement:MEAS2:BITSTart 45 MEASUrement:MEAS2:BITSTart?
Sets or queries the bit type for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | ALLBits | TRANSition | NONTRANsition | Selects whether the measurement returns results for all bits, transition bits only, or non-transition bits only. |
Sets or queries the base measurement type for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS2:BMTYPe PERIOD MEASUrement:MEAS2:BMTYPe?
Sets or queries the base measurement type for measurement x. Measurement numbers are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| mode | enum | TIE | PERIOD | NUInterval | Sets the base measurement type. |
MEASUrement:MEAS2:BMTYPe PERIOD MEASUrement:MEAS2:BMTYPe?
Sets or queries the base measurement type for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| mode | enum | TIE | PERIOD | NUInterval | Selects the base measurement type. |
MEASUrement:MEAS2:BMTYPe PERIOD MEASUrement:MEAS2:BMTYPe?
Sets or queries the burst edge type for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| edge | enum | RISE | FALL | Specifies whether the burst uses a rising or falling edge. |
MEASUrement:MEAS2:BURSTEDGTYPe FALL MEASUrement:MEAS2:BURSTEDGTYPe? might return MEASUREMENT:MEAS2:BURSTEDGTYPE RISE indicating a burst with a rising edge.
Sets or queries the burst edge type for the measurement. Measurements are specified by x.
MEASUrement:MEAS2:BURSTEDGTYPe FALL specifies a burst with a falling edge. MEASUrement:MEAS2:BURSTEDGTYPe? might return MEASUREMENT:MEAS2:BURSTEDGTYPE RISE indicating a burst with a rising edge.
Sets or queries the bias voltage for the specified WBG measurement. Requires a WBG-DPT License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Bias voltage value for the WBG measurement. |
MEASUrement:MEAS2:BVOLTage 5.9000E+3 MEASUrement:MEAS2:BVOLTage?
Sets or queries the bias voltage for the specified WBG measurement number. Requires a WBG-DPT License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | x - x | Specifies the measurement number. |
| value | real | - | Bias voltage value for the WBG measurement. |
MEASUrement:MEAS2:BVOLTage 5.9000E+3 MEASUrement:MEAS2:BVOLTage?
Returns the maximum cycle-cycle statistic value for the specified measurement for all acquisitions. Measurements are specified by x.
MEASUrement:MEAS2:CCRESUlts:ALLAcqs:MAXimum? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:MAXIMUM 9.91E+37.
Returns the mean cycle-cycle statistic value for the specified measurement for all acquisitions.
MEASUrement:MEAS2CCRESUlts:ALLAcqs:MEAN? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:MEAN 9.91E+37.
Returns the minimum cycle-cycle statistic value for the specified measurement for all acquisitions. Measurements are specified by x.
MEASUrement:MEAS2CCRESUlts:ALLAcqs:MINimum? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:MINimum 9.91E+37.
Returns the peak-to-peak cycle-cycle statistic value for the specified measurement for all acquisitions. Measurements are specified by x.
MEASUrement:MEAS2CCRESUlts:ALLAcqs:PK2PK? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:PK2PK 9.91E+37.
Returns the population of all cycle-cycle statistics for the specified measurement accumulated over all acquisitions since statistics were last reset.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS2:CCRESUlts:ALLAcqs:POPUlation? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:POPULATION 0 indicating no statistics for the measurement.
Returns the standard deviation cycle-cycle statistic for the specified measurement accumulated over all acquisitions since statistics were last reset. Measurements are specified by x.
MEASUrement:MEAS2CCRESUlts:ALLAcqs:STDDev? might return MEASUREMENT:MEAS2:CCRESULTS:ALLACQS:STDDev 9.91E+37.
Returns the maximum cycle-cycle value for the specified measurement for the current acquisition. Measurements are specified by x.
MEASUrement:MEAS2:CCRESUlts:CURRentacq:MAXimum? might return MEASUREMENT:MEAS1:CCRESULTS:CURRENTACQ:MAXIMUM 9.91E+37.
Returns the mean cycle-cycle value for the specified measurement for the current acquisition. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS2:CCRESUlts:CURRentacq:MEAN? might return MEASUREMENT:MEAS1:CCRESULTS:CURRENTACQ:MEAN 9.91E+37.
Returns the minimum cycle-cycle value for the specified measurement for the current acquisition. Measurements are specified by x.
MEASUrement:MEAS2:CCRESUlts:CURRentacq:MINimum? might return MEASUREMENT:MEAS1:CCRESULTS:CURRENTACQ:MINimum 9.91E+37.
This query-only command returns the peak-to-peak cycle-cycle statistic for the specified measurement for the current acquisition. Measurements are specified by x.
Returns the population of the cycle-cycle statistics for the specified measurement for the current acquisition. Measurements are specified by x.
MEASUrement:MEAS1:CCRESUlts:CURRentacq:POPUlation? might return MEASUREMENT:MEAS1:CCRESULTS:CURRENTACQ:POPULATION 0
Returns the standard deviation cycle-cycle statistic value for the specified measurement for the current acquisition. Measurements are specified by x.
MEASUrement:MEAS1:CCRESUlts:CURRentacq:STDDev? might return
Sets or returns the filter count for the PSIJ measurement.
Queries the center frequency for the specified measurement center-frequency entry. The response returns the current center frequency value.
MEASUrement:MEAS1:CF1Val 2.5000E+9 MEASUrement:MEAS1:CF1Val? might return :MEASUrement:MEAS1:CF1Val 2.5000E+9 indicating the center frequency is 2.5 GHz.
Sets or queries the advanced clock recovery method used for the measurement. Measurements are specified by x.
MEASUrement:MEAS1:CLOCKRecovery:ADVanced:METHod PATTERN sets the advanced CDR method to use a Known Data Pattern. MEASUrement:MEAS1:CLOCKRecovery:ADVanced:METHod? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:ADVANCED:METHOD NONE indicating no advanced CRD method.
Sets or queries the advanced clock recovery method used for the measurement. Measurements are specified by x.
MEASUrement:MEAS1:CLOCKRecovery:ADVanced:METHod PATTERN sets the advanced CDR method to use a Known Data Pattern. MEASUrement:MEAS1:CLOCKRecovery:ADVanced:METHod? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:ADVANCED:METHOD NONE indicating no advanced CRD method.
Sets the clock frequency used for explicit clock recovery for measurement x, or queries the current frequency. MEAS<x> specifies the measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| clock frequency | real | Hz | Clock frequency value to set. |
MEASUrement:MEAS1:CLOCKRecovery:CLOCKFrequency 2.0E+9 sets the frequency to 2.0 GHz. MEASUrement:MEAS1:CLOCKRecovery:CLOCKFrequency? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:CLOCKFREQUENCY 2.5000E+9 indicating the frequency is 2.5 GHz.
Queries the clock frequency used for explicit clock recovery on measurement x. The measurement number is specified by x.
MEASUrement:MEAS1:CLOCKRecovery:CLOCKFrequency 2.0E+9 MEASUrement:MEAS1:CLOCKRecovery:CLOCKFrequency? MEASUREMENT:MEAS1:CLOCKRECOVERY:CLOCKFREQUENCY 2.5000E+9
Sets or queries the clock multiplier used when explicit clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| clock multiplier | real | - | Clock multiplier. |
MEASUrement:MEAS1:CLOCKRecovery:CLOCKMultiplier 1.5 sets the clock multiplier to 1.5. MEASUrement:MEAS1:CLOCKRecovery:CLOCKMultiplier? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:CLOCKMULTIPLIER 1.0000 indicating the clock multiplier is 1.0.
Sets or queries the clock multiplier used when explicit clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| clock multiplier | real | - | The clock multiplier. |
MEASUrement:MEAS1:CLOCKRecovery:CLOCKMultiplier 1.5 MEASUrement:MEAS1:CLOCKRecovery:CLOCKMultiplier?
Sets or queries the constant clock mode used when constant clock recovery is used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | MEAN | MEDian | FIXed | Selects the constant clock mode. |
Sets or queries the damping value used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| damping value | real | - | Clock recovery damping value. |
MEASUrement:MEAS1:CLOCKRecovery:DAMPing 700.0E-3 MEASUrement:MEAS1:CLOCKRecovery:DAMPing?
Sets or queries the damping value used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| damping value | real | - | Clock recovery damping value. |
MEASUrement:MEAS1:CLOCKRecovery:DAMPing 700.0E-3 sets the damping value to 0.70. MEASUrement:MEAS1:CLOCKRecovery:DAMPing? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:DAMPING 700.0000E-3 indicating the damping value is 0.70.
Sets or queries the file containing the data pattern used when known data pattern clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| path | string | - | File containing the data pattern to be used for known data pattern clock recovery. |
MEASUrement:MEAS1:CLOCKRecovery:DATAPath "TEST125.txt" specifies the file containing the data pattern is TEST125.txt".
Sets or queries the file containing the data pattern used when known data pattern clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| dataPath | string | - | File containing the data pattern to be used for known data pattern clock recovery. |
MEASUrement:MEAS1:CLOCKRecovery:DATAPath "TEST125.txt" specifies the file containing the data pattern is TEST125.txt.
Sets or queries the nominal data bit rate used when nominal data rate clock recovery is selected for a measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Nominal data rate. |
MEASUrement:MEAS1:CLOCKRecovery:DATARate 2.0000E+9 MEASUrement:MEAS1:CLOCKRecovery:DATARate?
Sets or queries the nominal data bit rate used when nominal data rate clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| rate | real | Hz | Nominal data rate. |
MEASUrement:MEAS1:CLOCKRecovery:DATARate 2.0000E+9 MEASUrement:MEAS1:CLOCKRecovery:DATARate? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:DATARATE 2.5000E+9
Sets or queries the explicit clock mode used when explicit clock recovery is used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | EDGE | PLL | Specifies the explicit clock mode. |
MEASUrement:MEAS1:CLOCKRecovery:EXPLICITCLOCKMODe EDGE MEASUrement:MEAS1:CLOCKRecovery:EXPLICITCLOCKMODe?
Sets or queries the explicit clock mode used when explicit clock recovery is used for the measurement. The measurement number is specified by x.
MEASUrement:MEAS1:CLOCKRecovery:EXPLICITCLOCKMODe EDGE MEASUrement:MEAS1:CLOCKRecovery:EXPLICITCLOCKMODe?
Sets or queries the clock recovery settings global flag for measurement x. Global clock recovery settings can be applied to all measurements or changed independently for each measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | OFF | ON | 0 | 1 | Selects whether clock recovery settings are changed independently per measurement or globally for all measurements. |
MEASUrement:MEAS1:CLOCKRecovery:GLOBal 1 MEASUrement:MEAS1:CLOCKRecovery:GLOBal? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:GLOBAL 0
Sets or queries the clock recovery settings global flag for measurement x. The setting applies globally to all measurements or independently per measurement.
MEASUrement:MEAS1:CLOCKRecovery:GLOBal 1 MEASUrement:MEAS1:CLOCKRecovery:GLOBal?
Sets or queries the JTF bandwidth used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| JTFBandwidth | real | - | The clock recovery JTF bandwidth. |
MEASUrement:MEAS1:CLOCKRecovery:JTFBandwidth 1.10E+6 sets the bandwidth to 1.1 MHz. MEASUrement:MEAS1:CLOCKRecovery:JTFBandwidth? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:JTFBANDWIDTH 1.0000E+6 indicating the bandwidth is 1.0 MHz.
Sets or queries the JTF bandwidth used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| bandwidth | real | - | Clock recovery JTF bandwidth. |
MEASUrement:MEAS1:CLOCKRecovery:JTFBandwidth 1.10E+6 sets the bandwidth to 1.1 MHz. MEASUrement:MEAS1:CLOCKRecovery:JTFBandwidth? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:JTFBANDWIDTH 1.0000E+6 indicating the bandwidth is 1.0 MHz.
Sets or queries the clock recovery loop bandwidth for the selected measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| bandwidth | real | - | The clock recovery loop bandwidth. |
MEASUrement:MEAS1:CLOCKRecovery:LOOPBandwidth 1.10E+6 sets the bandwidth to 1.1 Mhz. MEASUrement:MEAS1:CLOCKRecovery:LOOPBandwidth? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:LOOPBANDWIDTH 1.0000E+6 indicating the bandwidth is 1.0 MHz.
Sets or queries the clock recovery loop bandwidth for measurement x. The measurement number is specified by MEAS<x>.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| bandwidth | real | - | Clock recovery loop bandwidth. |
MEASUrement:MEAS1:CLOCKRecovery:LOOPBandwidth 1.10E+6 MEASUrement:MEAS1:CLOCKRecovery:LOOPBandwidth? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:LOOPBANDWIDTH 1.0000E+6
Sets or queries how often the clock is calculated when constant clock recovery is used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FIRST | EVERY | Selects whether the clock is calculated on the first acquisition or on every acquisition. |
MEASUrement:MEAS1:CLOCKRecovery:MEANAUTOCalculate EVERY causes the clock to be calculated on every acquisition. MEASUrement:MEAS1:CLOCKRecovery:MEANAUTOCalculate? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:MEANAUTOCALCULATE FIRST indicating the clock is calculated on the first acquisition.
Sets or queries the clock recovery method for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| method | enum | PLL | CONSTANTCLOCK | EXPLICITCLOCK | Clock recovery method to use for the measurement. |
Sets or queries the clock recovery method for the measurement. Measurements are specified by x.
Sets or queries how often the clock is calculated when constant clock recovery is used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | FIRST | EVERY | Selects whether the clock is calculated on the first acquisition or on every acquisition. |
MEASUrement:MEAS1:CLOCKRecovery:MEANAUTOCalculate EVERY causes the clock to be calculated on every acquisition. MEASUrement:MEAS1:CLOCKRecovery:MEANAUTOCalculate? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:MEANAUTOCALCULATE FIRST indicating the clock is calculated on the first acquisition.
Sets or queries the PLL clock recovery model used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| type | enum | TYPE1 | TYPE2 | Clock recovery model type. |
MEASUrement:MEAS1:CLOCKRecovery:MODel TYPE1 MEASUrement:MEAS1:CLOCKRecovery:MODel?
Sets or queries the PLL clock recovery model used when PLL clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| TYPE<x> | enum | TYPE1 | TYPE2 | Sets the clock recovery model type. |
MEASUrement:MEAS1:CLOCKRecovery:MODel TYPE1 MEASUrement:MEAS1:CLOCKRecovery:MODel?
Sets or queries the offset value used when explicit clock recovery is used for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Clock offset. |
Sets or queries the offset type used when explicit clock recovery is used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| selectiontype | enum | AUTO | MANUAL | Selects whether the offset is automatically calculated or manually set. |
MEASUrement:MEAS1:CLOCKRecovery:NOMINALOFFset:SELECTIONtype AUTO MEASUrement:MEAS1:CLOCKRecovery:NOMINALOFFset:SELECTIONtype?
Sets or queries the offset type used when explicit clock recovery is used for the measurement. The measurement number is specified by x.
Returns or sets the nominal offset used for explicit clock recovery in a measurement. The measurement number is specified by x.
MEASUrement:MEAS1:CLOCKRecovery:NOMINALOFFset? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:NOMINALOFFSET 0.0E+0 indicating the offset is 0.0 ns.
Sets or queries the communications standard used for PLL clock recovery in the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| standard | enum | CUSTom | ENET100 | FW1394BS400B | FW1394BS800B | FW1394BS1600B | FBD1 | FBD2 | FBD3 | FC133 | FC266 | FC531 | FC1063 | FC2125 | FC4250 | FC8500 | ENET1000 | IBA2500 | IBA_GEN2 | OC1 | OC3 | OC12 | OC48 | PCIE_GEN1 | PCIE_GEN2 | PCIE_GEN3 | RIO125 | RIO250 | RIO3125 | SAS15_NOSSC | SAS3_NOSSC | SAS6_NOSSC | SAS12_NOSSC | SAS15_SSC | SAS3_SSC | SAS6_SSC | SAS12_SSC | SATA_GEN1 | SATA_GEN2 | SATA_GEN3 | USB3 | XAUI | XAUI_GEN2 | Communications standard used for clock recovery. |
MEASUrement:MEAS1:CLOCKRecovery:STAndard CUSTom MEASUrement:MEAS1:CLOCKRecovery:STAndard?
Sets or queries the standard used for clock recovery measurement on the specified measurement x. The query returns the current standard.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:CLOCKRecovery:STAndard PCIE_GEN2 sets the standard to PCIE_GEN2. MEASUrement:MEAS1:CLOCKRecovery:STAndard? might return MEASUREMENT:MEAS1:CLOCKRECOVERY:STANDARD PCIE_GEN1 indicating the standard is PCIE_GEN1.
Sets the PLL clock recovery loop feedback time-constants so the transfer function matches a mathematical filter polynomial. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 0.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | 0 specifies automatic transition density compensation is off; 1 specifies it is on. |
MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation ON specifies turning on automatic transition density compensation for PLL. MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation? might return MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation 0, indicating automatic transition density compensation is off for PLL.
Sets the PLL clock recovery loop feedback time-constants so the transfer function matches a mathematical filter polynomial. This affects measurements whose :MEASUrement:MEAS<x>:CLOCKRecovery:GLOBal flag is set to 0.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Turns automatic transition density compensation off or on. |
MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation ON specifies turning on automatic transition density compensation for PLL. MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation? might return MEASUrement:MEAS1:CLOCKRecovery:TDCOMPensation 0, indicating automatic transition density compensation is off for PLL.
Sets or queries whether a filter is used for the measurement when the measurement type is AC common mode. Measurements are specified by x.
Sets or queries whether a filter is used for the measurement when the measurement type is AC common mode. Measurements are specified by x.
Sets or queries the number of sources for the measurement when the measurement type is AC common mode. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | SINGLE | DOUBLE | Selects a single source or double sources. |
MEASUrement:MEAS1:COMMONMode:SOURCEs SINGLE specifies a single source. MEASUrement:MEAS1:COMMONMode:SOURCEs? might return MEASUREMENT:MEAS1:COMMONMODE:SOURCES DOUBLE
Sets or queries the number of sources for the measurement when the measurement type is AC common mode. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | SINGLE | DOUBLE | Selects a single source or double sources. |
MEASUrement:MEAS1:COMMONMode:SOURCEs SINGLE specifies a single source. MEASUrement:MEAS1:COMMONMode:SOURCEs? might return MEASUREMENT:MEAS1:COMMONMODE:SOURCES DOUBLE
Sets or queries the Calculate Over setting for the Power Quality measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FFREQuency | AFREquencies | Selects whether Calculate Power Quality measurement is set for one frequency or for all frequencies. |
MEASUrement:MEAS1:COVer AFREQuencies sets Calculate Power Quality measurement for all frequencies. MEASUrement:MEAS1:COVer? might return MEASUrement:MEAS1:COVer AFREQuencies, indicating the Calculate Power Quality measurement is set for all frequencies.
Sets or queries the Calculate Over setting for the Power Quality measurement. Measurements are specified by x.
MEASUrement:MEAS1:COVer AFREQuencies MEASUrement:MEAS1:COVer?
Sets or queries the channel power width for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 1.0e3 - 8.0e9 | Channel power width. |
MEASUrement:MEAS2:CPWIDTh 1E+6 MEASUrement:MEAS2:CPWIDTh?
Sets or queries the channel power width for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| channel power width | real | 1.0e3 - 8.0e9 | Channel power width for the measurement. |
MEASUrement:MEAS2:CPWIDTh 1E+6 MEASUrement:MEAS2:CPWIDTh?
Sets or queries the channel spacing for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| spacing | real | 1.0e3 - 8.0e9 | Channel spacing value. |
MEASUrement:MEAS2:CSPACing 5.0e6 MEASUrement:MEAS2:CSPACing?
Sets or queries the channel spacing for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 1.0e3 - 8.0e9 | The channel spacing. |
MEASUrement:MEAS2:CSPACing 5.0e6 MEASUrement:MEAS2:CSPACing?
Sets or queries the custom limits file path for the custom harmonics standard. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| path | string | - | Custom limits file path. |
Returns the current limits file location for the specified measurement. Measurements are specified by x.
MEASUrement:MEAS1:CUSTOMLIMITSFile? might return MEASUrement:MEAS1:CUSTOMLIMITSFile <C:\MyDir\Limits.csv>, indicating the location of the Limits.csv file.
Sets or queries the cycle mode for the specified measurement. Measurements are specified by x.
MEASUrement:MEAS1:CYCLemode CYCLE MEASUrement:MEAS1:CYCLemode?
Sets or queries the cycle mode for the selected measurement. Measurements are specified by x.
MEASUrement:MEAS1:CYCLemode CYCLE MEASUrement:MEAS1:CYCLemode? might return MEASUREMENT:MEAS1:CYCLEMODE RECORD indicating the measurement is taken over the whole record.
Sets or queries the dB down value for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | -80 - -1 | dB down value for the measurement. |
Sets or queries the dB down value for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| dB down value | real | -80 - -1 | Sets the dB down value. |
Sets or queries the 'to edge' type when EDGE<x> is EDGE1 and the 'from edge' type when EDGE<x> is EDG2, for delay measurements. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| edge | enum | FALL | RISe | BOTH | SAMEas | OPPositeas | Selects the edge type used for the delay measurement. |
MEASUREMENT:MEAS3:DELAY:EDGE2 RISE specifies that the rising edge of the waveform be used for measurement 3. MEASUREMENT:MEAS1:DELAY:EDGE2? might return MEASUREMENT:MEAS1:DELAY:EDGE2 FALL, indicating that the falling edge of the waveform is being used for measurement 1.
Sets or queries the edge type used for delay measurements, selecting the 'to edge' for EDGE1 and the 'from edge' for EDGE2. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FALL | RISe | BOTH | SAMEas | OPPositeas | Selects the edge type used for the delay measurement. |
MEASUREMENT:MEAS3:DELAY:EDGE2 RISE MEASUREMENT:MEAS1:DELAY:EDGE2? might return MEASUREMENT:MEAS1:DELAY:EDGE2 FALL, indicating that the falling edge of the waveform is being used for measurement 1.
Turns display of statistics in measurement badges on or off for the specified measurement. Basic statistics are computed regardless of this setting.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Specifies the measurement number. |
| state | enum | OFF | ON | <NR1> | Turns statistics display off or on. |
Turns the display of statistics in the measurement badge on or off for measurement x.
MEASUrement:MEAS<x>:DISPlaystat:ENABle 0 turns off the display of statistics in the measurement badge. MEASUrement:MEAS<x>:DISPlaystat:ENABle? might return MEASUREMENT:MEAS1:DISPLAYSTAT:ENABLE 1
Sets or returns the deskew method for WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Measurement number. |
| method | enum | AUTO | MANual | Deskew method set for WBG measurement. |
MEASUrement:MEAS1:DMEThod MANual sets the deskew method for WBG measurement 1. MEASUrement:MEAS1:DMEThod? might return :MEASUrement:MEAS1:DMEThod MANual indicating the manual deskew method is set for WBG measurement 1.
Sets or returns the deskew method for WBG measurement.
MEASUrement:MEAS1:DMEThod MANual sets the deskew method for WBG measurement 1. MEASUrement:MEAS1:DMEThod? might return :MEASUrement:MEAS1:DMEThod MANual indicating the manual deskew method is set for WBG measurement 1.
Enables or disables the display state of the derived Vds waveform for RDS(on) measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | OFF disables the derived Vds waveform display; ON enables it. |
MEASUrement:MEAS1:DVDS ON enables derived Vds waveform for RDS(on) measurement.
Enables or disables the display state of the derived Vds waveform for RDS(on) measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | Turns derived Vds waveform display off or on for the selected measurement. |
MEASUrement:MEAS1:DVDS ON enables derived Vds waveform for RDS(on) measurement.
Sets or queries the type of the specified edge, rise or fall, for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| edge | enum | RISE | FALL | BOTH | Specifies whether the edge is rising, falling, or either rising or falling. |
MEASUREMENT:MEAS2:EDGE1 RISE sets edge 1 of measurement 2 as the rising edge. MEASUREMENT:MEAS2:EDGE1? might return MEASUREMENT:MEAS2:EDGE1 RISE indicating that edge 1 of measurement 2 is the rising edge.
Sets or queries the type of the specified edge for the measurement, where x identifies the measurement number. The edge can be rising, falling, or either.
MEASUREMENT:MEAS2:EDGE1? might return MEASUREMENT:MEAS2:EDGE1 RISE indicating that edge 1 of measurement 2 is the rising edge.
Sets or queries the edge increment value for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| edge increment value | real | - | The measurement's edge increment value. |
MEASUREMENT:MEAS2:EDGEINCRE? might return MEASUREMENT:MEAS2:EDGEINCRE 1.0000 indicating the edge increment value is set to 1.0000.
Sets or queries the edge increment value for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| edge increment value | real | - | The measurement's edge increment value. |
MEASUREMENT:MEAS2:EDGEINCRE? might return MEASUREMENT:MEAS2:EDGEINCRE 1.0000 indicating the edge increment value is set to 1.0000.
Sets or queries the measurement edge qualifier one source for Efficiency measurements. The source is specified as a string value such as Vac.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Specifies the edge qualifier source at input configuration. |
MEASUrement:MEAS1:EDGEQUALONE Vac MEASUrement:MEAS1:EDGEQUALONE?
Sets or queries the measurement edge qualifier one source for Efficiency measurement at input configuration.
MEASUrement:MEAS1:EDGEQUALONE Vac sets the edge qualifier source for measurement 1 to Vac at input configuration. MEASUrement:MEAS1:EDGEQUALONE? might return Vac, indicating that the edge qualifier source for measurement 1 is Vac at input configuration.
Sets the measurement output edge qualifier two source for Efficiency measurement. The command takes a string source name.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Specifies the edge qualifier source at output configuration. |
Sets or queries the edge qualifier source for the specified measurement. The source can be a channel, math waveform, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Edge qualifier source for the measurement. |
MEASUrement:MEAS1:EDGEQUALifier CH4 MEASUrement:MEAS3:EDGEQUALifier?
Queries the edge qualifier source for a measurement. The source can be a channel, math waveform, or reference waveform, or UNDEFINED if none is set.
MEASUrement:MEAS1:EDGEQUALifier CH4 MEASUrement:MEAS3:EDGEQUALifier?
Sets or queries the edge qualifier source at output configuration for the specified measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:EDGEQUALTWO Vxz sets the edge qualifier source for measurement 1 to Vxz at output configuration. MEASUrement:MEAS1:EDGEQUALTWO? might return Vxz, indicating that the edge qualifier source for measurement 1 is Vxz at output configuration.
Sets or queries the 'from level' edge for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| level | enum | MID | LOW | HIGH | The edge level to use for the measurement. |
MEASUrement:MEAS1:EDGES:FROMLevel HIGH MEASUrement:MEAS1:EDGES:FROMLevel?
Sets or queries the 'from level' edge for the measurement. Measurements are specified by x.
MEASUrement:MEAS1:EDGES:FROMLevel HIGH set the from level to the high level MEASUrement:MEAS1:EDGES:FROMLevel? might return MEASUREMENT:MEAS1:EDGES:FROMLEVEL LOW indicating the from level is the low level.
Sets or queries the level type for the 'time outside level' measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| level | enum | HIGH | LOW | BOTH | Selects the level type for the measurement. |
MEASUrement:MEAS1:EDGES:LEVel HIGH MEASUrement:MEAS1:EDGES:LEVel?
Sets or queries the level type for the time outside level measurement. Measurements are specified by x.
Sets or queries the lower frequency for the measurement when the measurement type is phase noise. Lower frequencies are ignored.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| lower frequency | real | - | The lower frequency of the edge. |
MEASUrement:MEAS1:EDGES:LOWERFREQuency 1.0e3 sets the lower frequency to 1 kHz. MEASUrement:MEAS1:EDGES:LOWERFREQuency? might return MEASUREMENT:MEAS1:EDGES:LOWERFREQUENCY 0.0E+0 indicating the lower frequency is set to 0.0 Hertz.
Sets or queries the lower frequency for the measurement when the measurement type is phase noise. Lower frequencies are ignored.
Sets or queries the number of accumulation cycles for the measurement when the measurement type is nperiod. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| count | real | - | Maximum number of edges used by the measurement. |
measurement:meas1:edges:n 2 sets the number of edges to 2. measurement:meas1:edges:n? might return MEASUREMENT:MEAS1:EDGES:N 6.0000.
Sets or queries the number of accumulation cycles for the measurement when the measurement type is nperiod. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| count | real | - | Maximum number of edges used by the measurement. |
measurement:meas1:edges:n 2 measurement:meas1:edges:n?
Sets or queries the slew rate method for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| method | enum | NOMinal | DDR | Selects the slew rate method. |
MEASUrement:MEAS1:EDGES:SLEWRATEMethod NOMINAL MEASUrement:MEAS1:EDGES:SLEWRATEMethod?
Sets or queries the slew rate method for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NOMinal | DDR | Selects the slew rate method. |
MEASUrement:MEAS1:EDGES:SLEWRATEMethod NOMINAL specifies the nominal slew rate method. MEASUrement:MEAS1:EDGES:SLEWRATEMethod? might return MEASUREMENT:MEAS1:EDGES:SLEWRATEMETHOD NOMINAL indicating the slew rate method is set to NOMINAL.
Sets or queries the 'to level' edge for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| level | enum | HIGH | MID | LOW | Selects the to level edge for the measurement. |
MEASUrement:MEAS1:EDGES:TOLevel HIGH MEASUrement:MEAS1:EDGES:TOLevel?
Sets or queries the 'to level' edge for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:EDGES:TOLevel HIGH MEASUrement:MEAS1:EDGES:TOLevel?
Sets or queries the upper frequency for an edge measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | MHz | The upper frequency of the edge. |
MEASUrement:MEAS1:EDGES:UPPERFREQuency 1.5 sets the upper frequency to 1.5 MHz. MEASUrement:MEAS1:EDGES:UPPERFREQuency? might return MEASUREMENT:MEAS1:EDGES:UPPERFREQUENCY 1.0000E+6 indicating the upper frequency is 1.0 MHz.
Returns the upper frequency setting for the selected edge measurement.
MEASUrement:MEAS1:EDGES:UPPERFREQuency? might return MEASUREMENT:MEAS1:EDGES:UPPERFREQUENCY 1.0000E+6 indicating the upper frequency is 1.0 MHz.
Turns edge qualifier settings on or off as input waveform to the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the edge qualifier settings on or off. |
MEASUrement:MEAS1:EEQual ON MEASUrement:MEAS1:EEQual? might return MEASUrement:MEAS1:EEQual OFF, indicating the edge qualifier settings is off.
Turns the edge qualifier setting on or off as input waveform to the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns the edge qualifier settings on or off. |
MEASUrement:MEAS1:EEQual ON MEASUrement:MEAS1:EEQual? might return MEASUrement:MEAS1:EEQual OFF, indicating the edge qualifier settings is off.
Sets or returns the effective inductance for WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
Sets or returns the effective inductance value for the selected WBG measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Effective inductance value for the WBG measurement. |
MEASUrement:MEAS2:EINDuctance 1.0000 MEASUrement:MEAS2:EINDuctance? might return MEASUREMENT:MEAS2:EINDuctance 1.0000
Returns the number of measurement failures, if applicable, for the selected measurement. The measurement number is specified by x.
Sets or returns the filter count for PSIJ measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| count | integer | - | Specifies the number of filters applied for PSIJ measurement. |
MEASUrement:MEAS1:FCOunt 10 sets the number of filters to 10. MEASUrement:MEAS1:FCOunt? might return :MEASUrement:MEAS1:FCOunt 10, indicating the filter count is 10.
Sets or returns the filter count for PSIJ measurement. Requires the DPM option.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Measurement number specified by x. |
| count | real | - | Number of filters applied for the PSIJ measurement. |
MEASUrement:MEAS1:FCOunt 10 sets the number of filters to 10. MEASUrement:MEAS1:FCOunt? might return :MEASUrement:MEAS1:FCOunt 10, indicating the filter count is 10.
Sets or queries the harmonics filter range from order for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| value | integer | - | Specifies the filter range from value. |
MEASUrement:MEAS1:FILTERRANGEFROM 4 sets filter range from value for measurement 1 to 4. MEASUrement:MEAS1:FILTERRANGEFROM? might return MEASUrement:MEAS1:FILTERRANGEFROM 3, indicating the filter range from value is 3.
Sets or queries the harmonics filter range-from order for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| value | integer | - | Filter range from value. |
MEASUrement:MEAS1:FILTERRANGEFROM 4 MEASUrement:MEAS1:FILTERRANGEFROM?
Sets or queries the harmonics filter to order for measurement x. Measurement numbers are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| value | integer | NR3 | Filter range to value. |
MEASUrement:MEAS1:FILTERRANGETO 50 sets filter range to value for measurement 1 to 50.
Sets or queries the harmonics filter to order for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | integer | <NR3> | Specifies the filter range to value. |
MEASUrement:MEAS1:FILTERRANGETO 50 sets filter range to value for measurement 1 to 50.
Sets or queries the filter blanking time for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Current filter blanking time. |
MEASUrement:MEAS1:FILTers:BLANKingtime 3.5 MEASUrement:MEAS1:FILTers:BLANKingtime?
Sets or queries the filter blanking time for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Current filter blanking time. |
MEASUrement:MEAS1:FILTers:BLANKingtime 3.5 MEASUrement:MEAS1:FILTers:BLANKingtime?
Sets or queries the global flag for filter settings for the specified measurement. OFF/0 changes filter settings independently for each measurement; ON/1 applies global filter settings to all measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Global filter-setting mode. |
MEASUrement:MEAS<x>:FILTers:GLOBal OFF MEASUrement:MEAS<x>:FILTers:GLOBal?
Sets or queries the global flag for measurement filter settings. When enabled, filter settings apply globally to all measurements; when disabled, they are changed independently for each measurement.
Sets or queries the high pass filter frequency for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| frequency | real | - | Current high pass filter frequency. |
MEASUrement:MEAS1:FILTers:HIGHPass:FREQ 15.0E+6 MEASUrement:MEAS1:FILTers:HIGHPass:FREQ? might return MEASUREMENT:MEAS1:FILTERS:HIGHPASS:FREQ 10.0000E+6
Sets or queries the high pass filter frequency for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:FILTers:HIGHPass:FREQ 15.0E+6 sets the high pass frequency to 15.0 MHz. MEASUrement:MEAS1:FILTers:HIGHPass:FREQ? might return MEASUREMENT:MEAS1:FILTERS:HIGHPASS:FREQ 10.0000E+6 indicating the high pass frequency is set to 10.0 MHz.
Sets or queries the high pass filter order for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| order | enum | NONE | FIRST | SECOND | THIRD | Selects the high pass filter order. |
MEASUrement:MEAS1:FILTers:HIGHPass:SPEC FIRST specifies a first-order filter. MEASUrement:MEAS1:FILTers:HIGHPass:SPEC? might return MEASUREMENT:MEAS1:FILTERS:HIGHPASS:SPEC NONE indicating no high pass filter is used.
Sets or queries the high pass filter order for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| order | enum | NONE | FIRST | SECOND | THIRD | Selects the high pass filter order. |
MEASUrement:MEAS1:FILTers:HIGHPass:SPEC FIRST specifies a first-order filter. MEASUrement:MEAS1:FILTers:HIGHPass:SPEC? might return MEASUREMENT:MEAS1:FILTERS:HIGHPASS:SPEC NONE indicating no high pass filter is used.
Sets or queries the low pass filter frequency for the specified measurement. The argument range is 20 Hz to 10e6 Hz.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| frequency | real | 20 - 10e6 | Current low pass filter frequency. |
MEASUrement:MEAS1:FILTers:LOWPass:FREQ 5.0E+6 sets the low pass frequency to 5.0 MHz. MEASUrement:MEAS1:FILTers:LOWPass:FREQ? might return MEASUREMENT:MEAS1:FILTERS:LOWPASS:FREQ 10.0000E+6 indicating the low pass frequency is 10.0 MHz.
Sets or queries the low pass filter frequency for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| frequency | real | 20 Hz - 10e6 Hz | Current low pass filter frequency. |
MEASUrement:MEAS1:FILTers:LOWPass:FREQ 5.0E+6 MEASUrement:MEAS1:FILTers:LOWPass:FREQ? might return MEASUREMENT:MEAS1:FILTERS:LOWPASS:FREQ 10.0000E+6
Sets or queries the low pass filter order for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NONE | FIRST | SECOND | THIRD | Selects the low pass filter order: none, first, second, or third order. |
MEASUrement:MEAS1:FILTers:LOWPass:SPEC FIRST specifies a first-order filter. MEASUrement:MEAS1:FILTers:LOWPass:SPEC? might return MEASUREMENT:MEAS1:FILTERS:LOWPASS:SPEC NONE indicating no low pass filter is used.
Sets or queries the low pass filter order for the measurement. Measurements are specified by x.
Sets the current filter ramp time for the selected measurement. The query returns the current filter ramp time.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | 1 - 6 | Specifies the measurement number. |
| ramp time | real | - | Sets the filter ramp time. |
MEASUrement:MEAS1:FILTers:RAMPtime 1.5 sets the ramp time to 1.5. MEASUrement:MEAS1:FILTers:RAMPtime? might return MEASUREMENT:MEAS1:FILTERS:RAMPTIME 2.0000
Returns the current filter ramp time for the specified measurement filter. The example query response shows the ramp time as a numeric value.
MEASUrement:MEAS1:FILTers:RAMPtime? might return MEASUREMENT:MEAS1:FILTERS:RAMPTIME 2.0000
Sets or returns the differential filter order for WBG measurement. Requires a WBG-DPT License.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Specifies the differential filter order of the WBG measurement. |
MEASUrement:MEAS2:FORDer 1.0000 specifies the differential filter order as 1 for measurement 2. MEASUrement:MEAS2:FORDer? might return MEASUREMENT:MEAS2:FORDer 1.0000 indicating the differential filter order is 1 for measurement 2.
Sets or returns the differential filter order for WBG measurement. Requires a WBG-DPT License.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Specifies the differential filter order of the WBG measurement. |
MEASUrement:MEAS2:FORDer 1.0000 MEASUrement:MEAS2:FORDer? might return MEASUREMENT:MEAS2:FORDer 1.0000
Sets or queries the roll off factor for the RRC filter in the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | 0.001 - 1.0 | Sets the roll off factor. |
MEASUrement:MEAS1:FPARAmeter 0.22 sets the roll off factor to 0.22.
Sets or queries the roll off factor for the RRC filter in the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Measurement number. |
| factor | real | 0.001 - 1.0 | Roll off factor for the RRC filter. |
MEASUrement:MEAS1:FPARAmeter 0.22 sets the roll off factor to 0.22.
Sets or queries the switching frequency for Switching Ripple measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| freq | real | 50 Hz - 1 GHz | Switching frequency for the measurement. |
MEASUrement:MEAS1:FREQ 50k MEASUrement:MEAS1:FREQ?
Sets or queries the switching frequency for Switching Ripple measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| frequency | real | 50 Hz - 1 GHz | Switching frequency. |
MEASUrement:MEAS1:FREQ 50k MEASUrement:MEAS1:FREQ? might return MEASUrement:MEAS1:FREQ 100k, indicating the switching frequency is 100 kHz.
Sets or queries the from edge type for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | RISe | FALL | BOTH | Selects the edge type used for the measurement. |
MEASUrement:MEAS1:FROMedge RISE specifies the rising edge of the waveform. MEASUrement:MEAS1:FROMedge? might return MEASUREMENT:MEAS1:FROMEDGE BOTH indicating both the rising and falling edges of the waveform.
Sets or queries the from-edge type for the measurement specified by x.
MEASUrement:MEAS1:FROMedge RISE specifies the rising edge of the waveform. MEASUrement:MEAS1:FROMedge? might return MEASUREMENT:MEAS1:FROMEDGE BOTH indicating both the rising and falling edges of the waveform.
Sets or queries the search direction used from the edge for the specified measurement. The query returns the current direction setting.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 6 | Measurement number. |
| direction | enum | FORWard | BACKWard | Search direction from the edge. |
MEASUrement:MEAS1:FROMEDGESEARCHDIRect BACKWard MEASUrement:MEAS1:FROMEDGESEARCHDIRect? might return MEASUREMENT:MEAS1:FROMEDGESEARCHDIRECT FORWARD indicating a forward search from the edge.
Sets or queries the direct search direction from the edge for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | FORWard | BACKWard | Specifies whether the search is forward or backward from the edge. |
MEASUrement:MEAS1:FROMEDGESEARCHDIRect BACKWard MEASUrement:MEAS1:FROMEDGESEARCHDIRect? might return MEASUREMENT:MEAS1:FROMEDGESEARCHDIRECT FORWARD indicating a forward search from the edge.
Sets or queries the DDR digital measurement logic 1 source From symbol. Requires option 6-DBDDR3 and a 6 Series MSO instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | H | L | X | Sets the logic source 1 From Symbol to H (High), L (Low), or X (Don't care). |
MEASUrement:MEAS1:FROMSymbol:LOGIC2SOUrce H MEASUrement:MEAS1:FROMSymbol:LOGIC2SOUrce?
Sets or queries the DDR digital measurement logic 2 source From symbol. Requires option 6-DBDDR3 and a 6 Series MSO instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | H | L | X | Sets the logic source 2 From Symbol to H (High), L (Low), or X (Don’t care). |
MEASUrement:MEAS1:FROMSymbol:LOGIC3SOUrce H MEASUrement:MEAS1:FROMSymbol:LOGIC3SOUrce?
Sets or queries the FromSymbol MeasureAT value for measurement x. Requires option 6-DBDDR3 and a 6 Series MSO instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | Start | Stop | ClockEdge | Selects the FromSymbol MeasureAT setting. |
MEASUrement:MEAS1:FROMSymbol:MEASUREAT Start MEASUrement:MEAS1:FROMSymbol:MEASUREAT?
Sets or returns whether the RRC filter is enabled for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | True | False | Enables or disables the RRC filter. |
MEASUrement:MEAS2:FTYPe True MEASUrement:MEAS2:FTYPe?
Sets or queries the fundamental current value for IEC-Class C type harmonics standard. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| current | real | - | Fundamental current for class C harmonics standard. |
MEASUrement:MEAS1:FUNDCURRent 16.0000 MEASUrement:MEAS1:FUNDCURRent?
Sets or queries the gating type for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | NONE | SCREEN | CURSor | LOGic | SEARch | TIMe | Gating type for the measurement. |
MEASUrement:MEAS1:GATing CURSOR limits measurements to the portion of the waveform between the vertical bar cursor.
Sets or queries the gating active level when the gating type is logic. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | HIGH | LOW | Logic gating active level. |
MEASUrement:MEAS1:GATing:ACTive LOW MEASUrement:MEAS1:GATing:ACTive?
Sets or queries the end gate time for the measurement when using Local gating. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| time | real | -10000 - 10000 | Time gating end gate time in seconds. |
MEASUrement:MEAS4:GATing:ENDtime 5.31e-2 MEASUrement:MEAS6:GATing:ENDtime?
Sets or queries whether gate settings are global or independent for each measurement. Measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | OFF | ON | 0 | 1 | Controls whether gate settings are independent per measurement or applied globally to all measurements. |
MEASUrement:MEAS1:GATing:GLOBal OFF MEASUrement:MEAS1:GATing:GLOBal?
Sets or queries the gating hysteresis value when the gating type is logic. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| hysteresis | real | - | Gating hysteresis value. |
MEASUrement:MEAS1:GATing:HYSTeresis 25.0E-3 MEASUrement:MEAS1:GATing:HYSTeresis?
Sets the gating logic source for a specified measurement. The source can be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Gating logic source. |
MEASUrement:MEAS1:GATing:LOGICSource CH3 MEASUrement:MEAS1:GATing:LOGICSource? might return MEASUREMENT:MEAS1:GATING:LOGICSOURCE CH2
Sets or queries the gating mid ref value when the gating type is logic. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| midref | real | - | Mid ref value for gating. |
MEASUrement:MEAS1:GATing:MIDRef 1.0E+0 MEASUrement:MEAS1:GATing:MIDRef? might return MEASUREMENT:MEAS1:GATING:MIDREF 0.0E+0 indicating the midref value is set to 0.0.
Sets or queries the gating search source when the gating type is search. The measurement number is specified by x.
Sets or queries the start gate time for the measurement when using Local gating.
| Name | Type | Values | Description |
|---|---|---|---|
| start gate time | real | -10000 - 10000 | The time gating start gate time in seconds. |
MEASUrement:MEAS1:GATing:STARTtime -1.5e-3 sets the local start gate time for Meas 1 to -1.5 ms. MEASUrement:MEAS1:GATing:STARTtime? might return 3.0e-9, indicating that the local start gate time for Meas 1 is 3 ns.
Sets or queries the reference levels global flag for the specified measurement. OFF/0 allows reference levels to be set separately for each measurement, and ON/1 applies the same reference levels to all measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Global reference-level flag state. |
Sets or queries the class type for the harmonics measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement | integer | - | Measurement number specified by x. |
| class | enum | CLASSA | CLASSB | CLASSC | CLASSD | Class type to set for the harmonics measurement. |
MEASUrement:MEAS1:HARMONICSCLass CLASSC MEASUrement:MEAS1:HARMONICSCLass?
Sets or queries the harmonics source for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CURRENT | VOLTAGE | Harmonics source to use. |
MEASUrement:MEAS1:HARMONICSSOURce CURRENT sets the harmonics source for measurement 1 as current. MEASUrement:MEAS1:HARMONICSSOURce? might return MEASUrement:MEAS1:HARMONICSSOURce VOLTAGE, indicating the harmonics source as voltage.
Sets or queries the harmonics standard for measurement x. The measurement is specified by x, and the standard may be NONE, IEC, IEEE519, CUSTOM, or REVIEEE5192022.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| standard | enum | NONE | IEC | IEEE519 | CUSTOM | REVIEEE5192022 | Selects the harmonics test standard. |
MEASUrement:MEAS1:HARMONICSStd IEC MEASUrement:MEAS1:HARMONICSStd?
Sets or queries the harmonics units for measurement x. The units can be logarithmic or linear.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LOGARITHM | LINEAR | Harmonics units selection. |
MEASUrement:MEAS1:HARMONICSUNits LINEAR MEASUrement:MEAS1:HARMONICSUNits?
Sets or queries the local input or output source settings for a measurement. The query returns the current setting.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | INPUT | OUTPUT | Selects whether the local Input or Output source settings are treated as input or output. |
MEASUrement:MEAS1:HIGHLEVel:CONFIGuration INPUT MEASUrement:MEAS1:HIGHLEVel:CONFIGuration? might return
Sets or queries local input Line-to-Line to Line-to-Neutral Conversion for the selected measurement. A value of 1 enables the conversion and 0 disables it.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | 0 | 1 | Enables or disables local input Line-to-Line to Line-to-Neutral Conversion. |
MEASUrement:MEAS1:HIGHLEVel:L2LTOL2N 1 enables local input Line-to-Line to Line-to-Neutral Conversion. MEASUrement:MEAS1:HIGHLEVel:L2LTOL2N? might return MEASUrement:HIGHLEVel:L2LTOL2N 0, indicating local input Line-to-Line to Line-to-Neutral Conversion is disabled.
Sets or queries the local input select lines.
| Name | Type | Values | Description |
|---|---|---|---|
| line | enum | ABCB | ACBC | BACA | AN | BN | CN | Selects the local input line configuration. |
Sets or queries local output Line-to-Line to Line-to-Neutral Conversion. A value of 1 enables the conversion, and 0 disables it.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Enables or disables local output Line-to-Line to Line-to-Neutral Conversion. |
MEASUrement:MEAS?:HIGHLEVel:OUTL2LTOL2N 1 MEASUrement:MEAS?:HIGHLEVel:OUTL2LTOL2N? might return MEASUrement:MEAS?:HIGHLEVel:OUTL2LTOL2N 0, indicating local output Line-to-Line to Line-to-Neutral Conversion is disabled.
Sets or queries the local output select lines.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | XYZY | XZYZ | YXZX | XN | YN | ZN | Selects the local output select lines. |
MEASUrement:MEAS?:HIGHLEVel:OUTLINESelected XYZY MEASUrement:MEAS?:HIGHLEVel:OUTLINESelected? might return MEASUrement:MEAS?:HIGHLEVel:OUTLINESelected XYZY, indicating the local output select lines is XYZY.
Sets or queries the local output wiring for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| wiring | enum | P1W2V1I1 | P1W3V2I2 | P3W3V3I3 | P3W4 | DCP1W2 | Selects the local output wiring. |
MEASUrement:MEAS1:HIGHLEVel:OUTWIRing P1W2V1I1 MEASUrement:MEAS1:HIGHLEVel:OUTWIRing? might return MEASUrement:MEAS1:HIGHLEVel:OUTWIRing P1W2V1I1, indicating the local output wiring is configured as P1W2V1I1.
Sets or queries whether the IMDA source settings are global or local.
Sets or queries the local input wiring for the specified measurement. The measurement number is given by x.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Specifies the measurement number. |
| wiring | enum | P1W2V1I1 | P1W3V2I2 | P3W3V2I2 | P3W3V3I3 | P3W3 | DCP1W2 | Selects the local input wiring. |
MEASUrement:MEAS1:HIGHLEVel:WIRing P1W2V1I1 sets the local input wiring for measurement 1 as P1W2V1I1. MEASUrement:MEAS1:HIGHLEVel:WIRing? might return MEASUrement:MEAS1:HIGHLEVel:WIRing P1W2V1I1, indicating the local input wiring is configured as P1W2V1I1.
Sets or queries the high reference voltage value for the "time outside level" measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | High reference voltage value. |
Turns the output global settings for a measurement on or off. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Sets the output global settings for the measurement. |
MEASUrement:MEAS1:HLEVel:OUTPut:UGLobal ON MEASUrement:MEAS1:HLEVel:OUTPut:UGLobal?
Sets or queries the measurement High Torque value for the selected measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR1> | integer | 11 - 10000000 | Specifies the High Torque value of the measurement. |
Sets or queries the High Voltage value for a specified measurement. Requires the IMDA-MECH license on MSO 5, 6, and 6B series instruments.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| voltage | real | 1 - 100 | High Voltage value of the measurement. |
MEASUrement:MEAS1:HVOLtage 15.2 sets the High Voltage value for measurement 1 to 15.2. MEASUrement:MEAS1:HVOLtage? might return MEASUrement:MEAS1:HVOLtage 15.2, indicating the High Voltage value for measurement 1 is 15.2.
Sets or queries the idle time for the measurement when the measurement type is burst width. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| idle time | real | - | Specifies the idle time. |
MEASUrement:MEAS1:IDLETime 40.0E-6 sets the idle time to 40.0 μs. MEASUrement:MEAS1:IDLETime? might return MEASUREMENT:MEAS1:IDLETIME 50.0000E-6 indicating the idle time is 50.0 μs.
Sets or queries the input trigger voltage level for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Measurement number. |
| level | real | -500 - +500 | Trigger voltage level. |
MEASUrement:MEAS1:INPUTLEVel 60 MEASUrement:MEAS3:INPUTLEVel?
Sets or queries the input power value for IEC-Class C and Class D harmonics standard.
| Name | Type | Values | Description |
|---|---|---|---|
| power | real | W | Specifies the input power value for class C harmonics standard. |
MEASUrement:MEAS1:INPUTPOwer 100W MEASUrement:MEAS1:INPUTPOwer?
Sets or queries whether DCD is included in the jitter summary for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
Sets or queries whether DDJ is included in the jitter summary for the specified measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| state | enum | 0 | 1 | 1 adds the DDJ measurement as part of the jitter summary; 0 does not add it. |
MEASUrement:MEAS4:JITTERSummary:DDJ 0 MEASUrement:MEAS4:JITTERSummary:DDJ? might return MEASUREMENT:MEAS4:JITTERSUMMARY:DDJ 1
Sets or queries whether DJ is included in the jitter summary for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS4:JITTERSummary:DJ 0 MEASUrement:MEAS4:JITTERSummary:DJ?
Sets or queries whether DJ-dd is included in the jitter summary for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | x - x | Measurement number specified by x. |
| state | enum | 0 | 1 | 0 do not add the DJDD measurement as part of jitter summary; 1 add the DJDD measurement as part of jitter summary. |
MEASUrement:MEAS4:JITTERSummary:DJDD 0 specifies the DJDD measurement is not part of the jitter summary. MEASUrement:MEAS4:JITTERSummary:DJDD? might return MEASUREMENT:MEAS4:JITTERSUMMARY:DJDD 1 indicating the DJDD measurement is part of the jitter summary.
Sets or queries whether DR is included in the jitter summary for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Adds or does not add the DR measurement as part of the jitter summary. |
MEASUrement:MEAS4:JITTERSummary:DR 0 specifies that the DR measurement is not part of the jitter summary.
Sets or queries whether EyeWidth@BER is included in the jitter summary for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | 1 adds the EyeWidth@BER measurement as part of the jitter summary; 0 does not add it. |
MEASUrement:MEAS4:JITTERSummary:EYEWIDTHBER 0 MEASUrement:MEAS4:JITTERSummary:EYEWIDTHBER?
Sets or queries whether ISI is included in the jitter summary for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| state | enum | 0 | 1 | 0 does not add the ISI measurement as part of jitter summary; 1 adds the ISI measurement as part of jitter summary. |
MEASUrement:MEAS4:JITTERSummary:ISI 0 MEASUrement:MEAS4:JITTERSummary:ISI?
Sets or queries whether NPJ is included in the jitter summary for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | 0 | 1 | Adds or does not add the NPJ measurement as part of the jitter summary. |
MEASUrement:MEAS4:JITTERSummary:NPJ 0 MEASUrement:MEAS4:JITTERSummary:NPJ? might return MEASUREMENT:MEAS4:JITTERSUMMARY:NPJ 1
Sets or queries whether PJ is included in the jitter summary for the specified measurement. Measurements are identified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | 0 | 1 | Adds or removes the PJ measurement as part of the jitter summary. |
MEASUrement:MEAS4:JITTERSummary:PJ 0 MEASUrement:MEAS4:JITTERSummary:PJ?
Sets or queries whether the PL measurement is included in the jitter summary for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 - 6 | Specifies the measurement number. |
| state | enum | 0 | 1 | Adds or removes the PL measurement from the jitter summary. |
MEASUrement:MEAS4:JITTERSummary:PL 0 specifies that the PL measurement is not part of the jitter summary. MEASUrement:MEAS4:JITTERSummary:PL? might return MEASUREMENT:MEAS4:JITTERSUMMARY:PL 1 indicating the PL measurement is part of the jitter summary.
Sets or queries whether RJ is included in the jitter summary for the specified measurement. Measurements are identified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | 1 adds the RJ measurement as part of the jitter summary; 0 does not add it. |
MEASUrement:MEAS4:JITTERSummary:RJ 0 MEASUrement:MEAS4:JITTERSummary:RJ? might return MEASUREMENT:MEAS4:JITTERSUMMARY:RJ 1 indicating the RJ measurement is part of the jitter summary.
Sets or queries whether RJ-dd is included in the jitter summary for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Enables or disables inclusion of RJ-dd in the jitter summary. |
Sets or queries whether TIE is included in the jitter summary for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 - 6 | Specifies the measurement number. |
| state | enum | 0 | 1 | 0 do not add the TIE measurement as part of jitter summary; 1 add the TIE measurement as part of jitter summary. |
MEASUrement:MEAS4:JITTERSummary:TIE 0 MEASUrement:MEAS4:JITTERSummary:TIE? might return MEASUREMENT:MEAS4:JITTERSUMMARY:TIE 1
Sets or queries whether TJ@BER is included in the jitter summary for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 | Specifies the measurement number. |
| state | enum | 0 | 1 | Adds or removes the TJ@BER measurement as part of the jitter summary. |
MEASUrement:MEAS4:JITTERSummary:TJBER 0 MEASUrement:MEAS4:JITTERSummary:TJBER? might return MEASUREMENT:MEAS4:JITTERSUMMARY:TJBER 1
Sets or queries the label for the specified measurement. The label is stored in Percent Encoding format because it can contain non 7-bit ASCII text.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| label | string | - | Measurement label. |
MEASUrement:MEAS1:LABel "Delay" MEASUrement:MEAS1:LABel?
Sets or queries the selected lines for measurement x. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| line selection | enum | ABCB | ACBC | BACA | XYZY | XZYZ | YXZX | Selected lines for the measurement. |
Sets or queries the low reference voltage value for the "time outside level" measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| low reference voltage | real | V | Low reference voltage value for the selected configuration. |
MEASUrement:MEAS1:LOWREFVoltage -1.30 MEASUrement:MEAS1:LOWREFVoltage?
Sets or queries the measurement Low Torque value. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 0 - 10000000 | Low Torque value of the selected measurement. |
MEASUrement:MEAS1:LTORque 10.5 MEASUrement:MEAS1:LTORque?
Sets or returns the level type for measurement x as auto or custom. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| level type | enum | AUTO | CUSTom | Specifies the value for the level type. |
MEASUrement:MEAS1:LTYPe AUTO MEASUrement:MEAS1:LTYPe?
Sets or returns the value for the level type as auto or custom. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | AUTO | CUSTom | Level type setting. |
MEASUrement:MEAS1:LTYPe AUTO MEASUrement:MEAS1:LTYPe?
Sets or returns the value for the level units as percentage or absolute. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| units | enum | PERCent | ABSolute | Specifies the value for the level units. |
MEASUrement:MEAS1:LUNITs PERCent MEASUrement:MEAS1:LUNITs?
Sets or returns the value for the level units as percentage or absolute. Measurements are specified by x.
MEASUrement:MEAS1:LUNITs PERCent MEASUrement:MEAS1:LUNITs?
Sets or queries the Low Voltage value for the specified measurement. Measurement number x selects which measurement is affected.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| low voltage | real | -100 - 100 | Low Voltage value of the measurement. |
MEASUrement:MEAS1:LVOLtage 10.5 MEASUrement:MEAS1:LVOLtage?
Sets or returns the Low Voltage value for measurement x. Requires an IMDA-MECH license on MSO 5, 6, and 6B series instruments.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Specifies the measurement number. |
| voltage | real | -100 - 100 | Specifies the Low Voltage value of the measurement. |
MEASUrement:MEAS1:LVOLtage 10.5 MEASUrement:MEAS1:LVOLtage? might return MEASUrement:MEAS1:LVOLtage 10.5
Sets or queries the maximum current for a measurement. The query returns the current maximum current setting.
| Name | Type | Values | Description |
|---|---|---|---|
| current | real | - | Maximum current value. |
MEASUrement:MEAS1:MAXCUrrent 5.0000 MEASUrement:MEAS1:MAXCUrrent?
Returns the maximum current setting for the selected measurement. The query may return the command with the current value appended.
MEASUrement:MEAS1:MAXCUrrent 5.0000 MEASUrement:MEAS1:MAXCUrrent?
Sets or queries the maximum cycle value for the DDRTERRN and DDRTERRMN measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 2 - 50 | Specifies the measurement number. |
| value | integer | 2 - 50 | Maximum cycle range limit value. |
MEASurement:MEAS2:MAXCycle 45 sets the maximum cycle value for measurement 2 to 45. MEASurement:MEAS1:MAXCycle? might return MEASurement:MEAS1:MAXCycle 17, indicating the maximum cycle value is set to 17 for measurement 1.
Sets or queries the maximum cycle value for the DDRTERRN and DDRTERRMN measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 2 - 50 | Specifies the measurement number. |
MEASurement:MEAS2:MAXCycle 45 sets the maximum cycle value for measurement 2 to 45. MEASurement:MEAS1:MAXCycle? might return MEASurement:MEAS1:MAXCycle 17, indicating the maximum cycle value is set to 17 for measurement 1.
Sets or returns the maximum gate voltage 1 or 2 value for Tdt measurement. Measurements are specified by x.
Sets or queries the maximum gate voltage 1 or 2 value for Tdt measurement. Measurements are specified by x.
Sets or queries the maximum gate voltage for measurement x. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 2 | Specifies the gate voltage number. |
| voltage | real | - | Specifies the maximum gate voltage. |
MEASUrement:MEAS1:MAXG1Voltage 10.0000 MEASUrement:MEAS1:MAXG1Voltage? might return MEASUrement:MEAS1:MAXGVoltage 10.0000, indicating the maximum gate voltage 1 value is 10.0000.
Sets or queries the maximum gate voltage for measurement x. The valid measurement index x is 1 or 2.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 2 | Measurement index. |
MEASUrement:MEAS1:MAXG1Voltage 10.0000 MEASUrement:MEAS1:MAXG1Voltage?
Sets or queries the maximum input voltage for measurement x. The value is specified in volts in the range of -61 V to +61 V.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | -61 - +61 | The maximum input voltage. |
MEASUrement:MEAS<x>:MAXVoltage <NR2> MEASUrement:MEAS<x>:MAXVoltage?
Sets or queries the maximum input voltage for measurement x. The value must be in the range of -61 V to +61 V.
| Name | Type | Values | Description |
|---|---|---|---|
| voltage | real | -61 - +61 | Maximum input voltage. |
MEASUrement:MEAS<x>:MAXVoltage 10.0000 MEASUrement:MEAS<x>:MAXVoltage?
Sets or queries the range settings global flag for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | - | - | Specifies the measurement number. |
| state | enum | OFF | ON | 0 | 1 | OFF or 0 sets range settings independently for each measurement; ON or 1 applies global measurement range settings to all measurements. |
MEASUrement:MEAS1:MEASRange:GLOBal 1 applies global measurement range settings to all the measurements' range settings. MEASUrement:MEAS1:MEASRange:GLOBal? might return MEASUREMENT:MEAS1:MEASRANGE:GLOBAL 0 indicating that range settings can be set independently for each individual measurement.
Sets or queries the range settings global flag for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Enables or disables global measurement range settings for the measurement. |
MEASUrement:MEAS1:MEASRange:GLOBal 1 applies global measurement range settings to all the measurements' range settings. MEASUrement:MEAS1:MEASRange:GLOBal? might return MEASUREMENT:MEAS1:MEASRANGE:GLOBAL 0 indicating that range settings can be set independently for each individual measurement.
Sets or queries the range maximum value for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | The maximum measurement range limit value. |
MEASUrement:MEAS1:MEASRange:MAX 2.50 sets the maximum range to 2.5 V. MEASUrement:MEAS1:MEASRange:MAX? might return MEASUREMENT:MEAS1:MEASRANGE:MAX 1.0000 indicating the maximum range is 1.0 V.
Sets or queries the maximum measurement range value for measurement x. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The maximum measurement range limit value. |
MEASUrement:MEAS1:MEASRange:MAX 2.50 sets the maximum range to 2.5 V. MEASUrement:MEAS1:MEASRange:MAX? might return MEASUREMENT:MEAS1:MEASRANGE:MAX 1.0000 indicating the maximum range is 1.0 V.
Sets or queries the range minimum value for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| value | real | - | Minimum measurement range limit value. |
MEASUrement:MEAS1:MEASRange:MIN -1.0 MEASUrement:MEAS1:MEASRange:MIN?
Sets or queries the minimum measurement range value for the specified measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| range minimum value | real | - | Minimum measurement range limit value. |
MEASUrement:MEAS1:MEASRange:MIN -1.0 MEASUrement:MEAS1:MEASRange:MIN?
Sets or queries the range state for the specified measurement. Use it to turn measurement range limits on or off.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Turns measurement range limits off or on. |
MEASUrement:MEAS1:MEASRange:STATE 0 MEASUrement:MEAS1:MEASRange:STATE?
Sets or queries the range state for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:MEASRange:STATE 0 MEASUrement:MEAS1:MEASRange:STATE? might return MEASUREMENT:MEAS1:MEASRANGE:STATE 1 indicating the measurement range limits are on.
Sets or queries the signal source for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
Sets or queries the signal source for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
Sets the cycles per rotation for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | The measurement number. |
| cycles per rotation | real | - | The number of cycles per rotation. |
MEASUrement:MEAS1:MECH:CPRotation 10.0000 sets the number of cycles per rotation as 10. MEASUrement:MEAS1:MECH:CPRotation? might return MEASUrement:MEAS1:MECH:CPRotation 10.0000, indicating that the number of cycles per rotation is 10.
Sets or queries the cycles per rotation for the measurement. Requires the IMDA-MECH license on MSO 5B and 6B series instruments.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | - | - | Measurement number x in MEAS<x>. |
| cycles per rotation | real | - | Number of cycles per rotation. |
MEASUrement:MEAS1:MECH:CPRotation 10.0000 sets the number of cycles per rotation as 10. MEASUrement:MEAS1:MECH:CPRotation? might return MEASUrement:MEAS1:MECH:CPRotation 10.0000, indicating that the number of cycles per rotation is 10.
Sets or queries the Index Z check box state for the specified measurement. The state can be enabled or disabled using ON/OFF or 1/0.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | 1 | 0 | Enables or disables the Index Z check box state. |
MEASUrement:MEAS1:MECH:EINDexz ON MEASUrement:MEAS1:MECH:EINDexz?
Queries the Index Z check box state for the specified mechanical measurement. The returned value indicates whether Index Z is enabled or disabled.
MEASUrement:MEAS1:MECH:EINDexz? might return MEASUREMENT:MEAS1:MECH:EINDexz ON, indicating the Index Z check box state is enabled.
Sets or queries the gear ratio for the specified mechanical measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| ratio | real | 0.001 - 1000 | Gear ratio value for the specified measurement. |
MEASUrement:MEAS1:MECH:GRATio 1.000E-3 MEASUrement:MEAS1:MECH:GRATio?
Sets or queries the gear ratio for the specified measurement x. The gear ratio value must be between 0.001 and 1000.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 0.001 - 1000 | Gear ratio value for the specified measurement. |
MEASUrement:MEAS1:MECH:GRATio 1.000E-3 MEASUrement:MEAS1:MECH:GRATio?
Sets or queries the units of the specific measurement. The available units are NM, OZINCH, FTLB, INCHLB, DEGREES, and RADIANS.
| Name | Type | Values | Description |
|---|---|---|---|
| units | enum | NM | OZINCH | FTLB | INCHLB | DEGREES | RADIANS | Defines the results units of the measurement. |
MEASUrement:MEAS1:MECH:MUNits DEGREES MEASUrement:MEAS1:MECH:MUNits? might return MEASUREMENT:MEAS1:MECH:MUNits DEGREES
Sets or queries the results units of measurement x for mechanical measurements. The query returns the current units selection.
| Name | Type | Values | Description |
|---|---|---|---|
| units | enum | NM | OZINCH | FTLB | INCHLB | DEGREES | RADIANS | Results units of the measurement. |
MEASUrement:MEAS1:MECH:MUNits DEGREES MEASUrement:MEAS1:MECH:MUNits? might return MEASUREMENT:MEAS1:MECH:MUNits DEGREES, indicating the results units of the measurement is DEGREES.
Sets or queries the number of pole pairs for the specified measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 - 20 | The number of pole pairs for the specified measurement. |
MEASUrement:MEAS1:MECH:PPAirs 4 defines the number of pole pairs for the specified measurement as 4. MEASUrement:MEAS1:MECH:PPAirs? might return MEASUREMENT:MEAS1:MECH:PPAirs 4 indicating the number of pole pairs for the specified measurement is 4.
Sets or queries the number of pole pairs for the specified measurement x. The valid range is 1 to 20.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | 1 - 20 | Number of pole pairs for the specified measurement. |
MEASUrement:MEAS1:MECH:PPAirs 4 defines the number of pole pairs for the specified measurement as 4. MEASUrement:MEAS1:MECH:PPAirs? might return MEASUREMENT:MEAS1:MECH:PPAirs 4 indicating the number of pole pairs for the specified measurement is 4.
Sets or queries the pulses per rotation for the specified measurement. The value is an NR1 integer in the range 1 to 10000.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 - x | Specifies the measurement number. |
| pulses per rotation | integer | 1 - 10000 | Defines the pulses per rotation of the measurement. |
MEASUrement:MEAS1:PPRotation 25 defines the pulses per rotation for measurement 1 as 25. MEASUrement:MEAS1:PPRotation? might return MEASUrement:MEAS1:PPRotation 25, indicating the pulses per rotation for measurement 1 is 25.
Returns or sets the pulses per rotation for the specified measurement. The value is an NR1 integer in the range 1 to 10000.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 - 10000 | Measurement number. |
MEASUrement:MEAS1:PPRotation 25 defines the pulses per rotation for measurement 1 as 25. MEASUrement:MEAS1:PPRotation? might return MEASUrement:MEAS1:PPRotation 25, indicating the pulses per rotation for measurement 1 is 25.
Sets or queries the local measurement sensor type for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| sensor type | enum | HSENSOR | QEI | RESOLVER | SCOSINE | Selects the local measurement sensor type. |
MEASUrement:MEAS1:MECH:STYPe HSENSOR MEASUrement:MEAS1:MECH:STYPe?
Sets or queries the local measurement sensor type for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | 1 | Specifies the measurement number. |
| type | enum | HSENSOR | QEI | RESOLVER | SCOSINE | Sets the sensor type. |
MEASUrement:MEAS1:MECH:STYPe HSENSOR MEASUrement:MEAS1:MECH:STYPe? might return MEASUREMENT:MEAS1:MECH:STYPe HSENSOR, indicating the sensor type is HSENSOR.
Sets or queries the minimum cycle value for the DDRTERRN and DDRTERRMN measurements.
Sets or queries the minimum cycle value for the DDRTERRN and DDRTERRMN measurements.
Sets or queries the number of unit intervals used for the Base Measurement Type of NUnitInterval.
| Name | Type | Values | Description |
|---|---|---|---|
| N | integer | 2 - 50 | Number of unit intervals used for the measurement. |
Sets or queries the number of unit intervals used for the Base Measurement Type of NUnitInterval.
Sets or queries the Nominal Voltage Method for green power measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | CUSTOM | Specifies the Nominal Voltage Method. |
MEASUrement:MEAS1:NVMethod AUTO MEASUrement:MEAS1:NVMethod?
Sets or queries the Nominal Voltage Method for green power measurements. Requires the PWR option.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | CUSTOM | Nominal Voltage Method setting. |
MEASUrement:MEAS1:NVMethod AUTO MEASUrement:MEAS1:NVMethod?
Sets or queries the RF measurement Occupied Bandwidth method type for measurement x. The default method is percentage of power.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | percOfPwr | dBDown | Occupied Bandwidth method type. |
MEASUrement:MEAS1:OBWMethod percOfPwr MEASUrement:MEAS1:OBWMethod?
Sets or queries the RF measurement Occupied Bandwidth method type. Measurements are specified by x.
MEASUrement:MEAS1:OBWMethod percOfPwr specifies the method type to percentage of power. MEASUrement:MEAS1:OBWMethod? might return MEASUREMENT:MEAS1:OBWMethod percOfPwr, indicating the method type is percentage of power.
Sets or queries the harmonics odd/even display selection for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | ALL | EVEN | ODD | Selects which harmonics results to display. |
MEASurement:MEAS1:ODDEVen ALL displays all the harmonics results for measurement 1.
Sets or queries harmonics oddeven for the specified measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| mode | enum | ALL | EVEN | ODD | Selects which harmonics results to display. |
MEASurement:MEAS1:ODDEVen ALL displays all the harmonics results for measurement 1.
Sets or returns the cut-off frequency value for a measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| cut-off frequency value | real | - | Specifies the cut-off frequency value for a measurement. |
MEASurement:MEAS1:OFILters:LOWPass:FREQ 500E+6 MEASurement:MEAS1:OFILters:LOWPass:FREQ?
Sets or returns the cut-off frequency value for a measurement. Requires the IMDA-MECH license on MSO 5, 6, and 6B series instruments.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| value | real | - | Cut-off frequency value for the measurement. |
MEASurement:MEAS1:OFILters:LOWPass:FREQ 500E+6 MEASurement:MEAS1:OFILters:LOWPass:FREQ?
Sets or returns the low pass filter specification for a measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| specification | enum | NONE | FIRST | SECOND | THIRD | Selects the low pass filter specification for the measurement. |
Sets or returns the low pass filter specification for a measurement.
Sets or queries the specified measurement offset angle.
| Name | Type | Values | Description |
|---|---|---|---|
| angle | real | -360 - 360 | Offset angle of the measurement. |
MEASurement:MEAS1:OSANgle 10 MEASurement:MEAS1:OSANgle?
Sets or queries the specified measurement offset angle.
| Name | Type | Values | Description |
|---|---|---|---|
| offset angle | real | -360 - 360 | Offset angle of the measurement. |
MEASurement:MEAS1:OSANgle 10 MEASurement:MEAS1:OSANgle?
Sets or queries the local output edge qualifier source for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the local output edge qualifier. |
MEASUrement:MEAS1:OUTEDGEQUALifier CH3 sets the local output edge qualifier source to channel 3. MEASUrement:MEAS1:OUTEDGEQUALifier? might return MEASUrement:MEASUrement:MEAS1:OUTEDGEQUALifier CH2 indicating the local output edge qualifier source is channel 2.
Sets or queries the local output edge qualifier source for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Selects the source waveform for the local output edge qualifier. |
MEASUrement:MEAS1:OUTEDGEQUALifier CH3 sets the local output edge qualifier source to channel 3. MEASUrement:MEAS1:OUTEDGEQUALifier? might return MEASUrement:MEAS1:OUTEDGEQUALifier CH2 indicating the local output edge qualifier source is channel 2.
Sets or queries the measurement output low pass filter cutoff frequency on the scope. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| frequency | real | 20 - 10e6 | Specifies the output filter cutoff frequency. |
MEASurement:MEAS1:OUTFILTers:LOWPass:FREQ 2.000E+6 MEASurement:MEAS1:OUTFILTers:LOWPass:FREQ?
Queries the measurement output low pass filter cutoff frequency for measurement x. The command also sets the cutoff frequency when used without '?'.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASurement:MEAS1:OUTFILTers:LOWPass:FREQ? might return MEASurement:MEAS1:OUTFILTers:LOWPass:FREQ 2.000E+6, indicating the value for the output filter cutoff
Sets or queries the measurement output low pass filter specification order on the scope. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| order | enum | NONE | FIRST | SECOND | THIRD | Specifies the filter order. |
MEASUrement:MEAS1:OUTFILTers:LOWPass:SPEC SECOND MEASUrement:MEAS1:OUTFILTers:LOWPass:SPEC? might return MEASUrement:MEAS1:OUTFILTers:LOWPass:SPEC SECOND, indicating the filter order is set to second.
Sets or queries the measurement output low pass filter specification filter order on the scope. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | NONE | FIRST | SECOND | THIRD | Specifies the filter order. |
MEASUrement:MEAS1:OUTFILTers:LOWPass:SPEC SECOND MEASUrement:MEAS1:OUTFILTers:LOWPass:SPEC?
Sets or queries the voltage level for the specified output voltage source n.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
Sets or queries the voltage level for the specified output voltage source n.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
Returns or sets the pass/fail test enable status for the specified measurement. If enabled, pass/fail testing is turned on for that measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | integer | 0 - 1 | Enables or disables pass/fail testing for the specified measurement. |
MEASUrement:MEAS1:PASSFAILENabled 1 enables pass fail testing for the specified measurement. MEASUrement:MEAS1:PASSFAILENabled? might return MEASUrement:MEAS1:PASSFAILENabled 0 indicating that pass fail testing for the specified measurement is disabled.
Returns or sets the pass/fail test enable status for the specified measurement. If enabled, pass/fail testing is turned on for that measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | integer | 0 - 1 | Enables or disables pass fail testing for the specified measurement; 1 enables and 0 disables. |
MEASUrement:MEAS1:PASSFAILENabled 1 enables pass fail testing for the specified measurement. MEASUrement:MEAS1:PASSFAILENabled? might return MEASUrement:MEAS1:PASSFAILENabled 0 indicating that pass fail testing for the specified measurement is disabled.
Returns or sets the high limit for a measurement test. It is used as the test value when the "fail when" criteria is set to "less than" or "greater than".
| Name | Type | Values | Description |
|---|---|---|---|
| limit | real | - | Sets the high limit for a measurement test. |
MEASUrement:MEAS1:PASSFAILHIGHlimit 710 MEASUrement:MEAS1:PASSFAILHIGHlimit? might return MEASUrement:MEAS1:PASSFAILHIGHlimit 710
Returns or sets the high limit for a measurement test. The value is used as the test limit when the fail-when criteria is set to less than or greater than.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number to which this command applies. |
| value | real | - | High limit value for the measurement test. |
MEASUrement:MEAS1:PASSFAILHIGHlimit 710 MEASUrement:MEAS1:PASSFAILHIGHlimit?
Returns or sets the limit for a measurement test. It is used as the test value when the "fail when" criteria is set to "less than" or "greater than"; measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Sets the limit for the measurement test. |
MEASUrement:MEAS1:PASSFAILLIMit 710 MEASUrement:MEAS1:PASSFAILLIMit?
Returns or sets the limit for a measurement test. It is used as the test value when the "fail when" criteria is set to "less than" or "greater than".
| Name | Type | Values | Description |
|---|---|---|---|
| <NR2> | real | - | Sets the limit for a measurement test; the limit is a number which a measurement result will be tested against. |
MEASUrement:MEAS1:PASSFAILLIMit 710 MEASUrement:MEAS1:PASSFAILLIMit? might return MEASUrement:MEAS1:PASSFAILLIMit 710
Returns or sets the low limit for a measurement test. The low limit is used as the test value when the fail-when criteria is set to less than or greater than.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number identifier. |
| low limit | real | - | Low limit value for the measurement test. |
MEASUrement:MEAS1:PASSFAILLOWlimit 690 MEASUrement:MEAS1:PASSFAILLOWlimit?
Returns or sets the low limit for a measurement test. The low limit is used as the test value when the fail-when criteria is set to "less than" or "greater than".
MEASUrement:MEAS1:PASSFAILLOWlimit 690 MEASUrement:MEAS1:PASSFAILLOWlimit?
Returns or sets the allowed margin for limit comparisons for all pass/fail checks. The margin is given as a percentage and defaults to 0.05 (5%).
| Name | Type | Values | Description |
|---|---|---|---|
| margin | real | % | Allowed margin for pass/fail limit comparisons. |
Returns or sets the allowed margin for limit comparisons for all pass/fail checks. The margin is given as a percentage with a default value of 0.05 representing 5%.
| Name | Type | Values | Description |
|---|---|---|---|
| margin | real | % | Allowed margin for limit comparisons. |
Sets or returns the condition on which a measurement test fails. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| condition | enum | LESSthan | GREATERthan | Equals | NOTEQuals | INSIDErange | OUTSIDErange | Condition for measurement test failure. |
MEASUrement:MEAS1:PASSFAILWHEN LESSthan specifies the condition for measurement 1 test failure as less that the given limit.
Sets or returns the condition on which a measurement test fails. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| condition | enum | LESSthan | GREATERthan | Equals | NOTEQuals | INSIDErange | OUTSIDErange | Condition for measurement test failure. |
MEASUrement:MEAS1:PASSFAILWHEN LESSthan
Sets or queries the pattern detection type for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | MANUAL | AUTO automatically detects the pattern; MANUAL requires manually detecting the pattern. |
MEASUrement:MEAS1:PATTERNDETECTION MANUAL MEASUrement:MEAS1:PATTERNDETECTION? might return MEASUREMENT:MEAS1:PATTERNDETECTION AUTO
Sets or queries the pattern detection type for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:PATTERNDETECTION MANUAL MEASUrement:MEAS1:PATTERNDETECTION?
Sets or queries the pattern length for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The pattern length. |
MEASUrement:MEAS1:PATTERNLENgth 3.0 MEASUrement:MEAS1:PATTERNLENgth? might return MEASUREMENT:MEAS1:PATTERNLENGTH 2.0000 indicating the pattern length is 2.0.
Sets or queries the pattern length for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| pattern length | real | - | The pattern length. |
MEASUrement:MEAS1:PATTERNLENgth 3.0 MEASUrement:MEAS1:PATTERNLENgth?
Sets or queries the pattern type for measurement x. The available pattern types are repeating or arbitrary.
| Name | Type | Values | Description |
|---|---|---|---|
| pattern type | enum | REPeating | ARBitrary | Selects the measurement pattern type. |
MEASUrement:MEAS1:PATTERNTYPe ARBITRARY MEASUrement:MEAS1:PATTERNTYPe?
Queries the pattern type for measurement x. The response indicates whether the pattern is repeating or arbitrary.
MEASUrement:MEAS1:PATTERNTYPe? might return MEASUREMENT:MEAS1:PATTERNTYPE REPEATING indicating a repeating pattern.
Sets or returns the number of pulses for measurement x. Measurements are specified by x and this command requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | - | Number of pulses. |
MEASUrement:MEAS1:PCOUNt 10 sets the number of pulses to 10. MEASUrement:MEAS1:PCOUNt? might return MEASUREMENT:MEAS1:PCOUNt 10, indicating the number of pulses is 10.
Sets or queries the number of pulses for measurement x. Measurements are specified by x and this command requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | - | The number of pulses. |
MEASUrement:MEAS1:PCOUNt 10 sets the number of pulses to 10. MEASUrement:MEAS1:PCOUNt? might return MEASUREMENT:MEAS1:PCOUNt 10, indicating the number of pulses is 10.
Sets or queries the edge selection used for the PERFREQ measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| edge | enum | FIRST | RISE | FALL | Selects whether the measurement is computed between the first detected edge, rising edges, or falling edges. |
MEASUrement:MEAS1:PERFREQ:EDGE RISE specifies computing the measurement between Rising edges. measurement:meas1:perfreq:edge? might return MEASUREMENT:MEAS1:PERFREQ:EDGE FIRST if the measurement is computed between edges of the first type edge found.
Sets or queries the edge selection used for the PERFREQ measurement. The result indicates whether the first, rising, or falling edge is used for the measurement computation.
MEASUrement:MEAS1:PERFREQ:EDGE RISE measurement:meas1:perfreq:edge? might return MEASUREMENT:MEAS1:PERFREQ:EDGE FIRST
Sets or returns the PJ max frequency value for a PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| <NR3> | real | - | Specifies the value of PJ max frequency for PSIJ measurement. |
MEASUrement:MEAS2:PFREquency 1.0000 MEASUrement:MEAS2:PFREquency?
Sets or returns the PJ max frequency value of a PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Value of PJ max frequency for PSIJ measurement. |
MEASUrement:MEAS2:PFREquency 1.0000 MEASUrement:MEAS2:PFREquency?
Sets the polarity used for the measurement. The slice shows that INVERTED specifies inverted polarity, and the query form may return the current polarity such as NORMAL.
| Name | Type | Values | Description |
|---|---|---|---|
| polarity | enum | INVERTED | Specifies inverted polarity. |
MEASUrement:MEAS1:POLarity INVERTED specifies inverted polarity. MEASUrement:MEAS1:POLarity? might return MEASUREMENT:MEAS1:POLARITY NORMAL indicating normal polarity.
Returns the polarity setting for the specified measurement. The example shows the query may return NORMAL or INVERTED polarity.
MEASUrement:MEAS1:POLarity? might return MEASUREMENT:MEAS1:POLARITY NORMAL indicating normal polarity.
Sets or queries the population settings global flag for measurement x. OFF/0 allows population settings to be changed independently for each measurement; ON/1 applies the global population settings to all measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | OFF | ON | 0 | 1 | Selects whether population settings are independent per measurement or applied globally. |
MEASUrement:MEAS1:POPUlation:GLOBal 1 applies the global population settings to all the measurements' population settings.
Sets or queries the population settings global flag for the specified measurement. OFF/0 allow population settings to be changed independently for each measurement; ON/1 apply the global population settings to all measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| state | enum | OFF | ON | 0 | 1 | Selects whether population settings are independent per measurement or applied globally. |
MEASUrement:MEAS1:POPUlation:GLOBal 1 applies the global population settings to all the measurements' population settings.
Sets or queries the Percentage Power to be measured for the Occupied Bandwidth measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 60.0 - 99.9 | Percentage Power value to be measured. |
MEASUrement:MEAS1:POPower 99 sets power to 99%. MEASUrement:MEAS1:POPower? might return MEASUREMENT:MEAS1:POPower 99 indicating the power is set to 99%.
Sets or queries the Percentage Power to be measured for the Occupied Bandwidth measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 60.0 - 99.9 | Sets the Percentage Power value. |
MEASUrement:MEAS1:POPower 99 sets power to 99%. MEASUrement:MEAS1:POPower? might return MEASUREMENT:MEAS1:POPower 99 indicating the power is set to 99%.
Sets or queries the population limit state for the specified measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Turns the population limit off or on. |
MEASUrement:MEAS1:POPUlation:LIMIT:STATE 0 turns off the population limit. MEASUrement:MEAS1:POPUlation:LIMIT:STATE? might return MEASUREMENT:MEAS1:POPULATION:LIMIT:STATE 1 indicating the population limit is on.
Sets or queries the population limit state for the specified measurement. The measurement number is given by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | ON | 0 | 1 | Turns the population limit off or on. |
MEASUrement:MEAS1:POPUlation:LIMIT:STATE 0 turns off the population limit. MEASUrement:MEAS1:POPUlation:LIMIT:STATE? might return MEASUREMENT:MEAS1:POPULATION:LIMIT:STATE 1 indicating the population limit is on.
Sets or queries the population limit value for the specified measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | The current limit value. |
MEASUrement:MEAS1:POPUlation:LIMIT:VALue 2000 sets the population limit to 2000. MEASUrement:MEAS1:POPUlation:LIMIT:VALue? might return MEASUREMENT:MEAS1:POPULATION:LIMIT:VALUE 1000 indicating the limit is set to 1000.
Sets or queries the population limit value for the specified measurement. The measurement number is specified by x.
Sets or queries the power factor value for IEC-Class C type harmonics standard. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| power factor value | real | - | Power factor value for class C harmonics standard. |
MEASUrement:MEAS1:POWERFACtor 50 MEASUrement:MEAS1:POWERFACtor?
Sets or queries the power factor value for IEC-Class C type harmonics standard. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| power factor value | real | - | Power factor value for the class C harmonics standard. |
MEASUrement:MEAS1:POWERFACtor 50 sets the power factor value to 50. MEASUrement:MEAS1:POWERFACtor? might return MEASUREMENT:MEAS1:POWERFACtor 50 indicating the power factor is 50.
Sets or returns the pulse region for a measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| region | enum | FPULse | SPULse | MPULse | Selects the pulse region. |
MEASUrement:MEAS1:PREGion Fpulse sets the pulse region to Fpulse. MEASUrement:MEAS1:PREGion? might return MEASUREMENT:MEAS1:PREGion Fpulse, indicating the pulse region is set to Fpulse.
Sets or returns the pulse region for a measurement. Requires a WBG-DPT license.
MEASUrement:MEAS1:PREGion Fpulse MEASUrement:MEAS1:PREGion?
Sets or returns the value of probe resistance for the WBG measurement. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Specifies the value for probe resistance of the WBG measurement. |
MEASUrement:MEAS2:PRESistance 1.0000E+3 MEASUrement:MEAS2:PRESistance?
Sets or returns the probe resistance value for a WBG measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| value | real | - | Value of probe resistance for the WBG measurement. |
MEASUrement:MEAS2:PRESistance 1.0000E+3 MEASUrement:MEAS2:PRESistance?
Sets or returns the PJ threshold value of the PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| value | real | - | Specifies the value of PJ threshold for the PSIJ measurement. |
MEASUrement:MEAS2:PTHReshold 1.00E-21 MEASUrement:MEAS2:PTHReshold?
Sets or returns the PJ threshold value of the PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| threshold | real | - | Specifies the value of PJ threshold for PSIJ measurement. |
MEASUrement:MEAS2:PTHReshold 1.00E-21 MEASUrement:MEAS2:PTHReshold?
Sets or returns pulse width for the specified measurement. Measurements are specified by x.
Sets or queries the Per Unit Nominal Voltage for green power measurements. Requires option PWR.
| Name | Type | Values | Description |
|---|---|---|---|
| voltage | real | V | Specifies the Per Unit Nominal Voltage of green power measurements. |
MEASUrement:MEAS1:PUNVoltage 170.0000 sets the Per Unit Nominal Voltage as 170 V. MEASUrement:MEAS1:PUNVoltage? might return MEASUrement:MEAS1:PUNVoltage 170.0000, indicating that the Per Unit Nominal Voltage is 170 V.
Sets or queries the Per Unit Nominal Voltage for green power measurements. Requires option PWR.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | V | Specifies the Per Unit Nominal Voltage of green power measurements. |
MEASUrement:MEAS1:PUNVoltage 170.0000 sets the Per Unit Nominal Voltage as 170 V. MEASUrement:MEAS1:PUNVoltage? might return MEASUrement:MEAS1:PUNVoltage 170.0000, indicating that the Per Unit Nominal Voltage is 170 V.
Sets or queries the pulse width for measurement x. The query returns the current pulse width value.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Specifies the pulse width. |
MEASUrement:MEAS1:PWIDth 15.0000 MEASUrement:MEAS1:PWIDth?
Enables or disables reconstructed clock for DPM measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns reconstructed clock on or off for the DPM measurement. |
Enables or disables reconstructed clock for DPM measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Turns reconstructed clock for DPM measurement on or off. |
Turns the Refine edge on qualifier on or off for the specified measurement. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Enables or disables the Refine edge settings for measurement x. |
MEASUrement:MEAS1:REDGe ON MEASUrement:MEAS1:REDGe?
Turns the Refine edge on qualifier on or off for the specified measurement. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Specifies whether Refine edge settings are enabled or disabled. |
MEASUrement:MEAS1:REDGe ON turns on the Refine edge on qualifier. MEASUrement:MEAS1:REDGe? might return MEASUREMENT:MEAS1:REDGe ON, indicating the Refine edge settings has been turned on.
Sets or queries the value used as the high reference level of the falling edge when the measurement's reference level method is set to absolute. This command affects the results of rise and fall measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
Sets or queries the value used as the high reference level of the falling edge when the measurement reference level method is set to absolute. This affects the results of rise and fall measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
Sets or queries the low reference level of the falling edge when the measurement reference level method is set to absolute. The command affects the results of rise and fall measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | V | The low reference level in volts. |
MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0 V sets the low reference level to 0.0 V. MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0000E+00, indicating that the absolute low reference level is set to 0.0 V.
Sets or queries the low reference level used for the falling edge when the measurement ref level method is absolute. This command affects the results of rise and fall measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | V | The low reference level in volts. |
MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0 V sets the low reference level to 0.0 V. MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0000E+00, indicating that the absolute low reference level is set to 0.0 V.
Sets or queries the mid reference level of the falling edge when the measurement ref level method is set to absolute. This setting affects period, frequency, delay, and all cyclic measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| NR3 | real | V | The mid reference level in volts. |
MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLMID 0.0 V MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLMID? might return
Sets or queries the value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute. Measurements are specified by x.
MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0 V sets the low reference level to 0.0 V. MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:FALLLOW 0.0000E+00, indicating that the absolute low reference level is set to 0.0 V.
Sets or queries the hysteresis of the reference level when the measurement's ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| hysteresis | real | - | The hysteresis value used for autoset. |
MEASUrement:MEAS1:REFLevels1:ABSolute:HYSTeresis 25.0E-3 sets the hysteresis to 25 mV. MEASUrement:MEAS1:REFLevels1:ABSolute:HYSTeresis? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:HYSTERESIS 30.0000E-3 indicating the hysteresis is set to 30 mV.
Sets or queries the hysteresis of the reference level when the measurement's ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:REFLevels1:ABSolute:HYSTeresis 25.0E-3 sets the hysteresis to 25 mV. MEASUrement:MEAS1:REFLevels1:ABSolute:HYSTeresis? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:HYSTERESIS 30.0000E-3 indicating the hysteresis is set to 30 mV.
Sets or queries the value used as the high reference level of the rising edge when the measurement's ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| level | real | - | The high reference level, and is the zero percent level when the measurement's Ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISEHigh 1.50 sets the high reference level to 1.5 V. MEASUrement:MEAS1:REFLevels1:ABSolute:RISEHigh? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:RISEHIGH 1.0000 indicating the high reference level is set to 1.0 V.
Sets or queries the value used as the high reference level of the rising edge when the measurement's ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| high reference level | real | - | The high reference level, and is the zero percent level when the measurement's Ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISEHigh 1.50 MEASUrement:MEAS1:REFLevels1:ABSolute:RISEHigh?
Sets or queries the low reference level of the rising edge when the measurement ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| level | real | - | The low reference level (zero percent level) used when the measurement's Ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISELow -1.50 MEASUrement:MEAS1:REFLevels1:ABSolute:RISELow?
Sets or queries the value used as the low reference level of the rising edge when the measurement's reference level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | 1 | Measurement number. |
| level | real | - | Low reference level; this is the zero percent level when the measurement's ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISELow? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:RISELOW -1.0000 indicating the low reference level is -1.0 V.
Sets or queries the value used as the mid reference level of the rising edge when the measurement's ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mid reference level | real | V | The mid reference level (where 50% is equal to MID) used to calculate the mid reference level when the measurement's Ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISEMid 30.0E-3 MEASUrement:MEAS1:REFLevels1:ABSolute:RISEMid?
Sets or queries the mid reference level of the rising edge when the measurement ref level method is set to absolute. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| NR3 | real | - | The mid reference level used to calculate the mid reference level when the measurement's Ref level method is set to Absolute. |
MEASUrement:MEAS1:REFLevels1:ABSolute:RISEMid 30.0E-3 MEASUrement:MEAS1:REFLevels1:ABSolute:RISEMid? might return
Sets the absolute reference-level type for the specified measurement. The type can be the same for both levels or set independently.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | SAME | UNIQue | Sets whether the absolute levels are the same or can be set independently. |
MEASUrement:MEAS1:REFLevels1:ABSolute:TYPE UNIQUE specifies that the absolute levels can be set independently. MEASUrement:MEAS1:REFLevels1:ABSolute:TYPE? might return MEASUREMENT:MEAS1:REFLEVELS1:ABSOLUTE:TYPE SAME indicating the absolute levels are set the same.
Sets or queries the method used to calculate absolute reference levels for a measurement. The measurement number is specified by x.
MEASUrement:MEAS1:REFLevels1:ABSolute:TYPE UNIQUE MEASUrement:MEAS1:REFLevels1:ABSolute:TYPE?
Sets or queries the method used to calculate the TOP and BASE used to calculate reference levels for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | MINMax | MEANhistogram | MODEhistogram | EYEhistogram | Method used to calculate reference levels for the measurement. |
MEASUrement:MEAS1:REFLevels1:BASETop MINMAX specifies that reference levels are relative to the measurement MEASUrement:MEAS1:REFLevels1:BASETop? might return MEASUREMENT:MEAS1:REFLEVELS1:BASETOP AUTO
Sets or queries the method used to calculate the TOP and BASE used to calculate reference levels for the measurement. The measurement number is specified by x.
MEASUrement:MEAS1:REFLevels1:BASETop? might return MEASUREMENT:MEAS1:REFLEVELS1:BASETOP AUTO indicating the instrument automatically chooses a reference level method.
Sets or queries the reference level method for a measurement. PERCENT calculates reference levels as a percent relative to HIGH and LOW; ABSOLUTE sets them explicitly using the ABSolute reference-level commands.
| Name | Type | Values | Description |
|---|---|---|---|
| method | enum | PERCent | ABSolute | Reference level calculation method. |
MEASUREMENT:MEAS1:REFLEVELS1:METHOD ABSOLUTE MEASUREMENT:MEAS1:REFLEVELS1:METHOD? might return MEASUREMENT:MEAS1:REFLEVELS1:METHOD PERCENT
Sets or queries the reference-level method for the specified measurement. Percent-based reference levels are calculated relative to HIGH and LOW, while Absolute uses explicit values.
MEASUREMENT:MEAS1:REFLEVELS1:METHOD ABSOLUTE MEASUREMENT:MEAS1:REFLEVELS1:METHOD?
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| percentage | real | % | Percentage used to calculate the high reference level; 100% is equal to HIGH. |
MEASUrement:MEAS1:REFLevels1:PERCent:FALLHigh 95.0 MEASUrement:MEAS1:REFLevels1:PERCent:FALLHigh?
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. The measurement number is specified by x.
MEASUrement:MEAS1:REFLevels1:PERCent:FALLHigh 95.0 MEASUrement:MEAS1:REFLevels1:PERCent:FALLHigh?
Sets or queries the percentage used to calculate the low reference level of the falling edge when the measurement's ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| percentage | real | % | Percentage used to calculate the low reference level of the falling edge. |
MEASUrement:MEAS1:REFLevels1:PERCent:FALLLow 5.0 sets the low reference level of the falling edge is 5%. MEASUrement:MEAS1:REFLevels1:PERCent:FALLLow? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:FALLLOW 10.0000 indicating the low reference level of the falling edge is 10%.
Sets or queries the percentage used to calculate the low reference level of the falling edge when the measurement ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| percentage | real | % | Percentage where 100% is equal to HIGH, used to calculate the low reference level. |
MEASUrement:MEAS1:REFLevels1:PERCent:FALLLow 5.0 MEASUrement:MEAS1:REFLevels1:PERCent:FALLLow? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:FALLLOW 10.0000
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement's ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| NR3 | real | - | Percentage used to calculate the mid reference level; 50% is equal to MID. |
MEASUrement:MEAS1:REFLevels1:PERCent:FALLMid 50.0 sets the mid reference level of the falling edge to 50%. MEASUrement:MEAS1:REFLevels1:PERCent:FALLMid? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:FALLMID 50.0000 indicating the mid reference level of the falling edge is set to 50%.
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | - | Percentage where 50% is equal to MID used to calculate the mid reference level. |
MEASUrement:MEAS1:REFLevels1:PERCent:FALLMid 50.0 sets the mid reference level of the falling edge to 50%. MEASUrement:MEAS1:REFLevels1:PERCent:FALLMid? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:FALLMID 50.0000 indicating the mid reference level of the falling edge is set to 50%.
Sets or queries the percentage used to calculate the hysteresis level when the measurement's ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| hysteresis | real | % | Percentage used to calculate the hysteresis level when the ref level method is set to Percent. |
MEASUrement:MEAS1:REFLevels1:PERCent:HYSTeresis 5.0 sets the hysteresis level to 5%. MEASUrement:MEAS1:REFLevels1:PERCent:HYSTeresis? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:HYSTERESIS 5.0000 indicating the hysteresis is 5.0%.
Sets or queries the percentage hysteresis used for the autoset. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| hysteresis | real | % | Hysteresis value used for the autoset. |
MEASUrement:MEAS1:REFLevels1:PERCent:HYSTeresis 5.0 sets the hysteresis level to 5%. MEASUrement:MEAS1:REFLevels1:PERCent:HYSTeresis? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:HYSTERESIS 5.0000 indicating the hysteresis is 5.0%.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement's ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| percentage | real | % | Percentage used to calculate the high reference level of the rising edge when ref level method is set to Percent. |
MEASUrement:MEAS1:REFLevels1:PERCent:RISEHigh 95.0 MEASUrement:MEAS1:REFLevels1:PERCent:RISEHigh?
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| percentage | real | % | Percentage value used to calculate the high reference level of the rising edge when the ref level method is set to Percent. |
MEASUrement:MEAS1:REFLevels1:PERCent:RISEHigh 95.0 MEASUrement:MEAS1:REFLevels1:PERCent:RISEHigh? might return MEASUREMENT:MEAS1:REFLEVELS1:PERCENT:RISEHIGH 90.0000
Sets the low reference level percentage for the specified measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | % | The percentage used to calculate the low reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MEAS1:REFLevels1:PERCent:RISELow 5.0 MEASUrement:MEAS1:REFLevels1:PERCent:RISELow?
Queries the low reference level percentage for the rising edge measurement reference levels. The measurement number is specified by x.
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement ref level method is set to percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement | integer | 1 - 6 | Measurement number x. |
| percentage | real | 0 - 100 | Percentage used to calculate the mid reference level of the rising edge. |
MEASUrement:MEAS1:REFLevels1:PERCent:RISEMid 50.0000 MEASUrement:MEAS1:REFLevels1:PERCent:RISEMid?
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement ref level method is set to Percent. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | % | Percentage used to calculate the mid reference level when the measurement Ref level method is set to Percent. |
MEASUrement:MEAS1:REFLevels1:PERCent:RISEMid 50.0000 MEASUrement:MEAS1:REFLevels1:PERCent:RISEMid?
Specifies or queries the reference level percent type for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | TENNinety | TWENtyeighty | CUSTom | Selects the percentage set used for Low, Mid, and High reference levels. |
MEASUrement:MEAS1:REFLevels1:PERCent:TYPE TWENtyeighty
Specifies or queries the reference level percent type for the measurement. The measurement number is specified by x.
MEASUrement:MEAS1:REFLevels1:PERCent:TYPE TWENtyeighty
Sets or queries the reference level mode for the measurement specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | MANual | Selects automatic reference level setup or manual reference level entry. |
MEASUrement:MEAS1:REFMode Manual MEASUrement:MEAS1:REFMode?
Sets or queries the reference level mode for the measurement. The measurement number is specified by x.
MEASUrement:MEAS1:REFMode Manual MEASUrement:MEAS1:REFMode?
Sets or queries the reference voltage value for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| value | real | - | Reference voltage value for the selected configuration. |
MEASUrement:MEAS1:REFVoltage 30.E-3 sets the reference voltage value for the measurement to 30 mV. MEASUrement:MEAS1:REFVoltage? might return MEASUREMENT:MEAS1:REFVOLTAGE 0.0E+0 indicating the reference voltage value for the measurement is 0.0 V.
Sets or queries the reference voltage value for the specified measurement. The measurement number is specified by x.
MEASUrement:MEAS1:REFVoltage 30.E-3 MEASUrement:MEAS1:REFVoltage?
Sets or queries the reference voltage for a specified rail within a specified measurement. The reference voltage is given in volts and can be in the range -500 V to +500 V.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Measurement number. |
| REFVOLTAGE<x> | integer | - | Rail number. |
| reference voltage | real | -500 - +500 | Reference voltage to set for the specified rail. |
MEASUrement:MEAS1:REFVOLTAGE3Val –125 MEASUrement:MEAS3:REFVOLTAGE1Val?
Sets or queries the reference voltage for a specified measurement rail. The measurement number is x and the rail number is x; the value is in the range of -500 V to +500 V.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Measurement number (x). |
| rail number | integer | - | Rail number (x). |
| reference voltage | real | -500 - +500 | Reference voltage to set for the specified rail. |
MEASUrement:MEAS1:REFVOLTAGE3Val –125 MEASUrement:MEAS3:REFVOLTAGE1Val?
Returns the maximum value for all accumulated measurement acquisitions of the specified measurement. The measurement number is specified by x.
MEASUrement:MEAS1:RESUlts:ALLAcqs:MAXimum? might return MEASUREMENT:MEAS1:RESULTS:ALLACQS:MAXIMUM 2.420 indicating the maximum measurement value is 2.420 V.
Returns the mean value for all accumulated measurement acquisitions for measurement <x>.
MEASUrement:MEAS1:RESUlts:ALLAcqs:MEAN? might return MEASUREMENT:MEAS1:RESULTS:ALLACQS:MEAN 2.2807617754647 indicating the measurement mean is 2.28 V.
Returns the minimum value for all accumulated measurement acquisitions for measurement <x>.
MEASUrement:MEAS1:RESUlts:ALLAcqs:MINimum? might return MEASUREMENT:MEAS1:RESULTS:ALLACQS:MINIMUM 2.220 indicating the measurement minimum value is 2.220 V.
Returns the peak-to-peak value for all accumulated measurement acquisitions for measurement <x>.
Returns the population measurement value for measurement <x>.
Returns the standard deviation for all accumulated measurement acquisitions for measurement <x>.
Returns the maximum value found for the specified measurement since the last statistical reset. The measurement number is specified by x.
MEASUrement:MEAS1:RESUlts:CURRentacq:MAXimum? might return MEASUREMENT:MEAS1:RESULTS:CURRENTACQ:MAXIMUM 2.280 indicating the current measurement maximum value is 2.28 V.
Query-only command that returns the mean value for the specified measurement in the current acquisition. MEAS<x> identifies the measurement number shown in the UI measurement badge.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Measurement number for which to return a value. |
MEASUrement:MEAS3:RESUlts:CURRentacq:MEAN? might return MEASUREMENT:MEAS3:RESULTS:CURRENTACQ:MEAN 2.30 indicating the mean of measurement 3 in the current acquisition is 2.3 V.
Query-only command that returns the minimum value for the specified measurement in the current acquisition. The measurement number is specified by x.
Returns the peak-to-peak value for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
MEASUrement:MEAS1:RESUlts:CURRentacq:PK2PK? might return MEASUREMENT:MEAS1:RESULTS:CURRENTACQ:PK2PK 0.0E+0 indicating the peak-to-peak value for the specified measurement for the current acquisition is 0.0 V.
Returns the population for the specified measurement for the current acquisition. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
MEASUrement:MEAS1:RESUlts:CURRentacq:POPUlation? might return MEASUREMENT:MEAS1:RESULTS:CURRENTACQ:POPULATION 1 indicating the population for the current measurement is 1 measurement.
Returns the standard deviation for the specified measurement for all acquisitions accumulated since statistics were last reset.
Returns the maximum value for the specified measurement for each acquisition in the history. The measurement number is specified by x.
MEASUrement:MEAS1:RESUlts:HISTory:MAXimum? might return MEASUrement:MEAS1:RESUlts:HISTory:MAXimum 2.28,2.31,2.27 indicating there are three acquisitions in the history and the maximum value for measurement 1 is 2.28 V for the first acquisition, 2.31 V for the second acquisition and 2.27 V for the third acquisition.
Returns the mean value for the specified measurement for each acquisition in the history. The measurement number is specified by x.
MEASUrement:MEAS1:RESUlts:HISTory:MEAN? might return MEASUREMENT:MEAS1:RESULTS:HISTORY:MEAN 2.30,2.25,2.32 indicating there are three acquisitions in the history and the mean value for measurement 1 is 2.3 V for the first acquisition, 2.25 V for the second acquisition, and 2.32 V for the third acquisition.
Returns the minimum value for the specified measurement for each acquisition in the history. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
MEASUrement:MEAS1:RESUlts:HISTory:MINimum? might return MEASUREMENT:MEAS1:RESULTS:HISTORY:MINIMUM 2.26,2.14,2.29 indicating there are three acquisitions in the history and the minimum value for measurement 1 is 2.26 V for the first acquisition, 2.14 V for the second acquisition, and 2.29 V for the third acquisition.
Returns the peak-to-peak value for the specified measurement for each acquisition in the history. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number to query. |
MEASUrement:MEAS1:RESUlts:HISTory:PK2PK? might return MEASUREMENT:MEAS1:RESULTS:HISTORY:PK2PK 0.0E+0,0.0E+0,0.0E+0 indicating there are three acquisitions in the history and the peak-to-peak value for measurement 1 for each acquisition is 0.0 V.
Returns the population value for the specified measurement for each acquisition in the history. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
MEASUrement:MEAS<x>:RESUlts:HISTory:POPUlation? MEASUREMENT:MEAS<x>:RESULTS:HISTORY:POPULATION 1,1,1
Returns a comma-separated list of the standard deviation values for each acquisition in the history.
MEASUrement:MEAS<x>:RESUlts:HISTory:STDDev? might return MEASUREMENT:MEAS1:RESULTS:HISTORY:STDDEV 0.0E+0,0.0E+0,0.0E+0
Sets or returns the center frequency value of PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Center frequency value for the PSIJ measurement. |
MEASUrement:MEAS2:RFREquency 100.00E+3 MEASUrement:MEAS2:RFREquency? might return MEASUREMENT:MEAS2:RFREquency 100.00E+3 indicating the value of center frequency is 100.00E+3 for measurement 2.
Sets or queries the center frequency value of PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Center frequency value for the PSIJ measurement. |
MEASUrement:MEAS2:RFREquency 100.00E+3 MEASUrement:MEAS2:RFREquency?
Sets or queries the ripple frequency per specified rail for Ripple measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| value | real | - | Ripple frequency value for the specified rail. |
Returns the ripple frequency setting for a specified rail of a specified measurement. The value is a frequency in the range of 1 Hz to 4 GHz.
MEASUrement:MEAS1:RIPPLEFREQ3Val 5.2e6 sets the ripple frequency for rail 3 of measurement 1 to 5.2 MHz. MEASUrement:MEAS3:RIPPLEFREQ1val? might return 1.0000E+6, indicating that the ripple frequency of rail 1 on measurement 3 is set to 1 MHz.
Sets or returns the span value of a PSIJ measurement. Requires a DPM License.
| Name | Type | Values | Description |
|---|---|---|---|
| span | real | 1 Hz - 4 GHz | Value of span for the PSIJ measurement. |
MEASUrement:MEAS2:RRANGE 100.000 MEASUrement:MEAS2:RRANGE?
Sets or returns the span value of a PSIJ measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Measurement number specified by MEAS<x>. |
| span | real | - | Span value for the PSIJ measurement. |
MEASUrement:MEAS2:RRANGE 100.000 MEASUrement:MEAS2:RRANGE?
Sets or queries the ride through standard for green power measurements. Requires option PWR.
Sets or queries the ride through standard used for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Measurement number specified by x. |
MEASUrement:MEAS1:RTSTd CEA sets the ride through standard as CEA. MEASUrement:MEAS1:RTSTd? might return MEASUrement:MEAS1:RTSTd CEA, indicating that the ride through standard is CEA.
Sets or queries the result type used to calculate the measurement. Requires the WBG-DPT option.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | The measurement number. |
| mode | enum | PERCENTAGE | ABSOLUTE | Specifies the result type as percentage or absolute. |
MEASUrement:MEAS1:RTYPe PERCENTAGE MEASUrement:MEAS1:RTYPe?
Sets or queries the result type used to calculate the measurement. Requires option WBG-DPT.
MEASUrement:MEAS1:RTYPe PERCENTAGE sets the result type as percentage. MEASUrement:MEAS1:RTYPe? might return MEASUrement:MEAS1:RTYPe ABSOLUTE, indicating that the result type is absolute.
Sets or queries the sequence of hall edges for the specified measurement number.
Sets or queries the motor Hall edges sequence for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| sequence | enum | ABC | ACB | Specifies the motor Hall edges sequence. |
MEASUrement:MEAS1:SEQuence ACB MEASUrement:MEAS1:SEQuence?
Sets or queries the line frequency for Harmonics and Ripple line frequency. The measurement number is specified by x.
MEASUrement:MEAS1:SIGNALFREQUEncy FIFTYHZ specifies the line frequency as 50 Hz for measurement 1. MEASUrement:MEAS1:SIGNALFREQUEncy? might return MEASUREMENT:MEAS1:SIGNALFREQUEncy FIFTYHZ, indicating the line frequency is 50 Hz.
Sets or queries the line frequency for Harmonics and Ripple line frequency. The measurement number is specified by x.
MEASUrement:MEAS1:SIGNALFREQUEncy FIFTYHZ specifies the line frequency as 50 Hz for measurement 1. MEASUrement:MEAS1:SIGNALFREQUEncy? might return MEASUREMENT:MEAS1:SIGNALFREQUEncy FIFTYHZ, indicating the line frequency is 50 Hz.
Sets or queries the signal type of source 1 for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| mode | enum | CLOCK | DATA | AUTO | Sets the signal type of source 1 for the measurement. |
Returns or sets the signal type used for the specified measurement. The signal type can be selected automatically or set to clock or data.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
MEASUrement:MEAS1:SIGNALType CLOCK specifies a clock signal type. MEASUrement:MEAS1:SIGNALType? might return MEASUREMENT:MEAS1:SIGNALTYPE AUTO indicating the instrument automatically selects the signal type.
Sets or queries the SJ Bandwidth value for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| value | real | - | SJ Bandwidth value for the measurement. |
MEASUrement:MEAS1:SJBANdwidth 10000 MEASUrement:MEAS2:SJBANdwidth? might return MEASUrement:MEAS2:SJBANdwidth 10E6, indicating the measurement SJ Bandwidth is 10000.
Sets or queries the SJ Bandwidth value for the specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | SJ Bandwidth value for the measurement. |
MEASUrement:MEAS1:SJBANdwidth 10000 sets the SJ Bandwidth for the measurement to 10000. MEASUrement:MEAS2:SJBANdwidth? might return MEASUrement:MEAS2:SJBANdwidth 10E6, indicating the measurement SJ Bandwidth is 10000.
Returns the measurement SJ frequency. The example shows the query response as the command followed by the frequency value.
Sets or returns the start level in absolute value for the selected measurement. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | - | Specifies the measurement number. |
| value | real | - | Specifies the value for the start level in absolute. |
MEASUrement:MEAS1:SLABs -100.0000 MEASUrement:MEAS1:SLABs? might return MEASUrement:MEAS1:SLABs -100.0000, indicating the value for the start level is -100.
Sets or returns the value for the start level in absolute. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Specifies the value for the start level in absolute. |
MEASUrement:MEAS1:SLABs -100.0000 sets the value for the start level to -100. MEASUrement:MEAS1:SLABs? might return MEASUrement:MEAS1:SLABs -100.0000, indicating the value for the start level is -100.
Sets or returns the value for the start level in percentage. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Specifies the value for the start level in percentage. |
MEASUrement:MEAS1:SLPCt 10.0000E-3 sets the value for the start level in percentage to 10.0000E-3. MEASUrement:MEAS1:SLPCt? might return MEASUrement:MEAS1:SLPCt 10.0000E-3, indicating the value for the start level in percentage is 10.0000E-3.
Sets or returns the value for the start level in percentage. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| value | real | - | Specifies the value for the start level in percentage. |
MEASUrement:MEAS1:SLPCt 10.0000E-3 MEASUrement:MEAS1:SLPCt? might return MEASUrement:MEAS1:SLPCt 10.0000E-3, indicating the value for the start level in percentage is 10.0000E-3.
Sets or returns the start level source type for measurement x. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| source type | enum | VDS | ID | VGE | VCE | IC | Start level source type to select. |
MEASUrement:MEAS1:SLTYpe ID MEASUrement:MEAS1:SLTYpe?
Sets or queries the status of the smoothing filter for a measurement. A value of 1 enables smoothing filter and 0 disables it.
| Name | Type | Values | Description |
|---|---|---|---|
| value | integer | 0 - 1 | Sets the smoothing filter state. |
MEASUrement:MEAS1:SMOOTHINGFILTER 1 MEASUrement:MEAS1:SMOOTHINGFILTER?
Sets or queries the local input source for the specified measurement. The source may be an analog channel, math channel, or reference waveform.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| source | enum | CH<x> | MATH<x> | REF<x> | Specifies the local input source. |
MEASUrement:MEAS1:SOURCE CH3 sets the local input source to channel 3. MEASUrement:MEAS1:SOURCE? might return MEASUrement:MEAS1:SOURCE CH2 indicating the local input source is channel 2.
Sets or queries the measurement source. The measurement number and source are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| source | enum | CH<x> | MATH<x> | REF<x> | Source number for the measurement. |
MEASUrement:MEAS1:SOUrce CH1 MEASUrement:MEAS1:SOUrce?
Sets or returns the span value for PSIJ measurement.
Sets or queries the specification for WBG reverse recovery measurements. Requires the WBG-DPT option.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement | integer | - | MEAS<x> specifies the measurement number. |
| specification | enum | JEP201 | JESD24 | Sets the WBG measurement specification. |
MEASUrement:MEAS1:SPECification JEP201 set the specification to JEP201 for measurement 1. MEASUrement:MEAS1:SPECification? might return MEASUrement:MEAS1:SPECification JEP201, indicating that the specification for measurement 1 is JEP201.
Sets the symbol rate for the selected measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 1.0 - 5.0e9 | Symbol rate to set. |
MEASUrement:MEAS1:SRATe 3.84e6 MEASUrement:MEAS1:SRATe? might return MEASUREMENT:MEAS1:SRATe 3.84e6
Enables or disables the rho waveform for TDR measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Specifies whether rho waveform is enabled or disabled for TDR measurement. |
MEASUrement:MEAS1:SRHo ON MEASUrement:MEAS1:SRHo? might return MEASUrement:MEAS1:SRHo OFF indicating rho waveform is disabled.
Sets or queries the nominal frequency for an SSC measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| frequency | real | Hz | Sets the nominal frequency. |
MEASUrement:MEAS1:SSC:NOMinalfreq 2.0E+9 sets the frequency to 2.0 GHz. MEASUrement:MEAS1:SSC:NOMinalfreq? might return MEASUREMENT:MEAS1:SSC:NOMINALFREQ 2.5000E+9 indicating the frequency is 2.5 GHz.
Sets or queries the frequency detection type for the measurement when the measurement type is SSC. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number. |
| mode | enum | AUTO | MANual | Frequency detection type. |
MEASUrement:MEAS1:SSC:NOMinalfreq:SELECTIONtype AUTO MEASUrement:MEAS1:SSC:NOMinalfreq:SELECTIONtype? might return MEASUREMENT:MEAS1:SSC:NOMINALFREQ:SELECTIONTYPE AUTO indicating the auto-detection type is selected.
Sets or returns the start search direction for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | FORWARD | BACKWARD | Start search direction for measurement. |
MEASUrement:MEAS1:SSDirection FORWARD MEASUrement:MEAS1:SSDirection?
Returns the pass/fail status, if applicable, for the selected measurement.
MEASUrement:MEAS1:STATUS? might return MEASUrement:MEAS1:STATUS PASS indicating that the user specified measurement limit has not been violated.
Sets or returns the value for the stop level in absolute. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The value for the stop level in absolute. |
MEASUrement:MEAS1:STLABs 5.0000 sets the value for the stop level in absolute to 5. MEASUrement:MEAS1:STLABs 5.0000? might return MEASUrement:MEAS1:STLABs 5.0000, indicating the value for the stop level in absolute is 5.
Sets or returns the value for the stop level in percentage. A WBG-DPT license is required.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Measurement number specified by <x>. |
| value | real | % | Stop level value in percentage. |
MEASUrement:MEAS1:STLPct 10.0000E-3 MEASUrement:MEAS1:STLPct?
Sets or returns the stop level source type for the specified measurement. Requires a WBG-DPT license.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| source type | enum | VDS | ID | VGE | VCE | IC | Sets the stop level source type. |
Sets or returns the stop search direction for the measurement specified by x. Requires the WBG-DPT License and is in the Wide Bandgap Analysis group.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | FORWARD | BACKWARD | Stop search direction for the measurement. |
MEASUrement:MEAS1:STSDirection FORWARD MEASUrement:MEAS1:STSDirection?
Sets or queries the source type for the specified measurement number.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | VOLTage | CURRent | DIFFERENTIAL | SINGLE | Source type to set for the measurement. |
MEASUrement:MEAS1:STYPe VOLTage MEASUrement:MEAS1:STYPe?
Returns the maximum value of the specified measurement for all acquisitions. The measurement is selected by a QString argument from a fixed list of measurement names.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies which measurement to query. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:ALLAcqs:MAXimum? "INPUT" returns the maximum value of measurement INPUT, for all acquisitions.
Returns the mean value of the specified measurement for all acquisitions.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement name whose mean value is returned. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:ALLAcqs:MEAN? "RAIL1DPMOVERSHOOT" returns the mean value of measurement RAIL1DPMOVERSHOOT, for all acquisitions.
Returns the minimum value of the specified measurement for all acquisitions.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement string for which the minimum is returned. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:ALLAcqs:MINimum? "OUTPUT7" returns the minimum value of measurement OUTPUT7, for all acquisitions.
This query returns the peak-to-peak value of the measurement specified by the string, for all acquisitions.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies which measurement string to evaluate. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:ALLAcqs:PK2PK? "OUTPUT4" returns the peak-to-peak value of measurement OUTPUT4, for all acquisitions.
Returns the population value of the specified measurement for all acquisitions. Requires the 5-DPM or 6-DPM option.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | TIE | TJBER | RJdd | DJdd | PJ | DDJ | DCD | WIDTHBER | Specifies which measurement's population value to return. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:ALLAcqs:POPUlation? "RAIL1DPMUNDERSH
Returns the standard deviation value of the specified measurement for all acquisitions. Requires option 5-DPM or 6-DPM.
| Name | Type | Values | Description |
|---|---|---|---|
| qstring | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | TIE | TJBER | RJdd | DJdd | PJ | DDJ | DCD | WIDTHBER | Specifies the measurement name. |
Returns the maximum value of the measurement specified by the string, for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement name as a quoted string. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:MAXimum? "INPUT" returns the maximum value of measurement INPUT, for the current acquisition.
This query returns the mean value of the measurement specified by the string, for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | L2LPH1VRMS | L2LPH1VCFactor | L2LPH1TruePwr | L2LPH1RePwr | L2LPH1AppPwr | L2LPH1PwrFactor | L2LPH1PhaseDiff | L2LPH1VPhase | L2LPH2VRMS | L2LPH2VCFactor | L2LPH2TruePwr | L2LPH2RePwr | L2LPH2AppPwr | L2LPH2PwrFactor | L2LPH2PhaseDiff | L2LPH2VPhase | L2LPH3VRMS | L2LPH3VCFactor | L2LPH3TruePwr | L2LPH3RePwr | L2LPH3AppPwr | L2LPH3PwrFactor | L2LPH3PhaseDiff | L2LPH3VPhase | L2NPH1VRMS | L2NPH1VCFactor | L2NPH1TruePwr | L2NPH1RePwr | L2NPH1AppPwr | L2NPH1PwrFactor | L2NPH1PhaseDiff | L2NPH1VPhase | L2NPH2VRMS | L2NPH2VCFactor | L2NPH2TruePwr | L2NPH2RePwr | L2NPH2AppPwr | L2NPH2PwrFactor | L2NPH2PhaseDiff | L2NPH2VPhase | L2NPH3VRMS | L2NPH3VCFactor | L2NPH3TruePwr | L2NPH3RePwr | L2NPH3AppPwr | L2NPH3PwrFactor | L2NPH3PhaseDiff | L2NPH3VPhase | PH1IRMS | PH1IPhase | PH1ICFactor | PH2IRMS | PH2IPhase | PH2ICFactor | PH3IRMS | PH3IPhase | PH3ICFactor | Frequency | L2LPH1F1Mag | L2LPH1F3Mag | L2LPH1THDF | L2LPH1THDR | L2LPH1RMS | L2LPH1IRMS | L2LPH1Status | L2LPH1HarmonicsNumber | L2LPH1Frequency | L2LPH1MagnitudeAbs | L2LPH1MagnitudePct | L2LPH1Phase | L2LPH1Limits | L2LPH1PassFail | L2LPH1Margin | L2LPH2F1Mag | L2LPH2F3Mag | L2LPH2THDF | L2LPH2THDR | L2LPH2RMS | L2LPH2IRMS | L2LPH2Status | L2LPH2HarmonicsNumber | L2LPH2Frequency | L2LPH2MagnitudeAbs | L2LPH2MagnitudePct | L2LPH2Phase | L2LPH2Limits | L2LPH2PassFail | L2LPH2Margin | L2LPH3F1Mag | L2LPH3F3Mag | L2LPH3THDF | L2LPH3THDR | L2LPH3RMS | L2LPH3IRMS | L2LPH3Status | L2LPH3HarmonicsNumber | L2LPH3Frequency | L2LPH3MagnitudeAbs | L2LPH3MagnitudePct | L2LPH3Phase | L2LPH3Limits | L2LPH3PassFail | L2LPH3Margin | L2NPH1F1Mag | L2NPH1F3Mag | L2NPH1THDF | L2NPH1THDR | L2NPH1RMS | L2NPH1IRMS | L2NPH1Status | L2NPH1HarmonicsNumber | L2NPH1Frequency | L2NPH1MagnitudeAbs | L2NPH1MagnitudePct | L2NPH1Phase | L2NPH1Limits | L2NPH1PassFail | L2NPH1Margin | L2NPH2F1Mag | L2NPH2F3Mag | L2NPH2THDF | L2NPH2THDR | L2NPH2RMS | L2NPH2IRMS | L2NPH2Status | L2NPH2HarmonicsNumber | L2NPH2Frequency | L2NPH2MagnitudeAbs | L2NPH2MagnitudePct | L2NPH2Phase | L2NPH2Limits | L2NPH2PassFail | L2NPH2Margin | L2NPH3F1Mag | L2NPH3F3Mag | L2NPH3THDF | L2NPH3THDR | L2NPH3RMS | L2NPH3IRMS | L2NPH3Status | L2NPH3HarmonicsNumber | L2NPH3Frequency | L2NPH3MagnitudeAbs | L2NPH3MagnitudePct | L2NPH3Phase | L2NPH3Limits | L2NPH3PassFail | L2NPH3Margin | ORDER | PH1INPwr | PH1OUTPwr | PH1Efficiency | PH2INPwr | PH2OUTPwr | PH2Efficiency | TotalEfficiency | PH1LRIPRMS | PH1LRIPPK2PK | PH2LRIPRMS | PH2LRIPPK2PK | PH3LRIPRMS | PH3LRIPPK2PK | PH1SWRIPRMS | PH1SWRIPPK2PK | PH2SWRIPRMS | PH2SWRIPPK2PK | PH3SWRIPRMS | PH3SWRIPPK2PK | TruePwrSum | RePwrSum | AppPwrSum | InPwrSum | OutPwrSum | SPEED | ACCELERATION | DIRECTION | ANGLE | TORQUE | POWER | ELECPWR | MECHPWR | SYSTEMEFFICIENCY | EON | EOFF | TDON | TDOFF | startlevel | stoplevel | TRR | QRR | TA | TB | RSF | VPEAK | IPEAK | TR | ERR | TF | TON | TOFF | IRRM | DBYDT | fft | tiespectra | subspectra | beforetie | beforepj | beforeeyeheight | beforeeyewidth | reconst | aftertie | afterpj | aftereyeheight | aftereyewidth | freq | qoss | PH1TDD | PH2TDD | PH3TDD | TDT | zmean | cmean | lmean | overshootId1 | overshootId2 | deltaIdovershoot | undershootId1 | undershootId2 | deltaIdundershoot | overshootVds1 | overshootVds2 | deltaVdsovershoot | undershootVds1 | undershootVds2 | deltaVdsundershoot | dampFactor1 | dampFactor2 | deltaDampFactor | wfm1PeakdeltaTime | wfm2PeakdeltaTime | ampValueAtCross | timeValueAtCross | Measurement name specified as a string. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:MEAN? "RAIL1DPMOVERSHOO returns the mean value of measurement RAIL1DPMOVERSHOOT, for the current acquisition.
Returns the minimum value of the specified measurement for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement whose current-acquisition minimum value is returned. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:MINimum? "OUTPUT7" returns the minimum value of measurement OUTPUT7, for the current acquisition.
This query returns the peak-to-peak value of the measurement specified by the string, for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement path and filename in quotes. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:PK2PK? "OUTPUT4" returns the peak-to-peak value of measurement OUTPUT4, for the current acquisition.
Returns the population value of the specified measurement for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement whose population value is returned. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:POPUlation? "RAIL1DPMUN
Returns the standard deviation value of the measurement specified by the string, for the current acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | enum | INPUT | OUTPUT1 | OUTPUT2 | OUTPUT3 | OUTPUT4 | OUTPUT5 | OUTPUT6 | OUTPUT7 | RAIL1DPMOVERSHOOT | RAIL1DPMUNDERSHOOT | RAIL1FREQUENCY | RAIL1PK2PK | RAIL1RMS | RAIL1RMSFULL | RAIL2FREQUENCY | RAIL2PK2PK | RAIL2RMS | RAIL2RMSFULL | RAIL3FREQUENCY | RAIL3PK2PK | RAIL3RMS | RAIL3RMSFULL | RAIL4FREQUENCY | RAIL4PK2PK | RAIL4RMS | RAIL4RMSFULL | RAIL5FREQUENCY | RAIL5PK2PK | RAIL5RMS | RAIL5RMSFULL | RAIL6FREQUENCY | RAIL6PK2PK | RAIL6RMS | RAIL6RMSFULL | RAIL7DPMOVERSHOOT | RAIL7DPMUNDERSHOOT | RAIL7FREQUENCY | RAIL7PK2PK | RAIL7RMS | RAIL7RMSFULL | Specifies the measurement name for which the standard deviation is returned. |
MEASUrement:MEAS1:SUBGROUP:RESUlts:CURRentacq:STDDev? "RAIL7PK2PK"
Sets or queries the speed measurement units for measurement x. The allowed units are RPM or HZ.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| units | enum | RPM | HZ | Sets the speed measurement units. |
MEASUrement:MEAS1:SUNits HZ sets the speed measurement units as HZ. MEASUrement:MEAS1:SUNits? might return MEASUrement:MEAS1:SUNits HZ, indicating thatthe speed measurement units is HZ.
Sets or queries the TBER value for the measurement. Measurements are specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| value | string | - | TBER value for the measurement as a quoted string. |
MEASUrement:MEAS2:TBER "1.2E-7" MEASUrement:MEAS2:TBER?
Sets the average clock period value for the specified measurement. The value is a floating-point number representing the DDR average clock period in seconds.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| <NR3> | real | s | Floating point number representing the DDR average clock period. |
MEASurement:MEAS7:TCKAVG 2.5E-9 sets the average clock period value as 3.2 ns for measurement 7. MEASurement:MEAS2:TCKAVG? might return MEASurement:MEAS2:TCKAVG 2.0E-9 indicating that average clock period is set to 2.0 ns for measurement 2.
Sets or queries the measurement Torque Constant.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | 0 - 100 | Specifies the measurement number. |
| current multiplier value | real | 0 - 100 | Specifies the current multiplier value of the measurement. |
MEASurement:MEAS7:TCONstant 15.2 specifies the current multiplier value for measurement 7 as 15.2. MEASurement:MEAS2:TCONstant? might return MEASurement:MEAS2:TCONstant 15.2, indicating the current multiplier value for measurement 2 is 15.2.
Executes the preset for TDR measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | - | - | Specifies the measurement number. |
| state | enum | EXECUTE | Executes the preset for TDR measurement. |
:MEASUrement:MEAS1:TDRPreset EXECUTE executes the preset for TDR measurement.
Sets or queries the Timing mode for the specified DDR measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | EACHCLOCKCYCLE | TWOCLOCKCYCLES | Selects whether the DDR Timing Mode uses each clock cycle at a time or two cycles at a time. |
MEASurement:MEAS1:TIMINGMode EACHCLOCKCYCLE MEASurement:MEAS1:TIMINGMode?
Sets or queries whether histogram center is percentage relative to unit amplitude or an absolute value for eye height measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | PERCent | ABSolute | Selects how the histogram center is interpreted. |
MEASUrement:MEAS1:TLEVel PERCent MEASUrement:MEAS1:TLEVel?
Sets or queries the torque method for measurement x. Requires the IMDA-MECH license on MSO 5, 6, and 6B series instruments.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| method | enum | SENSOR | CURRENT | Selects the torque method. |
MEASurement:MEAS7:TMEthod SENSOR MEASurement:MEAS2:TMEthod?
Sets or queries the 'to edge' type for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| mode | enum | SAMEas | OPPositeas | RISe | FALL | BOTH | Selects the edge type for the measurement. |
MEASUrement:MEAS1:TOEdge FALL MEASUrement:MEAS1:TOEdge?
Sets or queries the direction used for the To Edge search for measurement <x>. The direction can be forward or backward.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | FORWard | BACKWard | Search direction to the edge. |
MEASUrement:MEAS1:TOEDGESEARCHDIRect FORWARD specifies a forward search to the edge. MEASUrement:MEAS1:TOEDGESEARCHDIRect? might return MEASUREMENT:MEAS1:TOEDGESEARCHDIRECT FORWARD indicating the instrument will search in the forward direction for the to edge.
Sets or queries the DDR digital measurement logic 1 source To Symbol. This command is available only with option 6-DBDDR3 on a 6 Series MSO instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| mode | enum | H | L | X | Sets the logic source 1 To Symbol to H (High), L (Low), or X (Don't care). |
Sets the ToSymbol MeasureAT value for measurement x. This command is available only on a 6 Series MSO with option 6-DBDDR3.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | Start | Stop | ClockEdge | Sets the ToSymbol MeasureAT selection. |
MEASUrement:MEAS1:ToSYmbol:MEASUREAT Start MEASUrement:MEAS1:ToSYmbol:MEASUREAT?
Sets or queries the transition edges flag for the measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | <NR1> | OFF | ON | Controls whether the measurement is computed on all edges or only following a double transition. |
Sets or queries the measurement type for measurement x.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | ACCOMMONMODE | ACPR | ACRMS | AMPLITUDE | AREA | BASE | BITAMPLITUDE | BITHIGH | BITLOW | BURSTWIDTH | COMMONMODE | CPOWER | DATARATE | DCD | DDJ | DDRAOS | DDRAOSPERTCK | DDRAOSPERUI | DDRAUS | DDRAUSPERTCK | DDRAUSPERUI | DDRHOLDDIFF | DDRSETUPDIFF | DDRTCHABS | DDRTCHAVERAGE | DDRTCKAVERAGE | DDRTCLABS | DDRTCLAVERAGE | DDRTERRMN | DDRTERRN | DDRTJITCC | DDRTJITDUTY | DDRTJITPER | DDRTPST | DDRTRPRE | DDRTWPRE | DDRVIXAC | DDRTDQSCK | DELAY | DJ | DJDIRAC | DPMOVERSHOOT | DPMPSIJ | DPMUNDERSHOOT | DPMRIPPLE | DPMTURNOFFTIME | DPMTURNONTIME | GPLVRT | GPHVRT | EYEHIGH | EYELOW | FALLSLEWRATE | FALLTIME | FREQUENCY | F2 | F4 | F8 | HIGH | HEIGHT | HEIGHTBER | HIGHTIME | HOLD | IMDAANGLE | IMDADIRECTION | IMDADQ0 | IMDAEFFICIENCY | IMDAHARMONICS | IMDAMECHPWR | IMDAPOWERQUALITY | IMDASPEED | IMDASYSEFF | IMDATORQUE | ISI | JITTERSUMMARY | J2 | J9 | LOW | LOWTIME | MAXIMUM | MEAN | MINIMUM | NDUtY | NPERIOD | NPJ | NOVERSHOOT | NWIDTH | OBW | PATTERNLENGTH | PDUTTY | PERIOD | PHASE | PHASENOISE | PJ | PK2Pk | POVERSHOOT | PWIDTH | QFACTOR | RDSON | RISESLEWRATE | RISETIME | RJ | RJDIRAC | RMS | SJFREQ | SRJ | SSCFREQDEV | SSCMODRATE | SSCSLEWRATE | SETUP | SKEW | TDR | TIE | TIMEOUTSIDELEVEL | TJBER | TNTRATIO | TOP | UNITINTERVAL | VDIFFXOVR | WBGDDT | WBGDIODEDDT | WBGEOFF | WBGEON | WBGERR | WBGIPEAK | WBGIRRM | WBGQOSS | WBGQRR | WBGTDOFF | WBGTDON | WBGTF | WBGTON | WBGTOFF | WBGTR | WBGTRR | WBGTDT | WBGVPEAK | WIDTH | WIDTHBER | Measurement type to set or query for the specified measurement. |
Sets or queries whether histogram center is percentage relative to unit interval or an absolute value for eye width measurement.
Sets or returns the wait time for measurement <x>. The wait time is specified as an NR2 value in the range of 1 s to 500 s.
| Name | Type | Values | Description |
|---|---|---|---|
| wait time | real | 1 - 500 | Wait time for measurement <x>. |
MEASUrement:MEAS1:WAITTime 60 MEASUrement:MEAS3:WAITTime?
Sets or returns the burst count for WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| count | integer | NR3 | Burst count for the WBG measurement. |
MEASUrement:MEAS1:WBG:BCOunt 1000 specifies the burst count as 1000 for WBG measurement 1. MEASUrement:MEAS1:WBG:BCOunt? might return :MEASUrement:MEAS1:WBG:BCOunt 1000 indicating the burst count is 1000 for WBG measurement 1.
Sets or queries the delay for a WBG measurement. The slice shows both a setter form and a query form, but does not document a return value for the query.
| Name | Type | Values | Description |
|---|---|---|---|
| value | enum | ON | OFF | Enables or disables the delay setting. |
MEASUrement:MEAS1:WBG:BDELay 1.0000E-3 specifies the burst delay as 1.0000E-3 for WBG measurement 1. MEASUrement:MEAS<x>:WBG:BDELay? might return :MEASUrement:MEAS1:WBG:BDELay 1.0000E-3 indicating the burst delay is 1.0000E-3 for WBG measurement 1.
Sets or queries the WBG measurement delay. The query returns the current delay value in seconds.
Enables or disables generator source one for WBG measurement. Requires option WBG-DPT.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Selects whether generator source one is enabled or disabled. |
MEASUrement:MEAS1:WBG:ESONe ON MEASUrement:MEAS1:WBG:ESONe?
Returns the WBG EstWo state for the specified measurement. The example indicates it may return OFF when generator source two is disabled.
Sets or queries the generator address for a WBG measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Specifies the generator address for WBG measurements. |
MEASUrement:MEAS2:WBG:GENAddress "134.64.246.214" MEASUrement:MEAS2:WBG:GENAddress?
Sets or queries the high voltage of the generator for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | integer | - | Specifies the measurement number. |
| GSOurce<x> | integer | - | Specifies the generator source. |
| voltage | real | - | High voltage of the generator for WBG measurements. |
MEASUrement:MEAS2:WBG:GSOurce1:HIGH 2.5000 MEASUrement:MEAS2:WBG:GSOurce1:HIGH? might return MEASUREMENT:MEAS2:WBG:GSOurce1:HIGH 2.5000
Sets or queries the load type of the generator for WBG measurements.
MEASUrement:MEAS2:WBG:GSOurce1:LOAD FIFTY MEASUrement:MEAS2:WBG:GSOurce1:LOAD?
Sets or queries the low voltage of the generator for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| low voltage | real | - | Low voltage for WBG measurements. |
MEASUrement:MEAS2:WBG:GSOurce1:LOW 0.0E+0 MEASUrement:MEAS2:WBG:GSOurce1:LOW?
Sets or queries the pulse gap of the generator for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| measurement number | integer | 1 - 8 | Specifies the measurement number. |
| generator source | integer | - | Specifies the generator source. |
| pulse number | integer | 1 - 8 | Specifies the number of pulse. |
| value | real | - | Specifies the pulse gap for WBG measurements. |
MEASUrement:MEAS2:WBG:GSOurce1:PG8Val 150.0000E-6 MEASUrement:MEAS2:WBG:GSOurce1:PG8Val?
Sets or queries the pulse width of the generator for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| GSOurce<x> | - | - | Specifies the generator source. |
| PG<x> | integer | 1 - 8 | Specifies the number of pulse. |
| pulse gap | real | - | Specifies the pulse gap for WBG measurements. |
MEASUrement:MEAS2:WBG:GSOurce1:PW1Val 60.0000E-9 MEASUrement:MEAS2:WBG:GSOurce1:PW1Val?
Sets or returns the generator type for WBG measurements.
MEASUrement:MEAS1:WBG:GTYPe AFG31000 MEASUrement:MEAS1:WBG:GTYPe?
Sets or returns the number of pulse of AFG for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| NR1 | integer | - | Specifies the number of pulse of AFG to generate pulse signal for WBG measurements. |
MEASUrement:MEAS2:WBG:NPULs? might return MEASUREMENT:MEAS2:WBG:NPULs 8 indicating the number of pulse of AFG is 8 for measurement 2.
Sets or returns the trigger interval of AFG for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| MEAS<x> | - | - | Specifies the measurement number. |
| pulse gap | real | - | Specifies the pulse gap of AFG for WBG measurements. |
MEASUrement:MEAS2:WBG:TIMer 500.0000 MEASUrement:MEAS2:WBG:TIMer?
Sets or queries the width for the specified measurement number. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| value | real | - | Value for the width. |
MEASUrement:MEAS1:WIDTh 10 sets the width as 10% for measurement 1. MEASUrement:MEAS1:WIDTh? might return MEASUrement:MEAS1:WIDTh 10, indicating width is set to 10% for measurement 1.
Sets or queries the window length for the specified measurement. The measurement number is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the measurement number. |
| window length | real | - | The value for the window length. |
MEASUrement:MEAS1:WINDOWLENgth 10 sets the window length to 10. MEASUrement:MEAS1:WINDOWLENgth? might return MEASUREMENT:MEAS1:WINDOWLENGTH 10.0000 indicating the window length is 10.
Sets or queries the global range maximum value.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Maximum measurement range limit value. |
MEASUREMENT:MEASRANGE:MAX 1.5 sets the maximum range limit to 1.5 V. MEASUREMENT:MEASRANGE:MAX? might return MEASUREMENT:MEASRANGE:MAX 1.0000 indicating that the maximum range limit is 1.0 V.
Sets or queries the global range minimum value for measurements.
Sets or queries the global range state for measurements. When enabled, measurement results are limited to values between the range minimum and maximum.
MEASUREMENT:MEASRANGE:STATE? might return MEASUREMENT:MEASRANGE:STATE 0 indicating that the measurement results are not limited.
Sets or queries the global mechanical Index Z source.
MEASUrement:MECH:EINDexz ON
Sets or queries the measurement gear ratio. The gear ratio value is used for a specified measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | 0.001 - 1000 | Gear ratio value for a specified measurement. |
MEASUREMENT:MECH:GRATIO? might return MEASUREMENT:MECH:GRATio 1.000E-3, indicating the gear ratio value is 1.000E-3.
Sets or queries the global mechanical measurement results units.
| Name | Type | Values | Description |
|---|---|---|---|
| units | enum | NM | OZINCH | FTLB | INCHLB | DEGREES | RADIANS | Specifies the results units of mechanical torque measurement. |
MEASUrement:MECH:MUNits NM specifies the results units of mechanical Torque measurement as NM.
Sets or queries the measurement number of pole pairs.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | integer | 1 - 20 | Defines the number of pole pairs for the specified measurement. |
MEASUrement:MECH:PPAirs 4 defines the number of pole pairs as 4. MEASUrement:MECH:PPAirs? might return MEASUREMENT:MECH:PPAirs 4 indicating the number of pole pairs is 4.
Sets or queries the global pulses per rotation of the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| pulses per rotation | integer | 1 - 100000 | Defines the pulses per rotation of the measurement. |
MEASUrement:MECH:PPRotation 25 defines the pulses per rotation of the measurement as 25. MEASUrement:MECH:PPRotation? might return MEASUREMENT:MECH:PPRotation 25, indicating the pulses per rotation of the measurement is 25.
Sets or queries the global mechanical source waveform for the specified source index. The source can be an analog channel, math waveform, reference waveform, or digital channel.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Source index used in the MECH source mnemonic. |
| source | enum | CH<x> | MATH<x> | REF<x> | CH<x>_D<x> | Waveform source to assign. |
MEASUrement:MECH:SOUrce2 CH2 MEASUrement:MECH:SOUrce2?
Sets or queries the measurement sensor type.
MEASUrement:MECH:STYPe HSENSOR MEASUrement:MECH:STYPe?
Sets or queries the minimum number of unit intervals required for BUJ analysis.
MEASUREMENT:MINUI 1.0000E+6 MEASUREMENT:MINUI?
Sets or queries the global population limit state for the measurement.
MEASUREMENT:POPULATION:LIMIT:STATE 1 turns on the population limit. MEASUREMENT:POPULATION:LIMIT:STATE? might return MEASUREMENT:POPULATION:LIMIT:STATE 0 indicating the population limit is off.
Returns the current population limit value.
Sets or queries the value used as the high reference level of the falling edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | V | The high reference level of the falling edge when the measurement's ref level method is set to absolute. |
MEASUrement:REFLevels:ABSolute:FALLHigh 1.5 MEASUrement:REFLevels:ABSolute:FALLHigh?
Sets or queries the value used as the low reference level of the falling edge when the measurement ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | V | The value used as the low reference level of the falling edge. |
MEASUrement:REFLevels:ABSolute:FALLLow -1.5 sets the low reference level to -1.5 V. MEASUrement:REFLevels:ABSolute:FALLLow? might return MEASUREMENT:REFLEVELS:ABSOLUTE:FALLLOW -1.0000 indicating the low reference level is -1.0 V.
Sets or queries the value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | The mid reference level of the falling edge. |
MEASUrement:REFLevels:ABSolute:FALLMid 10.0E-3 MEASUrement:REFLevels:ABSolute:FALLMid?
Sets or queries the hysteresis of the reference level when the measurement's ref level method is set to absolute.
Sets or queries the value used as the high reference level of the rising edge when the measurement ref level method is set to absolute.
MEASUrement:REFLevels:ABSolute:RISEHigh 1.5 sets the high reference to 1.5 V. MEASUrement:REFLevels:ABSolute:RISEHigh? might return MEASUREMENT:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000 indicating the high reference is 1.0 V.
Sets or queries the low reference level of the rising edge when the measurement reference level method is set to absolute.
MEASUrement:REFLevels:ABSolute:RISELow -1.5 sets the high reference to 1.5 V. MEASUrement:REFLevels:ABSolute:RISELow? might return MEASUREMENT:REFLEVELS:ABSOLUTE:RISELow -1.0000 indicating the high reference is -1.0 V.
Sets or queries the value used as the mid reference level of the rising edge when the measurement ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The mid reference level of the rising edge. |
MEASUrement:REFLevels:ABSolute:RISEMid 10.0E-3 sets the mid reference to 10.0 mV. MEASUrement:REFLevels:ABSolute:RISEMid? might return MEASUREMENT:REFLEVELS:ABSOLUTE:RISEMID 0.0E+0 indicating the mid reference is 0.0 V.
Sets or queries the reference level type for the measurement.
MEASUrement:REFLevels:ABSolute:TYPE? might return MEASUREMENT:REFLEVELS:ABSOLUTE:TYPE SAME indicating the absolute levels are set the same.
Sets or queries the method used to calculate the TOP and BASE used for measurement reference levels.
Sets or queries how often reference levels are calculated for measurements. The command selects whether reference levels are updated on every acquisition or only after the first acquisition following a statistics reset.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | LATCh | CONTinuous | How often reference levels are calculated. |
Sets or queries how often reference levels are calculated. CONTinuous calculates reference levels on every acquisition, while LATCh calculates them only on the first acquisition after a statistics reset.
MEASUREMENT:REFLEVELS:JITTERMODE CONTINUOUS MEASUREMENT:REFLEVELS:JITTERMODE?
Sets or queries the method used to calculate reference levels for the measurement. Percent calculates levels relative to HIGH and LOW; Absolute sets them explicitly using the REFLevel:ABSolute commands.
MEASUrement:REFLevels:METHod ABSOLUTE MEASUrement:REFLevels:METHod?
Sets or queries the method used to calculate reference levels for the measurement.
MEASUrement:REFLevels:METHod ABSOLUTE MEASUrement:REFLevels:METHod?
Sets or queries how often reference levels are calculated.
Sets or queries how often reference levels are calculated.
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. The percentage is defined such that 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | 1 - 99 | Percentage used to calculate the high reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLHigh 90 MEASUrement:REFLevels:PERCent:FALLHigh? might return MEASUREMENT:REFLEVELS:PERCENT:FALLHIGH 80.0000
Sets or queries the percentage used to calculate the high reference level of the falling edge when the measurement ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | % | Percentage used to calculate the high reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLHigh 90 MEASUrement:REFLevels:PERCent:FALLHigh?
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percent | real | 1 - 99 | Percentage used to calculate the mid reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLLow 10 sets the low reference level to 10%. MEASUrement:REFLevels:PERCent:FALLLow? might return MEASUREMENT:REFLEVELS:PERCENT:FALLLOW 20.0000 indicating the low reference level is 20%.
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | % | Percentage used to calculate the mid reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLLow 10 sets the low reference level to 10%. MEASUrement:REFLevels:PERCent:FALLLow? might return MEASUREMENT:REFLEVELS:PERCENT:FALLLOW 20.0000 indicating the low reference level is 20%.
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | % | Percentage used to calculate the mid reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLMid 55 MEASUrement:REFLevels:PERCent:FALLMid? might return MEASUREMENT:REFLEVELS:PERCENT:FALLMID 50.0000
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement's ref level method is set to percent. The manual notes that 99% equals TOP and 1% equals BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | % | Percentage used to calculate the mid reference level of the falling edge. |
MEASUrement:REFLevels:PERCent:FALLMid 55 MEASUrement:REFLevels:PERCent:FALLMid?
Sets or queries the percentage used to calculate the hysteresis of the reference level when the measurement's ref level method is set to percent. 100% is equal to MAX and 1% is equal to MIN.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | 1 - 100 | Percentage used to calculate the hysteresis of the reference level. |
Sets or queries the percentage used to calculate the hysteresis of the reference level when the measurement's ref level method is set to percent. 100% is equal to MAX and 1% is equal to MIN.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement's ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| nr3 | real | % | Percentage used to calculate the high reference level of the rising edge. |
MEASUrement:REFLevels:PERCent:RISEHigh 90 sets the high reference level to 90%. MEASUrement:REFLevels:PERCent:RISEHigh? might return MEASUREMENT:REFLEVELS:PERCENT:RISEHIGH 80.0000 indicating the high ref level is 80%.
Returns or sets the percentage used to calculate the high reference level of the rising edge when the measurement ref level method is set to percent.
MEASUrement:REFLevels:PERCent:RISEHigh 90 sets the high reference level to 90%. MEASUrement:REFLevels:PERCent:RISEHigh? might return MEASUREMENT:REFLEVELS:PERCENT:RISEHIGH 80.0000 indicating the high ref level is 80%.
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement's ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | 1 - 99 | The percentage used to calculate the low reference level of the rising edge. |
MEASUrement:REFLevels:PERCent:RISELow 10 sets the low reference level to 10%. MEASUrement:REFLevels:PERCent:RISELow? might return MEASUREMENT:REFLEVELS:PERCENT:RISELOW 20.0000 indicating the low reference level is 20%.
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | % | Percentage used to calculate the low reference level of the rising edge. |
MEASUrement:REFLevels:PERCent:RISELow 10 sets the low reference level to 10%. MEASUrement:REFLevels:PERCent:RISELow? might return MEASUREMENT:REFLEVELS:PERCENT:RISELOW 20.0000 indicating the low reference level is 20%.
Sets or queries the value used as the high reference level of the falling edge when the measurement's ref level method is set to absolute.
Sets or queries the value used as the high reference level of the falling edge when the measurement reference level method is set to absolute.
Sets or queries the value used as the high reference level of the falling edge when the measurement's reference level method is set to absolute.
Sets or queries the value used as the high reference level of the rising edge when the measurement's reference level method is set to absolute.
Sets or queries the reference level percent type for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | TENNinety | TWENtyeighty | CUSTom | Selects the reference level percent type. |
MEASUrement:REFLevels:PERCent:TYPE TENNINETY MEASUrement:REFLevels:PERCent:TYPE? might return MEASUREMENT:REFLEVELS:PERCENT:TYPE CUSTOM
Sets or queries the reference level percent type for the measurement.
MEASUrement:REFLevels:PERCent:TYPE TENNINETY MEASUrement:REFLevels:PERCent:TYPE? might return MEASUREMENT:REFLEVELS:PERCENT:TYPE CUSTOM
Sets or queries the shared reference level method used for sources of measurement calculations.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | GLOBal | PERSource | Selects whether reference levels are shared across measurements or used on individual measurements. |
MEASUREMENT:REFLEVELS:TYPE PERSource causes reference levels to be used on individual measurements. MEASUREMENT:REFLEVELS:TYPE? might return MEASUREMENT:REFLEVELS:TYPE GLOBAL indicating reference levels are shared across measurements.
Sets or queries the shared reference level method used for sources of measurement calculations.
MEASUREMENT:REFLEVELS:TYPE PERSource causes reference levels to be used on individual measurements. MEASUREMENT:REFLEVELS:TYPE? might return MEASUREMENT:REFLEVELS:TYPE GLOBAL indicating reference levels are shared across measurements.
Sets or queries the low reference level used for the falling edge when the measurement ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | V | The value used as the low reference level of the falling edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:FALLLow -1.5 sets the low reference level to -1.5 V. MEASUrement:REF1:REFLevels:ABSolute:FALLLow? might return MEASUREMENT:REF1:REFLEVELS:ABSOLUTE:FALLLOW -1.0000 indicating the low reference level is -1.0 V.
Sets or queries the value used as the low reference level of the falling edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The value used as the low reference level of the falling edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:FALLLow -1.5 sets the low reference level to -1.5 V. MEASUrement:REF1:REFLevels:ABSolute:FALLLow? might return MEASUREMENT:REF1:REFLEVELS:ABSOLUTE:FALLLOW -1.0000 indicating the low reference level is -1.0 V.
Sets or queries the value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute. |
Sets or queries the value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | V | Value used as the mid reference level of the falling edge when the measurement's ref level method is set to absolute. |
Sets or queries the value of the hysteresis of the reference level when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | The hysteresis value of the reference level. |
MEASUrement:REF1:REFLevels:ABSolute:HYSTeresis 20.0E-3 MEASUrement:REF1:REFLevels:ABSolute:HYSTeresis?
Sets or queries the hysteresis of the reference level when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| hysteresis | real | - | Value of the hysteresis of the reference level when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:HYSTeresis 20.0E-3 MEASUrement:REF1:REFLevels:ABSolute:HYSTeresis?
Sets or queries the value used as the high reference level of the rising edge when the measurement's reference level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The value used as the high reference level of the rising edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:RISEHigh 1.5 sets the reference level to 1.5 V. MEASUrement:REF1:REFLevels:ABSolute:RISEHigh? might return MEASUREMENT:REF1:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000 indicating the reference level is 1.0 V.
Sets or queries the value used as the high reference level of the rising edge when the measurement's reference level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | The value used as the high reference level of the rising edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:RISEHigh 1.5 sets the reference level to 1.5 V. MEASUrement:REF1:REFLevels:ABSolute:RISEHigh? might return MEASUREMENT:REF1:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000 indicating the reference level is 1.0 V.
Sets or queries the low reference level of the rising edge for a measurement when the reference level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| value | real | - | Value used as the low reference level of the rising edge. |
MEASUrement:REF1:REFLevels:ABSolute:RISELow -1.5 MEASUrement:REF1:REFLevels:ABSolute:RISELow?
Sets or queries the value used as the low reference level of the rising edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Value used as the low reference level of the rising edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:RISELow -1.5 MEASUrement:REF1:REFLevels:ABSolute:RISELow?
Sets or queries the value used as the mid reference level of the rising edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | Value used as the mid reference level of the rising edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:RISEMid 10.0E-3 MEASUrement:REF1:REFLevels:ABSolute:RISEMid?
Sets or queries the value used as the mid reference level of the rising edge when the measurement's ref level method is set to absolute.
| Name | Type | Values | Description |
|---|---|---|---|
| <NR3> | real | - | The value used as the mid reference level of the rising edge when the measurement's ref level method is set to absolute. |
MEASUrement:REF1:REFLevels:ABSolute:RISEMid 10.0E-3 sets the reference level to 10.0 mV. MEASUrement:REF1:REFLevels:ABSolute:RISEMid? might return MEASUREMENT:REF1:REFLEVELS:ABSOLUTE:RISEMID 0.0E+0 indicating the mid reference level is 0.0 V.
Sets or queries the reference level type for the measurement. In absolute mode, SAME sets the absolute levels the same and UNIQue allows them to be set independently.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SAME | UNIQue | Reference level type for the measurement. |
Sets or queries the reference level type for the measurement. SAME specifies that the absolute levels are set the same, and UNIQue specifies that the absolute levels can be set independently.
Sets or queries the method used to calculate the TOP and BASE values for reference levels used in measurements.
MEASUrement:REF1:REFLevels:BASETop MINMAX MEASUrement:REF1:REFLevels:BASETop?
Sets or queries the method used to calculate the TOP and BASE values used for reference levels for the measurement.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | AUTO | MINMax | MEANhistogram | MODEhistogram | EYEhistogram | Reference level method to use for TOP and BASE calculation. |
MEASUrement:REF1:REFLevels:BASETop MINMAX MEASUrement:REF1:REFLevels:BASETop?
Sets or queries the method used to calculate reference levels for the measurement. The method determines whether reference levels are defined as percentages relative to HIGH/LOW or as explicit absolute values.
Sets or queries the method used to calculate reference levels for the measurement. Percent uses HIGH/LOW percentages defined by the REFLevel:PERCent commands; Absolute sets explicit reference levels using the REFLevel:ABSolute commands.
Sets or queries the method used to calculate reference levels for the measurement. The percent method calculates levels relative to HIGH and LOW; the absolute method sets levels explicitly.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | PERCent | ABSolute | Reference level calculation method. |
Sets or queries the method used to calculate reference levels for the measurement.
Sets or queries the percentage used to calculate the low reference level of the falling edge when the measurement ref level method is set to percent. 99% corresponds to TOP and 1% to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 1 - 99 | Percentage used to calculate the low reference level. |
MEASUrement:REF1:REFLevels:PERCent:FALLLow 5 MEASUrement:REF1:REFLevels:PERCent:FALLLow? might return MEASUREMENT:REF1:REFLEVELS:PERCENT:FALLLOW 10.0000
Sets or queries the percentage used to calculate the low reference level of the falling edge when the measurement ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Percentage used to calculate the low reference level. |
MEASUrement:REF1:REFLevels:PERCent:FALLLow 5 MEASUrement:REF1:REFLevels:PERCent:FALLLow?
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement reference level method is set to percent. The percentage is defined with 99% equal to TOP and 1% equal to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | Percentage used to calculate the mid reference level of the falling edge. |
Sets or queries the percentage used to calculate the mid reference level of the falling edge when the measurement's ref level method is set to percent. The percentage is defined relative to TOP and BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | - | Percentage used to calculate the mid reference level of the falling edge. |
Sets or queries the percentage used to calculate the hysteresis of the reference level when the measurement ref level method is set to percent. The manual notes that 99% is equal to MAX and 1% is equal to MIN.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | 1 - 99 | Percentage used to calculate the hysteresis of the reference level. |
MEASUrement:REF1:REFLevels:PERCent:HYSTeresis 2 sets the hysteresis to 2%. MEASUrement:REF1:REFLevels:PERCent:HYSTeresis? might return MEASUREMENT:REF1:REFLEVELS:PERCENT:HYSTERESIS 5.0000 indicating the hysteresis is 5%.
Sets or queries the percentage used to calculate the hysteresis of the reference level when the measurement's ref level method is set to percent. The manual notes that 99% is equal to MAX and 1% is equal to MIN.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 1 - 99 | Percentage used to calculate the hysteresis of the reference level. |
MEASUrement:REF1:REFLevels:PERCent:HYSTeresis 2 sets the hysteresis to 2%. MEASUrement:REF1:REFLevels:PERCent:HYSTeresis? might return MEASUREMENT:REF1:REFLEVELS:PERCENT:HYSTERESIS 5.0000 indicating the hysteresis is 5%.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement's ref level method is set to percent. 99% corresponds to TOP and 1% to BASE.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | 1 - 99 | Percentage used to calculate the high reference level of the rising edge. |
MEASUrement:REF1:REFLevels:PERCent:RISEHigh 95 sets the reference level to 95%.
Sets or queries the percentage used to calculate the high reference level of the rising edge when the measurement's ref level method is set to percent. 99% is equal to TOP and 1% is equal to BASE.
MEASUrement:REF1:REFLevels:PERCent:RISEHigh 95 sets the reference level to 95%.
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement's ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | % | The percentage used to calculate the low reference level of the rising edge. |
MEASUment:REF1:REFLevels:PERCent:RISELow 5 MEASUment:REF1:REFLevels:PERCent:RISELow?
Sets or queries the percentage used to calculate the low reference level of the rising edge when the measurement's ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| percentage | real | 1 - 99 | Percentage used to calculate the low reference level of the rising edge. |
MEASUrement:REF1:REFLevels:PERCent:RISELow 5 MEASUrement:REF1:REFLevels:PERCent:RISELow? might return MEASUREMENT:REF1:REFLEVELS:PERCENT:RISELOW 10.0000 indicating the reference level is 10%.
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement's ref level method is set to percent.
| Name | Type | Values | Description |
|---|---|---|---|
| NR3 | real | - | The percentage used to calculate the mid reference level of the rising edge. |
MEASUrement:REF1:REFLevels:PERCent:RISEMid 55 MEASUrement:REF1:REFLevels:PERCent:RISEMid?
Sets or queries the percentage used to calculate the mid reference level of the rising edge when the measurement ref level method is set to percent.
MEASUrement:REF1:REFLevels:PERCent:RISEMid 55 MEASUrement:REF1:REFLevels:PERCent:RISEMid? might return MEASUREMENT:REF1:REFLEVELS:PERCENT:RISEMID 50.0000 indicating the mid reference level is 50%.
Sets or queries the reference level percent type for the measurement.
Sets or queries the reference level percent type for the measurement.
Sets or queries the starting acquisition number for transferring measurement history results.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | integer | 1 - the number of history acquisitions | The first acquisition that will be transferred. |
MEASUrement:RESUlts:HISTory:STARt 25 MEASUrement:RESUlts:HISTory:STARt? might return MEASUrement:RESUlts:HISTory:STARt 10 indicating that measurement history results transfer will begin at acquisition 10.
Sets or queries the starting acquisition number for transferring measurement history results.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | integer | 1 | The first acquisition that will be transferred. |
MEASUrement:RESUlts:HISTory:STARt 25 MEASUrement:RESUlts:HISTory:STARt?
Sets or queries the last history acquisition that will be transferred. A value of 0 indicates that the stop position is the last history acquisition.
| Name | Type | Values | Description |
|---|---|---|---|
| NR1 | integer | 0 - number of history acquisitions | Last acquisition to transfer. |
MEASUrement:RESUlts:HISTory:STOP 50 MEASUrement:RESUlts:HISTory:STOP?
Returns the last history acquisition transferred by measurement history results. A special value of 0 indicates that the stop position is always the last history acquisition.
MEASUrement:RESUlts:HISTory:STOP? might return MEASUrement:RESUlts:HISTory:STOP 0 indicating that measurement history results transfer will end with the last history acquisition.
Turns cycle-to-cycle measurement statistics tracking on or off. It affects computation and display of cycle-cycle statistics in the Measurement Result table after enabling and after new data is acquired and measured.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | OFF | ON | 0 | 1 | Turns cycle-to-cycle measurement statistics tracking on or off. |
MEASUREMENT:STATISTICS:CYCLEMODE OFF turns off statistics for all measurements.
Turns cycle-to-cycle measurement statistics tracking on or off. It affects computation and display of cycle-cycle statistics in the Measurement Result table after enabling and after new data is acquired.
MEASUREMENT:STATISTICS:CYCLEMODE OFF turns off statistics for all measurements.
Sets or returns the type of the Power device used for WBG measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| device type | enum | IGBT | MOSFET | Specifies the type of the Power device. |
MEASUREMENT:WBG:PDEVICE MOSFET MEASUREMENT:WBG:PDEVICE?
Sets or returns the type of the Power device used for wide-bandgap measurements.
| Name | Type | Values | Description |
|---|---|---|---|
| device type | enum | IGBT | MOSFET | Specifies the type of the Power device. |
MEASUREMENT:WBG:PDEVICE MOSFET MEASUREMENT:WBG:PDEVICE?
Returns measurement results for the specified measurement slot. This command supports Operation Complete when used in single sequence acquisition mode or during waveform recall.
Sets the measurement gating mode. The factory default is SCREEN.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | SCREEN | Measurement gating mode. |
Sets the direction used for immediate measurement delay calculations. The factory default is FORWARDS.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | FORWARDS | Direction setting for immediate measurement delay. |
Sets the edge selection used for the immediate measurement delay. The factory default is RISE.
| Name | Type | Values | Description |
|---|---|---|---|
| edge | enum | RISE | Edge selection for the delay measurement. |
Sets the first immediate measurement source. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source1 | enum | CH1 | Measurement source 1. |
Sets the immediate measurement type. The factory default is PERIOD.
| Name | Type | Values | Description |
|---|---|---|---|
| type | enum | PERIOD | Immediate measurement type. |
Sets the measurement indicators state. Factory default is OFF.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | OFF | Turns measurement indicators off. |
Sets the delay direction used by measurement 1. The factory default is FORWARDS.
| Name | Type | Values | Description |
|---|---|---|---|
| direction | enum | FORWARDS | Delay direction for measurement 1. |
Sets the edge selection used for delay measurements for MEAS1. The factory default is RISE.
| Name | Type | Values | Description |
|---|---|---|---|
| edge | enum | RISE | Edge used for the delay measurement. |
Sets the source for measurement 1. The factory default is CH1.
| Name | Type | Values | Description |
|---|---|---|---|
| source1 | enum | CH1 | CH2 | Input source for measurement 1. |
Sets the state of measurement slot 1.
| Name | Type | Values | Description |
|---|---|---|---|
| state | integer | 0 - 1 | Enables or disables measurement slot 1. |
Selects the measurement type for MEAS1. The factory default is PERIOD.
Sets the measurement method to the factory-default value.
Sets the absolute high reference level used for measurements. The factory default is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| high | real | - | Absolute high measurement reference level. |
Sets the absolute low reference level used for measurements. The factory default is 0.0E+0.
| Name | Type | Values | Description |
|---|---|---|---|
| low | real | - | Absolute low reference level for measurements. |
Sets the absolute mid-level reference default for measurement levels. The factory default value is 0.0E+0.
Selects how reference levels are defined for measurement thresholds. The factory default is PERCENT.
Sets the high percentage reference level used by measurement functions. The factory default value is 90.0000.
Sets the low percentage reference level used by measurement functions. The factory default is 10.0000.
| Name | Type | Values | Description |
|---|---|---|---|
| low | real | % | Low percentage reference level. |
Sets the measurement reference level percent mid1 default value. This appears in the factory defaults table with a default of 50.0000.
Sets the measurement statistics mode to the selected state. The factory default is ALL.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | ALL | Measurement statistics mode. |
Sets the weighting value used by measurement statistics. The factory default is 32.
Resets the Digital Voltmeter measurements and history.
Sets or queries the autorange state for the Digital Voltmeter.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Autorange state. |
Returns the current frequency value for the Digital Voltmeter.
Returns the average readout value for the Digital Voltmeter function over the history period.
Returns the maximum readout value for the DVM function over the history period.
Returns the minimum readout value for the DVM function over the history period.
Returns the maximum DVM readout value over the entire time that the DVM has been on since the last change using the DVM:MODe or DVM:SOUrce commands or DVM RESET.
Returns the minimum DVM readout value over the entire time that the DVM has been on since the last change using the DVM:MODe or DVM:SOUrce commands or DVM RESET.
Returns the DVM readout value.
Specifies or queries the mode to use for the Digital Voltmeter.
Sets or queries the source for the Digital Voltmeter.
Sets or queries the state of the trigger frequency counter.
Sets or queries the Digital Voltmeter autorange state. Autorange is disabled while the DVM source is the same channel as the trigger source.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | OFF | ON | Turns DVM autorange on or off. |
DVM:AUTOR ON turns on autorange for the Digital Voltmeter.
Specifies or queries the mode used for the Digital Voltmeter. The available modes are ACRMS, ACDCRMS, DC, and OFF.
Sets or queries the source for the DVM.
| Name | Type | Values | Description |
|---|---|---|---|
| channel | channel_list | - | Specifies which channel to use as the source for the DVM. |
DVM:SOURCE CH4 sets the DVM source to Channel 4.
Returns the state of the trigger frequency counter readout in the trigger badge. The counter is part of the DVM trigger frequency function.
DVM:TRIGGER:FREQUENCY:COUNTER? might return DVM:TRIGGER:FREQUENCY:COUNTER 1 indicating the counter is on.
Sets the DVM autorange state. The factory default is 0.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | 0 | 1 | Turns DVM autorange off or on. |
Sets the digital voltmeter display style. The factory default is FULL.
Sets the DVM mode. The factory default is OFF.
| Name | Type | Values | Description |
|---|---|---|---|
| mode | enum | OFF | DVM mode setting. |
Sets the DVM measurement source. The factory default is CH1.
Specifies the network initialization search for a DHCP/BOOTP server.
Specifies the network Domain Name Server (DNS) IP address.
| Name | Type | Values | Description |
|---|---|---|---|
| IP address | string | - | Network DNS server IP address. |
Specifies the network domain name.
| Name | Type | Values | Description |
|---|---|---|---|
| domain name | string | - | Network domain name to assign. |
Returns the Ethernet address (MAC address) value assigned to the instrument.
Specifies the network gateway IP address.
| Name | Type | Values | Description |
|---|---|---|---|
| IP address | string | - | Network gateway address. |
Specifies the IP address assigned to the instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| ip address | string | - | IP address assigned to the instrument. |
Resets the LXI local area network.
Specifies the mDNS service name used for the LXI interface.
Returns the LXI network status.
Sets or queries the instrument Ethernet hostname assigned to the instrument.
| Name | Type | Values | Description |
|---|---|---|---|
| name | string | - | Hostname assigned to the instrument. |
Specifies the Ethernet network configuration setting.
Causes the instrument to ping the gateway IP address.
Sets the network configuration method to DHCP/BOOTP or static IP. ON enables DHCP searching for a server; OFF disables it.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | OFF | Selects whether the instrument searches for a DHCP server. |
ETHERNET:DHCPBOOTP ON
Specifies the DNS IP address the instrument uses to communicate with the network.
ETHERNET:DNS:IPADDRESS "128.196.13.252" sets the DNS IP address that the instrument uses to communicate with the network.
Specifies the network domain name.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | The network domain name, enclosed in quotes. |
ETHERNET:DOMAINNAME "Alpha1.Mycorp.com" sets the domain name that the instrument uses to communicate with the network.
This command specifies the network gateway IP address.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | The network gateway IP address, enclosed in quotes. |
Sets or queries the instrument's Ethernet IP address.
ETHERNET:IPADDRESS "123.121.13.214"
Queries the LXI mDNS service name used for the LXI interface. The value is a quoted string up to 64 characters.
ETHERnet:LXI:LAN:SERVICENAMe? might return "Tektronix Oscilloscope MSO5 053CVV".
Sets or queries the instrument Ethernet hostname assigned to the instrument.
Specifies the Ethernet network configuration setting. The instrument can be configured automatically from a DHCP server or manually using static network settings.
Returns the results of sending the ETHERnet:PING command to ping the gateway IP address.
Sets or queries the instrument subnet mask value.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | The subnet mask value, enclosed in quotes. |
ETHERNET:SUBNETMASK "255.255.255.0" sets the subnet mask value using standard IP address notation format.
Sets or queries the instrument subnet mask value.
| Name | Type | Values | Description |
|---|---|---|---|
| subnet mask | string | - | Subnet mask value, enclosed in quotes. |
ETHERNET:SUBNETMASK "255.255.255.0" sets the subnet mask value using standard IP address notation format.
Sets or queries the shape of a segment of an eye mask.
Returns the total number of hit violations for all segments in the specified mask test.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | 1 | The number of the specified mask test in an eye diagram plot. |
EYEMASK:MASK2:COUNt:HITS? might return 211, indicating that mask 2 has a total of 211 violations for all segments in the mask.
Returns the number of mask test violations for the specified mask test and mask segment.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | The number of the specified mask test or mask test plot. |
| SEG<y> | integer | - | The number of the mask segment for which to return hit violations data. |
EYEMASK:MASK1:COUNt:SEG3:HITS? might return 435, indicating that segment 3 of mask test 1 has 435 hit violations.
Returns the name of the eye diagram plot that created the specified mask. This query requires option 5-DJA or 6-DJA (Advanced Jitter Analysis).
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | The number of the specified mask test. |
EYEMASK:MASK4:CREATor? might return "plot2".
Sets the coordinate type for the specified eye mask plot. The query returns whether the coordinate type is Absolute or Relative.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Number of the specified mask plot. |
| mode | enum | ABSolute | RELative | Coordinate type to set. |
EYEMASK:MASK4:CTYPE ABS sets the coordinate type to Absolute. EYEMASK:MASK2:CTYPE? might return RELATIVE, indicating that coordinate type is Relative in the specified mask plot.
Returns the coordinate type for the specified mask plot.
EYEMASK:MASK4:CTYPE ABS sets the coordinate type to Absolute. EYEMASK:MASK2:CTYPE? might return RELATIVE, indicating that coordinate type is Relative in the specified mask plot.
Enables or disables eye mask testing in the specified mask plot.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | The number of the specified mask plot. |
| state | enum | ON | OFF | Enables or disables the eye mask test. |
EYEMASK:MASK4:ENAbled ON enables the eye mask test in the specified mask plot. EYEMASK:MASK2:ENAbled? might return 0, indicating that mask testing is disabled in the specified mask plot.
Enables or disables eye mask testing in the specified mask plot.
EYEMASK:MASK4:ENAbled ON enables the eye mask test in the specified mask plot. EYEMASK:MASK2:ENAbled? might return 0, indicating that mask testing is disabled in the specified mask plot.
Sets or queries the top bound of the undershoot segment for the specified mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| limit | real | - | Top bound value for the undershoot segment. |
EYEMASK:MASK2:LLIMit -1.5 EYEMASK:MASK5:LLIMit?
Sets or queries the top bound of the undershoot segment for the specified mask number. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| value | real | - | Top bound value for the undershoot segment. |
EYEMASK:MASK2:LLIMit -1.5 sets the value to -1.5 EYEMASK:MASK5:LLIMit? might return EYEMASK:MASK5:LLIMit -0.8 indicating the value is -0.8.
Sets or queries the current mask definition file name for the specified mask test.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the mask test number. |
| file | string | - | Quoted string that defines the file path of the mask file to use, in the format '[<path>]<filename.ext>'. |
Sets or queries the current mask definition file name for the specified mask test. The file name is a quoted string path of the form '[<path>]<filename.ext>'; if no path is given, the instrument searches the current working directory.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the mask test number. |
| file | string | - | Quoted string defining the mask file path to use. |
Returns the mask offset value in the specified mask in seconds. The mask test number is specified by <x>.
EYEMASK:MASK2:MASKOffset:HORizontal:AUTOfit? might return EYEMASK:MASK2:MASKOffset:HORizontal:AUTOfit 12e-12, indicating that mask autofit moved mask 2 by 12 ps
Adds or removes the Overshoot and Undershoot segments from an Eye Mask. The mask number is specified by <x>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | 1 | OFF | 0 | Adds or removes the Overshoot and Undershoot segments. |
Adds or removes the Overshoot and Undershoot segments from an Eye Mask. The mask number is specified by <x>.
| Name | Type | Values | Description |
|---|---|---|---|
| state | enum | ON | 1 | OFF | 0 | Adds or removes the Overshoot and Undershoot segments. |
Horizontally flips a specified eye mask segment. This command has no query form.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| SEG<x> | integer | - | Specifies the number of the mask segment. |
EYEMASK:MASK2:SEG2:FLIP:HORizontal flips the segment 2 horizontally.
Vertically flips a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| SEG<x> | integer | - | Specifies the number of the mask segment. |
EYEMASK:MASK2:SEG2:FLIP:HORizontal flips the segment 2 horizontally.
Sets or queries the height of a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| height | real | - | Height value for the specified segment. |
EYEMASK:MASK2:SEG2:HEIGht 100e-3 sets the height to 100E-3. EYEMASK:MASK5:SEG2:HEIGht? might return EYEMASK:MASK5:HEIGht 0.8 indicating the value is 0.8.
Sets or queries the height of a segment of an eye mask. The set form assigns an NR3 height value to the specified mask segment.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask number. |
| SEG<x> | - | - | Specifies the number of the specified mask segment. |
| height | real | - | Height value for the specified segment. |
EYEMASK:MASK2:SEG2:HEIGht 100e-3 EYEMASK:MASK5:SEG2:HEIGht?
Sets or queries the X/Y coordinates of all points in the designated eye mask segment. The set form defines new points in the mask, replacing any existing points.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask test. |
| SEG<x> | - | - | Specifies the mask segment. |
Sets or queries the X/Y coordinates of all points in the designated eye mask segment. The set form defines new points in the mask, replacing any existing points.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask test. |
| SEG<x> | - | - | Specifies the mask segment. |
Sets or queries the rotation of a segment of an eye mask. The rotation value is specified in degrees.
| Name | Type | Values | Description |
|---|---|---|---|
| rotation | real | degrees | Rotation value for the specified segment. |
EYEMASK:MASK2:SEG2:ROTA 20 EYEMASK:MASK5:SEG2:ROTA?
Sets or queries the rotation of a segment of an eye mask. The rotation value is specified in degrees.
| Name | Type | Values | Description |
|---|---|---|---|
| rotation value | real | degrees | Rotation of the specified segment in degrees. |
EYEMASK:MASK2:SEG2:ROTA 20 EYEMASK:MASK5:SEG2:ROTA?
Queries or sets the shape of a segment of an eye mask. The shape can be one of four geometric forms.
| Name | Type | Values | Description |
|---|---|---|---|
| shape | enum | TRIAngle | RECTangle | TRAPezoid | HEXAgon | Shape of the specified eye mask segment. |
Queries or sets the shape of a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| shape | enum | TRIAngle | RECTangle | TRAPezoid | HEXAgon | Shape of the specified eye mask segment. |
Sets or queries the width of a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask number. |
| SEG<x> | - | - | Specifies the mask segment number. |
| width | real | - | Width value for the specified segment. |
EYEMASK:MASK2:SEG2:WIDTH 100e-12 sets the width to 100E-12. EYEMASK:MASK5:SEG2:WIDTH? might return EYEMASK:MASK5:WIDTH 0.8 indicating the value is 0.8.
Sets or queries the width of a segment of an eye mask.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask number. |
| SEG<x> | - | - | Specifies the mask segment number. |
| width | real | - | Width value for the specified segment. |
EYEMASK:MASK2:SEG2:WIDTH 100e-12 EYEMASK:MASK5:SEG2:WIDTH?
Sets or queries the center X position of a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | - | - | Specifies the mask number. |
| SEG<x> | - | - | Specifies the mask segment number. |
| XPOS | real | - | Center X value for the specified mask segment. |
Sets or queries the center X position of a segment of an eye mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Mask and segment indices are specified in the command mnemonic as MASK<x>:SEG<x>. |
| xpos | real | - | Center X value for the specified mask segment. |
Sets or queries the center Y value for a specified eye mask segment.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| SEG<x> | integer | - | Specifies the number of the mask segment. |
| <NR3> | real | - | Center Y value for the specified segment. |
EYEMASK:MASK2:SEG2:YPOS 100e-3 sets the center Y to 100E-3. EYEMASK:MASK5:SEG2:YPOS? might return EYEMASK:MASK5:YPOS 0.2 indicating the value is 0.2.
Sets or queries the center Y of a specified eye mask segment. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
| SEG<x> | integer | - | Specifies the number of the given mask segment. |
| YPOS | real | - | Center Y value for the specified segment. |
EYEMASK:MASK2:SEG2:YPOS 100e-3 sets the center Y to 100E-3. EYEMASK:MASK5:SEG2:YPOS? might return EYEMASK:MASK5:YPOS 0.2 indicating the value is 0.2.
Sets or queries the total number of hit violations that will cause a mask test failure.
Sets or queries the total number of hit violations that will cause a mask test failure.
Returns the mask hit test status for the specified mask test. Valid status strings are PASS, FAIL, and OFF.
EYEMASK:MASK2:TESt:STATUS? might return Fail, indicating that mask testing has failed in the specified mask plot.
Sets or queries the bottom bound value for the overshoot segment of the specified mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| MASK<x> | integer | - | Specifies the mask number. |
EYEMASK:MASK2:ULIMit 1.5 EYEMASK:MASK5:ULIMit?
Queries the bottom bound value for the overshoot segment of a specified mask. Requires option DJA.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Specifies the mask number. |
EYEMASK:MASK5:ULIMit? might return EYEMASK:MASK5:ULIMit 0.8 indicating the value is 0.8.
Sets or queries the field type for the math for the bus source for ETHERCAT bus.
Adds the specified math waveform to the setup.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Quoted string specifying the math waveform to add, in the form "MATH<NR1>" where <NR1> is greater than or equal to 1. |
MATH:ADDNEW "MATH2" adds MATH2.
Deletes the specified math waveform. The waveform name must be a quoted string of the form "MATH<NR1>" with NR1 ≥ 1.
| Name | Type | Values | Description |
|---|---|---|---|
| QString | string | - | Quoted string specifying the math waveform to delete. |
MATH:DELETE "MATH1"
Returns a comma separated list of all currently defined math waveforms.
MATH:LIST? Might return MATH:LIST MATH1,MATH4, indicating MATH1 and MATH4 are the currently defined math waveforms.
Sets or queries the field type for the math bus source for ARINC429A. The math waveform is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| DATa | enum | DATa | Sets the field type to DATa. |
Sets or queries the field type for the math bus source for Audio bus. The math waveform is specified by x.
| Name | Type | Values | Description |
|---|---|---|---|
| x | integer | - | Math waveform number. |
| field type | enum | LCHannel | RCHannel | TDMChannel | Field type to set for the Audio bus source. |
MATH:MATH2:AUDIO:SUPPortedfields LCHannel MATH:MATH2:AUDIO:SUPPortedfields?
Sets or queries the field type for the math bus source for AUTOETHERnet. The math waveform is specified by x.
| Name | Type | Values |
|---|